Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202210043001Lamp · inoperativeRH OVERWING EMERGENCY LT INOP-C/A-RAR OVERWING EMERGENCY LIKGHT LAMP IAW EMB 145 AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR V0XD20221003005Bracket · corrodedCORROSION ON ANGLE BRACKET ON BL-0 ON Z CHANNEL UNDER FLOOR PANEL 242AF: REMOVED AND REPLACED BRACKET IAW EMB 145 SRM 51-40-02SDR V0XD20221003004Cup · corrodedDURING REMOVAL OF LAV DRAIN VALVE CORROSION FOUND ON PAN/CUP FLANGE: REMOVED AND REPLACED PAN CUP ASSEMBLY IAW EMB 145 SRM 51-40-02SDR SIMA20221002002Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-07. OPC GOODSDR SIMA20221002001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPC GOOD. END.SDR HNAA2022102500278Reinforcement · corrodedE937968 - SSI 53-30-07 CORROSION ON INTERNAL FUSELAGE LOWER SKIN REINFORCEMENT PLATE BETWEEN FRAME 61-63 STRINGERS 21L-19L .... REMOVED AND INSTALLED SERVICEABLE DOUBLER AT FR 62-63, STGR 19L-20L IAW EMB 145 SRM 51-40-02 ALSO REMOVED AND INSTALLED THE FABRICATSDR HNAA2022102500275Reinforcement · corrodedE937355 - CORROSION ON 3 TRIANGLE REINFORCEMENTS ON LH ENGINE INTERNAL UPPER COWLING .... RAR 3 TRIANGLE REINFORCEMENTS ON LH ENGINE UPPER COWLING INTERNAL STRUCTURE IAW EMB 145 SRM 51-20-01 AND 51-40-02.SDR SIMA20221001001None · nonePACK 1 AND 2 CLOSED ON EICAS / EMERGENCY NOT DECLARED A/C SWAP. FLIGHT CONTINUED. -C/A-PACK LEAKS FOUND ON PACK 1 AND PACK 2. RAR PACK 1 DUCT FROM THE DUAL HEAT EXCHANGER IAW EMB145 AMM 21-51-02. SEE ITEM 2 THIS AML PAGE FOR #2 PACK.SDR V0XD2022100101Brace · corrodedL/H LOWER SIDE BRACE HAS SIGNS OF CORROSION ON SIDE BRACE LOWER LUG AND BUSHING BORE. CORRECTIVE ACTION: REMOVED AND REPLACED L/H MAIN BRACE STRUT ASSY. (2309-3500-503) IAW EMB 145 AMM 32-10-03.SDR SIMA20220929001Transducer · unserviceableBRAKE DEGRADE CAUTION ILLUMINATED ON FINAL DESCENT AT GEAR DROP. RIGHT INBOARD BRAKE APPEARS TO HAVE NOT ENGAGED." DURING TROUBLESHOOTING AND READING NVM, SUSPECT #3 BRAKE PRESSURE TRANDUCER TO BE FAULTY AND CAUSING THE PRESSURE PULSE TEST TO FAIL IN FLIGHT.-CSDR SIMA20220928001None · noneCARGO SMOKE INDICATION ON FINAL DESCENT DECLARED EMERGENCY NO INJURIES REPORTED.-C/A-RAR BAG COMPARTMENT HIGH RATE EXTINGUISHER BOTTLE AMM 26-23-01 SEE LGPG 4791650/2 FOR RAR OF METERING BOTTLESDR V0XD2022102800001Threshold · corrodedSIGNS OF CORROSION UNDER THE SERVICE DOOR THRESHOLD. CORRECTIVE ACTION: REMOVED AND REPLACED SERVICE DOOR THRESHOLD IAW EMB 145 SRM 51-40-02.SDR SIMA20220925002Inverter · inoperativeCOCKPIT STEPUP EMERGENCY EXIT SIGN INOP-C/A-RAR INVERTER #1 IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A NO FIX, INVERTER BAD FROM STOCK. INSTALLED NEW INVERTER OPS CHECK GOOD.SDR SIMA20220925003Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20220923001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA20220923002Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. RAR OVERWING LIGHT ASSEMBLY IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR V0XR20221101AV2Cap · corrodedLEFT WING MLG AFT LOWER TRUNNION CAP CORRODED AND SCOREDSDR V0XR20221101AV1Cap · corrodedLEFT WING MLG FWD LOWER TRUNNION CAP CORRODED AND SCOREDSDR V0XR20221031AV4Trunnion · corrodedRIGHT WING MLG AFT LOWER TRUNNION CAP IS CORRODED AND SCOREDSDR V0XR20221031AV3Trunnion · corrodedRIGHT WING MLG FWD LOWER TRUNNION CAP CORRODED AND SCOREDSDR V0XR20221031AV2Trunnion · corrodedRH WING MLG FWD UPPER TRUNNION CORRODED AND SCOREDSDR V0XR20221031AV1Trunnion · corrodedRH WING MLG AFT UPPER TRUNNION HAS CORROSION AND SCORING REPAIRED IAW EMBRAER ETD 2022-145-031079 REV :/SDR V0XR20221019001Trunnion · corrodedL/H WING FWD UPPER TRUNNION HAS SCORING AND CORROSION REPAIRED IAW EMB 145 SRM 57-51-07-ADSDR SIMA20220921001None · missingEMERGENCY FLASHLIGHT MISSING IN REAR CABIN.-C/A-REPLACED EMERGENCY FLASHLIGHT AS REQUIRED IAW STANDARD MTX PRACTICES.SDR V0XD2022092102Plate · corrodedCORROSION ON GUSSET PLATE RBL Y-479 FR 22- CORRECTIVE ACTION: REMOVED CORROSION FROM GUSSET AND FOUND TO BE 100% OUT OF LIMITS REMOVED AND REPLACED PART IAW EMB 145 SRM 51-40-02SDR V0XD2022092101Floorbeam · corrodedCORROSION ON LATERAL FLOOR BEAM UNDER FLOOR BOARD 231FF FR 20- CORRECTIVE ACTION: REMOVED BEAM PN 145-20600-003 AND REPLACED WITH NEW BEAM PN 145-20600-603 (CARBON FIBER) IAW EMB 145 SRM 51-20-03SDR SIMA20220919001Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH OVERWING EMERGENCY LIGHT LAMP IAW AMM 35-50-10SDR HNAA2022091900265Unknown · odorPLASTIC BURNING SMELL OBSERVED AROUND ROW 3 INFLIGHT. INSP CABIN AND CKP FOR BURN SMELL. RAN PACKS 1&2 WITH APU AND ENG 1&2 BLEEDS ON AND OFF INSP LIGHTING IN CABIN AND GALLEY NO DEFECTS OR ODORS FOUND AT THIS TIME OK FOR SERVICESDR 4DPA2022091700002Filter · dirtyCREW REPORTED-BLD 1 OVTEMP WARNING APPEARED ON DEPARTURE DURING AFTER TAKEOFF FLOW FOLLOWING TURNING OFF THE APU. RETURNED TO MIA. CORR ACTION-MX CLEANED #1 BLEED FAN AIR VALVE FILTER AND PERFORMED OPS CHECK OF BLEED SYSTEM AND WING A/I BOTH PASSED NDN.SDR 4DPA202209170001Duct · unsecureCREW REPORTED-PACK 2 OVLD CAUTION APPEARED INFLIGHT AND BLD 2 VLV FAIL APPEARED INFLIGHT. RAN QRH AND DESCENDED TO FL240 PER QRH. CORR ACTION-MX C/W ENGINE #2 RUN WITH FLIGHT CREW, BLEED VALVE WAS OPERATING AS IT IS SUPPOSE TO, OPS CHECK GOOD. MX DISCOVERED BLSDR SIMA20220916001None · unserviceableICE COND-A/I INOP WARNING AND WG A/ICE FAIL CAUTION ILLUNINATED IN CLIMB FL 200 , TEMP-13 SAT TAT WING ICE PROTECTION PUSHBUTTON DID NOT ILLUMINATE . EXITED ICE CONDITION IN FLIGHT AND RAN QRH WITH NO EFFECT. "TRANSFERRED FROM AML PAGE 4922319 ITEM 1"-C/A-RAR SDR V0XD20220915001Bracket · corrodedCORROSION ON LBL Y=479.0 BRACKET AFT OF LATERAL FLOOR BEAM: CORRECTIVE ACTION: FABBED NEW ANGLE REPAIR AND FILLER INSTALLED ON LBL Y=479.0 AFT OF LATERAL FLOOR BEAM IAW EMB 145 SRM 53-00-10 AND SRM 51-30-01SDR V0XR20221018AV1Firewall · crackedAPU FIREWALL CRACKED AT FASTENER AT THE 9OCLOCK POSITION. REPAIRED IAW EMB 135/145 SRM 53-32-13-RESDR V0XR20220930001Floor Support · corrodedCORROSION FOUND ON FLOOR SUPPORT BEAM BL0 BETWEEN FR 57 AND FR 61.SDR V0XD20220913002Threshold · corrodedSIGNS OF CORROSION AT AFT CARGO THRESHOLD BET FR 65 AND 67, CORRECTIVE ACTION: REMOVED AND REPLACED BEAM, LOWER FRAME DOOR SILL IAW EMB 145 SRM 51-40-02SDR V0XD20220913001Floor Support · corrodedSIGNS OF CORROSION ON LH FLOOR SILL STR 15L BETWEEN FR 58- FR 60. CORRECTIVE ACTION: REMOVED AND REPLACED SUPPORT, FLOOR SILL AND SPLICE ON LH FR 58- FR 60 STR 15L IAW EMB 145 SRM 51-40-02.SDR HNAA2022091300264None · nonePDIS 906 36-12 2480401 12SEP22 CLT CLOSE
EXHAUST FUMES WHEN PACK 1 OPERATING ON APU BLEED
FACT 13SEP22 02:13 MDT
INSPECTED AND FOUND C/P AT APU BLEED VALVE CONNECTED. RAN APU BLEED AND BOTH PACKS FOR 20 MINS. NO EXHAUST SSDR HNAA2022091200259None · nonePDIS 620 30-31 2696001 11SEP22 CLT CLOSE
PITOT 1 INOP MESSAGE IN FLIGHT, WAS NOT IN ICING. WENT AWAY WHEN LANDING
FACT 11SEP22 21:25 CLT
UPON ARRIVAL TO A/C NO EICAS OR CMC MESSAGES WERE DISPLAYESDR SIMA20220911001Lamp · inoperativeUPPER LH EMERGENCY LIGHT INOP-C/A-RAR UPPER LH EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPC GOODSDR SIMA20220910001Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. RAR LH OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR V0XD20221011001Floor Support · corrodedLH FLOOR SILL AT FR. 60 NEXT TO SHROUD IS CORRODED. CORRECTIVE ACTION: REMOVED AND REPLACED LH FLOOR SILL (P/N: 145-25422-001) AT FR. 60 IAW EMB 145 SRM 51-40-02.SDR HNAA2022091200258None · nonePDIS 638 27-22 2677131 09SEP22 CLT CLOSE
RUD SYS 2 INOP INFLIGHT
FACT 09SEP22 10:53 CLT
C/W FIM 27-22-00-810-802A STEPS 1,2,3 R/R W RUDDER SYSTEMS PRESSURE SWITCH IN REF TO AMM 27-23-04 OPS AND LEAK CHECK GOOD OK FOR SERVICESDR SIMA20220909002None · noneFA FLASHLIGHT CRADLE BROKEN-C/A-RAR FA FLASHLIGHT ASSEMBLY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPC GOOD. END.SDR SIMA20220909003None · noneMAIN PASSENGER DOOR NOT OPENING PROPERLY-C/A-LUBED ON MAIN DOOR FRAME ROLLERS REF AMM 53-21-02. PERFORMED OPC OPEN/CLOSE AND INTERNAL ACTUATING HANDLE ON MAIN DOOR REF AMM 52-18-00. OPC GOOD AT THIS TIME.SDR SIMA20220909001Lamp · inoperativeRH OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH OVER WING EMERGENCY LIGHT LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20220908001None · noneDURING PS-2 FOUND FWD FA EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-RAR FWD FA EMERGENCY FLASHLIGHT IAW EMB 145 AMM 33-50-16. NO FURTHER DEFECTS NOTED.SDR 4DPA2022090600003Control Unit · failedCREW REPORTED MAIN PITCH TRIM FAILED ENROUTE. MX TROUBLE SHOT TO BAD HSCU. R&R'D HSCU OPS TEST GOOD.SDR SIMA20220906001None · unserviceableBRAKE DEGRADED EICAS MESSAGE. LITTLE TO NO BRAKING NO RIGHT HAD SIDE #3 BRAKE NO TEMP RISE-C/A-RAR BRAKE CONTROL UNIT IAW AMM 32-41-02 OPC GOOD, BRAKE SYSTEM AND #3 BRAKE TEMP INDICATION TEST GOOD IAW AMM 32-41-00SDR HNAA2022090700257Fadec · faultedHUNG START OF #2 ENG FOLLOWED BY EXHAUST FUMES. OIL NOTED DRIPPING FROM #2 LOWER COWLING. RAN E2 OFF FADEC A WITH NO DEFECTS NOTED. RAN E2 OFF FADEC B WITH HUNG START MULTIPLE TIMES. R/R FADEC 2B IAW AMM 73-22-01NO FIX. NO SIGN OF OIL LEAK DURING E2 ENGINE RSDR HNAA2022090700256Engine · hung startENGINE 2 HUNG START, AFTER START WAS ABORTED FUMES WERE NOTED IN CABIN AND FLIGHT DECK. INSPECTED #2 ENGINE FOR POSSIBLE FUEL LEAK. NONE FOUND. PERFORMED #2 ENGINE START FROM APU BLEEDS, PACKS OFF, AND #1 ENGINE BLEEDS, WITH PACKS OFF. BOTH TIMES ENGINE START
Back to Embraer EMB-145LR