SDR MEX2003288

Service difficulty report · Switch · Doug DC982

Difficulty date
July 14, 2003
Submitted
September 2, 2003
Operation
Air carrier
Aircraft
N491SH
Make and model
Doug DC982
Aircraft serial
49150
Part
Switch
Part number
12911211
Condition
Malfunctioned
Location
Anti-Ice Sys
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 215 - HMO-GDL - AIRCRAFT ARRIVED WITH CAPTAIN REPORT 'L ICE PROTECT TEMP HI' LIGHTS TURN ON. DURING TRANSIT CHECK THE THERMOSTAT AND ANTICIPATOR WERE REPLACED IAW MM 36-10-00. AIRCRAFT WAS DISPATCHED AND AIR TURN BACK AS A CONSEQUENCE OF 'L ICE PROTECT TEMP HI' LIGHTS TURN O. THE HI TMEP SENSOR AND ELECTRONIC THERMAL SW WERE SWAPPED. ADDITIONALLY, THE ANTICIPATOR WAS ADJUSTED AND ENGINES WERE STARTED IT AT 1.8 EPR IAW MM 30-10-06/08, 71-00-00, ALL TESTS CORRECT. (M)