Mcdonnell Douglas DC-9-82

Service difficulty reports · 23,866

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC982'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20130111005Apu · failedABQ INFLIGHT LAS-DFW - CREW REPORTED AUXILIARY POWER UNIT FAILED WITH RIGHT GENERATOR ON MEL. EMERGENCY DECLARED FLIGHT DIVERTED ABQ LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RIGHT GENERATOR. SYSTEM GROUND CHECK NORMAL OPERATION.Jan 11, 2013 · N480AA · Doug DC982 · APU Core EngineSDR AALA20130110009Clamp · out of positionDFW - CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMBOUT. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPOSITIONED Y DUCT BOOT AND CLAMP AND REPLACED BOTH TEMP SENSORS. SYSTEJan 10, 2013 · N486AA · Doug DC982 · Air Distribution SystemSDR AALA20130110005Battery · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. RESEATED BATTERIES. OPS CHECK NORMAL.Jan 10, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130110004Battery · not seatedRIGHT CENTER CEILING EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. RESEATED BATTERIES. OPS CHECK NORMAL.Jan 10, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130110003Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30. RESEATED BATTERIES. OPS CHECK NORMAL.Jan 10, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130109021Battery Pack · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. RESEATED BATTERY PACK IN RIGHT AFT LAVATORY. OPS CHECK NORMAL.Jan 9, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130109020Battery Pack · not seatedRIGHT AND CENTER CEILING EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. RESEATED BATTERY PACK I RIGHT AFT LAVATORY. OPS CHECK NORMAL.Jan 9, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130109019Battery Pack · dischargedCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. RESEATED BATTERY PACK IN ROW 29.Jan 9, 2013 · N576AA · Doug DC982 · Emergency LightingSDR AALA20130109016Floorbeam · damagedELONGATED FASTENER HOLE IN UPPER ANGLE OF FLOORBEAM, STATION 617 RIGHT BUTTLINE 50.5, AT NUT PLATE HOLE. INSTALLED REPAIR ANGLE AND FILLER PER SRM 53-05-00 FIGURE 20A (SHEET 1).Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Main, Floor BeamSDR AALA20130109015Cusp Web · damagedHOLE TORN IN CUSP SHEET AT STATION 597 AT RIGHT BUTTLINE 56. INSTALLED DOUBLER ON CUSP PER AARD 53-20-00-16.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130109014Cusp Web · damagedMISDRILLED HOLES IN RIGHT CUSP SHEET INBOARD SIDE OF CUSP BETWEEN STATIONS 237 TO 256. INSTALLED DOUBLER AS PER AARD 53-20-00-16.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130109012Angle · corrodedCORROSION ON RIGHT CUSP ANGLE AT STATIONS 210 TO 220. INSTALLED RIGHT CUSP ANGLE REPAIR SPLICE AT STATION 185 PER SRM 53-05-00 FIGURE 55 AND BOEING DRAWING J060288.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130109010Longeron · crackedLONGERON 3 LEFT CRACKED AT FLANGES STATION 160. REPLACED LONGERON FROM STATIONS 148 TO 188 WITH SPLICE AT STATION 188 PER SRM 53-02-00 FIGURE 18.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20130109009Longeron · crackedLONGERON 2 LEFT, STATION 160 IS CRACKED ON LEFT FLANGE RADIUS FROM FRAME FASTENER. INSTALLED NEW LONGERON WITH SPLICE AT STATION 168 PER SRM 53-02-00 FIGURE 18.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20130109008Cusp Web · corrodedE AND E COMPARTMENT, RIGHT CUSP HAS CORROSION ON LOWER SIDE FROM STATIONS 180 TO 190 AT LONGERON 18 RIGHT. INSTALLED CUSP REPAIR PER AARD 53-20-00-16.Jan 9, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130108006Web · crackedMID CARGO WEBBING IS CRACKED AT STATION 693, LONGERON 28 RIGHT, UNDER INBOARD SIDE OF TIE-DOWN. SPLICED IN NEW WEB SECTION PER AARD 53-10-00-24.Jan 8, 2013 · N496AA · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130108005Web · gougedMID CARGO WEBBING IS GOUGED AT STATION 630, LONGERON 28 RIGHT, UNDER INBOARD SIDE OF TIEDOWN. INSTALLED NEW STRAP PER AARD 51-00-05-1.Jan 8, 2013 · N496AA · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130108002Cusp Web · corrodedLEFT CUSP AT STATION 756 CORRODED. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER AARD 53-20-00-16.Jan 8, 2013 · N33502 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130107026Actuator · malfunctionedORD - CREW REPORTED SLAT DISAGREE LIGHT ILLUMINATED. FLIGHT LANDED ORD WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED BOTH AUTOSLAT ACTUATORS. SYSTEM GROUND CHECK NORMAL OPERATION.Jan 7, 2013 · N483A · Doug DC982 · Leading Edge Slat ActuatorSDR AALA20130107023Actuator · inoperativeDFW - CREW REPORTED THE RIGHT MAIN GEAR DOOR INDICATED UNSAFE AND THE AMBER *GEAR DOOR OPEN* LIGHT REMAINED ILLUMINATED. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RIGHT MAIN LANDING GEAR RETRACT Jan 7, 2013 · N560AA · Doug DC982 · Landing Gear ActuatorSDR AALA20130107025Cusp Web · corrodedE AND E COMPARTMENT, RIGHT CUSP HAS CORROSION ON LOWER SIDE FROM STATIONS 180 TO 190 LONGERON 18 RIGHT. INSTALLED DOUBLER PER AARD 53-20-00-16.Jan 7, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130107024Doubler · corrodedSUBFLOOR FACTORY DOUBLER FROM STATIONS 160 TO 180, RIGHT BUTTLINES 44 TO 57 CORRODED. INSTALLED NEW SUBFLOOR FACTORY DOUBLER PER AARD51-00-05-1 AND BOEING DRAWING 9936534.Jan 7, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130110006Web · corrodedAFT CARGO WEB STATION 1212 AREA HAS SEVERAL AREAS OF CORROSION. INSTALLING DOUBLER IN WEB PER SRM 51-30-05,51-30-02.Jan 6, 2013 · N496AA · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130107003Battery Pack · dischargedTAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR TAIL COMPARTMENT EMERGENCY LIGHTS. OPS CHECK NORMAL.Jan 6, 2013 · N426AA · Doug DC982 · Emergency LightingSDR AALA20130107002Battery Pack · dischargedRIGHT CENTER EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. REPLACED BATTERY PACK FOR RIGHT CENTER EMERGENCY LIGHTS BETWEEN AFT LAVATORIES. OPS CHECK NORMAL.Jan 6, 2013 · N426AA · Doug DC982 · Emergency LightingSDR AALA20130107001Battery Pack · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 3 TO 6 INOPERATIVE. RESEATED BATTERY PACK FOR CEILING EMERGENCY LIGHTS FROM ROWS 3 TO 6. OPS CHECK NORMAL.Jan 6, 2013 · N426AA · Doug DC982 · Emergency LightingSDR WX0A071469Spar · damagedLEFT HORIZONTAL STABILIZER L/E SPAR AT STATION XHS107 UPPER HOLE ELONGATED. REMOVED DAMAGE AND FREEZE PLUG HOLE.Jan 5, 2013 · N887GA · Doug DC982 · Horizontal Stabilizer, Spar/RibSDR WX0A071467Spar · damagedLEFT HORIZONTAL STABILIZER L/E SPAR AT STATION XHS154 UPPER HOLE ELONGATED. REMOVED DAMAGE AND FREEZE PLUG HOLE.Jan 5, 2013 · N887GA · Doug DC982 · Horizontal Stabilizer, Spar/RibSDR AALA20130106003Sense Line · looseMEX - CREW REPORTED TAIL COMPARTMENT OVERHEAT LIGHT ILLUMINATED ON CLIMBOUT. ACCOMPLISHED QRH AND LIGHT WENT OUT. EMERGENCY DECLARED FLIGHT RETURNED MEX LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. TIGHTENED LEFT ENGINE AUGMENTATION VALVE SENSINJan 5, 2013 · N493AA · Doug DC982 · Overheat DetectionSDR AALA20130105011Controller · failedDFW - CREW REPORTED BOTH AUTO PRESSURIZATION CONTROLS FAILED. FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED NUMBERS ONE AND TWO PRESSURE CONTROLLERS. SYSTEM GROUND CHECK NORMAL OPERATION.Jan 5, 2013 · N510AM · Doug DC982 · Cabin Pressure ControllerSDR WX0A071479Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 4, 2013 · N886GA · Doug DC982 · Emergency LightingSDR AALA20130104010Cusp Web · damagedHOLE IN CUSP UNDER NUMBER 6 SEAT TRACK AT STATION 266. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.Jan 4, 2013 · N44503 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130104009Threshold · corrodedHEAVY CORROSION ON FORWARD SERVICE DOOR AFT THRESHOLD AREA, STATION 200, RIGHT BUTTLINE 54. REMOVED DAMAGE AND INSTALLED DOUBLER AND FILLER PER AARD 53-20-00-14.Jan 4, 2013 · N44503 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130104008Web · corrodedCORROSION ON SUBFLOOR AT STATION 198, RIGHT BUTTLINE 55. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.Jan 4, 2013 · N44503 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130104007Skin · crackedSTATION 1437, LEFT SIDE, RIVETS PULLED IN SKIN AND CRACK IN SKIN, JUST BELOW VERTICAL STABILIZER SKATE ANGLE. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 53-01-00 FIGURE 2 SHEET 3 AND AARD 53-30-00-02.Jan 4, 2013 · N496AA · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA20130104003Web · corrodedCORROSION ON SUBFLOOR UNDER G-1 GALLEY DRAIN PAN. CUT OUT DAMAGE AND INSTALLED DOUBLER PER AARD 53-20-00-16.Jan 4, 2013 · N496AA · Doug DC982 · Fuselage Miscellaneous StructureSDR WX0A071480Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 3, 2013 · N894GA · Doug DC982 · Emergency LightingSDR AALA20130103009Wire · brokenORD - CREW REPORTED RIGHT GENERATOR FAILED. STARTED AUXILIARY POWER UNIT PER QRH PROCEDURES. FLIGHT RETURNED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPAIRED BROKEN WIRE AT X1 TERMINAL OF CURRENT TRANSFORMER T1-13. SYSTEM GROUND CHECK Jan 3, 2013 · N7536A · Doug DC982 · Electrical Power System WiringSDR AALA20130103018Stiffener · crackedSTATION 1338, BUTTLINE 0, DOUBLER CRACKED UPPER END OF STIFFENER ABOVE BULKHEAD DOOR. REMOVED DAMAGED STIFFENER AND CLIP AND INSTALLED SERVICEABLE STIFFENER AND CLIP PER AARD 51-00-05-1 AND EA MD80-53-027537.Jan 3, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130103016Cusp Web · corrodedRIGHT CUSP FROM STATIONS 1130 TO 1135 CORRODED. INSTALLED DOUBLER PER AARD 53-20-00-16.Jan 3, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130103014Cargo Track · corrodedAFT CARGO LEFT TIE DOWN TRACK HAS CORROSION AT STATION 1174. INSTALLED NEW LEFT TIE DOWN TRACK FROM STATIONS 1003 TO 1215 PER IPC 25-52-00-03L, SRM 51-30-05 AND SRM 51-30-01.Jan 3, 2013 · N70504 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA20130103010Cusp Web · crackedCUSP CRACKED FROM STATIONS 218 TO 237. REPLACED CUSP PER AARD 51-00-05-01.Jan 3, 2013 · N496AA · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130102002Intercostal · crackedINTERCOSTAL BETWEEN CABIN FLOORBEAMS FROM STATIONS 1287 TO 1309 BUTTLINE 0 CRACKED AT ATTACH HOLES. REMOVED DAMAGED INTERCOSTAL AND INSTALLED SERVICEABLE INTERCOSTAL PER AARD 51-00-05-1.Jan 2, 2013 · N70504 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20130102005Battery · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK INOPERATIVE. RESEATED BATTERIES. OPS CHECK NORMAL.Jan 1, 2013 · N7528A · Doug DC982 · Emergency LightingSDR AALA20130101003Clamp · looseIAD - INFLIGHT DCA-DFW. CREW REPORTED TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINIATED ON CLIMBOUT. EMERGENCY DECLARED FLIGHT DIVERTED IAD LANDED WITHOUT INCIDENT. TIGHTENED CLAMPS TO LEFT AUGMENTATION VALVE. SYSTEM GROUAN CHECK NORMAL OPERATION.Jan 1, 2013 · N492AA · Doug DC982 · Air Distribution SystemSDR AALA20130102004Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 23 TO 27 INOPERATIVE. RESEATED BATTERIES FOR CEILING EMERGENCY LIGHTS FROM ROWS 23 TO 27. OPS CHECK NORMAL.Jan 1, 2013 · N7528A · Doug DC982 · Emergency LightingSDR AALA20130102003Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 13 TO 16 INOPERATIVE. RESEATED BATTERIES FOR CEILING EMERGENCY LIGHTS FROM ROWS 13 TO 16. OPS CHECK NORMAL.Jan 1, 2013 · N7528A · Doug DC982 · Emergency LightingSDR AALA20130102001Battery Pack · dischargedSEAT MOUNTED EMERGENCY LIGHTS FROM ROWS 9 TO 19DEF INOPERATIVE. REPLACED MODULE AND BATTERY PACK AT M10953.Jan 1, 2013 · N7546A · Doug DC982 · Emergency LightingSDR WX0A071466Seat Track · gougedPASSENGER CABIN SEAT TRACK GOUGED AT STA 965 LBL 72. REMOVED DAMAGE, FABRICATED AND INSTALLED.Dec 29, 2012 · N887GA · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A2012122871467Smoke Detector · faultyFLIGHT CREW REPORTED, CARGO DETECTION SYSTEM AUDIBLE ALARM AND MASTER CAUTION/MASTER WARNING ANNUNCIATORS WHILE IN CLIMB COMPLETED. QRH FOLLOWED. NO SIGNS OF FIRE. BOTH BOTTLES USED. MX REMOVED AND REPLACED ALL 4 AFT PIT SMOKE DETECTORS, BOTTLES, VALVES, MDec 28, 2012 · N886GA · Doug DC982 · Smoke Detection
Back to Mcdonnell Douglas DC-9-82