SDR NWAA09729884Fuse · failedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-14 AND THE LT FWD OVERWING EMERGENCY EXIT SIGN WERE INOPERATIVE. MX INSTALLED NEW BATTERIES FIRST BUT WHEN THAT DID NOT CORRECT THE PROBLEM THEY REPLACED THE ASSOCIATED FUSE IN THE POWESDR NWAA09759869Controller · inoperativeDURING CRUISE FLIGHT, THE CREW NOTICED AN UNCOMMANDED CLIMB IN CABIN ALTITUDE. THE EMERGENCY PRESSURE LOSS CHECKLIST WAS ACCOMPLISHED BUT CABIN PRESSURE WAS NOT RESTORED. A RAPID DESCENT WAS MADE TO A LOWER ALTITUDE AND THE FLIGHT DIVERTED. COM WAS FOLLOWEDSDR NWAA09599868Power Supply · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-8 OF THE CABIN GO DIM AFTER ABOUT 3 SECONDS. MX REPLACED THE POWER SUPPLY FOR THE FWD OVERWING EXIT SIGN AND THE POWER SUPPLY AT ROW 14, LWR RT SIDE. THE LIGHTS RETURNED TO AN OPERATIOSDR NWAA09549886Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY FLOOD LIGHT FOR THE AFT EVACUATION SLIDE AND THE TAIL CONE EGRESS LIGHTS WERE NOT FUNCTIONAL. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (K)SDR NWAA09459870Limiter · rupturedCREW REPORTED LOSING THE LT HYDR SYS FLUID QUANTITY AND PRESSURE DURING TAXI OUT FOR TAKEOFF. COM PROCEDURES WERE COMPLIED WITH AND THE ACFT RETURNED TO THE GATE WITHOUT ANY FURTHER PROBLEM. MX FOUND HYDR QUANTITY LIMITER IN THE LT WHEEL WELL HAD RUPTURED. SDR NWAA09449856Unknown · leakingDURING ROTATION AND CLIMB ENGINE NR1 FUEL FLOW WAS ERRATIC AND EPR DROPPED ABOUT 10 PERCENT. ADVANCED THROTTLE TO MATCH ENGINE NR2 BUT EPR DROPPED AGAIN TO 1.6 AND WOULD NOT RESPOND TO HIGHER THROTTLE SETTINGS. FLIGHT CREW RETURNED ACFT TO DEPARTURE AIRPORT.SDR NWAA09399865Light · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MX REPLACED THE EXIT ASSY AT DOOR NR 2 OPS RETURNED TO NORMAL. (K)SDR NWAA09389874Wire · shortedDURING LINE CHECK, MX FOUND THAT BOTH OF THE EXTERIOR EMERGENCY OVERWING EMERGENCY FLOOD LIGHTS WERE INOPERATIVE. MX FOUND A SHORTED WIRE AT THE OVERWING EMERGENCY LIGHT AND REPAIRED IT. ALSO, REPLACED BATTERY PACK B5-49. (K)SDR NWAA09269874Floorbeam · crackedDURING LINE CHECK FOUND WEAK SPOT IN FLOOR BETWEEN SEAT 4B AND 4C. FOUND CRACK IN THE FLOOR SUPPORT T-CAP AT BS 427. REPAIRED PER EA 98-215295. (K)SDR NWAA09229858Power Supply · inoperativeDURING LINE CHECK, MX FOUND THE THE FWD OVERWING EMERGENCY EXIT SIGNS WERE INOPERATIVE. MX REPLACED THE PWR SUPPLY AND THE LIGHS RETURNED TO AN OPERATIONAL CONDITION. (K)SDR NWAA0939863Battery Pack · dischargedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX REPLACED BATTERY. (K)SDR NWAA085729858Relay · inoperativeDURING LINE CHECK, MX FOUND THAT THE RT EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MX REPLACED THE PERTINENT POWER RELAY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (K)SDR NWAA085739863Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY ESCAPE PATH LIGHTS FOR THE TAIL COMPARTMENT WERE INOPERATIVE. MX REPLACED THE TAIL COMPARTMENT BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (K)SDR NWAA085709866Battery Pack · dischargedDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE CABIN HAD FAILED. MX REPLACED THE BATTERY PACK AND THE LIGHTS WERE RETURNED TO AN OP CONDITION.SDR NWAA085639865Battery Pack · failedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MX REPLACED 3 BATTERY PACKS AND 1 POWER SUPPLY TO GET THE LIGHTS TO RETURN TO AN OP CONDITION.SDR NWAA085329852Wire · damagedDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 14-18 OF THE CABIN WERE INOPERATIVE. MX REPAIRED THE WIRING AND FUNCTIONALLY CHECKED THE SYSTEM.SDR NWAA085319852Battery Pack · inoperativeDURING LINE CHECK BOTH OF THE FORWARD OVERWING EMERGENCY EXIT SIGNS WERE FOUND TO BE INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA085259870Battery Pack · inoperativeDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPS CONDITION.SDR NWAA085079858Battery · dischargedDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-13 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA085059852Floor Panel · crackedDURING H CHECK FOUND CRACK ON THE EDGE OF FLOOR PANEL NR 18 AND 4 STIFFENERS. REPAIRED PER EA 98-213662.SDR NWAA085069852Stiffener · crackedDURING H CHECK FOUND CRACKS IN 2 STIFFENERS FOR FLOOR PANEL NR 28. REPAIRED PER EA 214491.SDR NWAA084979862Connector · looseDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 14-18 OF THE CABIN WERE INOPERATIVE. MX CORRECTED A LOOSE CONNECTION AND THEN OPS CHECKED THE SYSTEM.SDR NWAA085039870Battery Pack · dischargedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA084959867Connector · looseDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FROM ROWS 22 AND AFT WERE INOPERATIVE. MX FOUND AND CORRECTED A LOOSE CONNECTION AND THEN OPS CHECKED THE SYSTEM.SDR NWAA084849853Battery Pack · inoperativeDURING LINE CHECK MX FOUND THAT THE RT SIDE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OP CONDITION.SDR NWAA084859873Connector · damagedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 19-22 OF THE CABIN AND IN THE TAIL COMPARTMENT WERE INOPERATIVE. MX REPAIRED THE CONNECTOR FOR THE WIRE HARNESS AT THE SIDEWALL AND FUNCTIONALLY CHECKED THE SYSTEM.SDR NWAA084839853Wire · brokenDURING LINE CHECK, MX FOUND THAT THE LAST EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MX FOUND A BROKEN WIRE AND REPAIRED IT.SDR NWAA084829853Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MX REPLACED THE BATTERIES. OPS CHECK WAS GOOD.SDR NWAA084769881Battery Pack · dischargedDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE OR TOO DIM TO BE FUNCTIONAL. MX CHARGED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OP CONDITION.SDR NWAA084749880Battery · dischargedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-13 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERIES. OPS CHECK WAS GOOD.SDR NWAA084659865Battery Pack · inoperativeDURING LINE CHECK MX FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MX R&R THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPS CONDITION.SDR NWAA084299861Battery Pack · inoperativeDURING LINE CHECK, MAINT FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINT REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (K)SDR NWAA085089871Battery Pack · dischargedDURING LINE CHECK MX FOUND THAT BOTH OF THE EXTERIOR EMERGENCY LIGHTS WERE INOPERATIVE. MX REPLACED THE BATTERY PACK AND BOTH OF THE LIGHTS RETURNED TO AN OP CONDITION.SDR NWAA084559869Power Supply · dischargedDURING LINE CHECK, MX FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MX REPLACED THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPS CONDITION.SDR NWAA085029881O-Ring · leakingSHORTLY AFTER TAKEOFF FLIGHT ATTENDANT REPORTED STRONG FUEL ODOR IN CABIN. A SLIGHT FUEL ODOR WAS NOTICED IN THE COCKPIT. FLIGHT CREW LANDED AT DESTINATION. MX NOTICED APU INTAKE PLENUM WET WITH FUEL AND ALSO A FUEL LEAK AT THE APU FUEL HEATER. THE APU ANDSDR NWAA084499851Stiffener · crackedDURING H CHECK FOUND CRACK IN OTBD END OF UPPER AFT PRESSURE BULKHEAD HORIZONTAL STIFFENER. REPAIRED PER EA 98-213643.SDR DALA1151039885Skin · dentedFUSELAGE EXTERIOR STA 237 BETWEEN L17L AND L18L SKIN APPROX HAS L-2 INCHES W-1 INCH AND DENT=.060 IN A PREVIOUS REPAIR. REMOVED EXISTING REPAIR 4 SQ , FABBED & INSTALLED FILLER &DOUBLER IAW DC-9 SRM 53-04 FIG 12B. COMPLETED INITIAL. REPETITIVE: TERMINATED: 2SDR DALA1151709885Skin · damagedFUSELAGE EXT STA 120 BETWEEN 17L AND 18L SKIN PROTRUDING CAN'T MEET REQ OF TRM 53-30-8 INTERNAL INSP REQ BY 4500 FH. HFEC INSP REQ AT "L" CHECK INTERVALS. ACCOMPL CLOSE VISUAL INSP OF REPAIR AREA PRIOR TO 3000 FLT CYCLES AFTER SECT 1 AND REPEAT INSP EVERY 3SDR DALA1151029885Skin · dentedFWD FUSELAGE JUST FWD OF STA 239 AT LONGERON 17L SKIN HAS DENT. MEASURED DENT 1" X .026" D/X= 38. MEETS REQUIREMENTS OF DC-9 SRM 53-04 FIG 38. LESS THAN 1 INCN TO STRUCTURE CLASS III EXTERNAL DOUBLER REPAIR INSTALLED AT THIS LOCATION REF LOG PAGE 2935101 DASDR NWAA084139884Fuse · blownDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 14-18 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE ASSOCIATED FUSE. OPS CHECK WAS GOOD.SDR NWAA084109865Controller · defectiveDURING CLIMB AS THE ACFT DEPARTED MSP THE FLIGHT ATTENDANT REPORTED A BURNING SMELL THROUGHOUT THE CABIN. NO MENTION OF COM COMPLIANCE BUT THE FLIGHT CREW DID DECLARE A YELLOW EMERGENCY AND RETURNED TO AN UNEVENTFUL LANDING BACK AT MSP. PASSENGERS DEPLANED NSDR NWAA084129866Pin · pulledDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-13 OF THE CABIN WERE INOPERATIVE. INVESTIGATION REVEALED THAT A PIN HAD BEEN PULLED FROM THE WALL DISCONNECT PLUG. MX REPAIRED IT BY RE-INSERTING THE PIN. ALL CHECKS WERE GOOD.SDR NWAA084119865Battery Pack · dischargedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA083969855Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE LT SIDE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND THE LIGHT RETURNED TO AN OPERATIONAL CONDITION. (S)SDR NWAA083769862Skin · crackedDURING H-CHECK, FOUND CRACK IN FUSELAGE SKIN AT THE UPPER FORWARD CORNER OF PASSENGER ENTRY DOOR JAMB. REPAIRED PER EA 98-213637. (S)SDR NWAA083639852Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (S)SDR NWAA083629857Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE RED EMERGENCY LIGHT AT SEAT 13D IS INOPERATIVE DUE TO BROKEN WIRES IN THE OUTER SEAT TRACK. MAINTENANCE REPAIRED BROKEN WIRES AND THE LIGHT RETURNED TO AN OPERATIONAL CONDITION. (S)SDR NWAA083609853Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE AFT SECTION HAD FAILED. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (S)SDR NWAA083569853Pulley · defectiveFLIGHT RETURNED TO A SAFE LANDING AT DTW AFTER CREW DETERMINED AILERONS WERE BINDING DURING LT TURNS. CONTROL CHECK WAS NORMAL ON THE GROUND BOTH BEFORE TAKEOFF AND DURING TAXI IN AFTER RETURN. LT TURNS REQUIRED THE MOST EFFORT BUT AILERON CONTROL WAS DIFFICSDR NWAA083469874Crank Assy · wornFLIGHT RETURNED TO DTW AFTER TAKEOFF DUE TO UNRESPONSIVE OR SLOW TO RESPOND FLIGHT CONTROLS (AILERONS). CREW NOTICED 2 TO 3 INCHES OF YOKE TRAVEL BEFORE ANY FLIGHT CONTROL INPUT RESULTED IN AIRCRAFT CONTROL. PER DISPATCH REPORT MAINTENANCE CONTROL WAS CONTAC
Back to Mcdonnell Douglas DC-9-51