Mcdonnell Douglas DC-9-82
Service difficulty reports · 23,866
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20031122Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE OVERWING EXIT. INSTALLED WIRE AT BATTERY PACK B5-105. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031123Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT 9D. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031124Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT 4E. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031121Battery Pack · looseDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT TAILCONE. SECURED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031102Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE AFT GALLEY DOOR SECTION. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031101Battery Pack · dischargedRDU - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031103Battery Pack · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE OVERWING DOOR SECTION. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031104Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT ROWS 26 THROUGH 31. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031100Socket · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT 8D. REPLACED LIGHT SOCKET SYSTEM GRUOND CHECKED NORMAL OPERATION. (M)SDR MEX2003459Wheel · stuckAIRCRAFT RETURN TO PLATFORM DUE TO TAXING VIBRATION WS FELT ON THE BRAKES AND THE AIRCRAFT STOPS BY ITSELF. DURING REVISION WAS DETECTED THE BRAKE NUMBER THREE TIED. BRAKE ASSEMBLY AND TIRE NUMBER 3 WAS REPLACED IAW MM 32-42-01 AND 32-40-01.SDR ASAA0380599Light · inoperativeSEA PREFLIGHT CHECK, FOUND EMEREGNCY FLOOR TRACK LIGHTS INOPERATIVE FROM ROW 9 FORWARD. REPAIRED ASSOCIATED JUMPER WIRE TO BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)SDR AALA20031125Battery Pack · dischargedIAD - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE IN THE FIRST CLASS SECTION. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030862Beam · crackedFOUND L1 DOOR FORWARD VERTICAL BEAM AND STRAP CRACKED/BENT. REMOVED T-ANGLE. REMOVED CRACKED STRAP. REMOVED FORWARD VERTICAL BEAM. FABRICATED REPLACEMENT VERTICAL BEAM AND STRAP. INSTALLED NEW VERTICAL BEAM, NEW STRAP AND T-ANGLE. (M)SDR GTIA030879Cap · crackedFOUND RIGHT WING NR 5 SLAT OUTBOARD END CAP IS CRACKED. REMOVED END CAP. LOCATED AND DRILLED NEW PART. INSTALLED NEW END CAP. (M)SDR GTIA030823Floor Support · corrodedFOUND FLOOR SUPPORT CORRODED AT FS 148-200, 0 INCHES BL, FLIGHT COMPARTMENT. REMOVED FLOOR SUPPORT. LOCATED AND DRILLED HOLES AT NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030824Floor Support · corrodedFOUND FLT COMPARTMENT FLOOR SUPPORT CORRODED AT FS 160 0 INCHES TO 11 INCHES LBL. REMVOED FLOOR SUPPORT. FABRICATED NEW PART. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030825Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 180, 0-36 INCHES RBL. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030826Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 200 0-36 INCHES RBL. REMOVED CABIN FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030807Channel · crackedFOUND FORWARD CABIN PANEL RIGHT OUTBOARD STATION 256-313 CHANNEL CRACKED AT FORWARD AND AFT ENDS AND BENT. REMOVED DAMAGED CHANNEL. FABRICATED NEW CHANNEL. INSTALLED HAT CHANNEL. (M)SDR GTIA030827Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 160-200, 36 INCHES RBL. REMOVED CABIN FLOOR SUPPORT. LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030828Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 200 16 INCHES-20 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030829Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 200-205, 21 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED NEW CABIN FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030830Floor Support · corrodedFOUND CABIN FLOOR SUPPORT 2 INCH LONG CORROSION AT FS 200 51 INCHES LBL. REMVOED FLOOR SUPPORT. FABRICATED NEW CABIN FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030831Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 218 0 INCHES - 22 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR AALA20031092Battery Pack · dischargedDURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT ROWS 20 THROUGH 25. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031088Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030852Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 200-208 60 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030854Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 200 22 INCH - 50 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030881Fitting · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 160-200 48 INCHES RBL. FLOOR SUPPORT ATTACHMENTS 2 AT FS 165 AND 200 48 INCHES RBL OUT OF LIMITS. REMOVED FLOOR SUPPORT ATTACHMENTS TWO, LOCATED AND DRILLED NEW FITTINGS. INSTALLED FLOOR SUPPORT AT ATTACHMENTS SDR GTIA030846Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORROSION AT FS 160-200 62 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030845Floor Support · corrodedFOUND CABIN FLOOR SUPPORT CORRODED AT FS 200-255 22 INCHES LBL. REMOVED FLOOR SUPPORT. FORMED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030847Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORROSION AT FS 160-200 51 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA030839Web · corrodedFOUND CABIN SUB FLOOR CORRODED AT FS 200 16 INCHES LBL. CUT OUT CORRODED AREA. FABRICATED 1 FILLER AND 1 DOUBLER. INSTALLED FILLER AND DOUBLER. FLOOR SUPPORT CORRODED. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030840Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 148-200 14 INCHES LBL. REMOVED FLOOR SUPPORT. FABRICATED FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA030819Floorbeam · corrodedFOUND RIGHT AFT LAV STATION 1322 RBL 19-54, FLOORBEAM CORRODED. TRIMMED OUT DAMAGED AREA. DRILLED AND LOCATED ANGLE/FILLER. INSTALLED REPAIR ANGLE AND FILLER. (M)SDR GTIA030821Floor Support · crackedFOUND FLOORBOARD SUPPORT BROKEN AND CRACKED AT STATON 864 OVER CENTER WING TANK. REMOVED FLOORBOARD SUPPORT. FABRICATED NEW FLOORBOARD SUPPORT. INSTALLED NEW SUPPORT. (M)SDR GTIA030822Angle · crackedFOUND WEB ANGLE ATTACHMENT STATION 864 OVER CENTER WING TANK CRACKED. REMOVED CRACKED ANGLE. FABRICATED NEW ANGLE. INSTALLED NEW ANGLE. (M)SDR GTIA030858Doubler · crackedFTW - FOUND RIGHT SIDE MLG FORWARD DOOR JAMB FRAME ATTACHED KEEL BEAM CRACKED AT DOUBLER. REMOVED DAMAGED REPAIR DOUBLER. FABRICATED NEW REPAIR DOUBLERS. INSTALLED REPAIR DOUBLER. (M)SDR AALA20031084Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT THE AFT SERVICE DOOR LOCATION. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AAL2004F00000Seat Track · corrodedCORROSION ON NR 1 SEAT TRACK AT STA 1278. INSTALLED PLUG AT STA 1278, NR 1 SEAT TRACK IAW SRM AND TREATED AND PRIMED.SDR GTIA030818Floorbeam · corrodedFTW - FOUND LEFT AFT LAV STATION 1338 LBL 19 LBL 54 FLOORBEAM CORRODED. TRIMMED OUT DAMAGED AREA. FABRICATED REPAIR ANGLE AND FILLER. INSTALLED REPAIR PARTS. (M)SDR GTIA030820Web · crackedFOUND CABIN STATION 1309 RBL 46 FLOOR WEB CRACKED UNDERNEATH SEAT TRACK. TRIMMED OUT DAMAGED/CRACKED AREA. DRILLED AND LOCATED FILLER AND DOUBLER. INSTALLED REPAIR DOUBLER AND FILLER. (M)SDR AALA20031087Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING WAS INOPERATIVE AT THE FIRST CLASS OVERHEAD. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031086Light · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING WAS INOPERATIVE AT THE FORWARD GALLEY LOCATION. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AAL2004F00001Longeron · crackedCRACK ON LONGERON 46 AT STA 700. CRACKED IN SECTION NEXT TO LOWER ATTACH FASTENER. SPLICED IN NEW SECTION OF LONGERON FROM STA 180 TO STA 235.SDR GTIA030817Floorboard · crackedFOUND FLOORBOARD STATION 598-636 DENTED/CRACKED. FABRICATED NEW FLOORBOARD. (M)SDR AALA20031076Engine · bird ingestionEN ROUTE, AIRCRAFT ENGINE INGESTED BIRD INTO THE NR 2 ENGINE. DECLARED EMERGENCY AND LANDED WITHOUT INCIDENT. AIRCRAFT OVERWEIGHT INSPECTION PERFORMED. REPLACED THE NR 2 ENGINE. LEAK AND SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030861Structure · crackedFTW - FOUND L1 DOOR CRACKED 2 PLACES IN RADIUS AT AFT SIDE 2ND ACCESS FROM TOP AND FORWARD SIDE 2ND ACCESS HOLE FROM TOP. STOP DRILLED CRACKS. (M)SDR GTIA030870Panel · delaminatedFOUND RIGHT WING BOTTOM TRAILING EDGE TRAP PANEL JUST FORWARD OF RT MLG DELAMINATED. REMOVED RIGHT WING BOTTOM TRAP PANEL. REPAIRED RT WING BOTTOM TE TRAP PANEL INSTALLED RIGHT BOTTOM TE TRAP PANEL. (M)SDR GTIA030882Panel · delaminatedFOUND LEFT WING LOWER TRAP PANEL MLG DELAMINATED. REMOVED LEFT WING LOWER TRAP PANEL. REPAIRED LEFT TRAP PANEL. INSTALLED PANEL. (M)
Back to Mcdonnell Douglas DC-9-82