Embraer ERJ 170-100SU
Service difficulty reports · 2,953
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A20100416Doubler · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION AROUND INTERNAL SIDE OF LAV WASTE DRAIN VALVE BOX. MX REPLACED INTERNAL DOUBLERS P/N 170-86654-003 AND P/N 170-86655-003 IAW EMB 170 SRM. A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100417Door · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON DOOR TO WASTE SERVICE PANEL INSIDE FORWARD LEFT CORNER. MX REPLACED WASTE SERVICE DOOR IAW EMB 170 SRM. A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100411Shear Plate · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE RT SHEAR PLATE BETWEEN FR-12 & FR-14. MAINTENANCE REMOVED AND REPLACED THE RT SHEAR PLATE IAW EMB 170 SRM 51-43-02 AND 51-41-02. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100413Door · lack of lubeCREW REPORTED L-1 DOOR WAS DIFFICULT TO OPEN. MAINTENANCE LUBRICATED DOOR, AND PERFORMED OPS CHECKS OF L-1 DOOR PER EMB AMM.SDR R61A20100408Windshield · crackedCREW REPORTED F/O WINDSHIELD CRACKED IN FLIGHT, CREW DECLARED EMERGENCY AND DIVERTED TO SYR, LANDED WITHOUT INCIDENT. A/C WAS FERRIED TO MKE, AND MAINTENANCE REMOVED AND REPLACED THE F/O WINDSHIELD PER EMB AMM.SDR R61A20100407Door · bindsCREW REPORTED THE L-1 DOOR WAS HARD TO OPERATE. MAINTENANCE PERFORMED OPERATIONAL CHECK OF THE L-1 DOOR PER EMB AMM, AND REPORTED NO DEFECTS FOUND.SDR R61A20100404Unknown · malfunctionedCREW REPORTED HOT BRAKES ON LANDING, AND DECLARED AN EMERGENCY. A/C CAME TO GATE WITHOUT INCIDENT. MAINTENANCE PERFORMED OPS CHECK OF BRAKES PER EMB AMM, AND NO DEFECTS WERE FOUND. A/C WAS RETURNED TO SERVICE.SDR R61A20100405Cover · out of adjustCREW REPORTED L-1 DOOR WAS HARD TO OPEN. MAINTENANCE ADJUSTED DOOR FRAME INTERIOR SEAL COVER PER EMB AMM, AND NO DEFECTS FOUND.SDR R61A20100403Light · malfunctionedCREW REPORTED EMERGENCY EXIT LIGHT IN THE FLIGHT DECK FAILED TO ILLUMINATE DURING EMERGENCY EXIT LIGHT TEST. MAINTENANCE RESET A/C POWER PER EMB AMM, AND REPORTED NO DEFECTS AFTER THAT. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100400Counterbalance · defectiveCREW REPORTED L-1 DOOR ISN'T CLOSING CORRECTLY. MAINTENANCE REMOVED AND REPLACED FWD AND AFT COUNTER BALANCE RODS PER EMB AMM, AND REMOVED AND REPLACED FWD AND AFT BELL CRANK STOP ROLL PINS PER EMB AMM.SDR R61A20100398Power Unit · inoperativeCREW REPORTED EMERGENCY EXIT LIGHT WAS INOP. MAINTENANCE REMOVED AND REPLACED ELPU NR 1 PER EMB AMM. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100399Actuator · inoperativeCREW REPORTED DURING CRUISE HAD UNCOMMANDED RUDDER MOVEMENT TO THE RIGHT, CREW DIDN'T DECLARE EMERGENCY BUT DIVERTED TO IND AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE RUDDER TRIM ACTUATOR AND TRIM CONTROL PANEL PER EMB AMM, OPS CHECK GOSDR R61A20100395Door · damagedCREW REPORTED L-1 DOOR WAS SNAGGING WHEN OPENED. MX RESECURED L-1 DOOR IAW AMM, NO FURTHER ISSUES WERE NOTED AFTER THAT.SDR R61A20100393Splice · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION AT SUB TOPCOAT CORROSION ON CENTER INTERCOSTAL SPLICE PLATE AT FR 90 FLOORBEAM PAX CABIN. MAINTENANCE REPLACED THE SPLICE P/N 170-86119-005 IAW EMB 170 SRM. A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK SDR R61A20100391Floorbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND SUB TOPCOAT CORROSION SPLICE PLATE AT O/B SIDE OF RIGHT SHEAR PANEL FR87-88.SDR R61A20100389Frame · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON FRAME 84 OUTBOARD OF LT SEAT TRACK. MAINTENANCE REMOVED CORROSION AND REPAIRED IAW EMB ETD 2010-170/06894 MATERIAL 7075 T6 .063 PO 315910. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLESDR R61A20100388Beam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE RT LONG BEAM BETWEEN FRAME 85 & 86, PAX CABIN FLOOR STRUCTURE. MAINTENANCE REMOVED AND REPLACED THE TOP SHEET AT FRAME 85 & 86 IAW EMB 170 SRM 51-40-02, 51-41-01, 51-41-02 & 51-43-03.SDR R61A20100387Beam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON PAX FLOOR LONG BEAM RT FROM FRAME 86-89 IN NUMEROUS AREAS. MAINTENANCE REMOVED AND REPLACED RT FLOOR LONG BEAM IAW EMB 170 SRM 51-40-00 & 51-43-01. A/C STILL OUT OF SERVICE FOR HEAVY CHESDR R61A20100386Splice Plate · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON SPLICE PLATE, RT PAX FLOOR STRUCTURE AT FRAME 91 CROSSBEAM. MAINTENANCE REMOVED AND REPLACED SPLICE PLATE IAW EMB 170 SRM 51-40-02, 51-40-04 & 51-41-02. A/C STILL OUT OF SERVICE FOR HEAVSDR R61A20100385Splice Plate · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE INTERCOSTAL SPLICE PLATE RT BETWEEN BEAMS AT FRAME 90 & 91. PAX CABIN FLOOR. MAINTENANCE REMOVED AND REPLACED GUSSET SPLICE IAW EMB 170 SRM 51-40-02, 51-40-04 & 51-41-02. A/C STILL SDR R61A20100384Intercostal · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE INTERCOSTAL BETWEEN FLOORBEAMS AT FRAME 90 & 91. MAINTENANCE REMOVED AND REPLACED THE INTERCOSTAL IAW EMB 170 SRM 51-40-02, 51-41-01, 51-41-02 & 51-41-04. A/C STILL OUT OF SERVICE FOSDR R61A20100383Splice Plate · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE RT LONG BEAM SPLICE PLATE AT FRAME 90, PAX CABIN FLOOR. MAINTENANCE REMOVED AND REPLACED THE SPLICE PLATE IAW EMB 170 SRM 51-40-04 & 51-41-02. A/C STILL OUT OF SERVICE FOR HEAVY CHECSDR R61A20100382Splice Plate · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, CORROSION LEVEL TWO WAS FOUND ON THE LT LONG BEAM SPLICE PLATE AT FRAME 90, PAX CABIN FLOOR. MAINTENANCE REMOVED AND REPLACED SPLICE PLATE IAW EMB 170 SRM 51-41-02 & 51-40-02. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COSDR R61A20100381Floor Support · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE RIGHT O/B FLOOR PANEL SUPPORT AT FR 84. MAINTENANCE REMOVED AND REPLACED THE RIGHT O/B FLOOR PANEL SUPPORT IAW EMB 170 SRM 51-41-01, 51-40-04 & 51-41-02. A/C STILL OUT OF SERVICE FORSDR R61A20100380Floorbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, CORROSION LEVEL TWO WAS FOUND ON LT SIDE OF FLOORBEAM AT FR 84 O/B FLOOR PANEL SUPPORT. MAINTENANCE REMOVED AND REPLACED LEFT SIDE OF FLOORBEAM PANEL SUPPORT AT FRAME 84 IAW EMB 170 SRM 51-41-02, 51-40-04 & 51-41-01. A/SDR R61A20100379Floorbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, CORROSION LEVEL TWO WAS FOUND ON LT LONG BEAM IN PAX CABIN AT FRAME 86 - 89. MAINTENANCE REMOVED AND REPLACED THE LT FLOORBEAM AT FRAME 86 - 89 IAW EMB 170 SRM 51-41-01, 51-43-03 & 51-40-02. A/C STILL OUT OF SERVICE FORSDR R61A20100378Floor Support · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE RT CABIN FLOOR PANEL SUPPORT AT FRAME 88, 89 & 90. MAINTENANCE REMOVED & REPLACED THE FLOOR PANEL SUPPORT AT FRAME 88, 89 & 90 IAW EMB 170 SRM 51-41-01 & 51-43-03. A/C STILL OUT OF SSDR R61A20100377Support · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND AT RIGHT LONG BEAM ON PAX FLOOR STRUCTURE AT FR 17. MAINTENANCE REMOVED AND REPLACED SEAT TRACK SUPPORT IAW EMB 170 SRM 51-41-00, 51-40-02, 51-41-02 & 51-43-01. A/C STILL OUT OF SERVICE FORSDR R61A20100376Structure · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON THE LAV DUMP BOX & RETAINING DOUBLER. MAINTENANCE REMOVED AND REPLACED WASTE DUMP BOX ASSEMBLY IAW EMB 170 SRM 51-40-02 & 51-43-02. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100375Floor Support · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR PANEL SUPPORT AT FRAMES 88, 89 & 90. LEFT O/B PAX CABIN FLOOR. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL SUPPORT AT FRAMES 88-90 ON LEFT O/B PAX CABIN FLOOR IAW EMB 170 SRM 51-4SDR R61A20100374Splice · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON SPLICE O/B SIDE OF LT SHEAR PANEL AT FR 87 & 88, PAX CABIN FLOOR. MAINTENANCE REMOVED AND REPLACED SPLICE IAW EMB 170 SRM 51-42-02. A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETIONSDR R61A20100373Panel · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON LT SHEAR PANEL AT FR 87 & 88 PAX CABIN FLOOR. MAINTENANCE REMOVED AND INSTALLED NEW SHEAR PANEL IAW EMB 170 SRM 51-42-01. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100372Beam · damagedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, MAINTENANCE REPORTED A DEEP BLEND AND MISSING TOP COAT ON THE LT LONG BEAM PAX CABIN FLOOR STRUCTURE AT FR 17. MAINTENANCE PERFORMED MAJOR REPAIR ON FLOOR STRUCTURE AT FR 17 IAW ETD 2010-170/06852 AND EMB 170 SRM 2, 51-2SDR R61A20100390Slide · unserviceableGENERATED WHILE A/C WAS IN HEAVY CHECK, MAINTENANCE REMOVED AND REPLACED R-2 EMERGENCY EVACUATION SLIDE PER EMB AMM, DUE TO LOOSE LACING.SDR R61A20100370Doubler · corrodedWHILE THE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND AT POTABLE WATER BOX DOUBLER. MAINTENANCE REMOVED & REPLACED DOUBLER IAW EMB 170 SRM 51-43-04. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100365A/C Pack · malfunctionedCREW REPORTED PACK 2 FAIL ON DESCENT ALONG WITH A BURNT SMELL IN CABIN, NO EMERGENCY WAS DECLARED, LANDED NORMAL IN PHL. MAINTENANCE TROUBLESHOT AND FOUND PACK 2 TO BE AT FAULT, AND PLACED ON MEL 21-51-00-1. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100363Door · bindingCREW REPORTED L-1 DOOR DIFFICULT TO OPEN FROM THE OUTSIDE. MAINTENANCE PERFORMED PASSENGER DOOR OPS CHECK PER EMB AMM, AND REPORTED NO DEFECTS WERE FOUND. ENGINEERING ISSUED RI521033 TO HAVE MAINTENANCE PERFORM FURTHER TROUBLESHOOTING FOR THIS ISSUE.SDR R61A20100357Unknown · malfunctionedCREW REPORTED L-1 DOOR WAS DIFFICULT TO OPERATE. MAINTENANCE PERFORMED OPS CHECK OF L-1 DOOR PER EMB AMM AND REPORTED NO DEFECTS WERE FOUND.SDR R61A20100356Floorbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON FLOORBEAM BETWEEN FRAMES 85 AND 86. MAINTENANCE REMOVED AND REPLACED FLOORBEAM STRAP IAW EMB 170 SRM 51-40-02, 51-41-01 AND 51-43-01. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100354Splice · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON BEAM SPLICE AT FRAME 89 FLOOR CROSSBEAM. MAINTENANCE REMOVED AND REPLACED SPLICE IAW EMB 170 SRM 51-43-03. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100353Splice · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON THE RT SHEAR PLATE O/B SPLICE AT FRAME 87 TO FRAME 88. MAINTENANCE REMOVED & REPLACED SHEAR PLATE IAW EMB 170 SRM 51-42-02. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100351Strap · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK. MAINTENANCE REPORTED LEVEL 2 CORROSION WAS FOUND ON STRAP A FRAME 66 TO FRAME 87, REFERENCE DMI 203-03098. MAINTENANCE PERFORMED MAJOR REPAIR ON STRAP AT FRAME 86 TO FRAME 87. REMOVED AND REPLACED STRAP IAW EMB 170 SRMSDR R61A20100350Doubler · corrodedWHILE A/C WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND AROUND WATER SERVICE PANEL INTERNAL SIDE. MAINTENANCE REPLACED DOUBLER P/N 170-866655-03 IAW EMB 170 SRM. A/C IS STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100349Gust Lock · out of adjustCREW REPORTED L-1 DOOR WAS HARD TO CLOSE. MAINTENANCE ADJUSTED THE GUS LOCK PER EMB AMM, AND PERFORMED OPS CHECKS. THE A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100344Floor Support · corrodedWHILE A/C WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND AT L1 DOOR OPENING, FRAME 19 FLOORBOARD SUPPORT. MAINTENANCE REMOVED AND REPLACED SHEAR PANEL IAW EMB 170 SRM 51-41-02 & 51-43-02. P/N 170-07311-001.SDR R61A20100343Doubler · corrodedWHILE A/C WAS IN HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND AT THE WATER SERVICE PANEL DOUBLER. MAINTENANCE REMOVED & REPLACED DOUBLER ON WATER SERVICE PANEL IAW EMB 170 SRM 51-43-02. P/N 170-86656-003.SDR R61A20100342Skin · damagedGENERATED WHILE A/C WAS IN HEAVY CHECK. MAINTENANCE REPORTED FUSELAGE SKIN DAMAGED BETWEEN FRAMES 23 AND 24 LT BELOW CABIN WINDOW. MAINTENANCE PERFORMED MAJOR REPAIR AT FWD FUSELAGE SKIN FR 23 AND 24 BELOW L1 CABIN WINDOW IAW EMB 170 SRM 51-75-12 AND 51-21-0SDR R61A20100341Service Panel · corrodedWHILE A/C WAS IN HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON THE LAV WASTE BOX STATION 22270.0 TO 22680.0 STRINGER 26. MAINTENANCE REMOVED & REPLACED WASTE BOX IAW EMB 170 SRM 51-43-02. P/N 170-65078-403.SDR R61A20100340Floor Support · corrodedGENERATED WHILE A/C WAS IN HEAVY CHECK. RIGHT SIDE FLOOR PANEL SUPPORT SPANNING FLOOR CROSSBEAMS AT FR88, FR89 AND FR90. LEVEL TWO CORROSION WAS FOUND. MAINTENANCE REMOVED AND REPLACED RT PANEL SUPPORT IAW EMB 170 SRM 51-41-01, 51-42-00 & 51-43-01. P/N 170SDR R61A20100339Support · corrodedGENERATED WHILE A/C WAS IN HEAVY CHECK. FROM R1 DOOR OPENING AT FR14 TO FR13, LEVEL 2 CORROSION WAS FOUND ON GALLEY SUPPORT/FLOOR BEAMS. MAINTENANCE REMOVED & REPLACED WEB FORWARD OF R1 DOOR IAW EMB 170 SRM 51-43-04 & 51-41-02. P/N 170-05663-003.
Back to Embraer ERJ 170-100SU