Embraer EMB-145XR
Service difficulty reports · 9,191
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20200117004Charger · inoperativeBOTH OVER WING EMERGENCY LIGHTS INOPERATIVE. R&R #4 EMERGENCY LIGHT BATTERY. OPS CHECK FAILED. R&R BATTERY CHARGER ASSEMBLY. OPS CHECK SAT. ORIGINAL BATTERY STILL INSTALLED.SDR ASOA202001237009Warning Message · false activationTYS- ABORTED TAKE-OFF DUE TO E1 FIRE DETECT FAIL. MX PERFORMED CONTINUITY CHECK OF THE FIRELOOP AND HARNESS IAW WM 26-11-50 AND NO FAULTS FOUND. OPS CHECK OF THE FIRE DETECT SYSTEM WAS PERFORMED WITH NO FAULTS FOUND IAW AMM 26-10-00-700-802-A.SDR JJBA202001176003Charger · shortedBOTH LH AND RH OVER WING EMERGENCY LIGHTS INOPERATIVE. R&R RH OVER WING EMERGENCY LIGHT ASSEMBLY DUE TO SHORTED ASSEMBLY. R&R #4 EMERGENCY BATTERY AND CRADLE. OPS CHECK FAILED. R&R #4 EMERGENCY LIGHT BATTERY. OPS CHECK SAT.SDR ASOA202002193015Skin · corrodedDURING C CHECK INSPECTION FOUND CORROSSION ON FUSELAGE SKIN AT AFT RADIO ALTIMETER AT FRAME 65 STRINGER 21L-21R. MAINTENANCE REPAIRED I/A/W ETD2020-145-001101SDR RAIA2020011109001Bolt · looseAFTER TAKE OFF, GEAR WOULD NOT COME UP. EICAS MESSAGE: LDG AIR/GROUND FAIL. AFTER LANDING, IC 1-2 INOP. FOUND R/H MLG WOW #2 BRACKET BOLT EXCESSIVELY LOOSE. REMOVED SAFETY, TIGHTENED BOLT, AND RESAFTIED. OPS CHECK GOOD ON 2 GEAR SWINGS.SDR JJBA202001109002Warning Message · false activationLG/AIR GROUND FAIL IN AIR, MESSAGE WENT AWAY AFTER QRH WAS PERFORMED (MESSAGE APPEARED IMMEDIATELY WHEN GEAR SELECTED DOWN, WENT AWAY ON ITS OWN AFTER 4-5 MIN). SERVICED NLG. C/W LANDING GEAR SWING. OPS GOOD.SDR ASOA2020030463025Floor Support · corrodedDURING C CHECK INSPECTION FOUND FLOOR BOARD SUPPORT CORRODED FRAME 18-23 STRINGER 15L-16L. MAINTENANCE REPLACED FLOOR BOARD SUPPORTSDR ASOA202002193016Doubler · corrodedDURING C CHECK INSPECTION FOUND CORROSSION AND MISSING RIVET ON AFT RADIO ALTIMETER BASE FRAME 68-69 AND STRINGER 21L-21R. MAINTENANCE PERFROMED REPAIR I/A/W ETD 2020-145-001101SDR ASOA2020020353006Bearing Cap · corrodedDURING C CHECK INSPECTION FOUND RIGHT FORWARD MAIN LANDING GEAR BEARING CAP HAD CORROSION/PITTING. MAINTENANCE REPLACED THE RIGHT FORWARD MAIN LANDING GEAR BEARING CAP.SDR JJBA202001064001Muffler · unsecureRETURN TO FIELD DUE TO PAX COMPLAINTS OF EXTREME AMOUNTS OF CONDENSATION AND BANGING NOISES AROUND ROW 9 RIGHT SIDE. R&R PACK MUFFLER. OPS CHECK SAT.SDR ASOA2020021903017Skin Splice · corrodedDURING C CHECK INSPECTION SKIN SPLICE WAS FOUND CORRODED AT FRAME 60-61 STRINGER 20R-21R. MAINTENANCE REPAIRED I/A/W SRM 53-00-02 AND 51-40-02.SDR ASOA2020020633014Gusset · corrodedDURING C CHECK INSPECTION FOUND LAV FLOOR CENTER GUSSET AT FRAME 61 HAS SURFACE CORROSION. MAINTENANCE REPLACED LAV FLOOR CENTER GUSSET.SDR ASOA2020020633013Gusset · corrodedDURING C CHECK INSPECTION FOUND CENTER FUSELAGE IV FLOOR GUSSET HAT BEAM AT FRAME 61 HAD CORROSION. MAINTENANCE REPLACED GUSSET HAT BEAM AT FRAME 61SDR ASOA202002033008Bearing Cap · corrodedDURING C CHECK INSPECTION FOUND LEFT AFT MAIN LANDING GEAR BEARING CAP HAD CROSSION PITTING IN 1 AREA. MAINTENANCE INSPECTED AND REMOVED CORROSION IA/W SRM 57-51-07.SDR ASOA202002033007Bearing Cap · corrodedDURING C CHECK INSPECTION FOUND LEFT FORWARD MAIN LANDING GEAR BEARING CAP HAD 3 AREAS OF CORROSION/PITTING. MAINTENANCE REPLACED LEFT FORWARD MAIN LANDING GEAR BEARING CAP.SDR ASOA202001313005Floor Support · corrodedDURING HEAVY CHECK INSPECTION FOUND CORROSION ON CENTER LAV FLOORBOARD SUPPORT AT FRAME 60-61. MAINTENANCE REPLACED LAV CENTER FLOOR BOARD SUPPORT. (GUSSET)SDR ASOA202001313004Gusset · corrodedDURING HEAVY MAINTENANCE CHECK CORROSSION WAS FOUND ON RIGHT SIDE LAV FLOORBOARD SUPPORT. AT FRAME 60 THRU61. MAINTENANCE REPLACED HAT BEAM GUSSET AT FRAME 60 TO 61.SDR RAIA2020010730001Outflow Valve · dirtyA/C PRESSURIZED NORMALLY ON DEPARTURE. AFTER 10,000 FT, RECEIVED AURAL AND EICAS WARNING FOR CABIN ALTITUDE. CABIN ALT=10,400FT, DELTA P= 1.7 OR LESS AT 14,000. FIRST ACTION-- DEFERRED AUTO PRESSURE CONTROLLER--2ND ACTION---CLEANED ELECTROPNEUMATIC AND PNEUMATSDR ASOA202002263018Channel · corrodedDURING C CHECK INSPECTION FOUND SERVICE DOOR SILL CORRODED@HOLES FOR SCREWS. MAINTENANCE REPLACED THE SERVICE DOOR SILL CHANNEL.SDR JJBA2020013102009Beam · corrodedDURING ZONE 131/132 INSPECTION FOUND CORROSION UNDER SERVICE DOOR THRESHOLD PLATE STRUCTURE AROUND NUT PLATE HOLDERS. REMOVED AND REPLACED FWD SERVICE DOOR LOWER BEAM. CORROSION FOUND TO BE LEVEL 2.SDR ASOA2020030313019Door Frame · corrodedDURING C CHECK INSPECTION CARGO DOOR CUTOUT SILL BEAM CORRODED AT FORWARD CORNER. MAINTENANCE REPLACED THE LOWER FRAME DOOR CARGO DOOR BEAM.SDR ASOA2020030403024Skin · damagedDURING C CHECK INSPECTION RIGHT INBOARD FLAP UPPER SURFACE HAS DAMAGED COMPOSITE AT INBOARD EDGE. MAINTENANCE REPAIRED COMPOSITE DAMAGE AT UPPER SKIN INBOARD EDGE I/A/W SRM 57-52-00.SDR JJBA202001310011Light · damaged253CLC FWD EMERGENCY EXIT LIGHT INCORRECTLY ATTACHED AND CRACKED. REMOVED AND REPLACED EXIT SIGN ON 253CLC.SDR JJBA202001310010Angle · corrodedBAGGAGE DOOR CUT OUT AFT LATERAL L-SHAPE CORRODED AT LOWER END AND THRESHOLD. REPAIRED L-ANGLE SPLICE AT FR68. CORROSION FOUND TO BE LEVEL 2.SDR JJBA2019123128012Hose · leakingHYDRAULIC 2 LOW QUANTITY EICAS MESSAGE IN FLIGHT. FOUND SUCTION HOSE CONNECTED TO NUMBER TWO EDP LEAKING. R&R SUCTION HOSE. OPS CHECK AND LEAK CHECK SAT. NO DEFECTS NOTED.SDR ASOA202002063012Rod · corrodedDURING C CHECK INSPECTION FOUND LEFT APU LOWER MOUNTING ROD END CORRODED.MAINTENANCE REPLACED LEFT LOWER ROD ASSEMBLY.SDR ASOA20200206311Support Rod · corrodedDURING C CHECK INSPECTION FOUND UPPER APU MOUNTING RODENDS CORRODED. MAINTENANCE REPLACED APU UPPER SUPPORT RODS .SDR ASOA2019123055120Control Module · odorCREW REPORTED BURNING SMELL IN GALLEY AREA. INSPECTION DETERMINED SMELL CAME FROM CEILING LIGHTS CONTROL BOX. REMOVED AND REPLACED CEILING LIGHT CONTROL MODULE WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR JJBA201912265011Bulb · inoperativeRH OVER WING EMERGENCY LIGHT INOPERATIVE. R&R RH OVER WING EMERGENCY LIGHT BULB. OPS CHECK SAT.SDR JJBA201912264010Control Module · failedSMOKE COMING FROM FA PANEL. PERFORMED GVI OF COMPONENTS & CONNECTORS AROUND FA PANEL. FOUND CONTROL MODULE UNIT BURNED OUT. R&R CONTROL MODULE UNIT. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA201912264009Relay · failedLANDING GEAR AIR/GROUND SYSTEM FAILURE IN FLIGHT. PERFORMED LANDING GEAR WOW PROXIMITY SWITCHES OPS CHECK. R&R RELAY K0278. NO DEFECTS NOTED AT THIS TIME. PERFORMED GEAR SWINGS. OPS CHECK SAT.SDR ASOA2020304223022Rib · crackedDURING C CHECK INSPECTION THE LEFT WING RIB 21 WAS FOUND CRACKED. MAINTENANCE PERFORMED REPAIR I/A/W SRM 57-20-07.SDR RAIA2019122410001Partition · corrodedFR 61 R/H SIDE PARTITION HAS CORROSION UNDER CARBON FIBER RING....R&R R/H SIDE PARTITION AT FR 61.SDR JJBA201912231008Charger · inoperativeLEFT AND RIGHT HAND AFT OVER WING EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT OVER WING EMERGENCY LIGHTS AND FOUND #4 BATTERY CHARGER ASSEMBLY INOPERATIVE. R&R #4 CHARGER ASSEMBLY. OPS CHECK SAT.SDR ASOA20200203009Doubler · corrodedDURING C CHECK INSPECTION FOUND CENTER FUSELAGE IV DRAIN PLUG DOUBLER HAD CORROSION, FRAME 53-FRAME 54 STRINGER 21 LH TO 21 RH. MAINTENANCE REPLACED DOUBLER I/A/W ETD2020-145-001840SDR RAIA2019122600002Shear Tie · corrodedSHEAR CLIP CORRODED AR FRAME 65 BETWEEN STR 21L & 21R. REMOVED AND REPLACED THE SHEAR CLIP.SDR RAIA2019122600001Shear Tie · corrodedFRAME 61, STRINGER 19R, RBL 20 SHEAR TIE FASTENER CORRODED. R & R THE SHEAR TIE.SDR JJBA20191220007Light · inoperativeLH EXTERIOR OVER WING EMERGENCY LIGHT INOPERATIVE. R&R LH EXTERIOR OVER WING EMERGENCY LIGHT. OPS CHECK SAT.SDR ASOA2020030493023Rib · crackedDURING C CHECK INSPECTION FOUND RIGHT WING RIB 21 CRACKED. MAINTENANCE REPAIRED RIGHT WING RIB 21 I/A/W SRM 57-20-07.SDR RAIA2019122618001Skin · corrodedLOWER SKIN OF FUSELAGE ABOVE VENTRAL FUEL TANK HAS POSSIBLE CORROSION- REMOVED CORROSION FROM BELLY EXTERIOR AT FUSELAGE DRAIN BETWEEN FR53-54, STR 21L & 21R & REMOVED THE DRAIN MOUNTING PLATE. AWAITING ULTASOUND SKIN THICKNESS MEASUREMENT. DAMAGE TO BE ALLOWESDR RAIA2019122480001Plate · corrodedAFT DIGITAL PLATE AT FR 18 IS CORRODED....R&R AFT DIGITAL PLATE AT FR 18.SDR JJBA2019122018006Strut · low pressureLG AIR/GROUND FAIL AND GEAR WOULD NOT RETRACT. FOUND LG NOSE WOW PROX SWITCH ON CMC. FOUND NLG REQUIRED SERVICING. SERVICED NLG. OPS CHECK / GEAR SWINGS REQUIRED. PERFORMED GEAR SWING. OPS CHECK FAILED. R&R NLG WOW SWITCH. FOUND NLG STRUT REQUIRED SERVICE, TOOSDR RAIA2019112980002Skin · corrodedLOWER SKIN OF FUSELAGE ABOVE VENTRAL FUEL TANK HAS POSSIBLE CORROSION- REMOVED CORROSION FROM BELLY EXTERIOR AT FUSELAGE DRAIN BETWEEN FR 53-54, STR 21L & 21R & REMOVED THE DRAIN MOUNTING PLATE, AWAITING ULTRASOUND SKIN THICKNESS MEASUREMENT. DAMAGE TO BE ALLOSDR RAIA2019122570004Shear Tie · crackedSHEAR TIE WAS CRACKED AT FRAME 65, STRINGER 18L. R&R THE SHEAR TIE.SDR RAIA2019122570003Floor Support · corrodedLEFT LAVATORY FLOOR SUPPORT HAD CORROSION AROUND AFT NUT PLATE HOLES. R & R THE FLOOR SUPPORT.SDR RAIA2019122570002Gusset · corrodedRIGHT GUSSET IN LAVATORY HAS CORROSION AROUND NUT PLATE HOLES. R&R RT GUSSET IN LAVSDR RAIA2019122417001Floor Support · corrodedR/H LAV FLOOR SILL HAS CORROSION AROUND AFT NUT PLATE HOLE....R&R R/H LAV FLOOR SILL.SDR RAIA2019122070001Pump · failedHYDRAULIC SYSTEM 2 FAIL. R&R #2 HYDRAULIC PUMP. OPS CHECK GOOD.SDR RAIA2019121760001Unknown · odorELECTRICAL SMELL IN COCKPIT.CREW REPRTS A FAINT ELECTRICAL SMELL AND SMOKE VENTING INTO COCKPIT THROUGH CAPTS FWD WINDSHIELD SEAL ON THE LH SIDE.SMELL AND SMOKE DISSIPATED WITHIN 90 SEC. FA REPORTS THAT SHE COULD ONLY DETECT SMELL AT THE COCKPIT DOOR AND NOT TSDR ASOA2020030453021Skin · gougedDURING C CHECK INSPECTION FOUND GOUGE ON FORWARD FUSELAGE SKIN II BELOW GPU ACCESS DOOR. MAINTENANCE REPAIRED DAMAGED SKIN I/A/W SRM 53-12-01 AND ETD2020-145-002945
Back to Embraer EMB-145XR