Embraer EMB-145XR
Service difficulty reports · 9,191
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20251024052Floor Support · crackedFRAME 65-69 FLOOR SILL CRACKED AT RBL 29 EVALUATED SILL AT FRAME 65-69 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FLOOR SILL FRAME 65-69.SDR JJBA20251024051Floor Support · corroded#1 FLOOR SILL HAS CORROSION FROM FRAME 28-30. REMOVED AND REPLACED #1 FLOOR SILL FROM FRAME 28-30.SDR JJBA20251024063Plate · crackedRH AILERON DAMPER MOUNT PLATE CRACKED. FULLY REMOVED RH AILERON ASSY AND INSTALLED NEW AILERON.SDR JJBA20251120105Stringer Splice · corrodedPROFILE SPLICE FOUND WITH CORROSION IN BATHROOM UNDER FLOOR AREA LOCATION FR 60-61 (STA X=20793.0) STGR 17L. REMOVED AND REPLACED STGR SPLICE 17L BETWEEN FR 60-61SDR JJBA20251024059Door Frame · corrodedCORROSION AT RT SERVICE DOOR ENTRANCE FRM 20-22 RBL 19. REMOVED AND REPLACED RT SERVICE DOOR ENTRANCE FROM 20-22 RBL 19.SDR JJBA20251024058Bracket · corrodedPAX DOOR FLOOR PANEL BRACKETS ARE CORRODED. REMOVED CORROSION FROM PAX DOOR FLOOR PANEL BRACKETS. REMOVED AND REPLACED BRACKETSSDR JJBA20251024057Rib · crackedRH WHEEL WELL RIB CRACKED IN MULTIPLE SPOTS. REMOVED AND REPLACED RH WHEEL WELL RIB.SDR JJBA20251024055Rib · crackedLH WHEEL WELL RIB CRACKED IN MULTIPLE SPOTS. REMOVED AND REPLACED LH WHEEL WELL RIB.SDR JJBA20251112035Sill Drain · corrodedCORROSION ON MOP SILL FRAMES 42-49 STR 16R. REMOVED CORRODED MOP SILL AND INSTALLATION OF NEW MOP SILL LOCATED AT FR 42-49 STGR 16LSDR JJBA20251112037Seal · damagedSEAL DAMAGE TO THE LH UPPER AILERON SHROUD. REMOVED AND REPLACED SEAL ON THE LH UPPER AILERON SHROUD .SDR JJBA20251112031Gusset · corrodedRH AFT SERVICE DOOR SIDEWALL GUSSET AT FR 23, STR 6R HAS CORROSION. INSTALLED NEW RH SERVICE DOOR AFT SIDEWALL GUSSET AT FR 23 STR 6RSDR JJBA20251013043Lamp · inoperativeMAIN CABIN DOOR EMERGENCY LIGHT OUT. REMOVED AND REPLACED MAIN CABIN DOOR EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20251112025Floorbeam · corrodedCORROSION ON FLOOR BEAM FRAME 37 TO 38 STR 16L. REMOVED AND REPLACED OF FLOOR SILL BETWEEN FRAMES 35-39, STRINGER 16LSDR JJBA20251112036Sill Drain · corrodedLEFT MOP SILL AT FR 35 TO FR 34, STR 6L HAS CORROSION. LT MOP SILL AT FR34 TO FR33, STR 6L HAS CORROSION. LT MOP SILL AT FR 31, STR 6L HAS CORROSION. INSTALLED NEW MOP SILL AT FR30-FR35 STR 16LSDR JJBA20251112033Floor Support · corrodedRH FLOOR GUSSET AT FR 35, STR 4R IS BENT WITH DAMAGED FASTENER HEADS. REMOVED RH FLOOR GUSSET AT FR35, STR 4R DOUBLER AND REPLACED.SDR JJBA20251112024Frame · corrodedCORROSION FRAME 18 STR 18R. REMOVED AND REPLACED DOUBLER AT FRAME 18 STR 18R.SDR JJBA20251110017Floorbeam · corrodedSURFACE CORROSION LOCATION: FLOOR BEAM, CENTER ISLE, UNDER PANEL 231FF. INSTALLED NEW FLOOR BEAM, CENTER AISLE, UNDER PANEL 231FFSDR JJBA20251008027Channel · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR33. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR33SDR JJBA20251112032Sill Drain · corrodedRH MOP SILL, FWD SECTION, AT FR 24 STR 6R HAS CORROSION. INSTALLED NEW MOP SILL, FWD SECTION AT FR 24, FR 25, AND FR 26 STR 6R.SDR JJBA20251112026Floorbeam · corrodedCORROSION ON FLOOR BEAMS FRAME 44-45 AT STR 16L. REMOVED MOP SILL FROM FR 42 TO FR 48 AND REPLACED WITH NEW.SDR JJBA20251112023Frame · corrodedCORROSION FRAME 15 STR 21R. REMOVED CORROSION AND INSTALLED DOUBLER REPAIRSDR JJBA20251110022Frame · corrodedCORROSION FRAME 20 STR 18. INSTALLED NEW DOUBLER AT FRAME 20 STR 18SDR JJBA20251110020Floorbeam · corrodedLH FLOOR BEAM AT FR61 STR 4L HAS CORROSION. INSTALLED NEW FROM STOCK LH FLOOR BEAM GUSSET PLATE AT FR 61.SDR JJBA20251112040Strap · crackedCRACK ALONG FASTENER HOLE IN PANEL 195EL UPPER RETAINING STRAP AT FRAME 41. REMOVED AND REPLACED PANEL 195EL UPPER RETAINING STRAP AT FRAME 41.SDR JJBA20251112034Sill Drain · corrodedCORROSION ON THE MOP SILL FRAME 29 AT STR 16. REMOVED AND INSTALLED NEW RH FLOOR SILL AT FR 35-39SDR JJBA20251112030Floor Support · corrodedLH OMEGA BEAM HAS MULTIPLE AREAS OF CORROSION. PERFORMED BLEND OUT PROCEDURE ON 3 LOCATIONS ON THE LH OMEGA BEAM BETWEEN FR 58 TO FR 61SDR JJBA20251010041Skin · crackedLH THRUST REVERSER EXTERNAL SKIN OUTBD SIDE IS CRACKED NEAR THE UPPER DOOR. LH THRUST REVERSER EXTERNAL SKIN OUTBD SIDE UPPER DOOR PAINT REMOVED FOR INSPECTION. LH THRUST REVERSER EXTERNAL SKIN OUTBD SIDE NEAR THE UPPER DOOR SKIN REPAIRED.SDR JJBA20251006015Engine · no discrepancyPOSSIBLE BIRD INGESTION, #2 ENGINE. PERFORMED BORESCOPE OF LAST STAGE COMPRESSORS FROM BOTTOM IGNITER PLUG. NO DEFECTS NOTED. PERFORMED BORESCOPE INSPECTION OF FORWARD AREA THE COMPRESSOR INLET GUIDE VANES. NO DEFECTS FOUND AT THIS TIME. PERFORMED DVI FOR FOD SDR JJBA20251112041Strap · crackedCRACK ALONGSIDE FASTENER HOLE IN PANEL 194ER UPPER RETAINING STRAP AT FRAME 48. REMOVED DAMAGED STRAP AND INSTALLED NEW UPPER RETAINING STRAP FOR PANEL 194ER AT FRAME 48.SDR JJBA20251112028Floorbeam · corrodedMID FLOOR BEAM AT FR 61, STR 1R HAS CORROSION. REMOVED DAMAGED GUSSET AND INSTALLED NEW MID FLOOR BEAM GUSSET PLATE AT FR61SDR JJBA20251112027Floorbeam · corrodedRH FLOOR BEAM AT FR 61, STR 4R HAS CORROSION. REMOVED AND REPLACED GUSSET PLATE AT FR 61 STR 4RSDR JJBA20251110021Gusset · corrodedCORROSION AT FRAME 20 STR 21R. REMOVED AND REPLACED GUSSET AT FR 18 TO FR 24SDR JJBA20251110019Floor Support · wornBARE METAL. LOCATION: CABIN UNDER FLOOR PANEL 231HF. REMOVED AND REPLACED FLOOR SILL AT FR 24.SDR JJBA20251008016Flap System · faultedFLAP FAIL AT 9 DEGREES. ON DESCENT, FLAPS MOVED TO 9 DEGREES, GREEN FLAP LIGHT INDICATED, THEN FLAP FAIL MESSAGE. R & R FLAP RESET SWITCH. OPS CHKD SAT. NO FAIL MESSAGE. INSPECTED MECHANICAL LINES SHROUD, ROLLERS & CONNECTORS. SECURED CONNECTORS P3683 & P368SDR JJBA20251006017Windshield · crackedCAPT WINDSHIELD CRACKED. REMOVED AND REPLACED CAPT WINDSHIELD. OPS CHECK SAT.SDR JJBA20251010039Skin · corrodedRFI EXT, SKIN UNDER ANTENNA BTW FR 70-68 AND STR 21R-21L FOUND CORRODED. REPAIR DOUBLER ON RFI LOWER SKIN, BTW FR 68-69 AND BTW 21L-21RSDR JJBA20251008022Plate · corrodedRFI, FWD RADIO ALTEMETER ANTENNA DOUBLER BTW FR 65-66 AND STR 21R-21L FOUND CORRODED. RF1, ANTENNA DOUBLER BTW FR 65-66 AND STR 21L-21R BLENDED AND FOUND OUT OF LIMIT. RF1, FWD RADIO ALTIMETER ANTENNA DOUBLER BTW FR 65-66 AND STR 21R-21L REPLACED.SDR JJBA20251008035Skin · crackedAT REAR FUSE, CRACK FOUND ON LH TOP SKIN AT FR 75 BTW STR 2L-3L. REPAIR DOUBLER ON LH REAR FUSE I UPPER SKIN, AT FR 75 AND AT STR 2LSDR JJBA20251008018Door Sill · corrodedSERVICE DOOR FWD SILL BTW FR 18-20 FOUND CORRODED. AT CFI, SERVICE DOOR FWD SILL BTW FR 18-20 SILL CORRODED OUT OF LIMIT. CFI, SERVICE DOOR FWD SILL BTW FR 18-20 REPLACED.SDR JJBA20251110018Floorbeam · corrodedSURFACE CORROSION LOCATION: FLOOR BEAM, UNDER PANEL 231HF ZONE 140-142. REMOVED DAMAGED LH FLOOR SILL FROM FR 19-23 AND INSTALLED NEW FLOOR SILL.SDR JJBA20251008038Floor Support · corrodedRH OMEGA BEAM #1 FOUND CORRODED BTW FR 18-19. AT RH OMEGA BEAM #1 BTW FR 18-20 OMEGA BEAM CORRODED OUT OF LIMIT. RH OMEGA BEAM #1 BTW FR 18-20 REPAIRED.SDR JJBA20251008034Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR 26. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR26SDR JJBA20251008033Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR31. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR31SDR JJBA20251008032Floor Support · crackedCFI, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR21. REPAIR DOUBLER ON CFI, LH OMEGA BEAM, ON INBD VERICAL FLANGE AT FR 21.SDR JJBA20251008031Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR34. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR34SDR JJBA20251008029Floor Support · crackedLH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR25. REPAIR DOUBLER ON CFII, LT OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR 25SDR JJBA20251008026Floor Support · crackedCFI, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR22. REPAIR DOUBLER ON CFI, LH OMEGA BEAM, ON INBD VERICAL FLANGE AT FR 22SDR JJBA20251008023Shear Tie · corrodedRF1, CARGO ENTRANCE L-FRAME 68 BTW STR 17L-18L FOUND CORRODED. RF1, CARGO ENTRANCE L-FRAME 68 BTW STR 17L-18L BLENDED. RF1 CARGO ENTRANCE L-FRAME 68 BTW STR 15L-16L CUTOUT WAS DONE. RF1 CARGO ENTRANCE L-FRAME 68 BTW STR 17L-18L REPAIRED.SDR JJBA20251002001Battery · dislodgedLEFT EXTERNAL FWD EMERGENCY LIGHT INOPERATIVE. FOUND EMERGENCY BATTERY 1 HAS FALLEN OFF OF ASSEMBLY. REINSTALLED THAT EMERGENCY BATTERY. OPS CHECK SAT.SDR JJBA20251008037Frame · crackedCF2, BTW STR 15R-16R, RH FRAME 25 FOUND CRACKED. FRAME REPAIRED. U CHANNEL AND REPAIR SPLICE FABRICATED WITH AN ALTERNATE MATERIAL.
Back to Embraer EMB-145XR