SDR JJBA20260518014Seal · fodMCD DIFFICULT TO CLOSE. PERFORMED INSPECTION OF MCD RUBBER SEAL. REMOVED DEBRIS FROM SEAL. DOOR CLOSES NORMALLY. PERFORMED PRESSURIZATION CHECK. OPS CHECK SAT. NO ABNORMAL NOISE/SOUND NOTED.SDR JJBA20260518011Oil System · overservicedFUMES SMELLED ON TO ON OCF FROM SURFACE TO 2000 FT SIMILAR TO GASOLINE NOT JET A. INSPECTED E1/E2 INLETS. T/S USING FIM. FOUND BURNT OIL ODOR WOULD OCCUR WHEN RUNNING PACKS OFF OF APU. INSPECTED APU FOR SIGNS OF OVERSERVICING. FOUND APU OIL OVER SERVICED ABOVSDR JJBA20260518010Fuse · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BPS2 INOP. R&R F2 FUSE ON BPS2 CHARGER. OP CHECK GOODSDR JJBA20260518009Lamp · inoperativeMCD EMERGENCY LIGHT INOP. R/R MCD EMERGENCY LAMP. OPS CHK SATSDR JJBA20260518016Handle · misinstalled18D EXIT ROW DOOR HANDLE UPSIDE DOWN. REINSTALLED 18D EXIT ROW DOOR HANDLE TO ORIGINAL CONFIG. OPS CHECK SAT. NO DEFECTS NOTED.SDR JJBA20260518008Unknown · odorFUMES IN COCKPIT AND CABIN ON LIFT OFF. T/S, PERFORMED ENGINES RUNS. PERFORMED PACKS OPERATION. NO ABNORMAL SMELLS OBSERVED, NO DEFECTS NOTED. FURTHER T/S INSPECTED W/S TEMP CONTROL. FOUND NO DEFECTS. INSEPCTED W/S TERM. NO DEFECTS. INSPECTED COMP. WASH PORT CSDR JJBA20260520021Shear Panel · gougedAPU INTERIOR GOUGE ON SHEAR PANEL. BLEND OUT WAS PERFORMED.SDR JJBA20260520020Frame · bentAPU INTERIOR, FRAME SHAPE U FWD-TO-REAR MULTIPLES BENT. RECOUNTOUR WAS PERFORMED.SDR JJBA20260520018Skin · nickedNICK ON FUSELAGE SKIN LT NEAR FR 10 BETWEEN STGR 15 - STGR 17. PERMANENT REINFORCEMENT REPAIR WAS PERFORMED.SDR JJBA20260520017Skin · gougedLH FWD FUSELAGE SKIN GOUGE / NICK BETWEEN FRM 10-11 STGR 15-17. PERMANENT REINFORCEMENT REPAIR WAS PERFORMED.SDR JJBA20260512007Handle · lack of lubeMAIN CABIN DOOR WILL NOT OPEN OR CLOSE PROPERLY. INSPECTED AND LUBED MCD HANDLE. OPS CHECK SAT.SDR JJBA20260520023Skin · damagedCREASE ON LH FWD FUSELAGE BETWEEN STGRS 15-16 AND FRAMES 11-12 CLOSE TO FRAME 12. RECOUNTOUR WAS PERFORMED.SDR JJBA20260520022Skin · canningLH APU SKIN OIL CANNING AND DENT. PERMANENT REINFORCEMENT REPAIR WAS PERFORMED.SDR JJBA20260520019Inlet · gougedAPU INLET INTERIOR GOUGE/DENT ON LOWER SKIN. DOUBLER REPAIR WAS PERFORMEDSDR JJBA20260512006Lamp · inoperative18A OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED 18A OVERWING EMERGENCY LAMP. OPS CHECK SAT.SDR JJBA20260508005Lamp · inoperativeMOST AFT AISLE EMERGENCY LIGHT ON CEILING PANEL IS INOPERATIVE. REMOVED AND REPLACED MOST AFT EMERGENCY AISLE LIGHT LAMP AND LIGHT HOUSING ASSEMBLY. OPS CHECK SATSDR JJBA20260508004Terminal Block · meltedWOOD BURNING SMELL IN COCKPIT, NEAR GLARE SHIELD FO SIDE. FOUND RH W/S SENSORS TO SHOW EVIDENCE OF ELECTRICAL DAMAGE SUCH AS MELTING SENSORS, TERMINAL BLOCK MELTING, AND SOLDER DAMAGE TO TERMINALS P AND G. REMOVED FO'S WINDSHIELD AND ALSO WIPER AND REPLACED 4SDR JJBA20260508003Battery · dischargedEMERGENCY LIGHTS INOPERATIVE. CHARGED EMERGENCY LIGHT BATTERIES AND PERFORMED EMERGENCY LIGHTING. OPS CHECK SAT.SDR JJBA20260505002Battery · inoperativeBOTH LT AND RT LATERAL WTF FAIRING EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED NR 4 EMERGENCY LIGHT BATTERY, INTERIOR LT OVERHEAD EMERGENCY EXIT LIGHT NOW FUNCTIONING. REMOVED AND REPLACED NR 4 EMERGENCY LIGHT BATTERY CHARGER. NOW RT EXTERIOR OSDR JJBA20260505001Light · inoperativeOVERHEAD EXIT ROW EMERGENCY LIGHT INOPERATIVE (FWD). REMOVED AND REPLACED FWD OVERHEAD EXIT ROW EMERGENCY LIGHT.SDR JJBA20260501033Battery Pack · inoperativeEXTERIOR EMERGENCY LIGHT - WING FUSELAGE FRONT FAIRING LT - INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY #1. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA20260501032Light Sys · faulted18CD LOWER EXIT MARKER ON ESCAPE HATCH INOPERATIVE. PERFORMED ELECTRICAL RESET AND PERFORMED EMERGENCY LIGHT OPS CHECK. OPS CHECK GOOD.SDR JJBA20260501031Lamp · inoperativeLH EXTERNAL WING/FUSELAGE FAIRING FWD EMERGENCY LIGHT INOPERATIVE. REPLACED LH EXTERNAL WING/FUSELAGE FAIRING FWD EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20260501030Lamp · inoperativeLH EXT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB ON LH EXT OVERWING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20260427029Handle · misinstalledMCD HARD TO OPEN AND CLOSE. FOUND INBOARD DOOR HANDLE INSTALLED INCORRECTLY. RE-INSTALLED INBOARD DOOR HANDLE. OPS CHECK SATSDR JJBA20260427027Lamp · inoperativeROW 3 CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED ROW 3 CEILING EMERGENCY LIGHT. OPS CHECK SATSDR JJBA20260427028Battery Pack · inoperativeSEVERAL EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BPS #3. OPS CHECK GOOD.SDR JJBA20260423017Battery Pack · misinstalledSEVERAL EMERGENCY LIGHTS INOPERATIVE. FOUND #3 BPS NOT INSTALLED CORRECTLY. REINSTALLED. OPS CHECK GOOD.SDR JJBA20260423016Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT LAMP. OPS CHECK FAILED. FOUND 2 BROKEN WIRES LEADING TO LIGHT ASSEMBLY. REPAIRED WIRES. OPS CHECK GOOD.SDR JJBA20260423025Skin · canningAPU SKIN OIL CANNING UPPER BETWEEN PROFILES, SIDE LH. REPAIRED APU COWLING SKIN.SDR JJBA20260423022Thrust Reverser · damagedSKIN DAMAGE LOWER INBOARD REVERSER LH. A REINFORCEMENT WAS INSTALLED. THE REPAIR WAS COMPLETED WITH NO ISSUED.SDR JJBA20260423024Skin · chafedAPU COWLING SHEAR PANEL HAS SEVERAL CHAFING ON SKIN. PERMANENT REPAIR WAS PERFORMED.SDR JJBA20260423023Skin · damagedAPU COWLING INTERNAL SKIN GOUGE-DENT. PERMANENT REPAIR WAS PERFORMED.SDR JJBA20260417015Sensor · inoperativeFLAP FAIL AT 5 DEGREES IN FLIGHT AT 3000 FT MSL. FOLLOWED FIM. REMOVED AND REPLACED LH FLAP VELOCITY SENSOR. OPS CHECK SAT. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR JJBA20260417014Inverter · inoperativeFWD-MOST CEILING EMERGENCY EXIT LIGHT INOPERATIVE. FOUND COCKPIT STEP EXIT LIGHT ALSO INOPERATIVE. REMOVED AND REPALCED INVERTER #1. OPS CHECK SAT.SDR JJBA20260423020Skin · dentedMAIN DOOR SEVERAL DENT ON UPPER SKIN. DENT ASSESSMENT WAS PERFORMED. DENT 1 - NO ACTION REQUIRED ALLOWABLE DAMAGE. DENT 2 - NO ACTION REQUIRED ALLOWABLE DAMAGE ALSO AFTER INSPECTION, REWORKED AREA WAS FOUND ON LOWER AFT MAIN DOOR. PERMANENT REPAIR WAS PERFORMESDR JJBA20260423018Skin · scratchedSCRATCH BETWEEN FR 22 AND FR 23 AND STGR 13 FUSELAGE RH. SCRATCH ASSESSMENT WAS PERFORMED. NO ALLOWABLE DAMAGE. BLEND OUT AND THICKNESS WAS PERFORMED. NO ALLOWABLE DAMAGE. RESPIRED PERFORMED. NO ADDITIONAL INSPECTION REQUIREDSDR JJBA20260415013Unknown · odorBURNING ODOR DURING ANTI-ICE OPS IN FLT FOLLOWED BY BLEED 1 LEAK. ODOR DIMINISHED LEAVING ICING CONDITIONS. CRISPY SWEET BURNING ODOR. THE ODOR ONLY OCCURRED IN THE FLT DECK, THE FLT ATTENDANT COULD BRIEFLY SMELL IT BUT IN THE FLIGHT CREW EYES WERE WATERING. TSDR JJBA20260415012Roller · out of adjustMCD HARD TO OPEN AND CLOSE. FOLLOWED FIM. FOUND LOWER AND UPPER ROLLERS MISADJUSTED. READJUSTED LOWER AND UPPER ROLLERS. FORCE NEXESSARY TO ACTUATE INTERNAL HANDLE IS WITHIN LIMITS.SDR JJBA20260413011Roller · lack of lubeMCD DIFFICULT TO OPEN OR CLOSE. LUBRICATED MCD ROLLER. OPS CHECK GOOD.SDR JJBA20260423021Gusset · corrodedCORROSION BEYOND LIMITS ON CENTER FUSELAGE IV FLOOR STRUCTURE, LATERAL SILLS BETWEEN FR61-FR33, GUSSET BEAN HAY BETWEEN FR59 AND FR62 BEAM LH. REPLACED THE GUSSET AND SILLS.SDR JJBA20260415009Engine · faultedENGINE 1 SHUTDOWN INFLIGHT DURING CRUISE. REMOVED PMA AND LWR IGNITER FOR BORESCOPE AND INSTALLED. REMOVED PMA AND LWR IGNITER FOR BORESCOPE AND INSTALLED. REMOVED AND REPLACED ENGINE 1. PERFORMED HIGH POWER RUN. OPS/LEAK CHECK SAT. NO DEFECTS NOTED AT THIS TSDR JJBA20260413010Control Unit · inoperativeDURING INITIAL CLIMBOUT, PITCH TRIM BACK UP INOPERATIVE AND PITCH TRIM MAIN INOPERATIVE. REMOVED AND REPLACED HSCU. REMOVED AND REPLACED FO'S YOKE TRIM SWITCH. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED.SDR JJBA20260423019Skin · dentedBAGGAGE DOOR SKIN HAS SEVERAL DENTS. DENTS WERE EVALUATED AND FOUND ALLOWABLE DAMAGE DENTS 2, 3, AND 6. DENTS 1 AND 4 THE DENTS ARE LOCATED IN THE SHADED AREAS AND DAMAGE IS NOT PERMITTED. THE REPAIR WAS PERFORMED.SDR JJBA20260413008Amplifier · malfunctionedCABIN AND CABIN EMERGENCY LIGHT ON ICU WILL NOT EXTINGUISH. RE-RACKED PA AMP. OPS CHECK OKAY AT THIS TIME. NO FAULTS NOTED.SDR JJBA20260409007Lamp · loose18A EMERGENCY EXIT LIGHT INOPERATIVE. FOUND CONNECTION BETWEEN LAMP AND HARNESS LOOSE. RESECURED LAMP. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA20260409006Battery Pack · inoperative#4 BPS NOT HOLDING CHARGE. REMOVED AND REPLACED #4 BPS. OPS CHECK GOOD.SDR JJBA20260409005Battery · inoperativeNR 2 BPS NOT HOLDING CHARGE. REMOVED AND REPLACED NR 2 BPS. OPS CHECK GOOD.SDR JJBA20260406003Wire Harness · damagedMCD EXT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXT EMERGENCY LIGHT LAMP. OPS CHECK FAILED. FOUND DAMAGE TO SP7426 ON THE HARNESS. REMOVED AND REPLACED HARNESS. OPS CHECK SAT.SDR JJBA20260409004Handle · out of adjustMCD DIFFICULT TO OPEN OR CLOSE. READJUSTED MAIN-DOOR INTERNAL ACTUATING HANDLE.
Back to Embraer EMB-145XR