Mcdonnell Douglas DC-9-82

Service difficulty reports · 23,866

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC982'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20030779Pump · defectiveORD - FLT 1771 - EN ROUTE ORD-ELP, AFTER TAKEOFF PASSING 4000 FEET IN RIGHT TURN,RIGHT ENGINE FLAMED OUT. ACCOMPLISHED RESTART NORMALLY. RETURNED ORD AND LANDED WITHOUT FURTHER INCIDENT. REPLACED FUEL PUMP AND CONTROL PER MM. LEAK CHECKS NORMAL. SYSTEM GRJul 16, 2003 · N7528A · Doug DC982 · Engine Fuel PumpSDR GTIA030597Floorboard · corrodedFTIA - FOUND CABIN FLOORBOARD AT FS 1271-1338 CTR CORRODED AND BROKEN INSERTS AND BROKEN CORNER/EDGES. FABRICATED NEW FLOORBOARD. (M)Jul 16, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030596Floorboard · corrodedFTW - FOUND CABIN FLOORBOARD CORRODED, BROKEN INSERTS, EDGES BROKEN, FS 1271-1338. FABRICATED NEW FLOORBOARD. (M)Jul 16, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR AALA20030776Connector · inoperativeDURING OVERNIGHT MAINTENANCE, FORWARD TAIL CONE EMERGENCY EXIT LIGHTS INOPERATIVE. SECURED EMERGENCY EXIT LIGHT CONNECTOR AT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 16, 2003 · N456AA · Doug DC982 · Emergency LightingSDR AALA20030777Connector · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, BOTH EMERGENCY EXIT CEILING LIGHTS INBOARD OF AFT GALLEY DOOR INOPERATIVE. SECURED EMERGENCY EXIT LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 16, 2003 · N472AA · Doug DC982 · Light System WiringSDR GTIA030584Floor Panel · crackedFTW - MAIN CABIN LEFT SIDE STATION 1174 TO 1250 SUB-FLOOR PANEL (PHENOLIC) HAS DISBONDED AT LOWER HATS SECTION AND CRACKS AT FORWARD EDGE. REPAIRED LOWER HAT SECTIONS AND CRACKS ON SUB FLOOR PANEL STATION 1174 TO 1250. (M)Jul 15, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR MWEA030280Skin · crackedTWO CRACKS IN FUSELAGE SKIN AT STATION 1437 BETWEEN LONGERON 3&4 RIGHT. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER AND FILLER.Jul 15, 2003 · N809ME · Doug DC982 · Fuselage Main, Plate/SkinSDR MWEA030279Longeron · crackedLONGERON 16 LEFT IS CRACKED ON BACK SIDE OF HAT SECTION AT STATION 313. FABRICATED AND INSTALLED NEW LONGERON.Jul 15, 2003 · N809ME · Doug DC982 · Fuselage Main, Longeron/StringerSDR MWEA030278Skin · cracked3 CRACKS IN FUSELAGE SKIN AT STATION 1437 BETWEEN LONGERON 3L AND LONGERON 5L. FABRICATED AND INSTALLED DOUBLER AND FILLERS.Jul 15, 2003 · N809ME · Doug DC982 · Fuselage Main, Plate/SkinSDR MWEA030277Fitting · crackedFORWARD CARGO DOOR INTERIOR FITTING CRACKED INBOARD OF AFT HINGE. FABRICATED AND INSTALLED FITTINGS.Jul 15, 2003 · N809ME · Doug DC982 · Cargo/Baggage DoorsSDR MWEA030276Fitting · crackedFORWARD CARGO DOOR INTERIOR FITTING CRACKED INBOARD OF FORWARD HINGE. FABRICATED AND INSTALLED FITTINGS.Jul 15, 2003 · N809ME · Doug DC982 · Cargo/Baggage DoorsSDR MEX2003288Switch · malfunctionedFLT 215 - HMO-GDL - AIRCRAFT ARRIVED WITH CAPTAIN REPORT 'L ICE PROTECT TEMP HI' LIGHTS TURN ON. DURING TRANSIT CHECK THE THERMOSTAT AND ANTICIPATOR WERE REPLACED IAW MM 36-10-00. AIRCRAFT WAS DISPATCHED AND AIR TURN BACK AS A CONSEQUENCE OF 'L ICE PROTECT TEJul 14, 2003 · N491SH · Doug DC982 · Airfoil Anti/De-ice SystemSDR ASOA03307Cam · out of rigFLT 4140 - DURING GROUND INSPECTION IN DFW, THE MAIN PASSENGER DOOR WOULD NOT OPEN FROM THE OUTSIDE AND DIFFICULT TO OPEN FROM THE INSIDE. MAINTENANCE RIGGED THE MAIN PASSENGER DOOR UPPER CAM MECHANISM. OPERATIONAL AND WARNING CHECKS GOOD. AIRCRAFT OK FOR SJul 13, 2003 · N829US · Doug DC982 · Passenger/Crew DoorsSDR AALA20030743Battery · inoperativeORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 13, 2003 · N553AA · Doug DC982 · Emergency LightingSDR ASAA0380535Slide · disconnectedPREFLIGHT CHECK, FORWARD SERVICE R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND INOPERATIVE, DISCONNECTED. 'RESET' RECONNECTED LANYARD. (M)Jul 9, 2003 · N954AS · Doug DC982 · Escape SlideSDR ASAA0380533Window · stiffPREFLIGHT CHECK, RIGHT SLIDING CLEARVIEW WINDOW IS HARD TO OPEN. ADJUSTED (RE-RIGGED) WINDOW. WINDOW THEN OPERATED PROPERLY. (M)Jul 9, 2003 · N967AS · Doug DC982 · Flight Compartment WindowsSDR AALA20030733Battery · dischargedDFW - EMERGENCY LIGHT AT AFT GALLEY FLOOR JUST FORWARD OF DOOR IS INOPERATIVE. REPLACED BATTERY AND CHARGER MODULE. SYSTEM GROND CHECKED NORMAL OPERATION. (M)Jul 9, 2003 · N471AA · Doug DC982 · Emergency LightingSDR AALA20030732Charger · inoperativeDFW - EMERGENCY LIGHT IN CEILING AT ROWS 8, 9, 10, 11 ARE INOPERATIVE. REPLACED BATTERY CHARGER ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 9, 2003 · N471AA · Doug DC982 · Emergency LightingSDR AALA20030738Engine · flamed outSMF - FLT 1842 - EN ROUTE SMF-DFW, AFTER DEPARTURE, THE FLIGHT CREW REPORTED THE RIGHT ENGINE HAD A FLAME OUT. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO SMF WITHOUT FURTHER INCIDENT. REPLACED RIGHT ENGINE USING MAINTENANCE CHECK MANUAL CARD 71-9Jul 9, 2003 · N461AA · Doug DC982 · Engine (Turbine/Turboprop)SDR GTIA030607Support · brokenFTW - FOUND LEFT INBOARD SPOILER TORSION BAR OUTBOARD SUPPORT BROKEN. REMOVED LEFT INBOARD SPOILER TORSION BAR OUTBOARD SUPPORT. INSTALLED NEW SUPPORT. (M)Jul 9, 2003 · N804NK · Doug DC982 · SpoilersSDR GTIA030592Fitting · corrodedFTW - FOUND LEFT OUTBOARD SPOILER TORSION BAR INBOARD FITTING HAS CORROSION. REMOVED FITTING. LOCATED AND DRILLED NEW ORDERED TORSION BAR FITTING. INSTALLED NEW FITTING. (M)Jul 9, 2003 · N804NK · Doug DC982 · SpoilersSDR GTIA030578Web · corrodedFTW - FOUND WEB CORRODED STATION 236-256 RBL 44-54. REMOVED WEB. FABRICATED NEW WEB. INSTALLED NEW WEB. (M)Jul 9, 2003 · N804NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20030728Switch · out of adjustORD - FLT 2034 - EN ROUTE ORD-BOS - AFTER TAKEOFF, LANDING GEAR FAILED TO RETRACT. THEN THE CABIN PRESSURE DUMPED, RECEIVED STALL INDICATION FAILURE AND AUTO SPOILER DO NOT USE LIGHTS ON. RETURNED TO ORD WITHOUT FURTHER INCIDENT. FOUND NOSE GEAR OLEO SWITCHJul 8, 2003 · N456AA · Doug DC982 · Landing Gear Position and WarningSDR AALA20030727Clamp · looseLAS - FLT 1560 - EN ROUTE LAS-DFW, SHORTLY AFTER TAKEOFF, TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. EMERGENCY DECLARED AND AIRCRAFT RETURNED TO LAS WITHOUT FURTHER INCIDENT. FOUND CLAMP BETWEEN AIR CYCLE MACHINE AND HEAT EXCHANGER LEAKING HOT AIR.Jul 8, 2003 · N226AA · Doug DC982 · Air Distribution SystemSDR GTIA030577Structure · crackedFTW - FOUND SUBFLOOR AT STATION 210 RBL 24 CRACKED. REMOVED SUBFLOOR. INSTALLED SUBFLOOR. (M)Jul 8, 2003 · N804NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030576Structure · corrodedFTW - FOUND SUB FLOOR AT STATION 200 RBL 24 HAS CORROSION. CUT OUT DAMAGED SECTION OF SUB FLOOR. FABRICATED NEW SUB FLOOR SECTION AND DOUBLERS. INSTALLED SUB FLOOR AND DOUBLERS. (M)Jul 8, 2003 · N804NK · Doug DC982 · Fuselage Miscellaneous StructureSDR ASAA0380530Lanyard · disconnectedPDX - PREFLIGHT CHECK, FORWARD PAX (L-1) DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)Jul 7, 2003 · N953AS · Doug DC982 · Escape SlideSDR AALA20030720Battery Pack · dischargedDFW - BOTTOM LAMP IN TAILCONE THREE LAMP ASSEMBLY AND AFT CABIN CEILING EMERGENCY LIGHTS ARE INOPERATIVE NEAR AFT LAVATORIES. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 7, 2003 · N241AA · Doug DC982 · Emergency LightingSDR MEX2003270Control Unit · failedDURING PREFLIGHT TRANSIT CHECK WAS DETECTED THE ENGINE FIRE ALARM SYSTEM DID NOT CANCEL AURAL WARNING. DURING REVISION RIGHT ENGINE LOOP B, BREAKER B-1 AND AMPLIFIER A2-6 WERE WITH DAMAGES. THE DUAL CONTROL UNIT WAS REPLACED IAW MM, ALL TESTS CORRECT.Jul 7, 2003 · N505MD · Doug DC982 · Fire DetectionSDR AALA20030723Battery Pack · not seatedSFO - EMERGENCY LIGHTS GO DIM AND THEN OFF IN FIVE SECONDS AT ROWS 22, 24, AND 26. RESEATED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 5, 2003 · N475AA · Doug DC982 · Emergency LightingSDR AALA20030722Wire · brokenDFW - EXIT IDENTIFIER BETWEEN 1ST CLASS AND FORWARD GALLEY INOPERATIVE. REPAIRED BROKEN WIRE FOR EXIT IDENTIFIER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 4, 2003 · N505AA · Doug DC982 · Light System WiringSDR AALA20030719Connector · looseDFW - OVERHEAD EMERGENCY LIGHT INOPERATIVE IN CABIN. RECONNECTED LOOSE CONNECTION AT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 4, 2003 · N210AA · Doug DC982 · Emergency LightingSDR ZW0A0305601Pressure Switch · faultyDURING CLIMB FAILURE OF FILTER CLOG LIGHT OF RIGHT ENGINE ILLUMINATED. MADE UNSCHEDULED LANDING AT IAD AT IDLG AND DID NOT SHUT DOWN ENGINE. REMOVED OIL FILTER FOR INSPECTION NTF. INSTALLED NEW FILTER CPN 5790859. RAN ENGINE CLOG LIGHT ILLUMINATED. CHANGED RIGJul 4, 2003 · N912TW · Doug DC982 · Engine Oil Indicating SystemSDR GTIA030548Web · crackedFTW - FOUND FORWARD CABIN STATION 200 TO STATION 160 LBL 54 INCHES SUB FLOOR WEB ELONGATED HOLES/CRACKED. REMOVED SUB FLOOR WEB FS 160-200. FABRICATED NEW SUB FLOOR WEB. INSTALLED NEW SUB FLOOR WEB. (M)Jul 3, 2003 · N804NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20030709Acm · lack of lubeSAN - FLT 736 - EN ROUTE SAN-DFW, IMMEDIATELY AFTER TAKEOFF CABIN BEGAN TO FILL UP WITH A BLUE HAZE/SMOKE. RAN EMERGENCY PROCEDURES AND RETURNED TO SAN. SMOKE FINALLY BEGAN TO DISSIPATE JUST PRIOR TO LANDING. SERVICED ACMS TO PROPER LEVEL. ACCOMPLISHED PACJul 2, 2003 · N496AA · Doug DC982 · Cabin Cooling SystemSDR GTIA030590Floorbeam · corrodedFTW - FOUND CABIN FS 1338 FLOORBEAM UPPER SIDE CORRODED/BARE METAL LBL 57-RBL 57. CUT APPROX 2 INCHES BY 1 INCH SECTION OUT OF TOP FLANGE. FABRICATED REPAIR ANGLE-FILLER. INSTALLED REPAIR ANGLE AND FILLERS. (M)Jul 2, 2003 · N804NK · Doug DC982 · Fuselage Main, Floor BeamSDR GTIA030591Floor Panel · corrodedFTW - FORWARD LAVATORY VANITY WALL UNDER SINK AREA FLOOR CORRODED. REMOVED FLOOR. FABRICATED NEW FLOOR. INSTALLED NEW FLOOR. (M)Jul 2, 2003 · N804NK · Doug DC982 · LavatoriesSDR GTIA030575Web · corrodedFOUND FORWARD CABIN STATION 236 RIGHT SIDE L18R HAS CORROSION ON SUB FLOOR WEB. REMOVED DAMAGED SECTION. FABRICATED WEB SECTION AND SPLICE. INSTALLED WEB AND SPLICE. (M)Jul 2, 2003 · N804NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030574Fitting · corrodedFOUND CABIN FS 1309 FRAME TO FLOORBEAM ATTACH FITTING CORRODED AND FAST CORRODED STRINGER 18R. REMOVED OLD FITTING. INSTALLED NEW FITTING. (M)Jul 2, 2003 · N804NK · Doug DC982 · Fuselage Main, Attach FittingsSDR AALA20030710Socket · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AFT EMERGENCY EXIT LIGHT AT SEAT 7D INOPERATIVE. REPLACED AFT EMERGENCY EXIT LIGHT SOCKET AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 2, 2003 · N491AA · Doug DC982 · Emergency LightingSDR ASAA0380519Engine · failedLAX - A LOUD BANG AND VIBRATION FROM RT ENGINE CLIMB AT FL24500 OUT OF LAX. SUSPECT COMPRESSOR STALL. DECLARED EMERGENCY AND RETURNED TO LAX. ENGINE WAS REPLACED. SUBSEQUENT ENGINE TEARDOWN REVEALED A COMPLETE FAILURE OF THE T-3 AND T-4 STAGES, AND THIS FAJul 1, 2003 · N953AS · Doug DC982 · Engine (Turbine/Turboprop)SDR GTIA030589Angle · corrodedFTW - FOUND COCKPIT FLOORBOARD FS 120-160 LEFT ATTACHED SYN ANGLE CRACKED, CORRODED AND DIRTY. REMOVED CRACKED ANGLE. FORMED NEW ANGLE. FABRICATED NEW FLOORBOARD. INSTALLED NEW ANGLE. (M)Jul 1, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030583Angle · brokenFTW - FOUND RIGHT COCKPIT FLOORBOARD ATTACHED SYNTHETIC ANGLE BROKEN, HEAVY FOOD/DIRTY DEPOSITS. REMOVED SYNETHETIC ANGLE. FORMED NEW ANGLE. INSTALLED NEW ANGLE. (M)Jul 1, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030579Floorboard · corrodedFTW - FOUND MAIN CABIN STATION 256 TO STATION 313 RBL 22 TO RBL 45 FLOORBOARD HAS CORROSION AND PUNCTURE HOLES AT BACKSIDE R5. FABRICATED NEW FLOORBOARD. (M)Jul 1, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030573Floorboard · delaminatedFOUND CABIN FLOOR BOARD FORWARD R1 DOOR CORRODED INSERTS, BOARD DELAMINATED, EDGE FILL INCOMPLETE. FABRICATED NEW PANEL. (M)Jul 1, 2003 · N804NK · Doug DC982 · Fuselage Floor PanelSDR AALA20030780Socket · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 14D INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT SOCKET AT SEAT 14D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 1, 2003 · N291AA · Doug DC982 · Emergency LightingSDR MWEA030263Frame · crackedFRAME WEB STATION 1463 AT LONGERON 181 IS CRACKED. FABRICATED AND INSTALLED NEW WEB AND DOUBLER.Jul 1, 2003 · N808ME · Doug DC982 · Fuselage Main, FrameSDR GTIA030606Fitting · crackedFTW - FOUND LEFT INBOARD FLAP INBOARD ACTUATOR ATTACH FITTING CRACKED AT MLG TRAP FITTING. REMOVED CRACKED FITTING. INSTALLED NEW FITTING. (M)Jun 30, 2003 · N804NK · Doug DC982 · Trailing Edge Flap ActuatorSDR GTIA030587Frame · corrodedFTW - FOUND RIGHT AFT LAVATORY FLOOR STATION 1338 STRINGER 18 CORRODED. REMOVED 9 HI-LOCKS AND 1 GUSSET. FABRICATED NEW GUSSET. FOUND FRAME AT FS 1338 AND 18R TO BE CORRODED BEYOND LIMITS. FABRICATED NEW FRAME REPAIR SECTION, AND FABRICATED SPLICE SECTION. Jun 30, 2003 · N804NK · Doug DC982 · Fuselage Main, FrameSDR GTIA030585Longeron · corrodedFTW - AFT PIT CORROSION AT FS 1271 LONGERON 26R. FOUND .25 INCH CRACK ON STRAP. FABRICATED REPAIR DOUBLER. (M)Jun 30, 2003 · N804NK · Doug DC982 · Fuselage Main, Longeron/Stringer
Back to Mcdonnell Douglas DC-9-82