Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20221029002None · inoperativeFA FORWARD FLASHLIGHT INOP-C/A-SPARE FLASHLIGHT PROVIDED TO FLIGHT ATTENDANT. FLASHLIGHT DEFERRED PER EMB145 MEL 25-32. M PROCEDURES C/WSDR SIMA20221029001Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH EMERGENCY OVERWING LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. RAR LH EMERGENCY OVERWING LIGHT ASSEMBLY WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GSDR HNAA2022103100297Engine · unknownDURING CLIMB ENG 2 OUT EICAS MESSAGE WITH NOTABLE POP SOUND. R&R #2 ENGINE IAW W/C 71-00-00SDR HNAA2022103100296Connector · dirtyLAV SMOKE MASTER WARNING DISPLAYED AND AUDIBLE ON TAKE OFF. UNABLE TO DUPLICATE ISSUE. INSPECTED #2 DAU AND FOUND THE CONNECTOR GUNKED. CLEANED CONNECTOR AND R+R DAU IN REF TO AMM 31 14 01. ALSO R+R LAV SMOKE PANEL AS PREVENTATIVE MX IN REF TO AMM 26 14 02.SDR SIMA20221025002Clamp · unsecureA/I BACK TO ORD DUE TO BLEED 1 LEAK DURING FLIGHT. EMERGENCY WAS DECLARED BUT WAS NOT OVERWEIGHT. FLT CHG EQP AND CONTINUED-C/A-PERFORMED VISUAL AND LEAK INSPECTION OF DUCT AIR BLEED LINES OF SYSTEM 1 IAW EMB 145 AMM TASK 36-11-09. RE-TORQUED V-BAND CLAMPS AT SDR SIMA20221025001Lamp · inoperativeAFT CEILING LINING EMERGENCY LIGHT INOP-C/A-RAR AFT CEILING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.SDR V0XD20221118001Floorbeam · corrodedCORRODED FLOOR BEAM CROSS SECTION UNDER FLOOR BOARD 231 FF AT FRAME 20. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM CROSS SECTION (P/N: 145-20600-603) UNDER FLOOR BOARD 231 FF IAW EMB 145 SRM 51-40-02.SDR SIMA20221024002None · noneAFT CARGO DOOR FRAME 65 GUSSET IS CORRODED.(LEVEL 2 CORROSION) (MAJOR REPAIR)-C/A-FRAME 65 REPAIRED IAW ERS-EM-53MR-4660.SDR SIMA20221021002None · brokenFLT ATTD FLASH LIGHT HOLDER FWD CABIN BROKEN-C/A-RAR OF FLASHLIGHT CLIP ABOVE FLT ATTD SEAT OPS CHK GOOD IAW CMM 25-60-14SDR SIMA20221021001None · noneSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. END.SDR SIMA20221021003Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHTS OUT-C/A-RAR EMERGENCY LIGHT LAMP AS IN EMB145 AMM 33-50-09. OPS CK GOODSDR HNAA2022102400270Unknown · fumesUPON TAXI OUT ELECTRONIC FUMES SMELLED FROM ROW 7 O/H BIN AREA BY_FA AND PAX. RAN A/C PACKS NO SMELL NOTED. SUSPECT PAX WAS USING VAPESDR HNAA2022102400269Ballast · failedLAV SMOKE ALARM AFTER T/O & SMOKE WAS SEEN BY F/A & SMELLED IN COCKPIT. RTF WITH TOUCHDOWN SINK RATE OF 300 FPM. SMOKE DID CLEAR AFTER 5 MINUTES. INSPECTED LAV LIGHTS AND WIRING. FOUND UPPER LAV LIGHTS INOP, RESEATED BALLAST. LAV LIGHTS OPS CHECK GOOD . NO ESDR SIMA20221020001None · noneWING ANTI ICE/PACK 2 BLEED FAIL. ICING CONDS INTO YUL. RETURN TO ORD. EMERGENCY DECLARED. NOT OVR WT LNDNG. FLT CONT WHILE T/S PACK 2 FAIL AND OVERHEAT (REF NRWC# 670-ORD-06037) FOUND #2 RECIRC FAN MUFFLER BLOWN/DAMAGED-C/A-RAR #2RECIRCULATION FAN MUFFLER IAW SDR HNAA2022102500271Door Sill · corrodedE937971 - SSI 53-30-48 CORROSION ON CARGO DOOR LOWER SILL ... REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW EMB145 SRM 51-40-02.SDR SIMA20221017001None · unserviceableFIRST 3 CABIN FLOOR EMERGENCY LIGHTS INOP.-C/A-RAR BATTERY CHARGER ASSY (2) AS PER EMB 145 AMM 33-50-04 OPS CHECK GOODSDR HNAA2022102500274Skin · crackedE937122 - THERE IS A POSSIBLE SKIN CRACK AT A RIVET, AT FR78, STGR 6R-5R .... ACCOMPLISHED REPAIR OF SKIN CRACK AT A RIVET BY CUT OUT AND INSTALLATION OF BUSHING AT FR78, STGR 6R-5R IAW EO1-53-22-0211.SDR SIMA20221015003Lamp · inoperativeROW 16 CEILING EMERGENCY LIGHT INOP-C/A-RAR ROW 16 CEILING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.SDR SIMA20221015002Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPC GOOD. END.SDR SIMA20221015001Lamp · inoperativeR/H OVERWING EMERGENCY LIGHT INOP-C/A-REPLACED EMERGENCY LIGHTY LAMP IAW AMM 33-50-10.OPS CHECK GOODSDR HNAA2022102500294Skin · corrodedE938783 - INTERIOR PAX, THE SKIN AT THE BASE OF THE AFT HEATED NIPPLE HAS CORROSION. SSI 53-20-07 .... ACCOMPLISHED REPAIR OF CORROSION ON INTERNAL FUSELAGE SKIN AROUND HEATED NIPPLES BTW FR 57-58 IAW EO1-53-22-0210 AND ETD# ETD2022-145-030530. SEE NRTC# E9383SDR HNAA2022102500282Skin · corrodedE938371 - SSI 53-20-27 INTERIOR PAX, THE SKIN AT THE BASE OF THE FWD HEATED NIPPLE HAS CORROSION .... ACCOMPLISHED REPAIR OF CORROSION ON INTERNAL FUSELAGE SKIN AROUND HEATED NIPPLES BTW FR 57-58 IAW EO1-53-22-0210 AND ETD# ETD2022-145-030530.SDR SIMA20221013002None · crackedMAIN DOOR EMERGENCY LIGHT ASSY CRACKED-C/A-RAR MAIN DOOR EMERGENCY LIGHT ASSY MAIN DOOR EMERGENCY LIGHT ASSY IAW EMB AMM 25-23-04-000-801-A AND 25-23-04-400-801-A. OPC GOODSDR SIMA20221013001None · noneAFT EMERGENCY FLASHLIGHT CRADLE WILL NOT CHARGE. MEL 25-32 AUTH# 100080M-C REF AML PG 4913838 ITEM 2-C/A-RAR AFT FA EMERGENCY FLASHLIGHT ASSY IAW EMB 145 AMM 33-50-16 AND ETN-EM-33-059R1 OPS CHECK GOOD MEL RESTOREDSDR HNAA2022101200268Dau · faultedEMERGENCY DECLARED LH FUEL TANK WENT TO ZERO DURING CRUISE FUEL IMBALANCE EICAS PRESENTED SUSPECTED FUEL LEAK. VERIFIED MEL CONDITIONS ARE MET USING SPR PANEL. R/R'D FOR MAINT CONVENIENCE DAU #1 IAW 31-41-01-000/ 400-801-A AND REPEATER IAW 28 23-08-000/400-80SDR HNAA2022102500280Guide · damagedE938354 - CDT INTERIOR CABIN, THE LOWER LH COCKPIT TO PAX PARTITION GUIDE PIN HOLE IS ELONGATED ..... COMPLETED INSTALLATION OF INTERIOR CABIN LOWER LH COCKPIT TO PAX PARTITION GUIDE PIN HOLE DOUBLER IAW EMB 145 SRM 53-21-02 SECTION 4 FIG 204SDR HNAA2022101200267Warning Message · illuminatedBLEED 2 LEAK MESSAGE DURING FINAL, MESSAGE INTERMITTENT, EXTINGUISHED AFTER LANDING. INSPECTED #2 BLEED SYSTEM FOR LEAKS NO LEAKS FOUND. PERFORMED AIR BLEED SYSTEM OPERATIONAL TEST IAW AMM 36-00-00-700-803-A.COULD NOT DUPLICATE LEAK ON #2 BLEED SYSTEM AT THISDR HNAA2022102500285Floorbeam · corrodedE938489 - CORROSION ON CROSS FLOOR BEAM AT FRAME 18 PREVIOUS REPAIR .... REMOVED AND REPLACED CROSS BEAM AT FR 18 IAW EMB 145 SRM 51-40-02.SDR HNAA2022102500272Yoke · crackedE937935 - LH ENGINE LOWER FWD YOKE IS CRACKED AT ENGINE MOUNT .... REMOVED AND REPLACED LH ENGINE PYLON YOKE FITTINGS IAW PIEDMONT FCD1-54-21-0015.SDR HNAA2022102500279Floor Support · corrodedE938024 - INTERIOR PAX, THERE IS CORROSION ON THE LH FLOOR SILL, AT FRAME 52-57. PREVIOUSLY BLENDED AREA .... BLENDED AREA ON LH FLOOR SILL BTW FR52-57 FOUND TO BE BEYOND ALLOWABLE LIMITS IAW EMB 145 SRM 53-24-10. REMOVED UNSERVICEABLE LH FLOOR SILL BTW FR 52SDR SIMA20221009002None · unserviceableAFT EMERGENCY FLASHLIGHT HOLDER IS BROKEN AND LIGHT IS NOT CHARGING CORRECTLY-C/A-REPLACED AFT CABIN EMERGENCY FLASHLIGHT ASSEMBLY IAW EMB 145 MM 33-50-16. OPS CHECK GOOD.SDR HNAA2022102500293Angle · corrodedE938535 - CORROSION IN GALLEY AREA ON CENTER HAT BEAM ANGLE PANEL AT FRAME 23 .... RAR GALLEY AREA ON CENTER HAT BEAM ANGLE PANEL AT FRAME 23 IAW EMB 145 SRM 51-40-02SDR HNAA2022102500291Gusset · corrodedE938526 - CORROSION IN GALLEY AREA ON DIAMOND GUSSET AT FRAME 20 .... RAR GALLEY AREA DIAMOND GUSSET AT FRAME 20 IAW EMB 145 SRM 51-40-02SDR HNAA2022102500290Beam · corrodedE938516 - CORROSION IN GALLEY AREA ON CENTER BEAM GUSSET .... REMOVED CORRODED GALLEY AREA CENTER BEAM GUSSET AND INSTALLED SERVICEABLE GUSSET IAW EMB 145 SRM 51-40-02, EMB 145 CPM 51-21-06, PIEDMONT BULLETIN 51-02.SDR HNAA2022102500289Floor Support · corrodedE938503 - CORROSION ON LH OTBD # 1 FLOOR SILL .... REMOVED CORRODED LH OTBD # 1 FLOOR SILL, POSITIONED DRILLED AND INSTALLED SERVICEABLE FLOOR SILL IAW EMB 145 SRM 51-40-02, 51-20-03.SDR HNAA2022102500288Floorbeam · corrodedE938498 - SSI 53-20-11 CORROSION ON LH BEAM AT FRAME 20 .... REPAIRED LH OMEGA BEAM AT FR 20 IAW EMB 145 SRM 53-00-10 ITEM 2 FIGURE 201 SHEET 1.SDR HNAA2022102500284Floor Support · corrodedE938457 - ELONGATED SCREW HOLE AND CORROSION ON PASSENGER DOOR ENTRY AFT FLOOR BOARD SUPPORT ....REMOVED AND REPLACED PASSENGER DOOR ENTRY AFT FLOOR BOARD SUPPORT IAW EMB145 SRM 51-40-02SDR HNAA2022102500283Floor Support · corrodedE938456 - CORROSION ON PASSENGER DOOR ENTRY FWD FLOOR BOARD SUPPORT .... REMOVED AND REPLACED PASSENGER DOOR ENTRY FWD FLOOR BOARD SUPPORT IAW EMB145 SRM 51-40-02,SDR HNAA2022102500281Shear Tie · corrodedE938370 - INTERIOR PAX, THERE IS A SHEAR CLIP THAT HAS CORROSION, ON FR 58, BETWEEN STGR 19R-20R. SSI 53-20-43 .... REMOVED AND REPLACED SHEAR CLIP AT FR 58 BTW STGR 19R-20R IAW EMB 145 SRM 51-40-02SDR HNAA2022102500295Frame · crackedE939229 - FR 72 CRACKED BETWEEN STGR 17L AND STGR 16L .... REMOVED AND REPLACED FR 72 LH SECTION IAW EMB-145 SRM 51-40-02.SDR HNAA2022102500292Floor Support · corrodedE938533 - CORROSION ON SERVICE DOOR AFT FLOOR SILL WITH SOME AREAS PREVIOUS REPAIRED .... REMOVED DAMAGED SERVICE DOOR AFT FLOOR SILL AND INSTALLED NEW SERVICEABLE AFT SILL IAW EMB 145 SRM 51-40-02SDR HNAA2022102500277Bracket · corrodedE937854 - CORROSION ON BAGGAGE DOOR LOWER L BRACKET .... REMOVED AND INSTALLED NEW AND SERVICEABLE BAGGAGE DOOR LOWER 'L' BRACKET IAW EMB-145 SRM 51-40-02.SDR HNAA2022102500273Bushing · not reportedE940139 - PCR - ACCOMPLISH FCD1-54-21-0017 REV C - RIGHT PYLON - REPLACEMENT OF FORWARD PYLON LINKAGE AND BUSHINGSSDR SIMA20221007001Lamp · inoperativeDURING PS-1 CHECK, FOUND RH OVER WING EMERGENCY LIGHT INOP-C/A-RAR OVER WING EXTERIOR EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-07. OPC GOODSDR HNAA2022102500287Floorbeam · corrodedE938496 - CORROSION ON CROSS FLOOR BEAM AT FRAME 20 PREVIOUS REPAIR .... REMOVED AND REPLACED CENTER AISLE CROSS FLOOR BEAM AT FR 20 IAW EMB 145 SRM 51-40-02 AND PIEDMONT BULLETIN 53-3.SDR V0XD20221006002Floor Support · corrodedCORROSION ON FLOOR BEAM 3 PLACES BL-0 FR 19-23: CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM AT BL-0 FR 19-23 IAW EMB 145 SRM 51-40-02SDR V0XD20221006001Gusset · corrodedCORROSION ON GUSSETT BL-0 FR 20-21: CORRECTICE ACTION: REMOVED AND REPLACED GUSSETT IAW EMB 145 SRM 51-40-02SDR HNAA2022102500286Seat Track · corrodedE938494 - CORROSION ON LH INBD # 1 SEAT TRACK .... REMOVED AND REPLACED LH INBD #1 SEAT TRACK IAW EMB 145 AMM 53-01-06.SDR HNAA2022100500266Bleed Valve · faultedBLEED 2 VALVE FAILURE ON T/O POWER ( C/W RMM 36-11-05) T/S FIM 36-11-00-810-806-A STEPS 1 2 3 20 21 AND 22 R/R #2 HIGH STAGE PRESSURE SWITCH IAW AMM 36-11-07. OPS CHECK GOOD. NO OTHER DEFECTS NOTEDAT THIS TIME. CLEAR MEL 36-1-3.OK FOR SERVICE.SDR HNAA2022102500276Door Frame · corrodedE937764 - SSI 52-21-06 CORROSION ON LOWER FRAME AROUND RUBBER STOP ON RH EMERGENCY ESCAPE HATCH ... 4 REMOVED AND REPLACE LOWER FRAME AROUND RUBBER STOP ON RH EMERGENCY ESCAPE HATCH IAW EMB145 SRM 51-40-02 AND AMM 52-21-00.
Back to Embraer EMB-145LR