SDR SCNA99025Oven · failedTHE AFT OVEN, 2ND ONE FROM THE AFT, FAN SMOKES WHEN TURNED ON. REMOVED AND REPLACED THE OVEN, OPERATIONALLY CHECKS GOOD.Jan 28, 1999 · N153SY · Doug DC1015 · Buffet/GalleysSDR SCNA99017Batteries · dischargedDURING A LINE MAINTENANCE CHECK, THE L2 EMERGENCY SLIDE LIGHT WAS FOUND TO BE INTERMITTENT AND THE SLIDE LIGHT BATTERY CONTACTS WERE FOUND BROKEN. SECURED THE SLIDE LIGHT BATTERIES IN THE HOLDER.Jan 20, 1999 · N153SY · Doug DC1015 · Emergency LightingSDR SCNA99033Control Cable · out of adjDURING APPROACH, GEAR WOULD NOT EXTEND NORMALLY, GEAR HANDLE WOULD NOT MOVE FURTHER THAN HALF TRAVEL. LANDING GEAR EXTENDED USING ALTERNATE SYSTEM. LANDED AIRCRAFT UNEVENTFULLY. FOUND EXTEND CABLE ABOVE RIGHT WHEEL WELL CEILING BULKHEAD OFF OF PULLEY. REINJan 18, 1999 · N153SY · Doug DC1015 · Landing Gear Retraction/Extension SystemSDR SCNA99016Coalescer · contaminatedDURING CLIMB, CABIN FILLED WITH SMOKE. COMPLIED WITH COM AND SMOKE STOPPED WHEN NR 2 PNEUMATIC SUPPLY AND NR 2 PACK SELECTED TO OFF. DIVERTED AIRCRAFT TO ORD FOR A PRECAUTIONARY LANDING. FOUND NR 3 ENGINE WITH NR 3 PACK ON CAUSING OIL FUMES IN THE CABIN AT Jan 17, 1999 · N154SY · Doug DC1015 · Humidity Control SystemSDR SCNA99002Wire · pinchedDURING FLIGHT, THE OXYGEN MASKS IN THE FORWARD CABIN EJECTED. TROUBLESHOT PROBLEM TO BE A PINCHED MUX SYSTEM CABLE AT SEAT ROWS 6ABC AND 7ABC. REPLACED THE MUX CABLE AND RESET ALL OXYGEN MASKS THAT DROPPED. PERFORMED OXYGEN DROP TEST PER MM 35-20-00. PASSEJan 10, 1999 · N151SY · Doug DC1015 · Passenger Oxygen SystemSDR SCNA99001Power Supply · inopDURING A LINE MAINTENANCE CHECK, THE LEFT OVERWING EMERGENCY POWER SUPPLY FAILED TEST. REMOVED AND REPLACED THE LEFT OVERWING EMERGENCY POWER SUPPLY. OPERATIONALLY CHECKS GOOD.Jan 4, 1999 · N151SY · Doug DC1015 · Emergency LightingSDR SCNA98156Valve · failedDURING CLIMBOUT, CREW REPORTED UNABLE TO MAINTAIN CABIN ALTITUDE. AT 31,000 FEET THE ALTITUDE WARNING HORN SOUNDED AND DESCENDED TO 19,000 FEET BEFORE THE CABIN WAS CONTROLLABLE. DIVERTED AIRCRAFT TO DEN. FOUND THE NUMBER THREE PACK DUCT BLOWN OFF THE BACK Dec 31, 1998 · N151SY · Doug DC1015 · Cabin Cooling SystemSDR SCNA98542Support · corrodedDURING A HEAVY MAINTENANCE CHECK, OUT OF LIMITS CORROSION ON THE BULKHEAD FLOOR SUPPORT WAS NOTED AT FS 2007 AT THE AFT BULKHEAD RBL 60 AND LBL 23 AT CABIN FLOOR LEVEL. REMOVED AND REPLACED TEE FLOOR SUPPORT PER SRM 510000 VOLUME II (C) AND SRM 512101 VOLUME Dec 19, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98535Pin · damagedDURING A HEAVY MAINTENANCE CHECK, THE FORWARD CARGO DOOR HINGE PIN WAS FOUND TO EXHIBIT CORROSION AND DAMAGED THREADS. REPLACED HINGE PIN PER MM 523104.Dec 19, 1998 · N153SY · Doug DC1015 · Cargo/Baggage DoorsSDR SCNA98534Frame · corrodedDURING A HEAVY MAINTENANCE CHECK, THE AFT CARGO DOOR, AFT FRAME WAS FOUND TO BE CORRODED OUT OF LIMITS. INSTALLED A NEW FRAME, ANGLE AND DOOR SEAL RETAINER PER SRM 513501 AND 513301 VOLUME II.Dec 19, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98541Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1841 TO 2007 IN THE AFT LEFT INBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1841 TO 2007 PER SRM 512000 VOLUME II (C) AND SRM 512101 VOLDec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98540Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1841 TO 2007 IN THE AFT RIGHT INBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1841 TO 2007 PER SRM 512000 VOLUME II (C) AND SRM 512101 VODec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98539Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1841 TO 2007 IN THE AFT RIGHT INBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1841 TO 2007 PER SRM 512000 VOLUME II (C) AND SRM 512101 VODec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98538Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1837 TO 2007 IN THE AFT LEFT INBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1837 TO 2007 PER SRM 512000 VOLUME II (C) AND SRM 512101 VOLDec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98537Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1841 TO 2007 IN THE AFT RIGHT OUTBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1841 TO 2007 PER SRM 510000 VOLUME II (C) AND SRM 512101 VDec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98536Support · corrodedDURING A HEAVY MAINTENANCE CHECK, A GALLEY FLOOR SUPPORT WAS FOUND CORRODED OUT OF LIMITS AT FS 1841 TO 2007 IN THE AFT LEFT OUTBOARD GALLEY FLOOR. REMOVED AND REPLACED THE GALLEY FLOOR SUPPORT AT FS 1841 TO 2007 PER SRM 510000 VOLUME II (C) AND SRM 512101 VODec 18, 1998 · N153SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98147Smoke Detector · no testDURING A LINE MAINTENANCE CHECK, THE NUMBER 4 CARGO SMOKE DETECTOR DID NOT TEST. REMOVED AND REPLACED THE SMOKE DETECTOR, OPERATIONALLY CHECKED GOOD.Dec 4, 1998 · N154SY · Doug DC1015 · Smoke DetectionSDR SCNA98127Engine · failedDURING THE TAKEOFF ROLL, A LOUD BANG WAS HEARD ACCOMPANIED BY HEAVY VIBRATION OF UNKNOWN ORIGIN. TAKEOFF WAS ABORTED AT 125 KNOTS. DURING A BORESCOPE INSPECTION OF THE NUMBER THREE ENGINE METAL WAS FOUND IN THE TAILPIPE.Oct 16, 1998 · N153SY · Doug DC1015 · Engine (Turbine/Turboprop)SDR SCNA98122Wall · delaminatedDURING A MAINTENANCE CHECK, THE CENTER WALL BETWEEN THE P LIFT AND C LIFT WAS FOUND TO BE DELAMINATED. REMOVED AND REPLACED THE DAMAGED SECTION OF HONEYCOMB. FABRICATED AND INSTALLED A DOUBLER IAW MDC-10 SRM 517100.Oct 8, 1998 · N151SY · Doug DC1015 · Buffet/GalleysSDR SCNA98123Intercostal · corrodedDURING A MAINTENANCE CHECK AN INTERCOSTAL THAT RUNS OUTBOARD TO THE RIGHT OF THE P LIFT WAS FOUND CORRODED. REMOVED CORRODED INTERCOSTAL AND FABRICATED A NEW SECTION OF INTERCOSTAL. TREATED AND PRIMED AND INSTALLED IAW SRM 537000.Oct 7, 1998 · N151SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98112Slide · failed testDURING A LINE MAINTENANCE CHECK, THE R3 DOOR SLIDE PRESS TO TEST LIGHT WAS CONTINUOUSLY ILLUMINATED. FOUND SLIDE PRESSURE TO BE LOW AND REMOVED AND REPLACED THE EMERGENCY SLIDE IAW MM 256101. SLIDE PACK PRESSURE INDICATOR TESTS NORMAL.Sep 27, 1998 · N151SY · Doug DC1015 · Escape SlideSDR SCNA98091Power Supply · inoperativeDURING A LINE MAINTENANCE CHECK, THE MID CABIN EMERGENCY LIGHTING POWER SUPPLY FAILED SELF TEST. REMOVED AND REPLACED MID CABIN EMERGENCY LIGHTING (OVERHEAD) POWER SUPPLY AND BATTERY. EMERGENCY LIGHTING BITE TESTS GOOD AND OPERATIONALLY CHECKS NORMAL.Aug 14, 1998 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA98083Wire · brokenDURING A LINE MAINTENANCE CHECK, THE MID CABIN RIGHT SIDE EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. FOUND A BROKEN WIRE. WIRE REPAIRED AND LIGHTS OPERATIONALLY CHECK GOOD IN ACCORDANCE WITH 3300.Jul 29, 1998 · N151SY · Doug DC1015 · Light System WiringSDR SCNA98080Tire · failedCREW WAS INFORMED AFTER DEPARTURE THAT THE LEFT OUTBOARD (2) MAIN TIRE FAILED. REMOVED AND REPLACED THE NUMBER ONE, TWO AND SIX MAIN WHEEL ASSEMBLIES IN ACCORDANCE WITH MAINTENANCE MANUAL 324101. ALSO, REMOVED AND REPLACED THE NUMBER TWO BRAKE ASSEMBLY IN ACJul 27, 1998 · N152SY · Doug DC1015 · TireSDR SCNA98079Battery · dischargedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY LIGHT TEST FROM THE COCKPIT FAILS TEST. REMOVED AND REPLACED BOTH BATTERY CHARGER UNIT AND BATTERY IN AFT POSITION. SYSTEM OPERATIONALLY CHECKS NORMAL.Jul 23, 1998 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA98533Spar Cap · crackedDURING A HEAVY MAINTENANCE CHECK, THE LEFT WING REAR SPAR CAP SPLICE WAS FOUND TO EXHIBIT A 2 INCH CRACK AT STA XORS 415.00. REMOVED AND REPLACED THE SPAR TANG AFT AT STA XORS 415.00 AT THE LEFT REAR SPAR PER SRM 513301.Jul 21, 1998 · N153SY · Doug DC1015 · Wing SparSDR SCNA98532Fitting · corrodedDURING HEAVY CHECK, DEEP PITTING CORROSION WAS DISCOVERED ON THE FRONT SPAR, ON THE LEFT WING, FOOTSTOOL FITTING ATTACH HOLES NR 4 AND NR 6 (AROUND HOLES ON FORWARD FACE). REPAIRED PER BCAG FAX DATED 6/30/98, ACTION NR 373025 AND DWGS SBX SBA 98 0170TR, 0177Jul 21, 1998 · N152SY · Doug DC1015 · Wing Miscellaneous StructureSDR SCNA98531Light · inoperativeDURING HEAVY CHECK, THE EMERGENCY EXIT LIGHTING AT AFT A ZONE AND FWD B ZONE ARE FOUND TO BE INOPERATIVE. THE FEEDS DO NOT HAVE POWER. REMOVED AND REPLACED TWO EEL BATTERIES, TWO DIODES, AND TWO EEL FEEDS. OPERATIONAL CHECK GOOD PER MM 335300 (SUPPLEMENTAL Jul 21, 1998 · N152SY · Doug DC1015 · Emergency LightingSDR SCNA98530Tip · dentedDURING HEAVY CHECK, THE LEFT WING TIP WAS FOUND TO HAVE SEVEN DENTS, ALL LOCATED AT THE RIBS, ALL AT A VERTICLE LENGTH OF 1 AND A DEPTH OF .075 TO .020 ALL ARE SMOOTH WITHOUT CRACKS. REMOVED AND REPAIRED LEFT AND WINGTIP IAW SRM 571000 FIG 39, REINSTALLED Jul 18, 1998 · N152SY · Doug DC1015 · Wing Miscellaneous StructureSDR SCNA98529Fitting · wornDURING HEAVY CHECK, THE LEFT WING PYLON SUPORT FITTING (FOOTSTOOL) WAS FOUND TO HAVE TWO EACH WEAR MARKS APPROXIMATELY 1.5 AND AFT OF THE LEADING EDGE AND IS 5 LONG AND APPROXIMATELY .002 DEEP. THE SECOND MARK IS AT THE AFT END OF THE HOLE RUNNING 360 DEG ARJul 18, 1998 · N152SY · Doug DC1015 · Nacelle/Pylon, Attach FittingsSDR SCNA98078Battery Pack · dischargedDURING EMERGENCY LIGHT SELF TEST IN THE COCKPIT THE AFT EMERGENCY LIGHTS POWER SUPPLY FAILS. REMOVED AND REPLACED THE AFT CABIN EMERGENCY LIGHTS POWER SUPPLY AND BATTERY PACK PER MAINTENANCE MANUAL 332301, OPERATIONALLY CHECKS GOOD.Jul 18, 1998 · N153SY · Doug DC1015 · Emergency LightingSDR SCNA98528Doors · failed testDURING HEAVY CHECK, THE PASSENGER OXYGEN SYSTEM WAS FUNCTIONALLY TESTED AND SEVERAL COMPARTMENT DOORS DID NOT OPEN. REPAIRS TO WIRING AND RESET CBU SEB PERFORMED, OXYGEN DROP PER MM 352000, OPS CHECKS GOOD.Jul 15, 1998 · N152SY · Doug DC1015 · Passenger Oxygen SystemSDR SCNA98527Power Supply · inoperativeDURING HEAVY CHECK, THE B-ZONE OVERHEAD EMERGENCY LIGHTS WERE FOUND TO BE INOP. A NEW POWER SUPPLY WAS INSTALLED ABOVE THE L1 DOOR AND OPERTAION CHECK IS GOOD.Jul 15, 1998 · N152SY · Doug DC1015 · Emergency LightingSDR SCNA98073Proximity Sensor · inoperativeDURING CLIMB, THE RED NOSE GEAR LIGHT CAME ON. PERFORMED COM CHECKLIST WITH ALL GEAR DOWN INDICATIONS NORMAL. DIVERTED TO MIA. FOUND TARGET ON DOWNLOCK PROXIMITY SENSOR OUT OF ADJUSTMENT. ADJUSTED DOWN LOCK SENSORS IN ACCORDANCE WITH MAINTENANCE MANUAL 326Jul 14, 1998 · N153SY · Doug DC1015 · Landing Gear Position and WarningSDR SCNA98525Web · wornDURING HEAVY CHECK, THE NUMBER 1 PYLON LEFT HAND SIDE INTERNAL STATION YN187 PYLON WEB LOWER CAP WAS FOUND WORN TO A KNIFE EDGE, FROM CHAFING AGAINST THE CABLE HOUSING VISIBLE THROUGH PANEL 437AL. ADJUSTED BRACKET AND REINSTALLED PER SRM 513101, REPAIRED IAWJul 10, 1998 · N152SY · Doug DC1015 · Nacelle/Pylon StructureSDR SCNA98524Chord · crackedDURING HEAVY CHECK, THE RIGHT HAND INBOARD ACTUATOR SUPPORT STRUCTURES UPPER 'T' CHORD WAS FOUND TO BE CRACKED AT STATION XE103. REMOVED DAMAGED AREA AND REPAIRED IAW DWG SBX SBA 98 0124TR, SBX SBA 98 0140TR AND ROD SKETCH 980611010 AND APPROVED BY 8110 3 DAJul 10, 1998 · N152SY · Doug DC1015 · Elevator StructureSDR SCNA98523Channel · corrodedDURING HEAVY CHECK, THE FORWARD INBOARD ATTACH POINT FOR THE G7 GALLEY WAS FOUND TO HAVE CORROSION ON THE FLOOR CHANNEL. THE GALLEY FLOOR SUPPORT WAS CORRODED BEYOND LIMITS REPAIR SUPPORT AND SPLICE WERE FABRICATED IAW SRM 537000 FIGURE13 AND TREATED IAW SRM Jul 10, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98522Support · corrodedDURING HEAVY CHECK, LEVEL 2 CORROSION STATION 1908 RBL56 ON CABIN FLOOR SUPPORT WAS DISCOVERED. CUT OUT CORRODED AREA AND FABRICATED FLOOR SUPPORT AND SPLICE ANGLES PER SRM 537000 FIG13, AND 530001 TREATED PARTS PER SRM 512101 AND INSTALLED COMPLETE PER SRM Jul 10, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98521Support · corrodedDURING HEAVY CHECK, STA 1947 TO 2007 AT RBL 26 COROSION FOUND ON FLANGE STRUCTURE. GALLEY FLOOR SUPPORT CORRODED BEYOND LIMITS, FABRICATED REPAIR SUPPORT AND SPLICE IAW SRM 537000 FIG13. TREATED IAW SRM 512101 AND INSTALLED PER SRM 513101.Jul 10, 1998 · N152SY · Doug DC1015 · Fuselage Internal Mounting StructureSDR SCNA98520Support · corrosionDURING HEAVY CHECK, STA 1947 TO 2007 AT RBL 55 AND RBL 60 COROSION FOUND ON FLANGE STRUCTURE. CUT OUT CORRODED AREA AND FABRICATED FLOOR SUPPORT AND SPLICE ANGLES PER SRM 537000 FIGURE 13 AND 530001, TREATED PARTS PER SRM 512101 AND INSTALLED COMPLETE PER SRMJul 10, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98519Seat Track · corrosionDURING HEAVY CHECK, STA 1965 RBL77 AT LAV MOUNT AREA CORROSION FOUND ON TRACK LEVEL 2. FABRICATED SEAT TRACK IAW SRM 512101 AND INSTALLED IAW SEAT TRACK IAW SRM 513000 FIG 1.Jul 10, 1998 · N152SY · Doug DC1015 · Fuselage, Seat/Cargo Attach FittingsSDR SCNA98518Seat Track · corrosionDURING HEAVY CHECK, STA 1912 RBL90 AT LAV MOUNT AREA CORROSION FOUND ON TRACK LEVEL 2. FABRICATED SEAT TRACK IAW SRM 512101 AND INSTALLED IAW SEAT TRACK IAW SRM 513000 FIG1.Jul 10, 1998 · N152SY · Doug DC1015 · Fuselage, Seat/Cargo Attach FittingsSDR SCNA98515Supports · corrosionDURING HEAVY CHECK, THE FLOORBOARD SUPPORT AT STATION 1908 RBL56 ON THE CABIN FLOOR SUPPORT HAS LEVEL TWO CORROSION. CUT-OUT CORRODED AREA AND FABRICATED FLOOR SUPPORT AND SPLICE ANGLES PER SRM 537000 FIGURE 13 AND 530001. TREATED PARTS PER SRM 512101 AND INJul 6, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98514Supports · corrosionDURING HEAVY CHECK, THE FLOORBOARD SUPPORT AT STATION 1908 LEADING EDGE OF THE RIGHT HAND AFT LAV HAS LIGHT CORROSION THROUGH OUT RIGHT SUPPORT. MATERIAL VERIFIED FOR FLOORBOARD SUPPORT STRUSION. FABRICATED ONE EACH FLOORBOARD PER SRM 530001 FIG 1, TREATED PJul 6, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98513Channel · corrodedDURING HEAVY CHECK, LEVEL TWO CORROSION WAS DISCOVERED ON THE HAT CHANNEL AT STATION 1912 TO 1973 IN THREE SPOTS. REMOVED AND REPLACED DAMAGED HAT CHANNEL IAW SRM 530001, ALODINED AND PRIMED PER SRM 512101, TOP COATED PER SRM 512102.Jul 6, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98512Supports · corrosionDURING HEAVY CHECK, LEVEL TWO CORROSION WAS DISCOVERED AT STA 1887 LBL27 TO RBL80 ON CABIN FLOOR SUPPORTS. REMOVED FIVE EACH FLOOR SUPPORTS, FABRICATED FIVE EACH FLOOR SUPPORTS PER SRM 530001 AT STATION 1887 FROM LBL27 TO RBL80. TREATED AND PRIMED PER SRM 51Jul 6, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98511Spar · crackedDURING HEAVY CHECK, CRACKS WERE DISCOVERED IN THE RIGHT HAND HORIZONTAL SPAR HAS A .5 INCH CRACK AT STATION XSFS 86/XE 28.42. LOCATED AND DRILLED ANGLES, DOUBLER, SHIM AND 'T' CHORD PER SRM 552000, ALODINED AND TREATED PER SRM 512101. INSTALLED ANGLES, DOUBJul 6, 1998 · N152SY · Doug DC1015 · Elevator, Spar/RibSDR SCNA98510Frame · crackedDURING HEAVY CHECK, CRACKS IN THE R3 DOOR FRAME BOX CUTOUT WERE DISCOVERED AT THE FLOOR LEVEL AT STATION 1256, INBOARD OF THE ARM SHAFT AT OPPOSITE CORNERS, (2 CRACKS). MATERIAL VERIFIED IAW SRM 535000 FIGURE 19 SHEET 1. DOUBLER FABRICATED PER SRM 53-50-00Jul 6, 1998 · N152SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA98517Battery Pack · dischargedDURING A HEAVY MAINTENANCE CHECK, THE OVERWING EMERGENCY EXIT LIGHT BATTERY PACK WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE OVERWING BATTERY PACK AT THE L3 LOCATION. OPERATIONALLY CHECKS GOOD PER MAINTENANCE MANUAL 335101.Jun 29, 1998 · N152SY · Doug DC1015 · Emergency LightingSDR SCNA98516Battery Pack · dischargedDURING A HEAVY MAINTENANCE CHECK, THE MID CABIN EMERGENCY EXIT LIGHT BATTERY PACK WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE MID CABIN BATTERY PACK AT THE L2 LOCATION. OPERATIONALLY CHECKS GOOD PER MAINTENANCE MANUAL 335101.Jun 29, 1998 · N152SY · Doug DC1015 · Emergency Lighting
Back to Mcdonnell Douglas DC-10-15