Mcdonnell Douglas DC-10-15
Service difficulty reports · 338
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA99562Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 440 TO 470 AT RBL 85 WAS FOUND TO BE CORRODED. SEAT TRACK WAS FOUND TO BE EXFOLIATED COMPLETELY THROUGH. SEAT TRACK WAS REMOVED AND REPLACED.SDR SCNA99561Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1841 X EQUALS PLUS 27 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW SEAT TRACK PER SRM 537000.SDR SCNA99560Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT DOG BONE AT STA 1841 X PLUS 10 TO 26 WAS FOUND TO BE CORRODED. REMOVED FABRICATED AND INSTALLED FLOOR SUPPORT PER SRM 513101.SDR SCNA99559Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 795 TO 825 LBL 6 WAS FOUND TO BE CORRODED. FABRICATED SEAT TRACK PER SAMPLE AND INSTALLED PER SRM 537000.SDR SCNA99558Splice · corrodedDURING A HEAVY MAINTENANCE CHECK THE HAT SPLICE NEEDS TO BE FABRICATED FROM STA 795 TO 859 AT X MINUS 50 IN CONJUNCTION WITH SEAT TRACK REPAIR AT SAME STA. FABRICATED AND INSTALLED SPLICE HAT PER SRM 5370 FIG 1.SDR SCNA99557Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE LOWER AFT RT GALLEY BOTTOM FLANGE WAS FOUND CORRODED. REMOVED FABRICATED ANGLES AND INSTALLED PER SAMPLE.SDR SCNA99556Support · corrodedDURING A HEAVY MAINTENANCE CHECK, ALL LAVATORY SUPPORT RAILS FROM STA 1841 TO 1886 36LT TO 36RT WERE FOUND TO BE CORRODED. REMOVED AND INSTALLED NEW LAV SUPPORTS PER SRM 513101.SDR SCNA99555Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1902 TO 1965 WAS FOUND TO BE CORRODED. CORROSION REMOVED WAS FOUND TO BE OUT OF LIMITS. REMOVED SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW 537000.SDR SCNA99554Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT AT STA 825 FROM RBL 30 TO RBL 50 WAS FOUND TO BE CORRODED. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT AND INSTALLED PER SRM 513301.SDR SCNA99553Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT AT STA 1887 X EQUALS PLUS 91 TO MINUS 91 WAS FOUND TO BE CORRODED. REMOVED FABRICATED AND INSTALLED NEW FLOOR SUPPORT PER SRM 513501.SDR SCNA99552Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT CHANNEL AT STA 440 RBL 70 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED NEW SUPPORT PER SRM 513101.SDR SCNA99551Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT DOG BONE AT STA 1914 X MINUS 54 WAS FOUND TO BE CORRODED. REMOVED CORRODED FLOOR SUPPORT DOG BONE AND INSTALLED NEW FLOOR SUPPORT PER SRM 513101.SDR SCNA99550Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR BOARD SUPPORT AT STA 1902 TO 2607 X MINUS 57 WAS FOUND TO BE CORRODED. REMOVED CORRODED SUPPORT FOUND OUT OF LIMITS. INSTALLED NEW SUPPORT PER SRM 513101.SDR SCNA99549Tie Down · corrodedDURING A HEAVY MAINTENANCE CHECK, THE TIE DOWN CHANNEL AT STA 795 TO 859 WAS FOUND CORRODED AT RBL 50. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED FABRICATED AND INSTALLED NEW TIE DOWN CHANNEL PER SRM 537000 FIG 1 VOLUME 1.SDR SCNA99548Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 414 X MINUS 20 WAS FOUND CORRODED ON THE UPPER SURFACE. REMOVED CORROSION MATERIAL LOSS FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 513101.SDR SCNA99547Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 495 X PLUS 62 Z MINUS 18 WAS FOUND CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED AND REINSTALLED NEW FLOOR SUPPORT IAW SRM 513501 AND 512101.SDR SCNA99546Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1841 X PLUS WAS FOUND CORRODED. REMOVED CORROSION FOUND OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK PER SRM 537000.SDR SCNA99545Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 459 X PLUS 20 Z MINUS 18 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED FABRICATED AND REINSTALLED FLOOR SUPPORT IAW 511001 FIG 17 AND 513501.SDR SCNA99544Support · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 459 X MINUS 30 AND Z MINUS 18 WAS FOUND CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT FABRICATED AND REINSTALLED FLOOR SUPPORT PER SRM 513101.SDR SCNA99543Channel · corrodedDURING A HEAVY MAINTENANCE CHECK IN THE AFT CARGO PIT STA 1841 TO 1964 RT SIDE LOWER CENTER FLOOR TO LOWER SIDE FLOOR Z CHANNEL HAS CORROSION ON ENTIRE LENGTH. REMOVED CORROSION AND WAS FOUND OUT OF LIMITS. REMOVED AND INSTALLED NEW CHANNEL PER SRM 513101.SDR SCNA99542Seat Track · corrodedDURING A HEAVY MAINTENANCE CHECK, SEAT TRACK AT STA 465 48 RT IN THE MAIN CABIN WAS FOUND CORRODED. REMOVED AND REPLACED SEAT TRACK PER SRM 537000.SDR SCNA99541Intercostal · corrodedDURING A HEAVY MAINTENANCE CHECK INTERCOSTAL AT STA 495X EQUALS PLUS AND MINUS 45 WAS FOUND CORRODED AT THE UPPER END. 100 PERCENT MATERIAL LOSS WAS NOTED. REMOVED INTERCOSTAL AND INTERCOSTAL UPPER CAP. FABRICATED NEW INTERCOSTAL AND INSTALLED PER SRM 512101SDR SCNA99540Oxygen Gen · dischargedDURING A HEAVY MAINTENANCE CHECK, THE OXYGEN GENERATOR AT SEAT 20D AND 20E WAS FOUND DISCHARGE. REMOVED AND REPLACED OXYGEN GENERATOR PER MM 352003.SDR SCNA99539Angle · corrodedDURING A HEAVY MAINTENANCE CHECK IN THE AFT CARGO COMPARTMENT CORROSION WAS FOUND AT STA 1964 AT LBL 50 TO RBL 50. REMOVED AFT THRESHOLD ANGLE AND FABRICATED NEW THRESHOLD ANGLE AND INSTALLED.SDR SCNA99538Web · crackedDURING A HEAVY MAINTENANCE CHECK IN THE CARGO BAY STA 1541 AT LGR 43L WAS FOUND TO HAVE A 1 INCH CRACK IN THE WEB UNDER THE CARGO ROLLER TRACKS. REMOVED WEB AND FABRICATED A NEW ONE PER SRM 512101 AND 513000.SDR SCNA99116Bulb · failedDURING A LINE MAINTENANCE CHECK, AN EMERGENCY TRACK LIGHT BY SEAT ROW 6 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE LIGHT BULB IN THE EMERGENCY TRACK BY SEAT ROW 6 RIGHT SIDE. OPERATIONALLY CHECKS GOOD.SDR SCNA99107Skin · corrodedDURING A SCHEDULED MAINTENANCE CHECK, FUSELAGE SKIN WAS FOUND BULGED BETWEEN STA 1019 AND 1059 ON THE LEFT LOWER FUSELAGE AREA. CUT OUT CORROSION AND FABRICATED A PATCH, DOUBLER AND TRIPLER PER SRM VOLUME 1 532000 FIGURE 6 AND INSTALLED A CLASS II REPAIR.SDR SCNA99104N1 Sensor · inoperativeAIRCRAFT ABORTED TAKEOFF AT 120 KNOTS AS NUMBER TWO ENGINE DIDN'T MAKE REDUCED N1. OPERATIONALLY CHECKED THE NUMBER TWO ENGINE IAW DC-10 MM 710000. OPERATIONALLY CHECKED AIRCRAFT PER MM 055700 AFTER HIGH ENERGY STOP. REMOVED AND REPLACED THE NUMBER TWO ENGISDR SCNA99094Coffeemaker · failedDURING FLIGHT, NUMBER THREE COFFEEMAKER SPARKED THEN THE GALLEY POWER TRIPPED OFF LINE. GALLEY COFFEEMAKER CIRCUIT BREAKERS THEN PULLED. REMOVED AND REPLACED THE COFFEMAKER AND CHECKED ALL ELECTRICAL TERMINALS. RESET CIRCUIT BREAKER AND OPERATIONALLY CHECKSSDR SCNA99079Light · inoperativeDURING A LINE MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING ON THE RIGHT SIDE AT SEAT ROW 37 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY PATH LIGHTING ASSEMBLY AT SEAT ROW 37 ON THE RIGHT SIDE. OPERATIONALLY CHECKS GOOD.SDR SCNA99080Light · inoperativeDURING A LINE MAINTENANCE CHECK THE FORWARD CABIN OVERWING EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY ASSEMBLY AND FOUND A SHORT IN THE WIRING IN THE RIGHT SIDEWALL MID CABIN. OPERATIONALLY CHECKS GOOD.SDR SCNA99509Switch · failedDURING A HEAVY MAINTENANCE VISIT, DURING COMPLETION OF A CABIN LEAK CHECK THE ALTITUDE WARNING HORN FAILED TO GO OFF WHEN THE CABIN ALTITUDE REACHED 12,000 FT. REMOVED AND REPLACED THE CABIN ALTITUDE SWITCH AND THE SYSTEM OPERATIONALLY CHECKS GOOD IAW DC10 MMSDR SCNA99508Sensor · misinstalledDURING A HEAVY MX CHECK TEST FLT, THE LT MAIN GEAR UNSAFE RED LIGHT ILLUM WHILE ROTATING AND EXTINGUISHED IN FLIGHT. THE CREW TROUBLESHOT AND RETURNED TO POINT OF ORIGIN. THE FLT CREW VERIFIED THE DOWN POSITION WITH THE VIEWING PORTS, BRIEFED THE PASSENGERS SDR SCNA99506Angle · corrodedDURING A HEAVY MAINTENANCE CHECK, THE 'L' ANGLE AT STATION 567 TO 595 AT LONGERON 44L WAS FOUND TO HAVE CORROSION AND MATERIAL LOSS WAS GREATER THAN 20 PERCENT THE ORIGINAL THICNESS WAS .090 AND FOUR AREAS AFTER WERE .060 AND .074 AND .072 AND .073. THE SUBJSDR SCNA99505Spar · crackedDURING A HEAVY MAINTENANCE CHECK, THE LEFT HORIZONTAL STABILIZER OUTBOARD SECTION UPPER SPAR CAP FORWARD WAS FOUND CRACKED AT THE FORWARD CLOSING RIB PLANE THE CRACK WAS APPROXIMATELY 4.40 INCHES WHICH EXCEED ALLOWABLE LIMITS PER SB DC10 55-24. THE SUBJECT SPSDR SCNA99504Skin · chafedDURING A HEAVY MAINTENANCE CHECK, THE RIGHT LEADING EDGE SKIN ARB1074 WAS FOUND TO BE CHAFED AT STA XOS 551 TO XOS 555 WITH .043 REMAINING OF ORIGINAL THICKNESS OF .063. THE SUBJECT LEADING EDGE WAS REPAIRED PER SRM 571000 FIG 15 AND EO 57-5678-1.SDR SCNA99503Switch · failedDURING A HEAVY MAINTENANCE CHECK, 2 ANEROID SWITCHES FOR THE PASSENGER OXYGEN SYSTEM FAILED TEST FOR SCA WORK CARD X1036. THE SUBJECT ANEROID SWITCHES 2 WERE REMOVED AND REPLACED PER MM 352102, OPERATION CHECK WAS GOOD.SDR SCNA99507Battery Pack · dischargedDURING A HEAVY MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING WAS FOUND TO BE INOPERATIVE FROM SEAT 8L TO 15L AND 8R TO 15R. REMOVED AND REPLACED THE BATTERY PACK PER MEXICANA EO 1033014, OPERATIONAL CHECK GOOD.SDR SCNA99502Support · crackedDURING A HEAVY MAINTENANCE CHECK, AFT GALLEY FLOOR SUPPORT AT STA 1902 WAS FOUND TO BE CORRODED ON UPPER AND LOWER SURFACES RHX=8 AND BARE METAL X=1 TO X=23 CRACKS WERE FOUND AT FOOT ATTACHMENTS. FABBED NEW FLOOR SUPPORT INSTALLED PER SRM 513501.SDR SCNA99501Support · corrodedDURING A HEAVY MAINTENANCE CHECK, AFT GALLEY FLOOR SUPPORT AT STA 1910 WAS FOUND TO BE CORRODED BETWEEN X=27.5 AND X=MINUS 27.5 RT. REMOVED CORROSION FOUND TO BE OUT OF LIMITS FABBED STRAP FOR FLOOR PANEL SUPPORT TREATED PRIMED AND INSTALLED PER SRM REFS 5121SDR SCNA99500Support · crackedDURING A HEAVY MAINTENANCE CHECK, 2EA FLOOR SUPPORTS STA Y=1986 CL=0 AND X+27.5 ARE CRACKED AT INBD ENDS AND ALSO WERE FOUND CORRODED. REMOVED FABRICATED ALODINED PRIMED AND INSTALLED FLOOR SUPPORTS 2EA PER SRM 511000 512101 AND 513000.SDR SCNA99062Acm · malfunctionedDURING CLIMBOUT, THE DUCT-AVIONIC COMPARTMENT OVERHEAT LIGHT ILLUMINATED. CABIN ALTITUDE COULD NOT BE REGULATED AND CONTINUED CLIMBING A 750 FPM. RETURNED AIRCRAFT TOMSP. ON TAXI IN SMOKE REPORED IN THE AFT CABIN. FOUND THE NR 1 AIR CYCLE MACHINE TO BE WEASDR SCNA99057Cover · out of positionDURING A LINE MAINTENANCE CHECK, THE L1 DOOR WOULD NOT RELEASE FROM THE DOOR OPENING. FOUND THE LOWER ESCAPE SLIDE COVER JAMMED INTO DOOR FRAME WITH ENOUGH PRESSURE TO LOCK THE DOOR INTO THE FRAME. OBSTRUCTING DOOR SLIDE COVER REMOVED FROM DOOR FRAME AND DOOSDR SCNA99056Battery Pack · dischargedDURING A LINE MAINTENANCE CHECK, THE FORWARD AND MID CABIN EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. RE MOVED AND REPLACED THE FORWARD AND MID CEILING LIGHT BATTERY PACKS. SYSTEM OPERATIONALLY CHECKS NORMAL.SDR SCNA99055Oxygen Bottle · failedDURING FLIGHT, A PASSENGER PORTABLE OXYGEN BOTTLE FAILED. REMOVED AND REPLACED THE PORTABLE OXYGEN CYLINDER.SDR SCNA99054Door · out of adjustDURING A SCHEDULED MAINTENANCE CHECK, THE O2 MASK DOOR FAILED TO OPEN AT THE FLIGHT ATTEDNANT L1 POSITION. FOUND THE DOOR BINDING IN OPENING. ADJUSTED DOOR AND OPERATIONALLY CHECKS GOOD.SDR SCNA99052Tire · failedDURING LANDING ROLL, THE NR 8 MAIN LANDING GEAR TIRE BLEW. ROLL OUT WAS UNEVENTFUL. REMOVED AND REPLACED THE NR 8 MAIN LANDING GEAR TIRE ASSEMBLY.SDR SCNA99047Sensor · failedDURING A LINE MAINTENANCE CHECK, THE RIGHT STALL WARNING FAILED THE SELF TEST. REMOVED AND REPLACED THE ANGLE OF ATTACK SENSOR IAW MM 223301. SYSTEM OPERATIONALLY CHECKS GOOD.SDR SCNA99038Tire · failedDURING LANDING, THE NR 8 MAIN TIRE BLEW OUT. REMOVED AND REPLACED THE NR 8 AND NR 7 TIRE PER MM 324101.SDR SCNA99026Wire · failedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK AFT OF THE R1 DOOR WAS FOUND TO BE INOPERATIVE. REPAIRED WIRES ON THE EMERGENCY EXIT TRACK, OPERATIONALLY CHECKS GOOD.
Back to Mcdonnell Douglas DC-10-15