SDR ASAA0380642Hinge Fitting · corrodedOKC - DURING 30K CHECK, FOUND LEFT OUTBOARD FLAP HINGE FITTING AT OUTBOARD ACTUATOR POINT BEARING HOUSING IS CORRODED ON INNER SURFACE. REBORED FITTING AND INSTALLED OVERSIZED BUSHING PER OHM 27-50-5. (M)Oct 15, 2003 · N934AS · Doug DC982 · Trailing Edge FlapsSDR ASAA0380652Doubler · corrodedOKC - DURING 30K CHECK, FOUND FORWARD CARGO DOOR CUTOUT LOWER INNER DOUBLER IS CORRODED. REPLACED DOUBLER. (M)Oct 15, 2003 · N934AS · Doug DC982 · Fuselage Main, Plate/SkinSDR ASAA0380643Skin · corrodedOKC - DURING 30K CHECK, FOUND FUSELAGE SKIN IS CORRODED UNDER FRAME AT STATION 1287 AT 28R. REPLACED DAMAGED SECTION PER SRM 53-04. (M)Oct 15, 2003 · N934AS · Doug DC982 · Fuselage Main, Plate/SkinSDR GTIA030857Longeron · damagedFTW - FOUND DAMAGED LONGERON STATION FS 1271 L24L. REMOVED DAMAGED LONGERON AT L24L FS 1322-1271. FABRICATED NEW LONGERON. LOCATED AND DRILLED SPLICE. INSTALLED SPLICE AND LONGERON. (M)Oct 15, 2003 · N820NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20031147Battery Pack · inoperativeMAINTENANCE OBSERVED OVERWING EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 15, 2003 · N285AA · Doug DC982 · Emergency LightingSDR ASAA0380674Flange · chafedOKC - FOUND 30K CHECK, AFT CARGO BAY DOOR FLANGE IS CHAFED AT LOWER STOPS. BLENDED CHAFED AREA PER EA 5230-01205. (M)Oct 14, 2003 · N934AS · Doug DC982 · Cargo/Baggage DoorsSDR MEX2003488Door · damagedAFTER AIRCRAFT LANDED THRUST REVERSERS WERE EXTENDED BEFORE NOSE LANDING GEAR HAD BEEN CONTACT ON THE GROUND, SCRATCHING THE THRUST REVERSES LOWER DOORS OF BOTH ENGINES (LARGE: 12 INCH, WIDE 1.5 INCHES APPROX). PERSONNEL WAS SENT TO REPAIR THE DAMAGES. BOTH Oct 14, 2003 · N491SH · Doug DC982 · Engine Thrust ReverserSDR ASAA03805635Battery · inoperativeSEA LINE CHECK, FOUND TWO OVERWING EMERGENCY EXIT LIGHTS FAILED TO OPERATE UPON CHECK. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED NORMALLY. (M)Oct 13, 2003 · N967AS · Doug DC982 · Emergency LightingSDR GTIA030859Skin · dentedFTW - FOUND DENT AT FS 1276 TO FS 1315 BETWEEN LONGERONS 23 AND 24L, REQUIRES REPAIR. DENT AT FS 1276 SHOULD BE INCORPORATED INTO THIS REPAIR. CUT OUT DAMAGED SECTION OF SKIN FROM STATION 1276-1315. FABRICATED INNER DOUBLERS, FINGER DOUBLER AND NEW SKIN. IOct 13, 2003 · N820NK · Doug DC982 · Fuselage Main, Plate/SkinSDR ASAA0380634Power Supply · dischargedOAK LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE BETWEEN ROWS 19 AND 24. CLEANED ELECTRICAL CONNECTOR IN THE AREA. LIGHTS THEN OPERATED PROPERLY. (M)Oct 12, 2003 · N935AS · Doug DC982 · Emergency LightingSDR GTIA030860Floorboard · delaminatedFTW - FOUND PAX CABIN FLOORBOARD DELAMINATED AT FORWARD F/A SEAT AREA. FABRICATED NEW FLOORBOARD. (M)Oct 12, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR CALA0300589Doubler · corrodedINSPECTION FOUND INTERNAL DOUBLER FOR OUTFLOW VALVE CORRODED AT STA 1325 BETWEEN L21L AND L22L. THE DOUBLER WAS REMOVED AND REPLACED IAW SRM 51-30-02.Oct 12, 2003 · N92874 · Doug DC982 · Fuselage Main, Plate/SkinSDR ASAA0380633Connector · disconnectedPDX PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED LOOSE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)Oct 11, 2003 · N935AS · Doug DC982 · Emergency LightingSDR ASAA0380632Power Supply · inoperativeSEA LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN. SPLICED IN NEW CONNECTOR WIRE AT ROW 1. ALSO, REPLACED BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)Oct 11, 2003 · N935AS · Doug DC982 · Emergency LightingSDR AALA20031135Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY LIGHT INOPERATIVE IN THE TAILCONE WALKWAY. REPAIRED ELECTRICAL WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 11, 2003 · N586AA · Doug DC982 · Light System WiringSDR AALA20031134Socket · inoperativeDURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY LIGHT INOPERATIVE AT SEAT 30D. REPLACED LIGHT SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 11, 2003 · N443AA · Doug DC982 · Emergency LightingSDR GTIA030844Floor Support · corrodedFOUND FLOOR SUPPORT AT FS 146 TO 154 LBL 53 HAS CORROSION. FLOOR SUPPORT REMOVED. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)Oct 11, 2003 · N820NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030814Fitting · corrodedFOUND MID PIT STATION 693 TEE FITTING CORRODED/ELONGATED HOLES. FABRICATED NEW T-FITTING. (M)Oct 10, 2003 · N820NK · Doug DC982 · Fuselage Main, Attach FittingsSDR AALA20031141Clamp · damagedAIRCRAFT EN ROUTE, OBSERVED HIGH TEMPERATURE LIGHT COMING ON FOR TAIL COMPARTMENT. RETURNED TO LAND, LIGHT WENT OUT ON DESCENT AND LANDING. ACCOMPLISHED OVERWEIGHT LANDING INSPECTION. FOUND AIR LEAK AND REPLACED CLAMP. SYSTEM GROUND CHECKED NORMAL OPERATIONOct 10, 2003 · N408AA · Doug DC982 · Air Distribution SystemSDR AALA20031142Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY LIGHTS INOPERATIVE AFT OF ROW 31. REPAIRED ELECTRICAL WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 10, 2003 · N70504 · Doug DC982 · Light System WiringSDR GTIA030851Plate · corrodedFTW - FOUND TWO CORRODED FLOOR PLATES AT FS 160, 18 INCHES LBL. FABRICATED FLOOR PLATE. TWO FLOOR PLATES ARE REMOVED AND INSTALLED ON SAS W/C B00104 18-R-15. (M)Oct 10, 2003 · N820NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20031140Wire · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY LIGHT INOPERATIVE AT THE AFT STAIRWAY. REPAIRED ELECTRICAL WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 10, 2003 · N408AA · Doug DC982 · Light System WiringSDR GTIA030843Web · corrodedFOUND SUBFLOOR CORRODED STATION 195 LBL 50. REMVOED WEB. FABRICATED NEW WEB. INSTALLED WEB. (M)Oct 10, 2003 · N820NK · Doug DC982 · Fuselage Miscellaneous StructureSDR FEF200300003Spar Cap · corrodedDURING THE C7 CHECK, PERFORMING THE TASK NR 0805, AND LOCAL CORROSION WAS FOUND AT RT LOWER SPAR CAP. XRS262~XRS267 L=5" W=1.2" D=0.8" ACTION TAKEN: REQUEST MFG ASSISTANCE FOR PERMANENT REPAIR AND IAW MFG RESPONSE REPAIR THE CORROSION. MANUFACTURER OFFEREOct 10, 2003 · Doug DC982 · Wing SparSDR ASAA03805629Battery Pack · inoperativeOKC - DURING 30K CHECK, FOUND LEFT AND RIGHT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE, FAILED TO OPERATE UPON CHECK. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)Oct 9, 2003 · N967AS · Doug DC982 · Emergency LightingSDR GTIA030811Web · crackedFOUND AFT AIRSTAIRS CUT OUT AFT SIDE WEB HAS TWO CRACKS IN IT. CUT OUT TWO DAMAGED AREAS. FABRICATED TWO FILLERS, TWO DOUBLERS. INSTALLED TWO FILLER AND DOUBLER. (M)Oct 9, 2003 · N829NK · Doug DC982 · Entrance StairsSDR AALA20031128Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE IN THE AFT TAILCONE. REPLACED ELECTRICAL CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 9, 2003 · N423AA · Doug DC982 · Emergency LightingSDR GTIA030885Yoke · damagedFTW - NR 2 YOKE ASSEMBLY UPPER ISOLATOR CONICAL SURFACE WORN. REMOVED NR 2 UPPER FORWARD ISOLATOR. INSTALLED NEW ISOLATOR. UPON INSTALLATION OF YOKE ASSEMBLY FOUND UPPER ISOLATOR INNER ASSEMBLY LOOSE. FOUND ISOLATOR INNER ASSEMBLY STILL LOOSE. REMOVED UPPOct 9, 2003 · N820NK · Doug DC982 · Engine Mount SectionSDR GTIA030805Floor Panel · crackedFTW - FOUND FORWARD CABIN STA 200 TO 256 LBL 14 TO 21 FLOOR PANEL HAS CRACKED/DAMAGED AT CORNERS. FABRICATED NEW FLOOR PANEL. (M)Oct 8, 2003 · N830NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030806Web · crackedWEB FOUND CABIN STATION 207 STRINGER 15L AND 11L WEB CRACKED. FABRICATED WEB REPAIR. INSTALLED WEB REPAIR. (M)Oct 8, 2003 · N830NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20031126Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT AFT AIR STAIR. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 8, 2003 · N557AN · Doug DC982 · Emergency LightingSDR AALA20031129Light · inoperativeOVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE L1 DOOR EXIT. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 8, 2003 · N486AA · Doug DC982 · Emergency LightingSDR CALA0300579Cargo Track · corrodedINSPECTION FOUND FORWARD BAGGAGE BIN RT AFT CARGO TRACK CORRODED AT ATTACH SCREWS IN THREE PLACES FROM STA 465-503. THE CARGO TRACK WAS REMOVED AND REPLACED IAW SRM 51-30-01.Oct 8, 2003 · N14831 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380603Power Supply · inoperativeSEA LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE FROM ROW 19. REPLACED ASSOCIATED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)Oct 6, 2003 · N935AS · Doug DC982 · Emergency LightingSDR GTIA030834Floorboard · brokenFOUND FORWARD CABIN STATION 200 TO 256 LBL 21 TO LBL 44 FLOORBOARD HAS SEVERAL INSERTS BROKEN OUT/CORRODED SOFT/MUSHEY AND DAMAGE ALONG EDGE. FABRICATED NEW FLOORBOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030835Floor Panel · corrodedFTW - FOUND FORWARD CABIN FLOOR PANEL STATION 160-200 CENTER HAS SEVERAL INSERTS BROKEN OUT/CORRODED AND SOFT/MUSHEY. FABRICATED NEW FLOOR PANEL. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030813Wire · disconnectedFOUND RIGHT SIDE LOWER FORWARD EXIT SIGN INOPERATIVE. FOUND WIRING DISCONNECTED. RECONNECTED WIRING. (M)Oct 6, 2003 · N829NK · Doug DC982 · Light System WiringSDR GTIA030832Floorboard · corrodedFORWARD CABIN STATION 200 TO 256 CENTER FLOORBOARD HAS SEVERAL INSERTS BROKEN OUT/CORRODED SOFT/MUSHEY AND DAMAGED ALL CORNERS. FABRICATED NEW FLOORBOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030833Floor Panel · crackedFORWARD CABIN STATION 200 TO 256 RBL 45.5 TO RBL 55 METALLIC PANEL HAS CRACKED/DAMAGED AT HAT CHANNEL AND EXPANSION JOINT CRACK/DISBONDED. FABRICATED REPAIRS. INSTALLED HAT CHANNEL REPAIRS. REPAIRED DISONDED AREA. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030836Floorboard · corrodedFTW - FOUND FORWARD CABIN STATION 200 TO STATION 180 RBL 8 INCHES TO RBL 44 FLOOR PANEL HAS SEVERAL INSERTS BROKEN OUT/CORRODED/SOFT/MUSHEY. FABRICATED NEW FLOORBOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR AALA20031115Battery Pack · dischargedAUS - FOUND DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT PACK B5-2. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 6, 2003 · N228AA · Doug DC982 · Emergency LightingSDR GTIA030842Floorboard · corrodedFTW - FOUND FORWARD CABIN FLOORBOARD STATION 200 TO STATION 256 LBL 14.5 TO LBL 21 HAS SEVERAL INSERTS BROKEN OUT, CORRODED, SOFT/MUSHEY. FABRICATED NEW FLOOR BOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030837Floorboard · corrodedFOUND FORWARD CABIN FLOORBOARD STATION 180 TO STATION 160 RBL 8 INCHES TO RBL 44 HAS SEVERAL INSERTS BROKEN OUT, CORRODED AND SOFT/MUSHEY. FABRICATED NEW FLOOR BOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030838Floorboard · corrodedFORWARD CABIN FLOOR BOARD STATION 200 TO STATION 160 RBL 44 TO RBL 55 HAS SEVERAL INSERTS CORRODED/SOFT MUCHEY. FABRICATED NEW FORWARD CABIN FLOOR BOARD. (M)Oct 6, 2003 · N820NK · Doug DC982 · Fuselage Floor PanelSDR CALA0300575Door Frame · corrodedINSPECTION FOUND AFT CARGO COMPARTMENT LOWER DOOR JAMB CORRODED. A SPACER WAS FABRICATED AND INSTALLED IAW SRM 53-05.Oct 6, 2003 · N14831 · Doug DC982 · Fuselage Main, StructureSDR AALA20031117Battery Pack · dischargedBNA - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE MID CEILING LOCATION. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 5, 2003 · N7509 · Doug DC982 · Emergency LightingSDR AALA20031120Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 4, 2003 · N576AA · Doug DC982 · Emergency LightingSDR CALA0300573Door Frame · corrodedINSPECTION FOUND MID BAGGAGE BIN LOWER DOOR JAMB CORRODED. A SPACER WAS FABRICATED AND INSTALLED IAW SRM 53-05.Oct 4, 2003 · N14831 · Doug DC982 · Fuselage Main, StructureSDR AAL2004F00004Spar Cap · damagedRT WING REAR SPAR LOWER CAP DAMAGED (GROUND DAMAGE). INSTALLED SERVICEABLE LOWER CAP DOUBLER AND FILLER IAW ESO 80559.Oct 3, 2003 · N411AA · Doug DC982 · Wing SparSDR ASAA0380602Light · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 4. SPLICED BROKEN WIRE. LIGHTS THEN OPERATED PROPERLY. (M)Oct 3, 2003 · N931AS · Doug DC982 · Emergency Lighting
Back to Mcdonnell Douglas DC-9-82