Mcdonnell Douglas DC-9-51

Service difficulty reports · 4,581

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC951'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR NWAA093639863Battery · dischargedDURING LINE CHECK MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Oct 19, 2009 · N772NC · Doug DC951 · Emergency LightingSDR NWAA093559872Battery · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE TAIL CONE WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Oct 12, 2009 · N781NC · Doug DC951 · Emergency LightingSDR NWAA093509874Battery · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 AND THE LEFT SIDE EMERGENCY EXIT SIGN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Oct 8, 2009 · N783NC · Doug DC951 · Emergency LightingSDR NWAA093439865Fuse · blownDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE 1ST FOUR ROWS OF COACH SEATS IN THE CABIN HAD FAILED. MAINTENANCE REPLACED THE FUSE IN THE EXIT DOOR POWER PACK. OPERATIONAL CHECK WAS GOOD.Oct 3, 2009 · N774NC · Doug DC951 · Emergency LightingSDR NWAA093429852Power Supply · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.Oct 3, 2009 · N761NC · Doug DC951 · Emergency LightingSDR NWAA093379875Charger · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING IN THE COCKPIT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK & CHARGER AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Oct 1, 2009 · N784NC · Doug DC951 · Emergency LightingSDR NWAA093339855Charger · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-8 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER EMERGENCY LIGHT ASSEMBLY AND THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Sep 23, 2009 · N764NC · Doug DC951 · Emergency LightingSDR NWAA093209875Power Supply · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT AND THE AFT EMERGENCY HANDLE LIGHT WERE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.Sep 11, 2009 · N784NC · Doug DC951 · Emergency LightingSDR NWAA093189874Seal · blownDURING CLIMB AT APPROX 800FT ENGINE NR 2 FLAMED OUT. FLIGHT CREW RETURNED AIRCRAFT TO DEPARTURE AIRPORT PERFORMING AN UNEVENTFUL LANDING. MAINTENANCE FOUND BLOWN SEALS AT THE FUEL IN LINE TO THE P&D VALVE.Sep 9, 2009 · N783NC · Doug DC951 · Engine Fuel DistributionSDR NWAA093119867Battery · dischargedDURING LINK CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 13-17 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Sep 3, 2009 · N776NC · Doug DC951 · Emergency LightingSDR NWAA093069870Power Supply · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.Sep 1, 2009 · N779NC · Doug DC951 · Emergency LightingSDR NWAA093039873Slide · failedCLEANERS RELEASED THE TAIL CONE EXPECTING ACCESS TO VENTRAL STAIRS. THE TAIL CONE DROPPED BUT THE EMERGENCY EVACUATION SLIDE DID NOT DEPLOY. TEMPORARY REPAIRS MADE TO THE TAIL CONE AND THE AIRCRAFT WAS FERRIED FROM MCI TO MSP. THE TAIL CONE AND THE EVACUATIAug 29, 2009 · N782NC · Doug DC951 · Escape SlideSDR DALA12015740875Skin · dentedDENT TO FUSELAGE SKIN.Aug 28, 2009 · N784NC · Doug DC951 · Fuselage Main, Plate/SkinSDR NWAA093049856Socket · dirtyDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WERE INOPERATIVE. MAINTENANCE FOUND THE STAIRS LIGHT SOCKETS WERE COMPROMISED AND CLEANED THEM. SUBSEQUENT FUNCTIONAL CHECKS WERE GOOD.Aug 28, 2009 · N765NC · Doug DC951 · Emergency LightingSDR NWAA093029875Pressure System · malfunctionedLEAVING FL300, THE RED "CABIN PRESS" WARNING LIGHT ILLUMINATED WITH THE CABIN ALTITUDE BETWEEN 12,000 AND 13,000 FT. FLIGHT WAS ALREADY CLEARED TO FL120 BUT CAPTAIN DIRECTED AN IMMEDIATE TO 10,000 AND EXECUTED THE RED BORDERED CHECK LIST. THE MASKS DID NOT DAug 19, 2009 · N784NC · Doug DC951 · Cabin Pressure Control SystemSDR NWAA092839883Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT TWO OF THE THREE EMERGENCY PATHWAY LIGHTS FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRING, REPLACED THE BATTERIES IN THE POWER SUPPLY, AND FUNCTIONALLY CHECKED THE SYSTEM.Aug 10, 2009 · N671MC · Doug DC951 · Light System WiringSDR NWAA092849883Battery · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY SIDEWALL LIGHTING IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Aug 10, 2009 · N671MC · Doug DC951 · Emergency LightingSDR NWAA092799864Battery Pack · dischargedDURING THE PREFLIGHT CHECK, IT WAS DISCOVERED THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT AND ALL OF THE OVERWING EXITS WERE INOPERATIVE. MAINTENANCE REPLACED EACH OF THE APPLICABLE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPAug 7, 2009 · N773NC · Doug DC951 · Emergency LightingSDR NWAA092789864Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Aug 7, 2009 · N773NC · Doug DC951 · Emergency LightingSDR NWAA092779864Battery Pack · dischargedDURING PREFLIGHT CHECK, IT WAS DISCOVERED THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN AND THE COACH SECTION OF THE CABIN HAD ALL FAILED. MAINTENANCE REPLACED ALL OF THE APPLICABLE BATTERY PACKS AND THE LIGHTS RETURNED TO AN OPEAug 7, 2009 · Doug DC951 · Emergency LightingSDR NWAA092609862Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND REPAIRED A BROKEN GROUND WIRE. THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Jul 25, 2009 · N771NC · Doug DC951 · Light System WiringSDR NWAA092569860Battery Pack · dischargedDURING LINE CHECK MAINTENANCE FOUND THAT THE RIGHT SIDE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHT. RETURNED TO AN OPERATIONAL CONDITION.Jul 20, 2009 · N769NC · Doug DC951 · Emergency LightingSDR DALA12015760875Skin · damagedFUSELAGE SKIN CRACKED AND DENTED AT BS 292 BETWEEN LONGERONS 22L & 23L. DAMAGED AREA REPAIRED IAW SRM 53-04-00, FIG 12B.Jul 17, 2009 · N784NC · Doug DC951 · Fuselage Main, Plate/SkinSDR NWAA092499885Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPAIRED THE WIRING AND FUNCTIONALLY CHECKED THE SYSTEM.Jul 13, 2009 · N401EA · Doug DC951 · Light System WiringSDR NWAA092389860Battery Pack · dischargedDURING LINE CHECK MAINTENANCE FOUND THAT THE RIGHT EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Jul 5, 2009 · N769NC · Doug DC951 · Emergency LightingSDR NWAA092379852Battery · dischargedDURING LINE CHECK MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Jul 5, 2009 · N761NC · Doug DC951 · Emergency LightingSDR NWAA092309867Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 22-26 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Jun 25, 2009 · N776NC · Doug DC951 · Emergency LightingSDR NWAA092349881Rib · crackedDURING "M" CHECK FOUND CRACK IN RT WING LEADING EDGE RIB FASTENER HOLE AT STA XCW 124. REPAIRED PER EA 98-215902.Jun 17, 2009 · N676MC · Doug DC951 · Wing, Rib/BulkheadSDR NWAA092219865Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5/8 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED FUSE AND THE OPERATIONAL CHECK WAS GOOD.Jun 16, 2009 · N774NC · Doug DC951 · Emergency LightingSDR NWAA2159853Rib · crackedDURING "L" CHECK FOUND CRACK IN LT WING LEADING EDGE RIB AT STA 134.921. REPAIRED PER EA 98-215904.Jun 10, 2009 · N762NC · Doug DC951 · Wing, Rib/BulkheadSDR NWAA092099862Wire · corrodedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE FOUND CORRODED WIRES IN THE LIGHT ASSEMBLY AND REPLACED THOSE WIRES. THE FUNCTIONAL CHECK OF THE SYSTEM WAS SATISFACTORY.Jun 8, 2009 · N771NC · Doug DC951 · Light System WiringSDR NWAA091909858Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLIES, BULBS, BATTERIES AND THEN PERFORMED A SATISFACTORY FUNCTIONAL CHECK OF THEM.May 30, 2009 · N767NC · Doug DC951 · Emergency LightingSDR NWAA092119874Skin · damagedDURING GROUND OPERATIONS LT FUSELAGE SKIN WAS DAMAGED BETWEEN BS 446-BS 503 L25L AND L28L. REPAIRED PER EA 98-215559.May 27, 2009 · N783NC · Doug DC951 · Fuselage Main, Plate/SkinSDR NWAA 091709885Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTS FOR THE CATWALK IN THE TAIL COMPARTMENT WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.May 17, 2009 · N401EA · Doug DC951 · Emergency LightingSDR NWAA 091689865Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPAIRED THE WIRING AND FUNCTIONALLY CHECKED THE SYSTEM.May 14, 2009 · N774NC · Doug DC951 · Emergency LightingSDR NWAA091749884Floor Panel · debondedDURING "H" CHECK, FOUND FLOOR PANEL NR 17 HAD 10 SUPPORT CHANNELS DISBONDED AT END ATTACH POINTS. REPAIRED PER EA 98-214550.May 11, 2009 · N677MC · Doug DC951 · Fuselage Floor PanelSDR NWAA 091589858Battery Pack · inoperativeESCAPE PATH EMERGENCY LIGHTS QUICKLY DIMES OUT IN FIRST CLASS SEATS, AND ROWS 14 - 18 INOPERATIVE. REPLACED DOOR 1R BATTERY PACK, AND REPLACED LIGHT ASSEMBLY AT SEAT 1C.May 10, 2009 · N767NC · Doug DC951 · Emergency LightingSDR NWAA 091679868Fuse · failedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 913 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED FUSE AND THE OPERATIONAL CHECK WAS GOOD.May 8, 2009 · N777NC · Doug DC951 · Emergency LightingSDR NWAA091969884Floor Support · crackedDURING "H" CHECK FOUND FLOOR PANEL NR 18 HAD 4 SUPPORT CHANNELS CRACKED. REPAIRED PER EA 98-214548.May 6, 2009 · N677MC · Doug DC951 · Fuselage Miscellaneous StructureSDR NWAA091959884Rib · crackedDURING "H" CHECK FOUND CRACK IN RT WING LEADING EDGE RIB AT STATION XIS 134. REPAIRED PER EA 98-214545.May 5, 2009 · N677MC · Doug DC951 · Wing, Rib/BulkheadSDR NWAA 091349861Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE LEFT OVERWING EMERGENCY EXIT SIGN WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.Apr 25, 2009 · N770NC · Doug DC951 · Emergency LightingSDR NWAA 091339857Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.Apr 23, 2009 · N766NC · Doug DC951 · Emergency LightingSDR NWAA 091249883Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5/8 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND BATTERY PACKS AT THE FWD RT OVERWING EXIT SIGN AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Apr 17, 2009 · N671MC · Doug DC951 · Emergency LightingSDR NWAA091299995Doubler · crackedFLIGHT ATTENDANT LOG BOOK INDICATED LEFT OVERWING EXIT HANDLE SLOWLY POPS OUT. MAINTENANCE REMOVED LEFT OVERWING EXIT DOOR AND FOUND LOWER AIRCRAFT FRAME ASSEMBLY DOUBLER CRACKED AND WORN. ALSO, FOUND UPPER AIRCRAFT FRAME AND RECESSED RIVET HEAD WORN AT THE Apr 14, 2009 · N8978E · Doug DC951 · Fuselage Main, FrameSDR NWAA09949874Power Supply · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY FLOOD LIGHT FOR THE AFT EVACUATION SLIDE WAS NOT FUNCTIONAL. MX REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM. (K)Mar 25, 2009 · N783NC · Doug DC951 · Emergency LightingSDR NWAA09819884Battery · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-16 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERIES. OPS CHECK WAS GOOD. (K)Mar 23, 2009 · N677MC · Doug DC951 · Emergency LightingSDR NWAA999882Floor Panel · delaminatedDURING M-CHECK FOUND DELAMINATION ON MAIN CABIN FLOOR PANEL NR 18 HAT CHANNELS. REPAIRED IAW EA 98-214533. (K)Mar 22, 2009 · N760MC · Doug DC951 · Fuselage Floor PanelSDR NWAA09939875Socket · inoperativeDURING LINE CHECK, MX FOUND THAT THE RT OVERWING EMERGENCY EXIT SIGNS WAS INOPERATIVE. MX REPLACED THE LIGHT SOCKET ASSY AND FUNCTIONALLY CHECKED IT. (K)Mar 22, 2009 · N784NC · Doug DC951 · Emergency LightingSDR NWAA09809868Light · shortedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-8 OF THE CABIN WERE INOPERATIVE. MX FOUND THE LIGHT ASSY AT ROW 6 WAS SHORTING, THEREBY BLOWING THE FUSE. MX REPLACED THE LIGHT ASSY AND PERFORMED A SATISFACTORY FUNCTIONAL CHECK. (K)Mar 21, 2009 · N777NC · Doug DC951 · Emergency LightingSDR NWAA09789865Fuse · failedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN AND THE RT FRONT DOOR EXIT SIGN HAD ALL FAILED. MX REPLACED THE ASSOCIATED FUSE IN THE PERTINENT CIRCUIT BOARD. OPS CHECK WAS GOOD. (K)Mar 17, 2009 · N774NC · Doug DC951 · Emergency Lighting
Back to Mcdonnell Douglas DC-9-51