Mcdonnell-Douglas DC-10-10F
Service difficulty reports · 510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1010F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1010F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 01FDEA00094Web · crackedDURING D-CK, 1 INCH CRACK FOUND AT Y=1386 ON AEA0501-2 KEEL WEB UPPER SPLICE ONLY. REMOVED AND REPLACED TITANIUM REPAIR DOUBLER PER IAW FEDEX EA 8-5314-56044.SDR 00FDEA00904Proximity Switch · faulty00-378 LEFT GEAR UNSAFE LIGHT ILLUM. R&R PROX SWITCH ELECTRONIC CONTROL UNIT IAW DC10-10 MM 32-61-01-2. PERF GEAR RETRACTION AFT PROX ELEC UNIT REPLACEMENT NO DEFECTS NOTED. SYS OPERATES NORM PER MM 7-11-00 & MM 32-30-00.SDR RRXA001099Valve · failedWHEN WING ANTI-ICE IS TURNED ON - RIGHT 1506 VALVE DISAGREE LIGHT COMES ON WITH NO DROP IN PNEU PRESS FEFI CODE 30-11-00. REMOVED AND REPLACED RIGHT WING ANTI-ICE VALVE IAW M/M 30-00-00. OPS OK ON CHECK.SDR 00FDEA00883Fire Loop · chafed00-362 DURING NR 2 ENGINE START, VALVE CLOSED. WE A GOT FIRE INDICATION ON NR 2 B-LOOP. R&R BOTTLE AND CLEANED CONNECTOR PLUG P1-8004 & P1-8006. R&R FAN FIRE DETECTOR LOOP A+B ASSY. CANNON PLUG P1-1255 NEEDS TO BE REPLACED.SDR RRXA001088Link · wornAFTER TAKEOFF AND AFTER GEAR RETRACTION HEAVY VIBRATION WAS FELT IN THE NOSE WHEEL GEAR RETURNED BACK TO LAX AND AFTER PARKING FOUND RIGHT NOSEGEAR DOOR IN THE OPEN POSITION *** CORRECTIVE ACTION *** INSPECTED NOSE AREA FOUND RIGHT DOOR DOWN ON ARRIVAL FOUSDR RRXA001087Engine · failedAFT V1 NR 1 ENGINE EGT WENT TO 910 DEG, N1 FELL TO 82 PERCENT, N2 FELL TO 85 PERCENT, FUEL FLOW INCREASED TO ABOUT 15,000LBS PER HR. NO LIMITS OR RED LINES WERE APPROACH EWD. LEVELED OFF AT 18,000FT, EGT AND FUEL FLOW CONTINUED TO INCREASE. EVENTUALLY PULLESDR 00FDEA00851Coalescer Bag · odor00-339 CR FL330 HEAR LOUD BANG. SOUND FROM BEHIND BARRIER. SMELL BURNING. ** S/D ** R&R WATER SEPARATOR SOCKS, AUTO PRESS SEL, STBY PRESS CONTROLLER PER MM 21-54-03-2, 21-31-03-2, 21-31-05-2. NO LEAKS NOTED. INSP PACK BAYS FOR LEAKS, BUTN AND OVERHEAT COSDR 00FDEA00765Wire · corrodedAFT T/O LAND GEAR RT LIGHT REMAIN ON BOTH PANEL WITH GEAR HANDLE UP. RE-TERMINATED WIRES AT TERMINAL S3-681 PER DOUG WIRE STANDARD. PERF GEAR RETRACT, OPS CK OK.SDR 00FDEA00757Skin · delaminatedLT OUTBOARD, ELEVATOR HAS DELAMINATION ALONG TRAILING EDGE. REPAIRED AND BALANCED PER DC10 SRM 55-30-00 VOL I, SRM 55-20-00.SDR 00FDEA00746Fuel Control · sluggishUPON ROTATION NR 2 FUEL FLOW AROUND 5000. 1 & 3 10000 F/F N1 33 PERCENT, N2 97 PERCENT EGT 700. AC WOULD NOT CLIMB, VERY SLUGGISH.SDR 00FDEA00728Engine · inoperativeNR 2 ENGINE FLAMED OUT NOTICED WHEN ENGINE ANTI-ICE TURN ON AND NR 2 A/I DISAGREE LIGHT CAME ON. *S/D* REMOVED AND REPLACED LINE ENGINE, OPS CK OK.SDR RRXA001065Actuator · failedAS ACFT SPEED INCREASES ACFT WANTS TO ROLL TO THE RIGHT FLAPS/SLATS RETRACTED. REMOVED AND REPLACED RIGHT INBOARD AILERON ACTUATOR IAW DC-10 MM 27-13-01 PAGES 401 - 407. OPS AND LEAK CHECKS GOOD.SDR RRXA001061Floor Panel · damagedSEVERAL HOLES IN FLOOR CENTER OF POSITIONS 3R & 3L & AFT OF BALLMAT (FACING AFT). *S/D* INSTALLED NR 3 POS CENTER PNL IAW DC-10 M/M 25-50-67.SDR RRXA001060Angle · brokenRIGHT LANDING GEAR RED LIGHT ON AFTER GEAR RETRACT. WHILE T/S FOUND DOOR STRIKER BROKEN OFF. REPLACED DOOR STRIKER, PERFORMED OPS CHECK IAW DC-10-10 M/M 32-34-03 ITEMS 17, 18, 19, 20, SYS OPS CHECKS GOOD.SDR RRXA001053Warning System · activatedWHEN EXTENDING FLAPS FOR LANDING, SLAT DISAGREE LIGHT ILLUMINATED. PERFORMED APPROPRIATE ABNORMAL CK LISTS, LANDED KDFW. OPERATED FLAPS/SLATS PER DC-10 MM 27-80-00 PG 538 THRU 542. ALL OPS CHECK NORMAL. VISUALLY CHECKED SLATS FOR DAMAGE AND OPS, NO DEFECTSSDR 00FDEA00560Panel · missingPANEL MISSING RIGHT UPPER THRUST REVERSER ASSY. INSTALL MISSING PANEL PER IAW SMP. OK FOR SERVICE. NO PARTS REMOVED.SDR 00FDEA00548Limit Switch · inoperativeAFT T/O REVERSER UNLOCK LIGHT CAME ON NR 3 ENG NO ASSOCIATED PROBLEMS. NR 3 THRUST REVERSER INOP. *S/D* REMOVED AND REPLACED NR 3 LT AND RT DRIVE CABLES, REMOVED AND REPLACED SWITCH RIGGED IAW MM DC10-10 78-32-17-2, PDU IAW DC10-10 MM 78-31-01-2.SDR 00FDEA00535Engine · vibrationNR 1 ENGINE VIBRATES AT 85 PERCENT N1 AND INCREASES AS PWR IS INCREASED TO T/O. VIB CAN BE DUP ON GROUND. VIB IS FELT IN NR 1 START LEVER AND COCKPIT FLOOR. NO VIB IS FELT IN ANY OTHER THROTTLE. *S/D* REMOVED AND REPLACED, SEE WORK CARD 71T0701-1.SDR 00FDEA00536Gearbox · crackedNR 1 ENGINE HAS 6 INCH CRACK ALONG AFT FACE OF MAIN GEARBOX JUST ABOVE THE LUGS THAT MOUNT THE FORE-AFT ANTI-ROTATION SUPPORT AT 6 O''CLOCK POS. *S/D* REMOVED AND REPLACED PER WORK CARD 71T0701-1.SDR 00FDEA00534Engine · malfunctionedCLIMBING OUT OF 10,000 FT NR 3 ENGINE ROLLED BACK TO IDLE WITH A COMPLETE LOSS OF THROTTLE CONT: REPEAT WRITE-UP. AFT ROLL BACK ENG STAB. *S/D* REMOVED AND REPLACED NR 3 ENGINE PER W/C 71T0101-3.SDR 00FDEA00522Engine · failedAFT DEPARTURE, NR 3 ENGINE ROLLED BACK TO IDLE. VIBRATION SOON AFT T/O AND CONTINUE UNTIL ENGINE FAILED. *S/D* REMOVED AND REPLACED PER MM 73-20-01-2.SDR 00FDEA00524Engine · failedAFT DEPARTURE NR 3 ENGINE FAILED, CKLIST PERFORMED, RETURN TO LAX. NOTED VIBRATION AFT T/O CONTINUE UNTIL ENGINE FAILED. *S/D* ACCOMPLISH BORESCOPE ON NR 3 ENG IAW W/C 72X3503, NO DEFECTS NOTED. ENGINE IS SERVICEABLE.SDR 00FDEA00520Mount · corrodedNR 14 CORROSION FOUND ON NR 3 ENGINE AT AFT MOUNT ASSY. *S/D* REPLACED PER MM 20-20-01-2 DAC BLUE PRINT AUB 7032.SDR 00FDEA00506Uplock Sensor · inoperativeAFT T/O, GEAR RETRACTION UNSAFE RED IND IN BOTH S/O AND MAIN PANEL RT MAIN GEAR IND (RED LIGHT) ILLUM. REMOVED AND REPLACED RT GEAR UPLOCK SENSOR AND CORRECTLY ROUTED CONDUIT IAW MM 32-61-03-2. REMOVED AND REPLACED PROX BOX IAW 32-61-01-2. OPS CK OK.SDR 00FDEA00503Connector · looseAFT T/O, GEAR RETRACTION UNSAFE IND IN BOTH S/O AND MAIN PNL, RT MAIN GEAR IND RED LIGHT ON. FOUND UPLOCK PROX SENSOR CANNON PLUG ON LOOSE. TIGHTENED C/P AND SAFETIED PLUG ASSY, PERF PROX BOX TEST IAW MM 32-30-00 PG 104 & 32-30-00. OPS CK NORM. OK FOR SERVSDR RRXA11057Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT ANGLES AT STA 174, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART AND INSTALLED IAW DC-10 SRM 51-35-01, 51-10-00.SDR RRXA10692Skin · crackedDURING MAINTENANCE VISIT FOUND CRACK DAMAGE TO RT FUSELAGE SKIN AT STA 1154 - 1160. DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-10 SRM 51-21-01. FABRICATED REPAIR AND INSTALLED IAW DC-10 EA 10-5331-22-A07A1.SDR 00FDEA00502Web · crackedLWR TORQUE BOX (Y) 2122.8 (X) -40, WEB HAS CRACK IND ADJACENT TO FASTENER COLLAR AT UPPER EDGE JUST I/B OF RIGHT HORIZ STAB PIVOT SUPPORT INSIDE DOOR 316BB. *S/D* REMOVED AND REPLACED PER EA 8-5310-49669.SDR 00FDEA00501Fastener · brokenRT HORIZ STAB PIVOT SUPPORT, LOWER HALF, HAS 2 BROKEN FASTENERS WHERE PRIMARY AND SECONDARY ATTACH TO UPPER EDGE OF LOWER TORQUE BOX. (Y) 2122.8 (X) -41.7 INSIDE DOOR 316BB. *S/D* REMOVED AND REPLACED FASTENERS PER SRM 53-00-01.SDR RRXA11054Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT JAM AFT OMNI ROLER FITTING AT STA 1761 AND X=-70, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. RECEIVED PART AND INSTASDR RRXA11053Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT TOURQE BOX WEB AT STA 1721 AND X=-70, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART AND INSTALLED IAW DSDR RRXA11058Channel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT AFT LOAD RESTRAINT BLOCK CHANNEL AT STA 1781 AND X= -25, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART SDR RRXA11062Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT FLOOR PANEL SUPPORT AT STA 1701 AND X= -21, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART AND INSTALLEDSDR RRXA11059Plate · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT ROLLER TRAY ATTACH PLATE AT STA 1701 AND BL=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART AND INSTALLED IAW DC-10 SRM 51-31-4.SDR RRXA11061Roller Tray · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT CENTER LINE ROLLER TRAY AT STA 1601-1701 AND X=2 TO X= -2, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED PART AND INSTALLED IAW DC-10 SRSDR RRXA11060Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FWD PIT SIDE RAIL AT STA760 AND X=60, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01.FABRICATED PART AND INSTALLED IAW DC-10 SRM 57-31-01.SDR RRXA10691Structure · damagedDURING MAINTENANCE VISIT FOUND INTERIM DAMAGE TO STA 1156 AND L39L, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-10 SRM 51-21-01. RECEIVED PART AND INSTALLED IAW DC-10 EO DM-5312-01-00.SDR RRXA10690Mount · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMANGE TO NR 3 ENGINE PYLON AFT MOUNT, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-10 SRM 51-21-01. RECEIVED PART AND INSTALLED IAW DC-10 SRM 20-50-02. (CORROSION DAMAGE RECORDEDSDR RRXA11052Door · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SKIN ON PANEL #518CB AT XORS372 AND X=-400, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-10 SRM 51-21-01. FABRICATED PART AND INSTALLED IAW DC-10SDR RRXA11063Fastener · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO NR 2 ENGINE LEFT CORE COWL, FWD HINGE MOUNT 4EA FASTNERS, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. RECEIVED PART AND INSTALLED 4EA FASTNERS IAW DC-10 SRMSDR RRXA10689Sill · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FWD CARGO COMPARTMENT LOWER DOOR SILL TRAY AT STA 939 AND L43R, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. TREATED AREA IAW DC-10 SRM 51-21-01. RECEIVED PART AND INSTALLED IAW DC-10 SRM 51-31-01. (CORROSISDR RRXA10688Spar · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE LEFT HAND WHEEL WELL BETWEEN TRAPEZOID AND REAR SPAR OF CENTER WING ON INBOARD AND OUTBOARD LEGS AT STA 1392 AND LBL 118.2, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DCSDR RRXA11056Bushing · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO #3 A/C DOOR HANDLE TOURQE TUBE BUSHINGS AT STA 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01.RECEIVED PART AND INSTALLED IAW DSDR RRXA11051Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RT WING NR 1 SLAT TRACK ATTACH FITTING AT STA XIS285, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-10. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-10-00 FIG 31.SDR RRXA11055Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FWD CARGO FLOOR SUPPORT ANGLE AT STA 905-910 AND X=48, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. FABRICATED REPAIR AND INSTALLSDR 00FDEA00419Skin · corrodedLEFT WING O/B AILERON LWR SKIN IS CORRODED AFT OF CENTER HINGE POINT. *S/D* REMOVED AND REPLACED PER SRM 51-00-01.SDR 00FDEA00413Engine · failed00-169 AT 11000 FT PWR REDUCTION. FELT LIKE COMPRESSOR STALL. ON APPROACH SEVERE VIBRATION AND NR 2 ENGINE FAILED. BORESCOPED ENGINE, FOUND TIP CLANG DUE TO STALL. REMOVED ENGINE. DID PYLON INSPECTION DUE TO ENGINE FAILURE.SDR 00FDEA00405Proximity Switch · failedON GEAR RETRACT AFT T/O, LEFT MAIN GEAR RED LIGHT ILLUM. ACCOMPLISH RED TAB PROC. REMOVED AND REPLACED PROXIMITY ELECTRONIC UNIT IAW DC-10-10 MM 32-61-01-2. PERFORMED LANDING GEAR EXT AND RETRACT CK IAW DC10-10 MM 32-30-00-5. SYS OPS CHECK NORM.SDR RRXA001004Coalescer Bag · dirtyAFTER TAKEOFF, WHEN NR 1 PACK IS TURNED ON WITH NR 1 ENG PANEL SUPPLING AIR, EXPERIENCED BURNING SMELL. TURNED PACK OFF FOR REMAINDER OF FLT. OPERATED WITH NR 2 & 3 PACK. OCCURRED WITH PACK NR 1 IN AUTO + MIX IN FULL HOT ON GROUND WITH PACK NR 1 IN MAN FULLSDR RRXA000999Computer · failedON TAKEOFF STICK SHAKER ACTIVATED AND AUTO SLAT EXTEND ACTIVATED WITH SLAT RESET LIGHT ON. RAN CK LIST, NO HELP. COULD NOT RESET SLATS, RESET STICK SHAKER CB'S, NO HELP. SLATS REMAINED IN AUTO EXTEND POSITION. REMOVED AND REPLACED AT/SC NR 2 COMPUTER STICK
Back to Mcdonnell-Douglas DC-10-10F