SDR SIMA20220211004None · noneTHIS IS A SUPPLEMENTAL SHOWING THE FWD CARGO SMOKE DETECTOR WAS REPLACED P/N 473597-13 S/N 0094. BAGGAGE SMOKE WARNING ON DURING FLIGHT. C/A BLEW BOTTLES.MECH EMERGENCY DECLARED AT 14,000FT/ BAGG EXT BUTTON PRESSED PER QRH. REST OF QRH CW-C/A-RAR BOTH BAGGAGE SDR SIMA20220211002None · noneBOTH OVERWING EMERGENCY EXIT SIGNS AND FLOOR STRIP INOP-C/A-RAR #5 EMERGENCY LIGHT DC/AC INVERTER IAW EMB 145 AMM 33-50-11. OPC GOODSDR SIMA20220211003None · noneCABIN AFT EMERGENCY FLIGHTLIGHT BRACKET IS BROKEN-C/A-DEFERRED PER MEL 25-32., AUTH# 020124M-C.SDR HNAA2022021400077Not Reported · not reportedPDIS 907 27-41 2476641 10FEB22 CLT CLOSE
PTRIM MAIN INOP DISPLAYED ON EICAS.
FACT 10FEB22 17:27 CLT
PERFORMED FIM TASK 27-43-00-810-801-A STEP 1.NO MESSEGES ON EICAS.PERFORMED OPS IAW EMB AMM 27-40-00-700-802-A/500.OPS CHECK SDR HNAA2022021400076Not Reported · not reportedNDIS 637 33-50 0045670 10FEB22 RIC CLOSE
EMERGENCY LIGHT WIRE NOT ATTACHED TO CONNECTOR AT FLOOR PROXIMITY LIGHT AT 9A
FACT 10FEB22 10:54 RIC
INSTALLED NEW CONTACT AND CONNECTOR IN RESDR SIMA20220210002None · noneLAVATORY EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-REMOVED AND REPLACED BROKEN EMERGENCY FLASHLIGHT HOLDER AT LAVATORY IAW EMB 145 AMM 33-50-16 AND ETN-EM-33-059 R1. OPC GOOD.SDR SIMA20220210001None · noneE899729-LH ENGINE YOKE FORWARD LINKAGE FITTING IS CRACKED. (MAJOR REPAIR)-C/A-REPLACED YOKE FITTING IAW ERS-EM-54MR-698.SDR HNAA2022021000075Not Reported · not reportedPDIS 656 27-62 2706562 09FEB22 CLT CLOSE
IN FLT SPEED BRAKE HANDLE TO CLOSE, SPOILER FAIL MSG, A/C ROLLED RT AND AUTO PILOT FAILED. RAN QRH WITH SPOILERS REMAINING CLOSED REST OF THE FLIGHT DURING DECENT ABOUT 13K FT
FACT 09FEB22 16:08 CLSDR SIMA20220209001None · noneROW 8A EMERGENCY FLOOR STRIP WONT ILLUMINATE ORIGINAL LOGPAGE 4715621 ITEM 3 MEL 3323 - AUTH# 02-53-C-C/A-RAR ROW 8A EMERGENCY FLOOR LT STRIP IAW EMB AMM 33-50-12-000-801-A AND 33-50-12-400-801-A. OPS CHECK GOOD. MEL RESTORED. END.SDR HNAA2022020900070Not Reported · not reportedPDIS 626 30-10 2530291 08FEB22 ALB CLOSE
WING ANTI ICE FAIL MSG ON CLIMB-OUT
FACT 08FEB22 13:50 ALB
TROUBLESHOT WG A-ICE FAIL ON EICAS IAW EMB 145 FIM 30-11-00-810-810-A. FOUND CANNON PLUG ON PRESSURE DROP SWITCH DIRTY.SDR HNAA2022022300084Not Reported · not reportedRIGHT WING RIB 21 UPPER FLANGE IS CRACKED (MARKED INSIDE PCA AREA) .... PERFORMED CUTOUT OF DAMAGE TO RH WING RIB 21 AND FABRICATED, PREPPED, AND INSTALLED REPAIR DOUBLER, REPAIR FILLER, AND SHIM IAW EMB 145 SRM 57-20-07 ITEM 4 FIGURE 203 AND EO1-57-22-0009.SDR HNAA2022020900071Bolt · shearedCAPTAIN'S RUDDER PEDAL EASILY COMES OFF TRACK. FOUND 2 BOLTS SHEARED FROM RUDDER PEDAL GUIDE REGULATOR. REMOVED SHEARED BOLTS AND INSTALLED NEW BOLTS IN REF TO AMM 20-10-01 AND SAFETIED IN REF TO AMM 20-10-02. PERFORMED OPS CHECK TO THE PEDAL ACTUATOR IN REFSDR HNAA2022020900069Not Reported · not reportedPDIS 649 34-32 2749062 07FEB22 CLT CLOSE
ON APPROACH TO FAY, BOTH LOC DROPPED OFF WITH RED X ACROSS CDI, SIGNAL WAS VERY WEAK
FACT 07FEB22 17:38 CLT
PERFORMED VOR/ILS/GS/MB OPS CHECK IAW SDR HNAA2022020900068Not Reported · not reportedPDIS 629 36-11 2706101 07FEB22 ISP CLOSE
HS 1 VLV FAIL MSG DURING TAKE OFF ROLL. REJECTED TAKE OFF AT 65 KTS FULL THROTTLE
FACT 07FEB22 11:24 ISP
PERFORMED OPS TEST OF AIR BLEED SYS WITH CREW IAW AMM 36-00-00-700-803. OPS CHESDR HNAA2022022300112Not Reported · not reportedE901608 - SERVICE DOOR AFT SILL CORRODED .... REMOVED AND REPLACED SERVICE DOOR CUTOUT AFT SILL IAW EMB145 SRM 51-40-02. RESTORED PROTECTIVE COATING AS REQUIREDSDR SIMA20220205001None · none"TRANSFERRED FROM NRWC 613-CMI-04165 ITEM 1" ROW 8A EMERGENCY LIGHT STRIP INOP-C/A-DEFERRED PER MEL 33-23. AUTH# 020053-CSDR HNAA2022022300088Not Reported · not reportedE898758 - CARGO DOOR INTERIOR WEBBING HAS MULTIPLE GOUGES .... RE-ACCOMPLISHED THREE PREVIOUS REPAIRS TO CARGO DOOR INTERIOR WEBBING IAW EMB145 SRM 52-30-01, ITEM 12, FIGURE 213 AND EO1-52-22-0015, AND ETD2022-145-001584REV A AND EO-1-05-22-0018SDR HNAA2022022300111Not Reported · not reportedE901506 - RH #1 (CENTER) FLOOR BEAM GUSSET CORRODED .... REMOVED AND REPLACED RH #1 (CENTER) FLOOR BEAM GUSSET IAW EMB145 SRM 51-40-02. RESTORED PROTECTIVE COATING AS REQUIREDSDR HNAA2022022300110Not Reported · not reportedE901499 - LH #2 OUTBOARD FLOOR SILL CORRODED .... REMOVED AND REPLACED LH #2 OUTBOARD FLOOR SILL IAW EMB145 SRM 51-40-02. SEE TURNOVER FOR DETAILS.SDR HNAA2022022300095Not Reported · not reportedE898854 - RH #2 FLOORBOARD SUPPORT CORRODED IN MULTIPLE AREAS .... RH #2 FLOORBOARD SUPPORT CORRODED IN MULTIPLE AREASSDR HNAA2022022300096Not Reported · not reportedE898855 - CENTER #4 FLOORBEAM GUSSET CORRODED IN ONE SPOT .... RAR CENTER #4 FLOOR BEAM GUSSET IAW EMB-145 SRM 51-40-02.SDR SIMA20220131002None · noneAFT CABIN EMERGENCY FLASHLIGHT MISSING ORG LOG PAGE 4799117 ITEM #1 REF MEL 25-32 AUTH # 010400M-C/A-INSTALLEED EMERGENCY FLASHLIGHT IAW AML 33-50-16 OPS CHECK GOOD MEL RESTOREDSDR SIMA20220131001None · noneFA EMERGENCY FLASHLIGHT HOLDER BRACKET CRACKED-C/A-RAR FA FLASHLIGHT HOLDER BRACKET IAW EMB 145 CMM 25-60-14.SDR HNAA2022022300103Not Reported · not reportedE899182 - SSI 53-20-11 RH OMEGA BEAM IS CORRODED AROUND SCREW HOLE AT FR 19 .... INSTALLED SERVICEABLE REPAIR DOUBLER AT NUTPLATE HOLE ON RH OMEGA BEAM AT FR 19 IAW ETD2022-145-001841 AND PIEDMONT EO1-53-22-0014.SDR HNAA2022022300102Not Reported · not reportedE899181 - SERVICE DOOR FWD SILL IS CORRODED AT FWD END .... REMOVED AND REPLACED SERVICE DOOR FWD SILL IAW EMB 145 SRM 51-40-02. SEE WIP AND TASK FOR DETAILSSDR HNAA2022022300101Not Reported · not reportedE899178 - RH OMEGA BEAM GUSSET AT FR 22 IS CORRODED AT FWD SCREW HOLE.(PREVIOUS BLEND) .... REMOVED UN-SERVICEABLE RH OMEGA BEAM GUSSET AT FR 22, POSITIONED, DRILLED AND INSTALLED NEW SERVICEABLE RH OMEGA BEAM GUSSET AT FR 22 IAW EMB 145 SRM 51-40-02 AND EMB 1SDR HNAA2022022300092Not Reported · not reportedE898841 - LH FLOOR BEAM GUSSET CORRODED IN NUMEROUS AREAS BTWN FR 24-29 .... RAR LH # 2 FLOOR BEAM GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2022022300091Not Reported · not reportedE898840 - LH OUTBD FLOOR SUPPORT CORRODED IN IN NUMEROUS AREAS BTWN FR 24-29 .... REMOVED AND REPLACED LH #2 FLOOR SILL IAW EMB 145 SRM 51-40-02 AND 51-20-03SDR HNAA2022022300087Not Reported · not reportedE898655 - PILOTS BULKHEAD UPPER OTBD ATTACHMENT HOLE IS GOUGED ..... REPAIRED GOUGED AREA (BLENDED) ON PILOTS BULKHEAD UPPER OUTBOARD ATTACHMENT HOLE FOUND TO BE WITHIN LIMITS IAW EMB 145 SRM 53-21-02SDR HNAA2022022300099Not Reported · not reportedE898968 - LH #4 CABIN FLOOR SILL CORRODED .... RAR CABIN LH OUTBD FLOOR SILL #4 IAW EMB-145 SRM 51-40-02. SEE WIPS AND TASK FOR FURTHER INFORMATIONSDR HNAA2022022300100Not Reported · not reportedE898987 - RH #3 FLOORBOARD SUPPORT CORRODED IN MULTIPLE AREAS .... RAR RH #3 FLOORBOARD SUPPORT IAW EMB 145 SRM 51-40-02, 51-40-09SDR HNAA2022022300098None · noneE898857 - CENTER #2 FLOORBEAM GUSSET CORRODED IN MULTIPLE AREAS .... REMOVED CORRODED CENTER FLOOR BEAM GUSSET #2 AND INSTALLED SERVICEABLE CENTER FLOOR BEAM GUSSET #2 IAW EMB 145 SRM 51-40-02.SDR HNAA2022022300097Not Reported · not reportedE898856 - CENTER #1 FLOORBEAM GUSSET CORRODED IN MULTIPLE AREAS .... REMOVED CORRODED CENTER FLOOR BEAM GUSSET #1 AND INSTALLED SERVICEABLE CENTER FLOOR BEAM GUSSET #1 IAW EMB 145 SRM 51-40-02.SDR HNAA2022022300093Not Reported · not reportedE898842 - LH FLOOR BEAM GUSSET CORRODED IN NUMEROUS AREAS BTWN FR 29-35 .... REMOVED CORRODED LH FLOOR BEAM GUSSET BETWEEN FRAMES 29-35 AND INSTALLED SERVICEABLE LH FLOOR BEAM GUSSET BETWEEN FRAMES 29-35 IAW EMB 145 SRM 51-40-02SDR HNAA2022013100058Not Reported · not reportedPDIS 627 34-22 2753131 29JAN22 CLT CLOSE
IN FLIGHT FO'S PFD LOST ATT IND WITH ALL NUMBERS SHOWING RED. SELECTED AHRS REVERSION NO CHANGE. SWITCHED REVERSION KNOWT SHOW PFD ON MFD AND INFO APPEARED NORMAL WITH PFD BLANK
SDR SIMA20220128001Not Reported · not reportedWING RIB JUST O/B OF RIGHT PCA IS CRACKED AT RIVET THRU UPPER SKIN N900663 (MAJOR REPAIR)-C/A-REPAIRED WING RIB JUST O/B OF RIGHT PCA SRM 57-20-07-RE FIG 203.SDR SIMA20220128002Not Reported · not reportedN900664-WING RIB JUST O/B OF LEFT PCA IS CRACKED AT RIVET THRU UPPER SKIN (MAJOR REPAIR)-C/A-REPAIRED WING RIB JUST O/B OF LEFT PCA SRM 57-20-07-RE FIG 203.SDR HNAA2022022300094Not Reported · not reportedE898853 - RH #1 FLOORBOARD SUPPORT CORRODED IN MULTIPLE AREAS .... RAR RH #1 FLOORBOARD SUPPORT IAW EMB 145 SRM 51-40-02.SEE WIPS AND TASKS FOR DETAILS.SDR HNAA2022022300089Not Reported · not reportedE898787 - LH #7 CABIN FLOOR SILL CORRODED .... RAR LH #7 CABIN FLOOR SILL IAW EMB-145 SRM 51-40-02SDR HNAA2022022300090Not Reported · not reportedE898839 - LH OUTBD FLOOR SUPPORT CORRODED IN IN NUMEROUS AREAS BTWN FR 29-35 .... INSTALLED SERVICEABLE LH OUTBD FLOOR SUPPORT BTWN FR 29-35 IAW EMB145 SRM 51-40-09 AND 51-40-02SDR HNAA2022013100057Entertain Sys · odorC/B J15 POPPED.UPON RESETTING J15 FUMES WERE NOTED FROM CD PLAYER._P/C J15 MX RAN PACKS NO FUME NOTED. FOUND THE POWER WIRE WAS SWITCHED WITH THE GROUND WIRE FOR THE CD PLAYER ON THE DC TO DC CONVERTER. CORRECTED THE POWER WIRE AND GROUD WIRE INSTALLATION IN SDR SIMA202201287003Smoke Detector · false activationLAV SMOKE ALARM. INSPECTED LAVATORY, NO SMOKE OR FIRE DETECTED. LAVATORY SMOKE SYSTEM OPS CHECKS GOOD IAW AMM 26-14-00. NO DEFECTS NOTED.SDR SIMA20220127001None · noneAFT CABIN EMERGENCY FLASHLIGHT MISSING-C/A-FLIGHT CREW PLACARDED MISSINGCABIN EMERGENCY FLASHLIGHT "M PROCEDURES C/W" MEL 2532 AUTH# 010400M MOC 680820SDR SIMA20220126001None · noneREF MEL 33-27 AUTH #010377D-C LH FWD EMERGENCY LIGHT INOP AML PG 4813918-C/A-RAR BULB I/A/W AMM 33-50-10 OPS CHECK GOOD MEL ITEM RESTOREDSDR HNAA2022012700056Not Reported · not reportedPDIS 650 78-30 2594602 24JAN22 CHO CLOSE
E2 REV DISAGREE MSG ON EICAS DURING TAKEOFF ROLL
FACT 26JAN22 16:45 ROA
REMOVED AND REPLACED #2 THRUST REVERSER ASSY PER W/C 78-31-01. REMOVED AND REPLACED WIRING HARNESS W408 PER AMM 78SDR SIMA20220124002None · noneEMERGENCY LIGHT ON SERVICE DOOR NOT ILLUMINATING AND WIRE BROKE OFF AT BULB.-C/A-REMOVED AND REPLACED SERVICE DOOR EXTERNAL EMERGENCY LIGHT ASSY IAW EMB 145 AMM 33-50-10. OP CHECKED GOOD.SDR HNAA2022012500055Not Reported · not reportedPDIS 686 30-21 2573953 24JAN22 CLT ASSGN
E1 A/I FAIL MSG
FACT 22JAN22 01:20 ROA
FOUND E1 A/I OVERPRESS MESSAGE ON CMC. R&R'D E1 PRES SURE TRANSDUCER IAW AMM 30-21-06-000/400-801-A. OPS CK SATISFACTORY. OK FOR SERVICE AT THIS TSDR SIMA20220124001None · noneAFT CABIN EMERGENCY FLASHLIGHT WILL NOT CHARGE-C/A-RAR AFT CABIN EMERGENCY FLASHLIGHT ASSEMBLY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPS CHECK GOOD. END.SDR SIMA20220123001None · noneAFT CABIN EMERGENCY FLASHLIGHT INOP-C/A-RAR AFT CABIN EMERGENCY FLASHLIGHT ASSY IAW EMB 145 33-50-16. OPC GOOD.SDR HNAA2022022300085Not Reported · not reportedE898270 - RH ENGINE UPPER COWLING RIB GUSSET FWD OF ANTI/ICE ACCESS PANEL CORRODED .... REMOVED AND REPLACED RH ENGINE UPPER COWLING RIB GUSSET, FORWARD OF ANTI/ICE ACCESS PANEL ,IAW EMB145 SRM 51-40-02.