Embraer ERJ 170-100SU
Service difficulty reports · 2,953
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A20100561Connector · looseCREW REPORTED EMERGENCY LIGHT AT FRONT ENTRY WAY OVER CENTER AISLE WAS INOP. MAINTENANCE RE-SECURED CONNECTOR ABOVE AND FORWARD OF THE LIGHT PER EMB AMM.SDR R61A20100567Unknown · malfunctionedCREW REPORTED L-1 DOOR WAS HARD TO ARM AND DISARM. MAINTENANCE PERFORMED OPS CHECK OF L-1 DOOR PER EMB AMM, AND REPORTED NO FAULTS WERE FOUND.SDR R61A20100558Sign · inoperativeCREW REPORTED THE AFT RAINBOW LIGHTS FOR THE AFT LAV SMOKE LIGHT WERE INOP. MX TROUBLESHOT AND REPORTED THE AFT AREA CALL SIGN WAS AT FAULT, R & R THE AFT F/A CALL, F/A PANEL IAW AMM, AND OPS CHECK GOOD.SDR R61A20100557Drain Mast · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE DRAIN MAST SCREW HOLES ON PANEL 195NL. MAINTENANCE REMOVED AND REPLACED THE DRAIN MAST ON PANEL 195NL IAW EMB 170 AMM 20-10-01.SDR R61A20100566Unknown · malfunctionedCREW REPORTED L-1 AND L-2 DOORS WERE DIFFICULT TO DISARM. MAINTENANCE PERFORMED OPS CHECK OF L-1 AND L-2 DOORS PER EMB AMM AND REPORTED NO FAULTS WERE FOUND.SDR R61A20100555Girt Bar · out of adjustCREW REPORTED R1 DOOR ARMING HANDLE DIFFICULT TO MOVE. MX ADJUSTED GIRT BAR PER EMB AMM, OPS CHECK GOOD.SDR R61A20100554Girt Bar · dirtyCREW REPORTED L2 DOOR DISARM LEVER IS DIFFICULT TO MOVE. MX CLEANED GIRT BAR PER EMB AMM, OPS CHECK GOOD.SDR R61A20100556Girt Bar · lack of lubeCREW REPORTS L2 DOOR STIFF WHEN ARMING, MX LUBED GIRT BAR PER EMB AMM, OPS CHECK GOOD.SDR R61A20100548Cable · out of adjustCREW REPORTED L2 DOOR ARM/DISARM INDICATION FLAG AND HANDLE MOVES DURING FLIGHT. MX ADJUSTED CABLE PER EMB AMM OPS CHECK GOOD.SDR R61A20100546Sensor · faultyCREW RECEIVED SLAT FAIL MESSAGE ON EICAS WHILE ON APPROACH TO MCI. FLAPS AND SLATS WOULD NOT DEPLOY AND WERE SET AT ZERO. CREW DECLARED AN EMERGENCY LANDING AND CFR WAS DISPATCHED. AIRCRAFT LANDED SAFELY WITHOUT INCIDENT AND TAXIED TO GATE UNDER ITS OWN POWSDR R61A20100545Mechanism · lack of lubeCREW REPORTED THE L-2 DOOR WAS DIFFICULT TO CLOSE. MAINTENANCE INSPECTED AND LUBED THE L-2 DOOR CONNECTING ROD MECHANISM PER EMB AMM, OPS CHECK GOOD.SDR R61A20100540Slide · blownCREW REPORTED THE THE L-1 DOOR SLIDE WAS BLOWN. MAINTENANCE REMOVED AND REPLACED SLIDE PER EMB AMM.SDR R61A20100535Bolt · looseL2 DOOR IS DROPPING OUT OF ALIGNMENT WHEN DOOR IS OPENED. MX RE-SECURED BOLT PER EMB AMM, OPS CHECK GOOD.SDR R61A20100536Handle · out of adjustL2 DOOR INDICATOR FOR SLIDE ARMED/NOT ARMED IS NOT FUNCTIONING. MX TIGHTENED TURNBUCKLE AND ADJUSTED HANDLE IAW CMM 52-12-22.SDR UHLA2010111000201Engine · malfunctionedFLIGHT ATTENDANTS REPORTED SMOKE SMELL AROUND ROWS 3-6. DIVERTED TO IND AND DECLARED AN EMERGENCY. MAINTENANCE REPORTED OIL FOUND BYPASSING FROM NR 2 ENGINE A SUMP INTO COMPRESSOR. PERFORMED OIL CONSUMPTION CHECK FOUND TO BE WITHIN LIMITS. DEFERRED BLEED 2SDR R61A20100531Light · inoperativeCREW REPORTED WHEN DOING AFT LAV FIRE TEST, THE RAINBOW LIGHTS WERE INOP. MAINTENANCE PLACED ON MEL 26-14-00-1.SDR R61A20100533ASkin · damagedAIRCRAFT HAS A MAJOR REPAIR BEING ACCOMPLISHED. DAMAGE FOUND ON LEFT SIDE OF ACFT FUSELAGE, FRAME 9, STR 17-18L. MAINTENANCE HAS CONTACTED MANUFACTURER ENGINEERING FOR REPAIR INFORMATION. ENGINEERING HAS ISSUED EDT2010-170/10483 FOR REPAIR ACCOMPLISHMENT. SDR R61A20100532Indicator · malfunctionedCREW REPORTED R-2 DOOR SLIDE ARMED INDICATOR WASN'T SHOWING GREEN. MAINTENANCE WAS DISPATCHED TO THE A/C TO TROUBLESHOOT. MTX TROUBLESHOT PER EMB AMM AND COULDN'T DUPLICATE THE ISSUE, AND REPORTED ALL WAS OPERATING NORMALLY.SDR R61A20100530Fitting · corroded*** WHILE AIRCRAFT WAS IN FOR HEAVY CHECK *** LEVEL 2 CORROSION WAS FOUND ON THE AFT OUTBOARD FLOOR MOUNT IN THE FORWARD GALLEY. MAINTENANCE REMOVED AND INSTALLED SERVICEABLE AFT OUTBOARD FLOOR MOUNT IN THE FORWARD GALLEY IAW EMB 170 AMM 20-10-01 & 25-31-01.SDR R61A20100528Unknown · odorCREW REPORTED BLUE HAZE IN FWD GALLEY AND BURN ODOR AS WELL DURING DESCENT, MAINTENANCE TROUBLESHOT PER EMB AMM AND PEROFMRED OPS CHECKS OF BOTH PACK SYSTEMS, NO FAULTS WERE FOUND, AND WERE UNABLE TO DUPLICATE ANY ODOR/SMELLS. THE A/C WAS THEN RETURNED TO SERSDR R61A20100471Hydraulic System · malfunctionedCREW REPORTED HYD SYS 1 OVERTEMP MSG ON EICAS DURING CLIMB, DECLARED AN EMERGENCY AND RETURNED TO FIELD. MAINTENANCE T/S PER AMM AND REPORTED ACMP NR 1 WAS AT FAULT. MTX SWAPPED ACMP NR 1 WITH ACMP 3B AND PLACED ON MEL. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100521Bracket · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE BONDING BRACKETS ON INTERNAL SIDE OF WASTE DRAIN BOX. MX REPLACED WASTE BOX P/N 170-85084-405 IAW EMB 170 SRM 51-43-02. A/C REMAINS IN CMH FOR CHECK COMPLETION.SDR R61A20100522Pin · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE LT MLG ACTUATOR PIN. MX REPLACED THE RT MLG ACTUATOR PIN P/N 1840-0006 IAW EMB 170 AMM 32-31-31. A/C REMAINS IN CMH FOR CHECK COMPLETION.SDR R61A20100518Crossbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE FLOOR CROSSBEAM AT FRAME 17 BETWEEN LT AND RT LONGITUDINAL BEAMS. MAINTENANCE REMOVED AND REPLACED THE FLOOR CROSSBEAM AT FRAME 17 IAW EMB 170 SRM 51-40-02, 51-41-02, 51-43-02 & 51-43-0SDR R61A20100517Bracket · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON NUT PLATE BRACKET ON RT SIDE OF FR 86 CROSSBEAM. MX REPLACED THE NUT PLATE BRACKET IAW EMB 170 SRM 51-41-01. P/N 120-66796-001SDR R61A20100515Shear Web · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE RT SHEAR WEB AT FR 14. MX REPLACED THE SHEAR WEB P/N 170-05663.003 DRILLED IAW EMB 170 SRM 51-40-02 AND 51-40-04 AND 51-43-03 51-41-02. A/C REMAINS IN CMH FOR COMPLETION.SDR R61A20100520Seat Track · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON FR 17-18 LT LONGITUDINAL BEAM. MX REPLACED LT SEAT TRACK IAW EMB 170 SRM 51-41-01, 51-43-01, P/N 170-03264-001. A/C REMAINS IN CMH FOR COMPLETION.SDR R61A20100519Floorbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON FLOORBEAM O/B OF RIGHT LONG BEAM AT FRAME 14. MAINTENANCE REMOVED AND REPLACED FLOORBEAM AT FRAME 14 IAW EMB 170 SRM 51-41-02, 51-43-01, 51-40-02 & 51-41-01. A/C IS CURRENTLY STILL OUT OF SDR R61A20100516Floor Support · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE RT FLOOR SUPPORT BETWEEN FR 88-90. MX REPLACED RT FLOOR PANEL SUPPORT P/N 170-86181-005 IAW EMB 170 SRM 51-42-01 AND 51-43-01. A/C REMAINS IN CMH FOR COMPLETION.SDR R61A20100512Steering Sys · malfunctionedCREW REPORTED STEER FAIL MSG ON APPROACH INTO MCI. CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT AND RESET NOSE WHEEL STEERING CB PER EMB AMM, OPS CHECK GOOD. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100511Seat Track · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT LONG BEAM FROM FR14-18. MX REPLACED THE RT SEAT TRACK BEAM P/N 170-03263-001. FROM FR 12 TO FR 20 IAW EMB 170 SRM 51-40-02. A/C REMAINS IN CMH FOR COMPLETION.SDR R61A20100509Rivet · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT LONGITUDINAL BEAM AT FR 86 INTERSECTION. MX FOUND CORROSION TO BE ON RIVET HEADS ONLY. REPLACED RIVETS IAW EMB 170SRM 51-41-01. AC REMAINS IN CMH FOR COMPLETION. P/N MS20470AD-5-5.SDR R61A20100508Splice · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE SPLICE AT THE LT SHEAR PANEL AT FR 87-88. MX REPLACED THE LT SHEAR PLATE IAW EMB 175 SRM 51-42-01. P/N 170-65644-001 A/C REMAINS IN CMH FOR COMPLETION.SDR R61A20100507Panel · corrodedWHILE A/C WAS IN HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE LT SHEAR PANEL AT FR 87 AND FR 88. MX REPLACED THE LT SHEAR PANEL IAW EMB 175 SRM 51-42-02. A/C REMAINS IN CMH FOR COMPLETION. P/N 170-65927-007.SDR R61A20100506Shear Web · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE CENTER SHEAR WEB AT FR 87-88. MX REPLACED THE CENTER SHEAR WEB IAW EMB 175 SRM 51-42-01. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100505Shear Web · corroded*** WHILE AIRCRAFT WAS IN FOR HEAVY CHECK *** LEVEL 2 CORROSION WAS FOUND ON THE RT SHEAR WEB AT FR 87-88, MAINTENANCE REMOVED AND REPLACED RT SHEAR PANEL WEB AT FR 87-88 IAW EMB 170 SRM 51-42-01. A/C IS CURRENTLY STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETSDR R61A20100504Door · unknownCREW REPORTED DIFFICUTLY OPERATING THE AFT PASSENGER CABIN DOOR. MAINTENANCE PERFORMED OPS CHECK OF AFT CABIN DOOR PER EMB AMM, NO DEFECTS FOUND.SDR R61A20100499Battery Pack · no testCREW REPORTED COCKPIT EMERGENCY LIGHT WILL NOT COME ON DURING TEST. OCM TROUBLESHOT AND REPLACED THE BATTERY PACK PER EMB AMM, OPS CHECK GOOD, AND THE A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100498Beam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LONGITUDINAL BEAM AT FRAME 17. MAINTENANCE PERFORMED MAJOR REPAIR ON THE LONGIUDINAL BEAM AT FRAME 17 IAW EMBRAER ETD 2010-170/09724, EMB 170 SRM 51-10-02, 51-21-00 & 51-41-02. REF MATESDR R61A20100497Beam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND IN NUMEROUS AREAS OF THE RIGHT LONGITUDINAL BEAM FROM FRAME 12 TO FRAME 17. MAINTENANCE PERFORMED MAJOR REPAIR TO RIGHT LONGITUDINAL BEAM FROM FRAME 12 TO FRAME 17 IAW EMBRAER ETD 2010-170/097SDR R61A20100496Door · bindingCREW REPORTED L-1 DOOR WAS HARD TO OPEN. MAINTENANCE WAS DISPATCHED TO THE A/C AND PERFORMED VISUAL CHECK AND OPS CHECK OF L-11 DOOR REF EMB 170 AMM 52-11-00 AND OPS CHECK GOOD.SDR R61A20100492Skin · damagedAC N807MD HAS A MAJOR REPAIR BEING ACCOMPLISHED. DAMAGE IS FROM A PREVIOUS BIRD STRIKE ON THE RT FORWARD FUSELAGE SKIN, BETWEEN FRAMES 4 AND 5, STRINGERS 12R AND 11R. DAMAGE MEASURED AT 3.25" X 3.90" X .050. ENGINEERING ISSUED A ENGINEERING ORDER TO REPLACESDR R61A20100491Actuator · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON LT MLG ACTUATOR INBOARD BEARING. MX REPLACED ACTUATOR IAW EMB 170 AMM 32-31-01 P/N 170-70980-409.SDR R61A20100490Bolt · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON LT MLG ACTUATOR BOLT AT SHOCK STRUT. MX REPLACED ACTUATOR BOLT IAW EMB 170 AMM 32-31-01. P/N 1840-0006.SDR R61A20100489Bolt · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT MLG ACTUATOR BOLT AT SHOCK STRUT. MX REPLACED RT MLG ACTUATOR BOLT AT SHOCK STRUT IAW EMB 170 AMM 32-31-01. P/N 1840-0006.SDR R61A20100488Bushing · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL TWO CORROSION ON RT MLG INBOARD BEARING. MX REPLACED THE THE RT MLG ACTUATOR INBOARD BUSHING IAW EMB 170 AMM 32-31-01, P/N 1840-0080. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100487Fastener · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL TWO CORROSION ON THE FASTENERS FOR THE WASTE SERVICE DOOR HINGE. MX REPLACED THE FASTENERS IAW EMB 170 SRM 51-43-02. P/N MS14218AD4 A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100486Unknown · malfunctionedCREW REPORTED ODOR IN THE CABIN AFTER TAKEOFF, RETURNED TO FIELD AT MKE AND HAD EMERGENCY EQUIPMENT DISPATCHED. A/C LANDED WITHOUT INCIDENT AT MKE. MAINTENANCE WAS DISPATCHED TO THE A/C AND REPORTED THE NR 2 PACK SYSTEM WAS THE CAUSE, AND PLACED IT ON MEL 21SDR R61A20100481Plate · corrodedWHILE IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE CENTER STRESS PLATE ON FR86 AND 87. MX REPLACED THE CENTER STRESS PLATE ON FR 86 AND 87 IAW EMB 170 SRM 51-42-01. A/C REMAINS IN HEAVY FOR COMPLETION.SDR R61A20100480Plate · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON THE LT STRESS PLATE ON FR 86-87. MX REPLACED AND FABED STRESS PLATE IAW EMB 170SRM 51-31-00, AND SRM 51-42-01. A/C STILL IN HEAVY CHECK FOR COMPLETION.
Back to Embraer ERJ 170-100SU