Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM11001426Generator · dischargedTHE 4R AFT JUMPSEAT OXYGEN GENERATOR FOUND DISCHARGED. REPLACED O2 GENERATOR PER M/M.SDR DLM11001415Oven · smokeMID GALLEY OVENS SMELLED LIKE WARM/OVERHEATED PLASTIC AT OVEN VENT. OVEN TEMP 310 DEG AT THAT TIME. TURNED OVENS OFF AND PULLED OVEN C/BS. SMELL DISSIPATED AFTER SECURING OVENS. REMOVED BURNED FOOD FROM BOTTOM OF OVEN, RAN BOTH OVENS AND NO BURNING SMELL NSDR AALA20001169Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM ROW 20 TO ROW 27 ON RIGHT SIDE INOPERATIVE. REPAIRED BROKEN WIRE AT ROW 20. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR 00FDEA00504Fitting · damagedEMPENNAGE, WITH REF TO E1-5510-7-3304 1 PT 2, STEP 9 AND 18, (FIG 3, SHT 6, CIRCLE STEP 6), 6 HOLES (3 PLACES LT, 3 PLACES RT) FOUND WITH EXISTING COUNTERSINK 100 X 0.610 DIAMETER (100 X 0.512 DIAMETER REQ''D). REPAIRED PER EA NR 1-5530-52023.SDR 00FDEA00482Fitting · oversizedEMPENNAGE, WITH REF E1-5510-7-3304 1 PT2 STEP 9 & 18, (FIG 3, SHT 6, CIRCLE STEP 6) 6 HOLES (3 PLACES LT, 3 PLACES RT) FOUND WITH EXISTING COUNTERSINK 100 X 0.610 DIAMETER (100 X 0.512 DIAMETER REQ''D). REPAIRED PER EA 1-5530-52023. STAB - VERT STAB LT AND RTSDR DLM11001325Engine · leakingAIR TURNBACK, NR 1 ENG OIL QTY DROPPED TO 9 ON T/O ATL. REPLACED ENGINE FOR INTERNAL OIL LEAK.SDR DLM11001324Skin · dentedTHE FUSELAGE SKIN WAS FOUND BADLY DENTED AT FS 810 BETWEEN STRINGERS 33 & 34. THE DAMAGE WAS REMOVED WITH A CUTOUT. THE SKIN WAS REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLER AND TRIPLER PER ER/A 377831-14, REV A.SDR DLM11001315Fan · overheatedELECTRICAL SMELL IN FRONT OF TOURIST SECTION TO BUSINESS GALLEY, STRONGER ON RIGHT SIDE. SMELL DISSIPATED WHEN CABIN BUS SWTCHED OFF. INSPECTED SIDEWALL LIGHTING CEILING AREA AND GALLEY. ALSO, CHECKED CARGO COMP, ALL OK. HOWEVER AT CEILING AREA FOUND NR 2 SDR DLM11001253Smoke · detected3R LAV SMOKE DETECTOR INDICATED SMOKE. SMOKE VISIBLE. INSPECTED LAVATORY AND LIGHT BALLASTS IN AREA, RAN ENGINES AND PACKS. UNABLE TO DUPLICATE.SDR DLM11001250Float Switch · failedTANK 3 FUEL PUMPS OFF MESSAGE ON CLIMBOUT - REPLACED BOTH FSC UNITS AND 2L FULL FLOAT SWITCH S1-1393SDR AALA20001096Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT AT SEAT 2G AND 7H INOPERATIVE. REPLACED CONNECTOR AT SEAT 2G. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR DLM11001240Power Supply · failedON PREFLIGHT, EMERGENCY LIGHT TEST FAILED. REPLACED NR 5 POWER SUPPLYSDR AALA20001082Control Panel · defectiveEZE - FLT 900 - DURING FLIGHT, FIRE DET 3 FAIL ALERT ILLUMINATED. ENGINE FIRE AURAL WARNING SOUNDED FOR THREE SECONDS. NR 3 ENGINE SHUTDOWN AND AGENT DISCHARGED. REPLACED LOWER LOOP-B DETECTOR FDCU NR 3 AND FIRE EXTINGUISHER CONTAINER. SYSTEM GROUND CHECK SDR DLM11001233Display · failedF/O FMS MCDU FAILED POM PROC NO HELP. DIVERTED TO PDX - REPLACED F/O MCDU.SDR AALA20001069Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM RIGHT FIRST CLASS TO SEAT 20G INOPERATIVE. REPAIRED WIRE AT SEAT 2D. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001073Pin · installedDFW - FLT 0945 - AFTER TAKEOFF WHEN GEAR HANDLE RAISED, CENTER GEAR LIGHT REMAINED RED. GEAR WAS LOWERED WITH NORMAL PROCEDURES AND INDICATED SAFE. RETURNED AND LANDED WITHOUT INCIDENT. REMOVED CENTER LANDING GEAR PIN THAT WAS STILL INSTALLED. SYSTEM GROUNSDR DLM11001207Controller · failedAT CRUISE ENG-WING-TAIL ANTI ICE SELECTED ON. AFTER APPROX 1 MIN AVIONICS OVRD AND FLOW LT CAME ON AND CABIN PRESSURE WENT FULL CLOSED NR 1 & 3 BLEEDS SHUT OFF. SHUT OFF ANTI ICE AND NR 2 BLEED LOST. AFTER 30 SEC ALL BLEEDS CAME BACK ON WITH AVIONICS OVRDSDR DLM11001204Radio · odorAPPROX 90 MIN INTO FLT AT FL370, A STRONG ODOR IN COCKPIT AND COCKPIT DOOR AREA. SATCOM 1 C/B POPPED AND REMAINED OUT FOR DURATION OF FLT. ODOR DISAPATED AFTER 20-25 MINS. REPLACED SATCOM RADIO FREQ UNIT AND SDU-C/B REMAINS IN. NO ODOR NOTED. A/C OK FOR SDR WRLA20009Transmission · brokenKMIA - EXPERIENCED NR 9 TIRE FAILURE ALERT ON TAKEOFF. AIRCRAFT RETURNED TO DEPARTURE STATION FOR MAINTENANCE. FOUND TRANSMISSION ASSY SET SCREWS BACKED OUT OF WHEEL HUB ASSY. REMOVED AND REPLACED TRANSMISSION ASSY. (X)SDR DLM11001168Engine · surgesAFTER ROTATION NR 3 ENG HAD SEVERAL COMPRESSOR SURGES. PERFORMED IFSD OF NR 3 ENG AND RETURNED TO PDX. REPLACED ENGINE.SDR AALA20000951Light · defectiveDFW - FLT 70 - DURING BOARDING OF PASSENGERS EMERGENCY EXIT ESCAPE PATH LIGHTS ON LEFT SIDE OF FIRST CLASS AND BUSINESS CLASS ILLUMINATED. REPAIRED ESCAPE PATH LIGHTING STRIP AT DOOR L-2 DOOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000930Trunnion · corrodedTUL - FOUND AFT MOUNT HOLE LEFT SIDE TRUNNION CASTING HAS CORROSION. INSTALLED BUSHING PER SRM 53-40-00-00 PAGE 69 LEFT AFT MOUNT HOLE. (M)SDR DLM11001077Transformer · failedEN ROUTE ATL-LGW, HAD AUTOSLAT FAIL, NR 3 OIL PRESS INVALID AND NR 3 HYD QUANTITY INVALID ANNUNCIATED. DIVERTED TO JFK. SWAPPED TRANSFORMER WITH UNIT INSTALLED IN LOCATION T1-187 AFT CARGO LOADING SYSTEM. NR 3 28VAC BUS, OPS NOW NORMAL.SDR DLM11001076Transformer · failedAUTOSLAT FAIL NR 3 OIL PRESS INVALID AND NR 3 HYD QTY INVALID ANNUNCIATED. FOUND TRANSFORMER T1-33 FAILED. SWAPPED WITH AFT CARGO LOADNG TRANSFORMER T1-187, NBR 3 28VAC BUS OPS NORMAL. NOTE: C/B WAS POPPED NR 3 XFER BUS.SDR AALA20000932Casting · corrodedTUL - FOUND FORWARD MOUNT HOLE IN RIGHT CLG CASTING HAS CORROSION. INSTALLED BUSHING PER SRM 53-40-80 PAGE 69 RIGHT SIDE FORWARD MOUNT HOLE CLG. (M)SDR AALA20000931Casting · corrodedTUL - FOUND LEFT SIDE FORWARD MOUNT BOLT HOLE IN CASTING HAS CORROSION. INSTALLED BUSHING PER SRM 53-40-00 PAGE 69 IN LEFT FORWARD MOUNT HOLE. (M)SDR DLM11001042Line · crackedNR 2 HYD SYST EMPTY, LOSS OF FLUID DURING ENG REV ON GROUND. LEAK TRACED TO STOW LINE, CRACKED AT TOP OF HCU HYD LINE END. REPAIRED PIPE SECTION APPROX 20 INCHES LONG AND NEW COULPLING FITTED BY KLM IAW 20-10-01-02. REV CYCLED SEVERAL TIMES AND NO LEAKS FOSDR AALA20000865Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM ROW 6H TO ROW 13H INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP FROM ROW 6H TO ROW 13H. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000866Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT B4 24 DOOR SHORTED. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AT B4 24 DOOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000811Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT AT SEAT 3G INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AT SEAT 3G. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR DLM11000986Connector · looseAFTER T/O GOT UNSAFE GEAR UP INDICATION PROCEEDED WITH GEAR UNSAFE ILLUMINATED WITH GEAR HANDLE UP. CYCLED GEAR IAW WITH PROCEDURE STILL UNSAFE. VISUAL INSPECTION SHOWED ALL GEAR LOCKED. ACCOMPLISHED TROUBLESHOOTING PER SSM 32-61-00, FOUND SW S1-431 (HANDLESDR DLM11000964Battery · dischargedEMERGENCY LIGHTS COCKPIT TEST, FAILS BATTERY 2 LOW. REPLACED U1-206 BATTERY.SDR DLM11000954Chiller · odorCHILLERS IN FWD GALLEY BURNING SMELL AFTER LANDING C/BS PULLED. REPLACED CHILLER, OPS CHECK GOOD.SDR DLM11000937Stringer · crackedSTRINGER 9 ON THE UPPER SURFACE OF THE CENTER WING WAS FOUND WITH A 9 INCH CRACK IN UPPER HORIZONTAL FLANGE OF THE STRINGER BETWEEN LBL 46 & 55. THE STRINGER FORMS THE UPPER CAP OF THE XCW 46.5 BULKHEAD. THE CRACK WAS STOP DRILLED AND REPAIRED WITH ALUMINUM SDR DLM11000910Mask · leakingSECOND OBSERVERS MASK HAS O2 LEAK. REPLACED SAME.SDR DLM11000879Battery · inoperativeON TRIP CHECK FOUND 2L I/B EMERGENCY FLASHLIGHT DOES NOT FLASH AT BATTERY INDICATION. REPLACED 2L I/B EMERGENCY FLASHLIGHT BATTERY, NOW IND OK.SDR DLM11000849Engine · malfunctionedON TAKEOFF FROM PDX, A/C EXPERIENCED 3 ENGINE SURGES FROM THE NR 1 ENGINE. TOWER CONTACTED FLT CREW AND INFORMED THEM OF FLAMES SEEN FROM THE ENGINE. CREW SHUT DOWN NR 1 AND AIR TURNBACK TO PDX. REPLACED ENGINE.SDR DLM11000779Engine · malfunctionedENG NR 2 FADEC FAILED. TWO LEVEL 2 ALERTS: ENG 2 RPM LOW AND SELECT FADEC ALT NR 2 ENG EGT APPEARED HIGH AT 560 DEG. (DIDN''T EXCEED RED-LINE) AND SHUT DOWN ENGINE. COMPLETED FADEC CHECK LIST AND FAULT CLEARED. RESTARTED, ENG NO PROBLEMS.SDR DLM11000741Controller · malfunctionedRT MLG UNSAFE IND WITH GEAR UP ON BOTH SYNOPTIC AND PANEL LIGHT. REPLACED UNIT.SDR 00FDEA00255Fitting · crackedSNRM 531, EDDY CURRENT INSP NR 4 BANJO FITTING CRACKED. SNRM 570 BANJO 4 FITTING LT AFT MID HOLE EXCEED MAX. REWORK HOLE . ** S/D ** R&R PER 55-20-00 FIG 3 VOL 1 & SB MD-11-55-013 & FEDEX EO 1-55-10-7-3304 & EA 4-5530-49623SDR DLM11000714Battery Pack · malfunctionedDURING SERVICE CHECK, FOUND 4 LT EMERGENCY BATTERY PACK MALFUNCTIONING. REPLACED EMERGENCY LIGHT PACK, OPS CHECK NORMAL.SDR DLM11000627Smoke · detectedF/A SMELLED SMOKE IN VICINITY OF ROW 56. LASTED FOR 2-3 MINS ACFT PASSING THRU 3000 FT ON DESCENT. UNABLE TO LOCATE OR DUPLICATE.SDR AALA20000567Light · malfunctionedLGW - FLT 51 - EMERGENCY EXIT ESCAPE PATH LIGHTS AT ROW 20C THROUGH 25C ILLUMINATED MOMENTARILY. CYCLED LIGHTS AT LGW SEVERAL TIMES. UNABLE TO DUPLICATE FAULT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR DLM11000564Light · damagedJUMP SEAT 2R AFT EMER TRACK FLOOR LIGHT DAMAGED. REPLACED LIGHT HOLDER EMER LIGHTS, OPERATION NORMAL.SDR DLM11000558Fmc · malfunctionedNR 1 ENG INDICATIONS FLUCTUATING AT CRUISE FL350. FUEL FLOW N1, N2 EPR ALL FLUCUATING SLIGHTLY BUT NOTICABLE. REPLACED NR 1 FMU PER M/M. LEAKED CHECKED SATISFACTORY, RAN ENGINE PER PFHB, ENGINE TEST NUMBER 3 ALL CHECKS SATISFACTORY.SDR AALA20000406Wire · brokenMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE FLOOR PATH LIGHTS FROM ROW 6H TO ROW 12G ON RIGHT SIDE OF AIRCRAFT INOPERATIVE. REPAIRED WIRE AT SEAT 6H. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000400Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT DOOR L2 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT AT DOOR L2. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR WRLA20008Harness · chafedON 2/29/2000, DURING CLIMB-OUT AFTER DEPARTING OEJN, THE AIRCRAFT HAD AN ENGINE NR 3 LEVEL 3 FIRE ALERT. THE CREW BROUGHT THE ENGINE BACK TO IDLE AND THE ALERT WENT AWAY. STANDARD EMEGENCY PROCEDURES WERE COMPLIED WITH AND THE AIRCRAFT RETURNED TO THE DEPARTSDR WRLA20007Bulkhead · damagedON FEB 21, UPON ARRIVAL AT ATLANTA FOR A SCHEDULED MAINTENANCE CHECK (A-7) DAMAGE WAS DISCOVERED DURING AN INSPECTION OF THE LOWER FORWARD CARGO COMPARTMENT. THE DAMAGE WAS TO THE AFT BULKHEAD STANCHION AT STATION 1119, AND TO THE OTHER ATTACHMENTS OF THE COMSDR 20000417SH021Brake · failedBRAKE ASSY WAS RECEIVED FROM AIR CARRIER ON 2-21-00 FOR REPAIR AND OVERHAUL SERVICE. UPON DIS-ASSEMBLY, IT WAS IDENTIFIED THE AFFECTED BRAKE SUFFERED AN EXTREME CARBON OXIDATION BREAKDOWN ON THE INNER DIAMETER OF THE HEAT SINK. SUBMITTER RECOMMENDATION WOUL
Back to Mcdonnell Douglas MD-11