Mcdonnell Douglas DC-9-51
Service difficulty reports · 4,581
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1136709861Floor Panel · damagedCABIN FLOOR PNL NR 53 TWO SCREWS ARE PULLED THRU SKIN. FABRICATED TREATED AND PRIMED AND INSTALLED REPAIR DOUBLER WASHER AT FLOOR PNL NR 53 PER SRM 51-10-3 PGS 31, 32, 40, AND 42 AND SRM 53-05 PG 12 FIG 3.SDR DALA1136699866Support · cracked6C/281 MAIN PASSENGER CABIN STA 1184 RBL 22 ELEVATOR CONTROL CABLES PULLEY BRACKET MOUNT SUPPORT AFT SIDE OF PULLEY CRACKED. REMOVED SUPPORT, STOP DRILLED CRACK, NDT VERIFIED CRACKS CONTAINED. FABRICATED AND INSTALLED REPAIR PARTS FROM NR 1120665. ALL WORKSDR DALA1138679880Floorboard · corrodedFLOORBOARD 19 HAS CORROSION (DT-09). REMOVED, FABRICATED, AND INSTALLED FLOORBOARD PANEL SKIN 19 AND 2 EA U-CHANNELS AT FLOORBOARD PANEL 19 IAW DC-9 SRM 53-23-0, FIG 3, SHT 3, PG 6, AND DC-9 SRM 51-30-2, PG 24.SDR DALA1138649880Connector · brokenMAINTENANCE FOUND EMERGENCY LIGHT CONNECTOR BROKEN AT FORWARD LEFT OVERWING EXIT SIDEWALL PANEL. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT CONNECTOR. OPERATIONAL CHECK WAS GOOD.SDR DALA1136579882Battery · dischargedDURING SERVICE CHECK, MAINTENANCE FOUND THAT EMERGENCY LIGHTS DO NOT ILLUMINATE. MAINTENANCE REPLACED BATTERIES AS NEEDED PER DC-9 AMM. NEED POWER SUPPLY AT EACH LOWER EXIT SIGN BY WING HATCHES. WORK IN PROGRESS. REPLACED BATTERIES AT OVERWING EXITS. OPERSDR DALA1136499866Floor Panel · crackedMAIN PASSENGER CABIN FLOOR PANEL NR 86LT SIDE IS CRACKED 2 PLACES. CUT OUT DAMAGE SECTION 25 INCHES BY 9 INCHES. NO DEFECTS IAW NDT SPM 06-10-06. FABRICATED AND INSTALLED FILLER .020 7075-T6 AND DOUBLER .032 7075-T6 IAW ERA 491735-14. P-226 REQUIRED INSP COSDR DALA1136739880Floorboard · damagedMAIN CABIN FLOOR BOARD NR 23, ENLONGATED HOLES, (5). FABRICATED 5 DOUBLER REPAIR WASHERS IAW DC9 SRM 53-05, PG 12, FIG 3, SRM 51-60-0, FIG 1, AND INSTALLED 5 DOUBLER. REPAIR WASHERS AND PERMACEL TAPE AT MAIN CABIN FLOOR BOARD NR 23 IAW AMM DC-9-A-53-20-01-20SDR DALA1139819861Skin · gougedRT WING FIX VANE MID PANEL FWD SECTION HAS A DEEP GOUGE ON SKIN TO BARE METAL, LOOSE EYE BOLT. CUT OUT GOUGE ON SKIN, IAW SRM 51-70-2, FABBED DOUBLER AND FILLER PER SRM 51-70-2, SRM 57-03, APPLIED ALODINE PER DC9 SRM 51-10-3, PRIMER PER SRM 51-10-3, PG 31-32SDR DALA1136039866Floor Panel · crackedMAIN CABIN FLOOR PANEL NR 85 HAS CRACK INBD AFT END. CUTOUT DAMAGE 2 INCHES BY 1.25 INCHES NO DEFECTS PER NDT SPM 06-10-01. FABRICATED AND INSTALLED FILLER AND DOUBLER FROM .020 7075-T6 PO NR 1120495 IAW DC-9 SRM 53-01 FIG 4, P225. REQUIRED INSPECTION COMPLSDR DALA1136029866Channel · dentedMAIN CABIN FLOOR PANEL NR 77 HAS 5 HAT CHANNELS DISBONDED AND IEA HAS DENT. REMOVED HAT CHANNELS IAW SRM 51-10-4. LOCATED AND DRILLED HOLES IN DISBONDED HAT CHANNELS AND INSTALLED HAT CHANNELS IAW SRM 51-30-2 AS PER ENGINEERING. REQUIRED INSPECTION COMPLETESDR DALA1138489861Floor Support · crackedCABIN OVERWING STRUCTURE FLOOR SUPPORT CRACKED AT STA 775 AND X-15. REMOVED FLOOR SUPPORT ON MAIN CABIN AT STA 775 AND X-15 IAW DC9 SRM 51-30-02, FABRICATED FLOOR SUPPORT IAW DC9 SRM 53-13-3, PG 26, FIG 11. INSTALLED FLOOR SUPPORT AT STA 775 AND X-15 IAW DCSDR DALA1140299861Floor Panel · bentCABIN FLOOR PNL 79, FWD END IS BENT UP AND THERE ARE THREE MIS-DRILLED HOLES ALONG I/B AFT EDGE FABED NEW FLOOR PANEL PER DC9 SRM 53-21-0, PG 14B, 14D, SHEET 1-3, AND SRM DC9 51-30-2. TREATED AND PRIMED PER DC9 SRM 51-10-3. ASSEMBLED FLOOR PANEL BY INSTALLISDR DALA1140279861Floor Panel · corrodedCABIN FLOOR PNL HAS SURFACE CORROSION AT FWD END. REMOVED AND FABRICATED REPLACEMENT FLOOR PANEL WITH SHT 7075T6 .032, BATCH 0002057150 IAW DC9 SRM 51-01 PG 3 AND DC9 SRM 51-20-0 PG 4, AND DC9 SRM 51-30-02.SDR DALA1139719861Doubler · crackedLEFT WING REAR SPAR WEB DOUBLER O/B SIDE OF AFT DOUBLER IS CRACKED, REF: EM 5710-00028, SECTION 03 UPON FURTHER INVESTIGATION, ALL WORK TO BE COMPLIED WITH ON WORK CARD 5710-00028-08A (LEFT WING SPAR AND/OR DOUBLER TRIM REPAIR) JOB 000-0009, WO 87938350001.SDR DALA1139639861Floor Panel · puncturedCABIN FLOOR PNL 52, ONE SMALL PUNCTURE ON SKIN 861-KK-82. FABBED & INSTALLED DOUBLER AS PER DC9 SRM 51-30-2, PG 1, 24-26B, PAR 7, MARKED USING REPAIR IDENTIFICATON REQUIREMENTS USING PROCESS STANDARD 900-5-1, NR 4, PG 1-6. INSTALLED REPAIR DOUBLER ON CABIN FSDR DALA1139629861Floor Panel · dentedCABIN FLOOR PNL 80 IS BOWED UP IN THE CENTER AND HAS MANY DENTS. 861-KK-84. RII: Y. FABRICATED NEW SKIN, REMOVED 2EA HAT CHANNELS FROM OLD SKIN, FLOOR PANEL 80, AND INSTALLED ON NEW SKIN FLOOR PANEL 80, IAW DC9 SRM 51-30-2, PG 1-4.SDR DALA1135919857Coalescer Bag · dirtyENROUTE, FLIGHT DIVERTED, DUE TO A PERSISTENT HOT PLASTIC BURNING ODOR IN THE FORWARD GALLEY BETWEEN MAIN DOOR AND FORWARD LAVATORY. THERE WAS NO VISUAL CONFIRMATION OF SMOKE. MAINTENANCE FOUND THE COALESCER BAGS SATURATED AND DIRTY, REMOVED AND REPLACED THSDR DALA1140549861Pan · deterioratedFWD CARGO DOOR OUTER PAN AREA UNDER PRESSURE SEAL PRIMER COATING DETERIORATED, PEELING UP, LIGHT CORROSION AND AREAS OF PROTECTIVE FINISH MISSING ALL THE WAY AROUND DOOR PAN. FWD CARGO DOOR OUTER PAN FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 52-01 FIG 1 P66. RSDR DALA1140519861Former · damagedCRACK ON FUSELAGE FORMER AT STA 1151, BELOW LONGERON 14R, REMOVED AND REPLACED FORMER, P/N J060119-40, BATCH 0002054712 IAW DC9 DRAWING J060119, REMOVED AND REINSTALLED ACCESS PANEL 820 2A AT RT LOWER PYLON IAW DC9 SRM 51-30-1. FORMER WAS REMOVED AND REPLACEDSDR DALA1140329861Seat Track · corrodedCORROSION ON MOUNTING TRACK FOR RIGHT AFT LAVATORY AT STA 1174, RBL 25. REMOVED MOUNTING TRACK FROM IAW DC9 SRM 51-30-2 & DC9 SRM 51-30-5, PAR 8, FIG 16, FABBED INTERCOSTAL PER REF DWG 94FS481223. TREATED AND PRIMED MOUNTING TRACK AS PER DC9 SRM 51-10-3. LOSDR DALA1139709861Doubler · crackedCRACK ON INTERNAL DOUBLR REPAIR AT FUSELAGE SKIN STA 1163, BELOW LONGERON 14R (093-29). RII: Y. REMOVED LONGERON ATTACH BRACKET BY FOM AT STA 1163, STR 14R IAW DC9 SRM 51-30-5, PG 29. REMOVED INTERNAL DOUBLER REPAIR AT FUSELAGE SKIN STA 1163, STR 14R IAW DCSDR DALA1139669861Former · crackedCRACK ON FUSELAGE FORMER AT STA 1151, BELOW LONGERON 14L (093-31). REMOVED FORMER, REMOVED 4 ANGLES, LONGERONS 13, 14, 15, 16 AND 1 SPLICE. OK TO INSTALL FORMER, 4 EA ANGLES, AND SPLICE. INSTALLED FORMER ON STA 1151, BELOW LONGERON 14L, INSTALLED 4 EA ANGLESDR DALA1139619861Floor Panel · damagedELONGATED 7 HOLES AT FLOOR PANEL 99. FABRICATED AND INSTALLED 07 EA. FABRICATED REPAIR WASHERS IN MAIN CABIN FLOOR PANEL 99 PER DC9 SRM 53-05, PG 12, FIG 3, PER DC9 SRM 51-60-0, PG 6, FIG 1 AND DC9 SRM 51-30-1.SDR DALA1139559861Former · crackedCRACK ON FUSELAGE FORMER AT STA 1151, BELOW LONGERON 14L. REMOVED FORMER ON STA 1151 BELOW LONGERON 14L, REMOVED 4 ANGLES STA 1151, LONGERONS 13,14,15,16, & 1 EA SPLICE PER DC9 SRM 51-30 -5, PG 30, 29. LOCATED AND DRILLED NEW FORMER PER DC9 SRM 51-10-4, PSDR DALA1135889866Floor Support · crackedMAIN CABIN FLOOR PANEL 66 HAS 5EA HAT CHANNELS CRACKED. REMOVED AND REPLACED 5 HAT CHANNELS IAW SRM 51-30-2. UPON INSP FOUND 2 CRACKS. CUTOUT DAMAGED AREA 2 INCH BY 1 1/2 INCH. NDT HFEC INSP IAW NDT SPM06-10-01. NO CRACKS NOTED. FABRICATED AND INSTALLESDR DALA1140349861Seat Track · corrodedSEAT TRACK LBL 44 HAS AREAS OF CORROSION FROM STA 200 TO 318. REMOVED CORR PER DC9 SRM 51-10-3, PG 3, 5. ORIGINAL .070 PER DC9 SRM 51-10-1, SRM 53-23-0, FIG 4 OUT OF LIMITS PER DC9 SRM 53-05, PG 28, REMOVED SEAT TRACK DC9 SRM 51-30-5, PG 29. FABBED SEAT TRACSDR DALA1140289861Floor Support · corrodedFLOOR SUPPORT ANGLE HAS AREAS OF CORROSION BL 0 FROM STA 160-318 BL 0. REMOVED CORROSION OUT OF LIMITS PER DC9 SRM 53-01, FIG 1, PG 8. REMOVED AND FABBED (2EA) FLOOR SUPPORTS SECTION PER DC9 SRM 53-13-1, FIG 11, PG 25-26 AND INST NEW FLOOR SUPPORTS IAW DC9 SDR DALA1140269861Floor Panel · damagedCABIN FLOOR PNL 102A, THREE EA FASTENER HOLES SHOWING WEAR AND PITTING. REMOVED CABIN FLOOR PANEL 102A ON TASK CARD 0590-0020-8M, CORROSION REMOVED IAW DC9 SRM 53-01, IN LIMITS PER DC9 SRM 53-02, PG 8. FABBED REPAIR DOUBLERS IAW DC9 SRM 53-05, PG 12, TREATESDR DALA1139949861Doubler · dentedLT EXTERIOR FUSELAGE EXTERNAL DOUBLER REPAIR IS DENTED AT BSTA Y235 AND BETWEEN LONGERONS 17L AND 18L (MAJOR REPAIR). RII: Y. REMOVED EXISTING DOUBLER, TRIMMED SKIN DAMAGE, HFEC NO DAMAGE NOTED, FABRICATED AND, INSTALLED REPAIR PARTS FROM STA 229 TO STA 249,SDR DALA1139809861Seat Track · corrodedSEAT TRACK RBL 44 HAS AREAS OF CORROSION FROM STA 200 TO 318. REMOVED CORROSION FROM SEAT TRACK PER DC9 SRM 51-10-3, PG 47, FOUND TO BE OUT OF LIMITS AT STA 200 TO 203 RBL 44 PER DC9 SRM 53-05, FIG 4B. REMOVED AND REPLACED SEAT TRACK SECTION AT STA 200 TO 26SDR DALA1139609861Floor Panel · dentedCABIN FLOOR PNL 75 HAS A DENT, PNL IS OFF A/C PART 861-KK-74. RII: Y. FABBED & INSTALLED REPAIR DOUBLER AS PER DC9 SRM 51-30-2, PG 24-26B, PAR 7 ON CABIN FLOOR PNL 75, MARKED USING REPAIR IDENTIFICATION REQUIREMENTS USING PROCESS STANDARD 900-5-1, NR 4, PG 1-SDR DALA1138519861Pan · crackedMAIN CABIN, STA Y794, LONG 12LT, WINDOW PAN WITH CRACK. CUT OUT DAMAGE MAIN CABIN WINDOW RING PAN AT STA Y794, LONGERON 12LT PER DC9 SRM 53-05, FIG 122. FABRICATED REPAIR DBLR MAIN CABIN WINDOW RING PAN USING FABBED SHIM, FABBED REPAIR WASHER, TREATED AND PRSDR DALA1138509861Floor Support · corrodedFLOOR SUPPORT ANGLE CRACKED, BENT, AND HAS LIGHT CORROSION, STA 180 BETWEEN BL-0 AND RBL-44. REMOVED DAMAGED FLOOR SUPPORT ANGLE AT STA 180, BETWEEN BL 0 AND RBL 44 IAW DC9 SRM 51-30-2, PG 26. FABRICATED NEW SUPPORT ANGLE IAW SRM DC9 53-13-1, PGS 25-26, INSTSDR DALA1138299861Floor Support · corrodedFLOOR SUPPORT ANGLE HAS CORROSION STA 200 BETWEEN RBL 22 AND RBL 44. REMOVED OUT OF LIMITS FLOOR SUPPORT ANGLE IAW DC9 SRM 51-10-3, PG 46. FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 PG 8. FABRICATED FLOOR SUPPORT ANGLE AT STA 200, RBL 22 RBL 24 IAW DC9 SRMSDR DALA1137119880Vane · dentedLT FLAP, MOVABLE VANE LWR SURFACE HAS A DENT. REPAIRED DENT IAW DC9 SRM 57-03, FIG 11, DC9 SRM 51-70-2, DC9 SRM 57-50-9, ITEM 2, FIG 1A, PG 3, DC9 SRM 57-03, PARA. 11B, DC9 SRM 51-70-2, DC9 SRM 51-10-3, PARA 21, DC9 SRM 51-70-2, DC9 SRM 51-10-3, REPAIRED BY CSDR DALA1139869861Panel · gougedRT WING T/E FLAP PANEL 1860NW HAS DEEP GOUGE CA415 (MAJOR REPAIR) RII: Y. CUT OUT DAMAGED AREA AT R/WING T/E PANEL, FABRICATED & INSTALLED DOUBLER REPAIR AND FILLER AT R/W T/E PANEL 1680NW IAW DC9 SRM 51-30-2, PAGE 8. RE-INSTALLED T/E PANEL, INSTALLED ID TAGSDR DALA1135599866Floor Support · crackedMAIN CABIN FLOOR PANEL 73 HAS BTM SIDE HAS 1 HAT CHANNEL CRACKED APPROX 1/2 IN. CUT OUT DAMAGED HAT CHANNEL (2 INCH LENGTH) IAW SRM 53-05 FIG 1. RECEIVED AND TRIMMED CHANNEL AND INSTALLED IAW SRM 53-05 FIG 1. TAGGED REPAIR IAW DPS 900-5-1 NR 4.SDR DALA1135309866Skin · damagedMAIN CABIN FLOOR PANEL 73 HAS 1 HOLE ON TOP SKIN. CUT OUT DAMAGE (1") IAW SRM 53-01 FIG, 4. NDT VERIFIED NO CRACK NOTED IAW NDT SPM 06-10-01. ORIG MAT OF PANEL 73 IS .020" 7075-T6 IAW SRM 53-23-0. FABRICATED DOUBLER FROM .032" 7075T6 AND INSTALLED IAW SRM 53SDR DALA1135299866Structure · chafedAFT ACC COMPT STA 1190 L17R HOLE CHAFED IN FR OB OF VALVE. CUT OUT DAMAGED AREA 2.5 INCH BY 1 INCH. NO DEFECTS PER NDT SPM 06-10-01.001. FIB FILLER FROM PART NR 9958233-27 AND DOUBLERS FROM.063 7075-T6 PART NR SR09530035-25. INSTALLED YAW DC9 SUM 5304 FIG SDR DALA1135159866Skin · crackedFUSELAGE EXTERIOR LT SIDE AIR STAIRS CUTOUT AFT LOWER CORNER HAS APPROX 2 INCH CRACK IN FUSELAGE SKIN. NDT VERIFIED CRACK. TRIMMED OUT SKIN WITH DIMENSIONS OF 1.5 IN BY 1.70 IN IAW DWG NR SR09530031. HFEC INSPECTED IAW NDT SPM 06-10-01.001.CRACK TO BE CONTASDR DALA1135079866Floorbeam · crackedMAIN CABIN OVERWING STA 775 RBL 52 FLOORBEAM CRACKED. REMOVED FLOORBEAM IAW DC9 SRM 51-30-1, 51-30-2, 51-30-05. RECEIVED NEW FLOORBEAM CFE PN NR 9915527 -506. LOCATED, DRILLED AND DEBURRED IAW DOUGLAS DRAWING 9915527. TREATED AND PRIMED IAW SRM 51-10-3. SDR DALA1135069866Web · crackedMAIN CABIN OVER WING RBL-44 BETWEEN STA 740 AND 770 WEB TO CENTER TANK ANGLE CRACKED. NDT MARKED ENDS OF CRACK PER NDT SPM 06-10-01. GAINED ACCESS AND REMOVED DAMAGED SECTION OF ANGLE FROM STA 700-780 RBL 44. RECEIVED NEW ANGLE. INSTALLED NEW ANGLE IAW SRMSDR DALA1134969866Vane · chafedLEFT WING MOVEABLE VANE INBD EDGE CHAFED AT LOWER END PARTS RACK 82B. -5 ZEE ANGLE AND -21 ANGLE FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 57-01 FIG 1. FABRICATED -21 ANGLE IAW DC9 SRM 51-10-02 MTL.032 2024 T3. TREATED AND PRIMED IAW DC-9 SRM 51-10-3. RECV NEWSDR DALA1134949866Access Panel · damagedRIGHT WING FUEL ACCESS 1472A LANDING HAS 1 MIS DRILLED HOLE. REAMED HOLE TO .435. FABRICATED FREEZE PLUG. INSTALLED IAW ERA 491735-14 P-226.SDR DALA1134889866Frame · gougedAFT WET AREA-STA 1136 LEFT LONG 4 PYLON BULKHEAD FRAME GOUGED. BLEND GOUGE 1" BY 4" ORIG .050 REMOVED .012 REMAINING .038. FOUND OUT OF LIMITS PER SRM 53-01.FAB AND INSTALLED 2 ANGLES FROM .040 7075-0 IAW SRM 53-02 FIG 2 SHEET 4. HEAT TREATED ON TRAVELER 25SDR DALA1134879866Frame · crackedMAIN CABIN STA 734 RIGHT LONG 18 MAIN FRAME CRACKED. REMOVED AND INST NEW FRAME PART NR 9923406-502 IAW 51-30-5, DWG 3924863.P-226. REQUIRED INSPECTION COMPLETED.SDR DALA1134209866Frame · crackedMAIN CABIN STA 753 RIGHT LONG 18 MAIN FRAME CRACKED. REMOVED MAIN FRAME AT STA 753 RIGHT LONG 18. RECEIVED NEW FRAME P/N 97-5300-3-0024. INSTALLED NEW FRAME IAW SRM 51-30-5 P226.SDR DALA1134199866Intercostal · crackedCOCKPIT BETWEEN STA 148 AND STA 160 LOWER INTERCOSTAL CRACKED AT FWD WIRE CONDUIT. REMOVED WEB ATTACH PLATE AND 2 BRACKETS TO FOM. REMOVED INTERCOSTAL IAW SRM 51-30-2. FABRICATED REPAIR ANGLES FROM 3011/2H .063 PO NR 0722363 IAW SRM 53- 05-51-10-2. INSTALSDR DALA1134169866Floor Support · corrodedMAIN CABIN STA 237-302 BL0 FLOOR SUPPORT HAS CORROSION REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-30-05. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1.SDR DALA1134139866Cusp Web · crackedMAIN CABIN BETWEEN STA 1044 AND 1060 LT CUSP WEB CRACKED SEVERAL PLACES. CUTOUT DAMAGE AREA 4.5 INCH BY 29.875 INCH. NO DEFECTS PER NDT SPM 06-10-01. FAB AND INSTALLED REPAIR FROM .032 INCH 7075-T6 IAW DWG SG09530019.P226. REQUIRED INSP.
Back to Mcdonnell Douglas DC-9-51