Embraer EMB-145XR
Service difficulty reports · 9,191
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20250711017Door Frame · corrodedCARGO DOOR CORRODED AT FWD LOWER CORNER FRAME 65. REMOVED CORROSION CARGO DOOR AT FWD LOWER CORNER FRAME 65. REMOVED CARGO DOOR FWD LOWER CORNER AT FRAME 65 RECEIVED NEW PART. LOCATED, DRILLED AND INSTALLED NEW PARTSDR JJBA20250711016Door Frame · corrodedLOWER CARGO DOOR FRAME CORROSION AROUND NUTPLATE HOLES AT FRAME 66. REMOVED CORROSION LOWER CARGO DOOR FRAME AROUND NUTPLATE HOLES AT FRAME 66 OUT OF LIMITS. REMOVED AND INSTALLED NEW PARTS. LOCATED, DRILLED, AND INSTALLED.SDR JJBA20250630025Gusset · corrodedLH GUSSET 4 BTW FR 35-39 FOUND CORRODED. LH GUSSET 4 BTW FR 35-39 BLENDED AND FOUND WITHOUT LIMIT. LH GUSSET 4 BTW FR 35-39 REMOVED AND REPLACED. LH PASSENGER SEAT TRACK BTW FR 35-39 OVER GUSSET WERE REMOVED AND INSTALLEDSDR JJBA20250627022Battery Pack · inoperativeEMERGENCY LIGHTS AT ROW 18 ARE DIM. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY #3. OPS CHECK SAT.SDR JJBA20250627021Light · misinstalledRH OVERWING EXTERNAL EMERGENCY LIGHT INSTALLED UPSIDE DOWN. INSTALLED RH OVERWING EXTERNAL EMERGENCY LIGHT CORRECTLY.SDR JJBA20250627020Charger · inoperativeAISLE AFT EMERGENCY CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT HOUSING. OPS CHECK FAILED. REMOVED AND REPLACED #4 EMERGENCY LIGHT BATTERY CHARGER ASSEMBLY. OPS CHECK SAT.SDR JJBA20250627019Battery Pack · no testMULTIPLE EXTERIOR AND INTERIOR EMERGENCY LIGHT INOPERATIVE. SUSPECT BAD BATTERY. REMOVED AND REPLACED EMERGENCY BATTERY 3. OPS CHECK SAT.SDR JJBA20250711012Bracket · corrodedL BRACKET AT BL 0 FRAME 18 UNDER MIDDLE FLOOR SUPPORT HAS CORROSION AND GOUGE. REMOVED AND REPLACED L BRACKETSDR JJBA20250711010Support · corrodedRH SILL BTW FR53-59 CORRODED. BTW FR 53-59 RH SILL BLENDED OUT OF LIMITS. RH SILL BTW FR 53-59 REMOVED AND REPLACED.SDR JJBA20250623017Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250730119Channel · corrodedCF1, CHANNEL BTW FR20-22 AT SERVICE DOOR LOCATION FOUND CORRODED. CF1, CHANNEL BTW FR 20-22 AT SERVICE DOOR BLENDED OUT OF LIMIT. REPAIR PART FABRICATED. AT CF1, CHANNEL BTW FR 20-22 AT SERVICE DOOR, REPAIR PART INSTALLED.SDR JJBA20250728104Shear Tie · crackedSHEAR CLIP AT FR60 BTW STR 19R-20R FOUND CORRODED. SHEAR CLIP AT FR60 BTW STR 19R-20R BLENDED OUT OF LIMITS. SHEAR CLIP AT FR 50 BTW STR 19R-20R REMOVED AND INSTALLEDSDR JJBA20250716053Shear Tie · corrodedCF1, SHEAR CLIP AT FR15 BTW STR 15R-16R FOUND CRACKED. CF1, SHEAR CLIP AT FR15 BTW STR 15R-16R REMOVED AND REPLACEDSDR JJBA20250716052Shear Tie · corrodedSHEAR CLIP AT FR61 BTW STR 19R-20R FOUND CORRODED. SHEAR CLIP AT FR61 BTW STR 19R-20R BLENDED OUT OF LIMITS. SHEAR CLIP AT FR61 BTW STR 19R-20R DRILLED NEW HOLES IN NEW SHEAR CLIP. INSTALLED NEW SHEAR CLIP AT FR61.SDR JJBA20250711038Angle · crackedCF1, ANGLE ON INBD SIDE OF LH OMEGA BEAM BTW FR 19-20 FOUND CRACKED. CF1 ANGLE ON INBD SIDE ON LH OMEGA BEAM BTW FR 19-20 REMOVED AND REPLACEDSDR JJBA20250623018Handle · lack of lubeMAIN CABIN DOOR HARD TO CLOSE AND LOCK. FOUND MCD HARD TO LOCK FROM INSIDE. LUBRICATED INTERNAL ACTUATING HANDLE WITH LPS. ACTUATED MCD SEVERAL TIMES. OC SAT.SDR JJBA20250721068Floor Support · corrodedCF1, CENTER OMEGA BEAM GUSSET BTW FR 18-23 FOUND CORRODED. AT CF1 CENTER OMEGA BEAM GUSSET BTW FR 18-23 BLENDED OUT OF LIMIT. AT CF1 CENTER OMEGA BEAM GUSSET BTW FR 18-23 REMOVED AND REPLACEDSDR JJBA20250711027Floorbeam · corrodedRH IB FLOOR SUPPORT CAP AT FRAME 39 IS BENT AND RIVETS ARE PUNCHED THROUGH. REMOVED RH IB FLOOR SUPPORT CAP AT FRAME 39. RECEIVED NEW DOUBLER, LOCATED, DRILLED AND INSTALLED NEW PART.SDR JJBA20250711009Floor Support · corrodedCF1, ANGLE ON INBD SIDE OF CENTER OMEGA BEAM BTW FR18-20 FOUND CORRODED. AT CF1 ANGLE ON INBD SIDE OF CENTER OMEGA BEAM BTW FR18-20, ANGLE REMOVED. AT CF1 ANGLE ON INBD SIDE OF CENTER OMEGA BEAM BTW FR 18-20 FOUND CORRODED OUT OF LIMIT. DRILLED NEW HOLES FOR NSDR JJBA20250723087Fairing · corrodedCORROSION FOUND AROUND LH, RH EXTERNAL EMERGENCY LIGHTS ON FWD BODY FAIRING. FWD BODY FAIRING LIGHTS FROM FAIRING PLATE REMOVED, CORROSION REMOVED OUT OF LIMITS. FWD BODY FAIRING PLATE NEW DRILLED. FWD BODY FAIRING PLATE AND LIGHT EMERGENCY INSTALLED.SDR JJBA20250623016Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECK FAILED. SUSPECT BAD HOUSING. REMOVED AND REPLACED LIGHT ASSEMBLY HOUSING. OPS CHECK SAT.SDR JJBA20250623015Sign · inoperativeEXIT LOCATING SIGN MID CEILING FWD INOPERATIVE. REMOVED AND REPLACED EXIT LOCATING SIGN FWD SIDE MID CEILING. OPS CHECK SAT.SDR JJBA20250617014Lamp · inoperativeRH EXTERNAL EMERGENCY LIGHT ABOVE RH PACK PANEL INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK GOOD.SDR JJBA20250616013Screen · faultedBURNING SMELL, LIKE FIREWORKS, DURING CRUISE AND INTO DESCENT. PERFORMED FIM. FOUND PACK 2 EXHAUST GRATE AND DUCT TO BE AT FAULT. REMOVED AND REPLACED PACK 2 EXHAUST GRATE AND DUCT. OPS CHECK GOOD AT THIS TIME. NO FURTHER DEFECTS NOTED. NO BURNING SMELL NOTED.SDR JJBA20250613012Lamp · inoperativeINTERIOR EMERGENCY LIGHS ABOVE SEATS 18A AND 18CD INOPERATIVE. REMOVED AND REPLACED BOTH BULBS. OPS CHECK SAT.SDR JJBA20250611011Unknown · odorFOUL AIR SMELL COMING FROM AIR CONDITIONING IN CABIN AND FLIGHT DECK THROUGHOUT THE FLIGHT (OILY SMELL). INSPECTED E1, E2 AND APU FOR OIL LEAKS. NO OIL LEAKS NOTED. FOUND DEBRIS IN GROUND AIR INTAKE DUCT. CLEANED AND RAN BOTH PACKS. NO SMELL NOTED AT THIS TIMESDR JJBA20250611010Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250611007Door · out of adjustMCD GETTING STUCK WHEN OPENING FROM INSIDE. PERFORMED OPS CHECK OF MAIN DOOR TO FUSELAGE SKIN ADJUSTMENT. FOLDING FLAP EDGE AND MAIN DOOR EXTERNAL HANDLE WONT CLOSE ALL THE WAY. PERFORMED RODS ADJUSTMENT. REMOVED AND REPLACED REAR LOCK BOX CABLE. REMOVED AND SDR JJBA20250611009Charger · inoperativeLH AND RH EXTERNAL OVERWING EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED BPS #4. OPS CHECK FAILED. RETURNED TO ORIGINAL CONFIGURATION. REMOVED AND REPLACED BPS #4 CHARGING ASSEMBLY. OPS CHECK GOOD.SDR JJBA20250609008Panel · out of positionMCD WONT CLOSE, TOP PANEL HAS GAP AND EXTERNAL HANDLE NOT FLUSH. PERFORMED MCD ADJUSTMENT/TEST AND PERFORMED CHECK WITH THE FORCE GAUGE. LOAD IS WITHIN LIMITS, FOUND RH UPPER ROLLER CAM TO BE LOOSE. RESECURED CAM. SERVICED/LUBRICATED MCD. MCD CYCLE OPEN/CLOSE.SDR JJBA20250609006Door · stuckMCD STUCK CLOSED. FREED MCD AND PERFORMED OPS CHECK. MCD CLOSED AND OPENED NORMALLY. NO FURTHER DEFECTS NOTED.SDR JJBA20250609005Door Sill · corrodedCORROSION FOUND ON AFT SERVICE DOOR THRESHOLD AT FRAME 22. REPAIRED SERVICE DOOR AFT SILL. COMPLETED EDDY CURRENT HIGH FREQUENCY INSPECTION OF AFT SERVICE DOOR SILL REPAIR. NO INDICATIONS OF CRACKS AT THIS TIME.SDR JJBA20250711022Floor Support · corrodedLH OB FLOORSILL FROM FRAME 41 TO 48 IS CORRODED. REMOVED CORROSION LH OB FLOORSILL FROM FRAME 41 TO 48. LOCATED, DRILLED AND INSTALLED NEW PARTSDR JJBA20250711021Floorbeam · corrodedAT FRAME 20 MIDDLE FLOOR SUPPORT CAP CORRODED. REMOVED CORROSION AT FRAME 20 MIDDLE FLOOR SUPPORT CAP. LOCATED, DRILLED AND INSTALLED NEW PARTSDR JJBA20250602004Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250602003Lamp · inoperativeCENTER AISLE CEILING EMERGENCY LIGHT AT ROW 18 INOPERATIVE. REMOVED AND REPLACED ROW 18 CENTER AISLE CEILING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250602097Battery · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT LAMP. OPS CHECK FAILED. INSTALLED NEW EMERGENCY LIGHT BATT 1 AND 2. OPS CHECK FAILED. AIRCRAFT RETURNED TO ORIGINAL CONFIGURATION. FOUND CONTACTOR STUCK, CLEANED CONTACSDR JJBA20250602096Battery · inoperativeCABIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT LAMP. OPS CHECK FAILED. REMOVED AND REPLACED EMERGENCY LIGHT BATT 1 AND 2. OPS CHECK FAILED. AIRCRAFT RETURNED TO ORIGINAL CONFIGURATION. FOUND CONTACTOR STUCK CLEANED CONTACTOR. SDR JJBA20250602095Light · misinstalledRH OVERWING EXTERNAL EMERGENCY LIGHT INSTALLED UPSIDE DOWN. REMOVED AND REINSTALLED RH OVERWING EXTERNAL EMERGENCY LIGHT IN CORRECT POSITION.SDR JJBA20250529093Switch · out of positionENG 1 FUEL INDICATION SHOWING 0 POUNDS AT CRUISE ALT. FOUND POWER SELECTION TO BE IN BATTERY POSITION AND REFUELING SWITCH TO BE IN OPEN POSITION ON REFUELING PANEL. RESET SWITCHES TO NORMAL CONFIGURATION. OPS CHECK GOOD. COMPLIED WITH ENGINE RUNS AT ALL POWERSDR JJBA20250529092Trim Panel · unsecureSERVICE DOOR HARD TO OPEN OR CLOSE. FOUND DOOR TO BE BINDING ON TRIM. RESECURED TRIM. OPS CHECK GOOD.SDR JJBA20250602094Skin · damagedDAMAGE TO RIGHT SIDE OF NOSE AT FRAME 7, BETWEEN STRINGER 6R AND 9R. FOUND DENT LOCATED AT FRAME 7 BETWEEN STRINGER 6R AND 9R. FOUND SKIN CREASES BETWEEN FRAME 6 AND 7 AND STRINGERS 6R AND 9R. NO INTERNAL DAMAGE IS NOTED. NO RIVETS FOUND POPPED. CUT OUT FILLERSDR JJBA20250602089Bracket · corrodedCORROSION FOUND AROUND LOWER BRACKET ON VENTRAL FUEL TANK FACE CENTER. REMOVED AND REPLACED VENTRAL TANK. OPS AND LEAK CHECK SAT.SDR JJBA20250523091Battery Pack · inoperativeSERVICE DOOR UPPER AND LOWER EMERGENCY EXIT LIGHTS INOPERATIVE. SUSPECT BAD EMERGENCY LIGHT BATTERY. REMOVED AND REPLACED #2 EMERGENCY LIGHT BATTERY. OPS CHECK SAT.SDR JJBA20250523090Light · inoperativeRIGHT EXTERIOR FWD EMERGENCY EXIT LIGHT INOPERATIVE AND HOUSING DAMAGED. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD.SDR JJBA20250613002Support · corrodedFOUND LEVEL 2, MODERATE CORROSION ON LH ELEVATOR RVDT SUPPORT ASSEMBLY STRUCTURAL MOUNT. FOUND LIGHT SURFACE CORROSION AND CLEANED. INSTALLED LH ELEVATOR RVDT SUPPORT. OPS CHECK SAT. NO DEFECTS NOTED AT THIS TIME.SDR JJBA20250613001Floor Panel · delaminatedLAV FLOOR PANEL DELAMINATED AND LAV BI-FOLD DOOR TRACK INSERTS DETACHED FROM THE FLOOR PANEL. REMOVED LAV BI-FOLD DOOR. REMOVED LAV DOORSILL. REMOVED LAV. INSTALLED LAV. OPS CHECK SAT. INTALED NEW LAV FLOOR PANEL.SDR JJBA20250520082Charger · inoperativeMCD FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK FAIL. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECK FAILED. REMOVED AND REPLACED LIGHT BATTERY CHARGER. OPS CHECK SAT.SDR JJBA20250520087Shear Tie · damagedL-SHAPE FRAME 65, DAMAGE FROM IMPACT. SPLICE REPAIR ON LH REAR FUSE I FRAME 65 SHEAR CLIP BTW STR 14L-15LSDR JJBA20250520086Frame · corrodedLH FR 65 BTW STR 14-15 FOUND CORRODED. CORROSION LEVEL 1. SPLICE AND FRAME SECTION FABRICATED. SPLICE REPAIRED ON LH REAR FUSE I FRAME 65 BTW STR 14L-15L
Back to Embraer EMB-145XR