What was found
CORROSION ON MOUNTING TRACK FOR RIGHT AFT LAVATORY AT STA 1174, RBL 25. REMOVED MOUNTING TRACK FROM IAW DC9 SRM 51-30-2 & DC9 SRM 51-30-5, PAR 8, FIG 16, FABBED INTERCOSTAL PER REF DWG 94FS481223. TREATED AND PRIMED MOUNTING TRACK AS PER DC9 SRM 51-10-3. LOCATED AND DRILLED HOLES IAW DWG 94FS481223. INST PER DC9 SRM 51-30-2, AND SRM 51-30-5, AND DWG 99FS634222.