Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA09RI057Cooling Fan · malfunctionedFLIGHT 3009 - EWR - FLIGHT CREW REPORTED BURNING SMELL AND SMOKE IN THE COCKPIT. EWR MX REMOVED AND REPLACED NR 2 RECIRCULATING FAN AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. NO SMOKE/ NO BURNING SMELL NOTED. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR FDKA2009041300072Light · malfunctionedFRL FLT 6272 CVG-PVD. ROW 12 OVERHEAD EMERGENCY LIGHT INOP. MX RESET LIGHTING SYSTEM, OPS CHECK GOOD.SDR FDKA2009041200071Door · lack of lubeFRL FLT 6223 JFK. MAIN CABIN DOOR HARD TO OPEN AND CLOSE. MX CLEANED AND LUBED DOOR, OPS GOOD.SDR SIMA200910301Flashlight · meltedON FLIGHT 3509, AT CRUISE AND FL 360 PAX AND CREW DETECTED THE ODOR SOMETHING BURNING. AT THIS TIME BOTH VS INDICATION +4000 -4000 FPM AND 'ALT ON BOTH PFD AIRSPEED DECREASING. AT ABOUT FL 320 ALL SYSTEMS BACK TO NORMAL. AIRCRAFT REMOVED FROM SERVICE. REMOSDR C2XA09SH118Door Frame · corrodedSHV DURING C-CHECK, CORROSION ON SERVICE DOOR LOWER FRAME. REPAIRED SERVICE DOOR LOWER FRAME IAW EC 5210-01154. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH117Floor Support · corrodedSHV DURING C-CHECK. LT OMEGA BEAM HAS CORROSION AT FR 43-44. REPAIRED LT OMEGA BEAM IAW SRM 53-00-10. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH116Floor Support · corrodedSHV DURING C-CHECK. LT OMEGA BEAM HAS CORROSION AT FR 49-50. REPAIRED LT OMEGA BEAM IAW EC 5310-01466. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH115Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION AT FR 33-34. REPAIRED LT OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09RI058Controller · faultyFLIGHT 2519 - ROC - FLIGHT CREW REPORTED ACFT DEPRESSURIZED ON DESCENT THOUGH FL200, CABIN ALTITUDE INCREASED, CABIN DIFFERENTIAL DECREASED AND CABIN RATE WAS POSITIVE NOT NEGATIVE BUT NO EICAS MESSAGE. CREW VERIFIED CORRECT CONTROLLER SETTINGS. EWR MX REMOVSDR FDKA2009041100070Seal · lack of lubeFRL 6247 DTW-CVG. CAPTAIN REPORTED THE MAIN CABIN DOOR AS DIFFICULT TO OPEN AND CLOSE BY THE F/A. MX LUBED DOOR AND SEALS.SDR SIMA200910303Sign · inoperativeON FLIGHT 3986, ON GROUND MAINTENANCE REPORTED EMERGENCY EXIT SIGN OVER FLIGHT ATTENDANTS SEAT WILL NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY EXIT SIGN ABOVE FLIGHT ATTENDANT SEAT IAW AMM 33-15-14. OPERATION CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA09CL043Turbine Wheel · crackedDURING COMPLIANCE OF SB AE3007A-72-368 ON THE NR 1 ENGINE A CRACK INDICATION OF THE 2ND STAGE HIGH PRESSURE TURBINE WHEEL WAS FOUND WHILE PERFORMING THE ULTRASOUND INSPECTION. THE NR 1 ENGINE WAS REPLACED.SDR SIMA200910304SUPRelay · malfunctionedON FLIGHT 4323, CREW REPORTED DURING APPROACH ENGINE 2 THRUST REVERSER FAIL MSG ON EICAS. CREW DECLARED AN EMERGENCY. APPLIED MEL 7801. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED RELAYS IAW EMB 145 AMM 20-13-02-000-801-A AND 20-13-02-400-801-A. DSDR C2XA09RI067Housing · leakingFLIGHT 2586 - IND - FLIGHT CREW REPORTED NR 2 ENGINE LOSS OF OIL/PRESSURE IN FLIGHT. CREW PERFORMED INFLIGHT SHUTDOWN AND LANDED UNEVENTFULLY. MX REMOVED AND REPLACED OIL FILTER HOUSING ASSY AND PERFORMED OPERATIONAL/LEAK CHECK SUCCESSFULLY. ACFT WAS APPROVSDR RAIA2009041400004Duct · crackedFLT 7983 - IAD - CREW RECEIVED A BLEED LEAK NR 1 MESSAGE ON THE EICAS. MAINTENANCE REMOVED AND REPLACED BLEED DUCTS. SYSTEM OPS CHECKED GOOD.SDR SIMA200910408Sill · corrodedDURING A IMBV INSPECTION, THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED. REMOVED THE DAMAGED SILL AND CLEANED THE AREA. POSITION THE NEW SILL AND DRILLED, REMOVED TO CLEAN AND TREAT NEW PART. REPAIR DONE IAW SRM 51-20-01, 51-20-03, 51-40-02, 51-40-04 AND SDR SIMA200910407Sill · corrodedDURING A IMBV INSPECTION, THE BAGGAGE DOOR CUT OUT LOWER SILL WAS FOUND CORRODED. REMOVED THE DAMAGE SILL AND CLEANED THE AREA. POSITIONED NEW SILL AND DRILLED, CLEANED AND TREATED PARTS AND INSTALLED. REPAIR DONE IAW SRM 51-20-01,03, 51-40-02, 04 AND 06. SDR SIMA200910304Warning Light · illuminatedON FLIGHT 4323, CREW REPORTED DURING APPROACH ENGINE 2 THRUST REVERSER FAIL MSG ON EICAS. CREW DECLARED A EMERGENCY. APPLIED MEL 7801.SDR C2XA09CL042Inverter · inoperativeDURING ROUTINE MAINTENANCE THE FIRST AISLE PATH LIGHT STRIP AND LOWER SERVICE DOOR LIGHT WAS FOUND INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE NR 2 EMERGENCY LIGHT INVERTER. OPERATIONAL CHECKS WERE GOOD.SDR C2XA09CL040Pump · leakingCLE - FLIGHT 2690 THE CREW REPORTED, LOST ALL NR 2 HYDRAULIC SYSTEM FLUID IN FLIGHT. THE AIRCRAFT LANDED IN CLE WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ENGINE DRIVEN HYDRAULIC PUMP. OPERATIONAL CHECKS WERE GOOD.SDR C2XA09TY059Housing · leakingIAH/IND- NR 2 ENGINE LOST OIL/OIL PRESSURE IN FLIGHT AND THE ENGINE WAS SHUTDOWN. AN EMERGENCY WAS DECLARED AND A/C LANDED SAFELY. UPON INSPECTION THE OIL FILTER HOUSING WAS FOUND TO BE LEAKING. MX REMOVED AND REPLACED THE OIL FILTER HOUSING AND LEAK CHECKESDR RAIA2009041400003Antenna · defectiveFLT 7952 - MSN - DURING CLIMB, THE CREW RECEIVED AN INTERMITTENT RAD ALT, GPWS AND WINDSHEAR MESSAGE ON THE EICAS. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE RAD ALT ANTENNAS. SYSTEM OPS CHECKED GOOD.SDR FDKA2009040900069Light · inoperativeFRL FLT 6189 JFK-RIC. ROW 3 BULKHEAD EMERGENCY LIGHT INOP. RELAMPED EMERGENCY LIGHT.SDR FDKA2009040900068Connector · looseFRL FLT 6231 ORF. ROW 12 AISLE EMERGENCY LIGHT INOP. MX RE-SECURED THE CONNECTOR, OPS CHECK GOOD.SDR C2XA09CL038Turbine Wheel · crackedDURING COMPLIANCE OF SB AE3007A-72-368 ON THE NR 1 ENGINE A CRACK INDICATION OF THE 2ND STAGE HIGH PRESSURE TURBINE WHEEL WAS FOUND WHILE PERFORMING THE ULTRASOUND INSPECTION. THE NR 1 ENGINE WAS REPLACED.SDR RAIA2009041400002Power Supply · dischargedPRE FLT 7946 - STL - THE CABIN EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT POWER SUPPLY. SYSTEM OPS CHECKED GOOD.SDR FDKA2009040800067Connector · looseFRL FLT 6194 CVG-IAD. EMERGENCY EXIT SIGN AT ROW 12 INOP. MX RE-SECURED THE LIGHT CONNECTORS, OPS CHECK GOOD.SDR C2XA09CL041Tube · leakingDURING ROUTINE MAINTENANCE THE PRESSURE REFUEL/DEFUEL LINE WAS FOUND LEAKING. MAINTENANCE INSPECTED AND FOUND THE TUBE ASSEMBLY TO BE CORRODED. THE TUBE WAS REPLACED AND OPERATIONAL CHECKS WERE GOOD.SDR CHQA200900103Connector · unsecureFLIGHT 6033, CVG TO MSY. AFTER TAKE-OFF THE CREW RECEIVED A CABIN SERVICE DOOR WARNING ON EICAS AND RETURNED TO CVG AND LANDED WITHOUT INCIDENT. MAINTENANCE DEFERRED THE SERVICE DOOR EICAS INDICATION AND RELEASED THE AIRCRAFT FOR SERVICE. THE DEFERRAL WAS CLSDR C2XA09CL039Unknown · odorIAH FLIGHT 2629 THE CREW REPORTED A STRONG SMELL OF FUEL ON TAKEOFF. THE APU WAS PLACED ON MEL AND THE AIRCRAFT WAS RELEASED FOR SERVICE. CLE MAINTENANCE PERFORMED ON OPERATIONAL CHECK OF THE APU WITH BOTH PACKS SELECTED AND NO FUEL SMELL WAS NOTED. THE MEL WSDR FDKA2009040700065Handle · misinstalledFRL FLT 6222 JFK-ROC. RT EMERGENCY DOOR HANDLE INSTALLED IMPROPER IN ROW 12. MX INSTALLED HANDLE PROPERLY.SDR FDKA2009040700064Seal · dirtyFRL FLT 6270 JFK-PWM. MAIN DOOR WILL NOT CLOSE. CLEANED AND LUBE DOOR SEAL AND ROLLERS, OPS CHECK GOOD.SDR SIMA200909807Floor Support · corrodedDURING I-MBV INSPECTION, THE LEFT OMEGA BEAM AT FR 20 WAS FOUND TO BE CORRODED BEYOND MANUAL LIMITS. PERFORMED A CUT OUT OF CORRODED AREA FABRICATED. REPAIR PARTS FROM EPM53EP54701 FILLER AND 54703 FOR SHIMS FROM AL2024-T3. DRILLED, CLEANED, DEBURRED AND TRSDR CHQA200900102Proximity Switch · faultyFLIGHT 3054, BUF TO BOS - THE FLIGHT CREW RECEIVED A LANDING GEAR AIR/GROUND FAIL MESSAGE ON TAKEOFF. THE AIRCRAFT RETURNED TO BUF AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND CMC MESSAGES FOR LGEU FAIL AND PROX SWITCH FAIL. AN AIR/GROUND TEST WAS PERFORMSDR SIMA200909804Floorbeam · corrodedDURING A MBV INSPECTION THE RIGHT FLOORBEAM WAS FOUND TO BE CORRODED AT FRAME 23. REMOVED CORROSION BY BLENDING AND PERFORMED NDT INSP CLEANED, ALODINED AND PRIMED THE REWORKED AREA. FILLED IN BLENDED AREA. FABRICATED A DOUBLER. REPAIR DONE IAW SRM 53-21-1SDR I7ER 0901Seat Frame · crackedBASE FRAME ASSY (LEG) HAVE BEEN FOUND CRACKED IN THE AREA SURROUNDING ATTACHMENT FROM FRAME TO SEAT. ON THIS PARTICULAR ACFT 10 DOUBLE SEAT BASE FRAME (LEG) ASSEMBLIES WERE FOUND CRACKED. THIS PARTICULAR PART HAS BEEN REMOVED AND REPLACED WITH NEW PART.SDR FDKA2009040600063Light · inoperativeFRL FLT 6223 JFK-CLT. EMERGENCY LIGHT STRIP IN 12C INOP. MX FOUND LIGHT TO BE OPERATIVE, NO FAULT FOUND.SDR CHQA200900101Light · inoperativeDURING C-CHECK INSPECTION, THE SERVICE DOOR FRAME EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. THE AIRCRAFT IS CURRENTLY IN C-CHECK AND THE WRITE-UP IS CURRENTLY STILL OPEN. MAINTENANCE REPLACED THE SERVICE DOOR FRAME EMERGENCY EXIT LIGHT IAW EMB 145 AMSDR FDKA2009040500062Connector · looseFRL FLT 6226 CVG. AFT CEILING FWD SIDE EMERGENCY EXIT LOCATOR INOP. MX RE-SECURED LOOSE CONNECTOR, OPS GOOD.SDR C2XA09IA091Inverter · inoperativeIAH - FLIGHT 3139 - DURING POST FLIGHT INSPECTION THE CREW REPORTED THAT THE EXIT SIGN AT ROW 12 WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 6 EMERGENCY LIGHT INVERTER, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVSDR CHQA200900099Battery Pack · dischargedDURING INSPECTION THE LEFT EXTERNAL EMERGENCY LIGHT WAS FOUND INOP ALONG WITH THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS. THE NR 1 EMERGENCY LIGHT BATTERY PACK WAS REPLACED FOR THE EXTERNAL LIGHT AND THE NR 4 BATTERY PACK FOR THE OVERWING LIGHTS.SDR SIMA200909601Unknown · odorON FLIGHT 4300, CREW REPORTED A ELECTRICAL BURNING ODOR FOR SHORT DURATION DURING CLIMB-OUT. ODOR CONFINED TO COCKPIT AND WAS NOTED BY CAPT AND F/O. NO VISIBLE SMOKE AND NO SYSTEM ANOMALIES. AIRCRAFT REMOVED FROM SERVICE. CHECKED COCKPIT LIGHTING-CONTROLS,SDR SIMA200909803Profile · corrodedDURING AN IMBV INSPECTION, THE MAIN DOOR LOWER PROFILE WAS FOUND TO BE CORRODED AROUND THE AFT SCREW HOLE. REMOVED CORROSION BY BLENDING, PERFORMED NDT INSPECTION, NO CRACK NOTED. FABRICATED A DOUBLER. DRILLED, CLEANED, ALODINED AND PRIMED DOUBLER AND BLENDSDR SIMA200909801Sill · corrodedDURING A IMBV INSPECTION THE CARGO DOOR CUT OUT LOWER SILL WAS FOUND TO BE CORRODED. REMOVED CORRODED LOWER SILL. OBTAINED REPLACEMENT SILL. DRILLED, CLEANED, ALODINED AND PRIMED NEW SILL. INSTALLED NEW SILL IAW EMBRAER SRM (SRM 145/1142 REV 40)CHAPTER 51-20SDR C2XA09TY058Tube · leakingAIRCRAFT ON CLIMBOUT FROM EWR TO TYS REACH A HIGH ITT. MAINTENANCE REPLACED THE RT COMPRESSOR AIR TUBE ON THE E1 IAW ROLLS ROYCE MM 75-00-00, OPS AND LEAK CHECKS WERE GOOD AND RETURN TO SERVICE.SDR C2XA09RI049Unknown · odorFLIGHT 4932 - EWR - FLIGHT CREW REPORTED STRONG ODOR OF SMOKE IN THE COCKPIT SHORTLY AFTER INITIAL DESCENT. EWR MX RAN PACKS, PRESSURIZED AIRCRAFT, TURNED W/S HEAT ON AND HYDRAULIC PUMPS. NO SMELL WAS DETECTED. AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR CHQA200900098Battery Pack · dischargedDURING INSPECTION THE LEFT-HAND OVER WING EMERGENCY LIGHT WAS INOP WHEN TESTED. THE NR 4 EMERGENCY LIGHT POWER SUPPLY WAS REPLACED AND THE SYSTEM OPERATED NORMALLY.SDR CHQA200900097Switch · intermittentFLIGHT 7860, IAD TO YOW. DURING CLIMB-OUT, THE CREW RECEIVED AN EICAS MESSAGE FRO BLEED 2 VALVE CLOSED. THE QRH WAS FOLLOWED BUT DID NOT CLEAR THE FAULT. DUE TO FORECAST ICING CONDITIONS THE AIRCRAFT RETURNED TO IAD AND LANDED WITHOUT INCIDENT. THE FIM WASSDR RAIA2009040700001Power Supply · dischargedDURING MAINTENANCE THE LEFT FORWARD FUSELAGE EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 3 EMERGENCY LIGHT POWER SUPPLY. OPS CHECKED GOOD.SDR C2XA09RI050Unknown · odorFLIGHT - 2554 - EWR-JAX - FLIGHT CREW DIVERTED TO SAV DUE TO LIGHTNING STRIKE ACCOMPANIED WITH STRONG BURNING SMELL IN COCKPIT. MX INSPECTED AIRCRAFT AND FOUND NO EVIDENCE OF LIGHTNING STRIKE. FLIGHT CREW RAN PNEUMATIC SYSTEMS AND COULD NOT DUPLICATE SMELL IN
Back to Embraer EMB-145LR