Service difficulty report · Warning Message · Emb EMB145XR

Difficulty date
January 16, 2020
Submitted
January 24, 2020
Operation
Air carrier
Make and model
Emb EMB145XR
Aircraft serial
145208
Aircraft time
46,848 hours, 35,940 cycles
Part
Warning Message
Condition
False Activation
Location
Fire Detector
Stage of operation
TO
How discovered
O
Nature of condition
N
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TYS- ABORTED TAKE-OFF DUE TO E1 FIRE DETECT FAIL. MX PERFORMED CONTINUITY CHECK OF THE FIRELOOP AND HARNESS IAW WM 26-11-50 AND NO FAULTS FOUND. OPS CHECK OF THE FIRE DETECT SYSTEM WAS PERFORMED WITH NO FAULTS FOUND IAW AMM 26-10-00-700-802-A.