Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA04BT082Lamp · burned outNON-ROUTINE WORK CARD WRITE UP, NR 2 OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED NR 2 OVERWING EMERGENCY LIGHT IAW EMB 145 MM 33-50-07. OPS CHECK GOOD.SDR C2XA04SH473Light · inoperativeDURING C CHECK THE PANEL 195 LT LATERAL WING TO FUSELAGE FAIRING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE CLEANED THE CONNECTOR ON THE EMERGENCY LIGHT IAW 145 AWM 20-50-00. THE LIGHT OPERATIONAL CHECKED GOOD. THE AIRCRAFT WAS APPROVED FOR RESDR C2XA04SH472Floorbeam · corrodedSHV - DURING C-CHECK THE LEFT FLOORBEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 24 AND 25. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A SHIM FILLER REPAIR IAW EMB 145 SRM 53-21-10, STEP 3 FIG 202, SHEET 1. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVSDR CHQA000529Wire · disconnectedEMERGENCY LIGHTING INOP. FOUND QUICK DISCONNECT ON SEAT 7A DISCONNECTED FROM WIRING. INSTALLED NED QUICK DISCONNECT IAW WM 20-50-01. OPS CHECK GOOD.SDR C2XA04SH470Floorbeam · corrodedDURING C-CHECK THE LT FLOORBEAM WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A DOUBLER REPAIR IAW EC 5310-01283. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA04SH469Floorbeam · corrodedSHV - DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED AT FRAME 24, GREATER THAN 30 PERCENT OF ORIGINAL THICKNESS OF .070 INCH (OUT OF LIMITS) BUT WITHIN REPAIRABLE LIMITS.SDR CHQA000524Battery · inoperativeWITH COCKPIT EMERGENCY LIGHT SWITCH IN THE ARMED POSITION, ROWS 1-7 FLOOR EMERGENCY PATH LIGHTS AND GALLEY EMERGENCY EXIT LIGHTS CAME ON. AIRCRAFT WAS FERRIED FROM IAD TO IND FOR MAINTENANCE. REMOVED AND REPLACED NR 2 EMERGENCY BATTERY ASSEMBLY POWER SUPPLY SDR CHQA000523Odor · detectedDURING CRUISE FLIGHT A BURNING ODOR OCCURRED WHEN THE ANTI ICE SYSTEM WAS ACTIVATED IN ICING CONDITIONS. PERFORMED OPERATIONAL CHECK OF THE PNEUMATIC SYSTEM AND FOUND NO SMELL OR DEFECTS IN THE SYSTEM AT THIS TIME AND DATE. INSPECTED IAW EMB 145 AMM 36-00-00SDR CHQA000526Battery · inoperativeFIRST SECTION OF PASSENGER EMERGENCY FLOOR LIGHTING IS INOP. REMOVED AND REPLACED THE NR 2 EMERGENCY BATTERY. OPERATIONAL CHECK IS GOOD AT THIS TIME.SDR C2XA04SH468Floorbeam · corrodedSHV - DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE AFFECTED FLOORBEAM IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA000522Odor · detectedDURING CRUISE THERE WAS A STRONG ELECTRICAL SMELL COMING FROM THE INSTRUMENT PANEL. THE SMELL ONLY LASTED A FEW SECONDS. INSPECTED AIRCRAFT FOR ELECTRICAL SMELL. NO SMELL NOTED. COULD NOT DUPLICATE. RAN APU AND CYCLED WINDSHIELD HEAT. NO DEFECTS NOTED IASDR CHQA000521Odor · detectedDURING CRUISE, AT 10,000 FT, NOTICED A STRONG ELECTRICAL ODOR COMING FROM UNDER THE CAPTAINS PFD. ONCE ON THE GROUND DETERMINED THAT THE CAPTAINS PFD WAS CONSIDERABLY HOTTER THAT THE OTHER TUBES. TURNED OFF THE AVIONICS AND THE HEAT SUBSIDED. INSPECTED AVIOSDR CHQA000519Light · inoperativeRT OVER WING EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED THE RT OVER WING EXIT LIGHT. OPS CHECK GOOD IAW EMB 145 MM 33-50-01.SDR CHQA000520Carbon Seal · leakingCREW REPORTS ON CLIMB OUT AT HIGH POWER THEY EXPERIENCED A BURNING ODOR IN THE AIRCRAFT. THE POWER WAS DECREASED AND THE ODOR DISSIPATED. AS POWER WAS INCREASED THE BURNING ODOR CAME BACK. RAN BOTH ENGINES AT 98 PERCENT FOR 5 MINUTES AND AT GROUND IDLE FOR SDR C2XA04BT079Power Supply · faultyMAINTENANCE REPORTED, DURING SERVICE CHECK, LT FRONT FAIRING WING FUSELAGE EMERGENCY LIGHT INOPERATIVE AND NR 1 AISLE PATH EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED NR 1 BATTERY POWER SUPPLY IAW EMB145 NR 33-50-04, OPS. CHECKED SYSTEM GOOSDR C2XA04SH466Battery · dischargedDURING C-CHECK THE NR 4 EMERGENCY LIGHT BATTERY WAS FOUND TO BE DISCHARGED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED EMERGENCY LIGHT BATTERY, THE ENSUUING OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA00407012Engine · malfunctionedDEN - LEFT ENGINE HIGH ITT UPON SETTING T/O TRUST. MAINTENANCE INSPECTED NR 1 ENGINE AND PERFORMED ENGINE RUN. ALL INDICATIONS NORMAL IAW ROLLS ROYCE MM 72-00-00.SDR MASA200400415Light · inoperativeDURING MAINTENANCE, FOUND 1ST SECTION OF FLOOR EMERGENCY LIGHTING STRIP WOULD NOT ILLUMINATE. DEFERRED IAW MEL 33-50-00-2. MAINTENANCE REPLACED THE LIGHTING STRIP ON 7/20/04. OPS CHK GOOD.SDR SIMA20040501Control Unit · inoperativeORD - FLT 4057 - DURING CLIMB, CREW REPORTED A PITCH TRIM 1 INOPERATIVE MESSAGE ON EICAS. MAINTENANCE REMOVED AND REPLACED THE HORIZONTAL STABILIZER CONTROL UNIT, IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR CHQA000528Filler · missingEMERGENCY FLOOR PROXIMITY LIGHTS STRIPS ARE MISSING FILLER STRIPS. INSTALLED FLOOR PROXIMITY FILLER STRIPS IAW AMM 33-50-12.SDR MASA200400414Pitch Control · malfunctionedRETURNED TO THE FIELD DUE TO A PITCH TRIM 1 AND 2 INOPERATIVE AND CAS MISCOMPARE MSG. MECHANIC RESET THE PITCH TRIM SYSTEM AND IT OPERATED NORMALLY. ALL MESSAGES CLEARED AND A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR C2XA04CL075Connector · disconnectedCLE FLIGHT 2249, THE CREW REPORTED THE EMERGENCY LIGHT IN THE CABIN AT SEAT 3B WAS NOT WORKING. MAINTENANCE INSPECTED AND CONNECTED EMERGENCY LIGHT. OPERATIONAL CHECKS WERE GOOD.SDR SIMA200420102Control Unit · inoperativeCREW NOTED AFTER ROTATION SPOILER OPEN INDICATION ACCOMPANIED WITH EICAS MESSAGE SPOILER FAIL AND TAKEOFF CONFIGURATION WARNING. REPLACED SPOILER CONTROL UNIT. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR MASA200400412Priority Valve · inoperativeSUP/CLOSED -ASH 2701 FROM CAE-PHL. THE LANDING GEAR WOULD NOT RETRACT DURING CLIMBOUT. IAW CFM CREW MADE 2ND ATTEMPT AND GEAR RETRACTED NORMALLY. MX TAKING A/C TO HANGER FOR TROUBLESHOOTING. MAINTENANCE REPLACED PRIORITY VALVE.SDR MASA200400408Sign · inoperativeAIRCRAFT WAS ON RON LAST NIGHT AND SCHEDULED FOR A ROUTINE INSPECTION. DURING THE WALKAROUND DISCOVERED ROW 12 CEILING EMERGENCY EXIT SIGN LIGHT INOP. MAINTENANCE REPLACED THE LIGHT, OPERATIONAL CHECK GOOD.SDR CHQA000516Light · inoperativeFLOOR PROXIMITY LIGHTS STRIP RUNNING AFT TO OVERWING EXITS ARE INOP. REMOVED AND REPLACED CABIN FLOOR PROXIMITY LIGHT STRIP IAW EMB 145 AMM 33-50-12. OPS CHECKS GOOD.SDR C2XA04SH462Stiffener · chafedSHV - DURING C-CHECK THE NR 1 ENGINE UPPER COWLING AFT STIFFENER WAS FOUND TO BE CHAFED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED STIFFENER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA04SH461Stiffener · chafedSHV - DURING C-CHECK THE NR 1 ENGINE LOWER COWLING AFT STIFFENER WAS FOUND TO BE CHAFED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED STIFFENER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA04SH460Floorbeam · corrodedSHV - DURING C-CHECK THE LEFT HAND OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA04BT078Light · inoperativeCREW REPORTED, (STRIP OF EMERGENCY AISLE PATH LIGHTS NOT WORKING.) MAINTENANCE RELEASED THE AIRCRAFT IAW MEL NR 33-50-00/02 CATEGORY C-PLACARD NR 044167 AND RETURNED THE AIRCRAFT TO SERVICE. ON IAD RON 07/16/2004 MAINTENANCE TROUBLESHOT AND REMOVED AND REPLASDR CHQA000515Light · inoperativeWHILE PERFORMING JOB CARD 33-50-04-720-001, THE NR 1 POSITION CHASSIS WAS UNABLE TO POWER THE EMERGENCY LIGHTS. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY PACK ASSY IAW EMB 145 AMM 33-50-04. OPS CHECK GOOD.SDR C2XA04IA086Control System · malfunctionedON APPROACH THE CREW REPORTED THAT THE FLAPS WERE STUCK AT 22 DEGREES. THE CREW ABORTED THE APPROACH, AND LANDED AT LIT WITHOUT INCIDENT. MAINTENANCE RESET THE FLAPS, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA00407011Control Unit · failedYOW - AIRCRAFT RAN OFF END OF RUNWAY SUSPECT TOTAL BRAKE FAILURE. MAINTENANCE REMOVED AND REPLACED BRAKE CONTROL UNIT.SDR RAIA00407006Warning Light · false activationLAV SMOKE ON EICAS THROUGH 13,000 FT, ICE PROTECT CAME ON ABOUT THE SAME TIME. INSPECTED ELECTRICAL SYSTEM AND LAV COULD NOT DETECT ANY SMOKE.SDR C2XA04CL072Carbon Seal · leakingTHE CREW REPORTED SMOKE IN THE COCKPIT AND CABIN ON CLIMB. THEY ALSO REPORTED A LAV SMOKE LITE WARNING. THE AIRCRAFT RETURNED TO EWR AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE NR 1 ENGINE AND OPERATIONAL CHECKS WERE GOOD.SDR C2XA04BT077Fan · seizedCREW REPORTED, CABIN SMOKE ONCE AIRBORNE WITH ENGINE BLEED SELECTED ON. AIRCRAFT RETURNED TO NEWARK, LANDED UNEVENTFULLY. MAINTENANCE FOUND CABIN RECIRCULATING FAN INOPERATIVE. REMOVED AND REPLACED CABIN RECIRCULATING FAN IAW EMB145 MM 21-24-01, OPS CHECKEDSDR C2XA04TY111Floorbeam · corrodedTYS - DURING A SCHEDULED 1C INSPECTION THE CENTER FLOORBEAM AT FR 25 WAS FOUND CORRODED. MAINT BLENDED AREAS OF CORROSION FORWARD OF CROSSBEAM AT FR 25. ALODINED BLENDED AREA. PRIMED AND PAINTED AREA IAW EMB 135/145 CPM 51-21-04, 05, 06 AND SRM 51-10-03. ASDR C2XA04TY110Floorbeam · corrodedTYS - DURING A SCHEDULED 1C INSPECTION THE RT OMEGA BEAM FOR THE AISLE CROSS BEAM WAS FOUND CORRODED AT FR 25. MAINTENANCE REMOVED THE CORRODED AREA, FORMED, BENT A DOUBLER AND FILLER, PLUS SHIMS, ALODINED, PRIMED AND PAINTED. FAB PARTS WERE INSTALL IAW EMB SDR CHQA000512Odor · detectedDURING LATER PORTION OF THE FLIGHT, DETECTED ODOR IN THE COCKPIT AND FORWARD CABIN AREA. IT SMELLED LIKE BURNING PLASTIC AND THERE WAS NO VISIBLE SMOKE. VISUALLY INSPECTED RADAR, FORWARD ELECTRONICS BAY, BATTERY COMPARTMENT, BEHIND OVERHEAD CIRCUIT BREAKER PSDR MASA200400391Bulb · burned outCREW REPORTED THE LT WING FORWARD EXTERIOR EMERGENCY EXIT LIGHT INOP. MAINTENANCE RELAMPED AND IT OPS CHECKED GOOD.SDR SIMA200419406Warning Light · false activationON CLIMB-OUT CREW NOTICED YELLOW TAB INDICATING CAPTAINS DV WINDOW OPENED. CREW RETURNED TO FIELD WITH NO FURTHER INCIDENT. MAINTENANCE INSPECTED AND PERFORMED OPERATIONAL CHECK OF WINDOW WITH NO DEFECTS NOTED. LOCKED WINDOW AND RETURNED AIRCRAFT TO SERVICESDR C2XA04SH456Crossbeam · corrodedSHV - DURING C-CHECK THE CROSSBEAM AT FRAME 23 FROM THE SERVICE DOOR AFT SILL TO THE RIGHT HAND OMEGA BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED CROSSBEAM IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERSDR C2XA04SH455Floorbeam · corrodedSHV - DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE AFFECTED FLOORBEAM IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA04CL069Light · inoperativeDURING ROUTINE MAINTENANCE THE EMERGENCY FLOOR LIGHT STRIP WAS INTERMITTENT AT ROW 15-17. MAINTENANCE REPLACED THE FLOOR LIGHT STRIP AT ROW 15-17. OPERATIONAL CHECKS WERE GOOD.SDR C2XA04CL070Lamp · inoperativeDURING ROUTINE MAINTENANCE THE EMERGENCY LIGHT IN AISLE AT ROW 12 WAS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT BULB AT ROW 12 EMERGENCY LIGHT. OPERATIONAL CHECKS WERE GOOD.SDR MASA200400390Power Supply · inoperativeASH 2994 DCA, CREW REPORTED THE EMERGENCY EXIT LIGHT AT GALLEY INOP. MX TROUBLESHOT TO BAD POWER SUPPLY. MX REPLACED THE POWER SUPPLY ASSY.SDR MASA200400389Light · inoperativeTHE FORWARD BULKHEAD EMERGENCY EXIT LIGHT INOP. MX RESECURED THE LIGHT ASSEMBLY AND IT OPERATED NORMALLY. A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR SIMA200419405Power Supply · inoperativeORD - FLT 4065 - FOUND EMERGENCY EXIT LIGHTS ON BOTH WALLS NEAR OVERWING EMERGENCY EXITS ARE INOPERATIVE. REPLACED EMERGENCY BATTERY POWER SUPPLY. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR SIMA200419404Light · inoperativeDFW - FLT 3533 - FOUND EMERGENCY EXIT LIGHT ABOVE GALLEY INOPERATIVE. REPLACED EMERGENCY LIGHT LOCATOR IAW EMB MM 33-50-00. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR CHQA000518Light · inoperativeFLOOR LEVEL EMERGENCY LIGHTING AT SEAT 8A DOES NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY LIGHTING STRIP AT SEAT 8A IAW EMB 145 AMM 33-50-12. OPS CHECK GOOD.
Back to Embraer EMB-145LR