What was found
E901506 - RH #1 (CENTER) FLOOR BEAM GUSSET CORRODED .... REMOVED AND REPLACED RH #1 (CENTER) FLOOR BEAM GUSSET IAW EMB145 SRM 51-40-02. RESTORED PROTECTIVE COATING AS REQUIRED
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E901506 - RH #1 (CENTER) FLOOR BEAM GUSSET CORRODED .... REMOVED AND REPLACED RH #1 (CENTER) FLOOR BEAM GUSSET IAW EMB145 SRM 51-40-02. RESTORED PROTECTIVE COATING AS REQUIRED