Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM11010054Fan · damagedLOUD VIBRATION ASSOC ELEC ODOR OCC EVERY 10 - 15MIN IN CRUISE IN O/H NEAR ROW 10. TURNED OFF ECON MODE AND PULLED RECIRC FAN C/BS, NO HELP. PULLED MID GALLEY CHILLER C/BS, NO HELP. ISOLATED FAULT BY TURNING OFF 3 GALLEY BUS. FOUND PAX OUTLET FAN OVER ROW SDR DLM11010043Frame · cutTHE FS 1681 FRAME WAS CUT AT LONG 47R AND THE FRAME SECTION FROM FS 47R TO THE FACTORY SPLICE AT 47L. THE FRAME SECTION WAS REMOVED TO ALLOW ACCESS TO UNDERLYING STRUCTURE. THE FRAME WAS REINSTALLED WITH THE FACTORY SPLICE AT L-47L AND AN IDENTICAL SPLICE ASDR AALA20010023Switch · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT INOPERATIVE. REPLACED LEFT SIDE EMERGENCY EXIT LIGHT SWITCH AT COCKPIT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11010001Oxygen Mask · dischargedFOUND 55AB 02 MASK DROPPED AND DISCHARGED - REPLACED SAMESDR DLM11002492Cowling · damagedON TAXI IN TO GATE GRU THE RED STOP LGT WAS ON AND THE ACFT CONTINUED TO TAXI FOWARD APPROX 10 METERS CAUSING NBR 1 ENG TO STRIKE THE JETWAY DAMAGING THE NOSE COWL-FLT CANCELED IR-0855/21DEC/GRU/2489770 - 1 ENGINE LIPSKIN DAMAGED AT 1200 OCLOCK POSITION SDR DLM11002472Battery · missingIR-1330/18DEC/LAX/ 060558 - FRC-261-02208 LAV 4R SMOKE. DETECTOR BATTERY MISSING. CA-REPLACED DETECTOR BATTERY AT 4R. SMOKE DETETOR TESTS NML. MALF-4T0 POS-CN CTL-C12180302 SKILL-02SDR AALA20002105Wire · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, FLOOR PATH EMERGENCY EXIT LIGHT FROM 2R DOOR THROUGH SEAT 12G INOPERATIVE. REPAIRED FLOOR PATH EMERGENCY EXIT LIGHT WIRING AT 2R DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11002428Switch · intermittentON CLIMBOUT GOT RED REVERSER UNLOCKED MESSAGE FOR NR3 ENGINE. FOUND LOWER RT STOW SWITCH INTERMITTENT. REPLACED SAME.SDR 20010129CW026Actuator · failedAFTER AIRBORNE, RIGHT MAIN LANDING GEAR CAN NOT RETRACT, AIRCRAFT TURNED BACK TO AIRPORT. RIGHT MAIN LANDING GEAR RETRACT ACTUATOR REPLACED.SDR DLM11002312Smoke Detector · malfunctionedLAV SMOKE LIGHT ILLUM DURING DECENT, MOST REAR LT SIDE SHOWED IT WAS COMING FROM THERE. NO SMOKE DETECTED. REPLACED LAV AIR DETECTOR AT R-4 DOOR FWD LAV. PERFORMED GROUND TEST OK.SDR WRLA200014Transmitter · malfunctionedFLAP DISAGREE AT 60 KNOTS. REPAIRED AND REPLACED LEFT OUTBOARD FLAP POSITION TRANSMITTER AND CLEANED CONTACTS. (M)SDR DLM11002246Battery · failedEMERGENCY LIGHT BATTERY 1 LOW DURING TEST. REPLACED BATTERY.SDR DLM11002223Oven · inoperativeGALLEY 1R FWD OVEN INOP. FLT ATTN REPORTS NR 2 OVEN FWD GALLEY TURNS ON/OFF UNCOMMANDED AND HAS ELECTRICAL BURN SMELL. OVEN C/BS PULLED BY FLT CREW. RAN OVEN 2 AND FOUND OVEN MAKES LOUD HUMMING NOISE. ACCOMPANIED BY ELECTRICAL BURN SMELL EMINATING FROM OVESDR DLM11002180B-Nut · failedNR 3 HYD FAILURE ON TAXI IN. FOUND B-NUT LOOSE ON DOWNLOCK ACTUATOR. TIGHTEN NUT AND REMOVED 4 ENG FILTERS, FOUND ALL 4 CLEAN. RE-INSTALLED NEW FILTERS AND MOTORED ENG. LEAK CK OK. RAN ENG AT IDLE AND CHECKED THAT PUMPS SWITCHED OVER AND ARMED. SERVICEDSDR WRLA200013Autopilot Sys · inoperativeBOTH FCC FAULTED, AUTO PILOT INOP AFTER TAKEOFF. RETURN TO SERVICE ON AP1, AP2, FCC1 AND FCC2. ALL RETURN TO SERVICE TEST PASSED.SDR DLM11002143Power Supply · failedDURING PREFLIGHT FOUND EMERG LIGHT BAT1 LOW MSG DURING TEST. REPLACED PWR SUPPLY AND BATTERY.SDR DLM11002133Engine · stalledCOMPRESSOR STALL AT 60 KNOTS ON T/O NR 1 ENGINE. PERFORMED FIM TEST 71-01-05, PARAMETERS WITHIN LIMITS.SDR DLM11002034Control Unit · failedON APPROACH NR 3 ENGINE FIRE WARNING ILLUM. PUSHED MAST WRN UNABLE TO SILENCE BELL. MASTER WRN EXT, ENG SHUTDOWN IAW POM FIRE WRN DID NOT EXT. LIGHT IN T-HANDLE, FUEL C/O SW, AND LVL 3 ALERT REMAINED ON. COULD NOT GET AGENT LOW LIGHTS WHEN T-HANDLE ROTATEDSDR DLM11002009Light · inoperativeEMERGENCY LIGHT AFT OF 2R DOOR INOP. RELAMPED.SDR DLM11001989Control Panel · failedMULTIPLE COMMUNICATION SYSTEMS FAILURE. DIVERT TO PDX. REPLACED OBSERVER''S AUDIO CONTROL PANEL.SDR AALA20001688Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, LEFT EMERGENCY EXIT FLOOR PATH LIGHTING AT SEAT 27 TO 34 INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING AT SEAT 27 TO 34. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11002039Relay · failedDURING POWER TRANSFER CREW REPORTED A UNCOMMANDED DEPLOYMENT OF THE PASSENGER OXYGEN MASKS. MTC CHECKED SYSTEM VIA M/M AND REPLACED RELAYS R2-253 AND R2-106.SDR DLM11001959Actuator · looseSHIMS MIGRATING NR 12 SPOILER ACTUATOR ILB LWR ATTACH BOLT. REPLACED SHIMS AND C/W MM 57-42-0 PG 804.SDR DLM11001964Bottle · dischargedFOUR HOURS INTO FLIGHT, ENGINE FIRE AGENT LOW LIGHT ENG 1 WARNING CAME ON. REPLACED NR 1 ENGINE NR 1 FIRE BOTTLE. SQUIB NOT FIRED. SUSPECT AGENT LEAKED OUT AS SOME AGENT STILL PRESENT IN BOTTLE.SDR DLM11002169Engine · stalledAT 180 KTS 200 FT AGL NR 1 ENG EXPERIENCED A COMPRESSOR STALL, EDR SHOWED NO SURGE OR FADEC FAULTS. ENGINE STALLED AGAIN ON GROUND TEST AT 1.4 EPR. REPLACED ENGINE.SDR DLM11001926Generator · activatedDURING CABIN CLEANING, 5 PSU DEPLOYED OXYGEN MASKS WITH 2 OXYGEN GENERATORS ACTIVATED. REPLACED OXYGEN GENERATORS AND RESTOWED MASKS. SUSPECT CABIN SERVICE BUMPED PANELS WHILE CLEANING.SDR DLM11001921Megaphone · failedFWD MEGAPHONE INOP. REPLACED BATTERIES.SDR DLM11001920Bottle · dischargedL-1 DOOR ASSIST BOTTLE DEPLETED. RESET ACTUATOR CAM AND SERVICED PER M/M.SDR DLM11001877Light · shortedDURING PREFLIGHT CHECK, SMOKE SPARKS CAME FROM OVERHD BIN AT SEAT 4H-J. DEACTIVATED CABIN BUS FROM COCKPIT. SMOKE SPARKS CEASED. FOUND CONNECTOR FOR 40 INCH SIDEWALL LIGHTS MODULE BURNT. PLUG NR 0200525-011. REPLACED SAME.SDR WRLA200012Seal · dislodgedON TAKEOFF ROLL AT APPROXIMATELY 120-125 KNOTS AN AIRFLOW NOISE WAS HEARD IN THE COCKPIT IN THE VICINITY OF THE PEDESTAL AND CENTER INSTRUMENT PANEL ACCOMPANIED BY A MASTER CAUTION LIGHT AND A LEVEL 2 CARGO DOOR ALERT. TAKEOFF WAS ABORTED AT 140 KNOTS AND THESDR DLM11001863Unknown · odorSTRONG ODOR DETECTED IN AFT GALLEY AREA. REMOVED CARGO AND THOROUGHLY INSPECTED AIRCRAFT. UNABLE TO DUPLICATE.SDR DLM11001853Computer · malfunctionedAT TOP OF CLIMB GOT NR 2 MANIFOLD FAILURE. SYSTEM RESOLVED ITSELF. FOUND MANIFOLD FAIL COMPUTER BAD. REPLACED SAME.SDR DLM11001846Smoke · detectedSEAT 01H CALL LIGHT AND VIDEO INOP. PASSENGER REPORTED BRIEF ELEC SMOKE ODOR. MTC UNABLE TO DUPLICATE OR FIND FAULT WITH SYSTEM OPERATION.SDR DLM11001774Megaphone · inoperativeNO SOUND FROM AFT CABIN MEGAPHONE WHEN TESTED. REPLACED MEGAPHONE.SDR DLM11001768Latch · stuckL-2 STU SEAT OXYGEN DOOR DID NOT OPEN ON TEST. REPLACED LATCH MECHANISM ON L-2 FWD FLIGHT ATTENDANT SEAT OXYGEN DOOR. CHECKS GOOD PER AMM 35-21-07-5.SDR DLM11001767Latch · failedFIRST CLASS RT CTR STU SEAT OXYGEN DOOR DID NOT OPEN ON TEST. RESET LATCH MECHANISM ON FWD CABIN RIGHT CENTER ATTENDANT SEAT OXYGEN DOOR. CHECKS GOOD PER AMM 35-21-07-5.SDR AALA20001473Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS FORWARD OF SEAT 34C INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11001668Wire · damagedDURING MTC CVG FOUND DAMAGED GALLEY AND EXTERNAL FEEDER WIRE. ALL DAMAGE WAS FOUND UNDER METAL CLAMPS. REPLACED CABLES.SDR DLM11001649Switch · out of adjNR 3 U/L ILLUMINATED AIRBORNE STAYED ON UNTIL DESCENT FOR LANDING, EXTINGUISHED LAST 15 MIN OF FLIGHT. ADJUSTED STOW SWITCHES.SDR DLM11001572Unknown · odorBRIEF ELEC SMELL IN COCKPIT ONLY, DID NOT REOCCUR. CHECKED WIRING BEHIND CIRCUIT BREAKER PANELS, RAN AC PACKS AND NO DISCREPANCIES NOTED.SDR WRLA20011Bullet · delaminatedUPON DEPARTURE, AIRCRAFT EXPERIENCED ENGINE VIBRATION OF UNKNOWN ORIGIN IN NR 1 POSITION. EMERG PROCEDURES C/W, AND ACFT RETURNED TO DEPARTURE STA WITHOUT INCIDENT. UPON INSP BY WORLD AIRWAY MAINT REP, DISCOVERED THE NOSE CONE (SPINNER) ON NR 1 ENGINE HAD DESDR DLM11001558Connector · damagedAIRCRAFT ARRIVED WITH MCO NR 007341002 TAIL LEFT PUMP OFF LIGHT ILLUMINATED IN FLIGHT (TRANSFER PUMP. FOUND RECEPTACLE IN PUMP HOUSING WITH BURNED PINS AND WIRING. THE RECEPTACLE SMELLED OF FUEL BUT NO EVIDENCE OF A FUEL LEAK WAS NOTED. REPLACED HOUSING P/NSDR AALA20001331Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTING IN FIRST CLASS CABIN INOPERATIVE. REPLACED LIGHT STRIP. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR WRLA20010Antenna · failedWEATHER RADAR SYSTEM NR 1 FAILED FOUR MINUTES AFTER TAKEOFF. SYSTEM NR 2 FAILED 16 MINUTES INTO FLIGHT. AIRCRAFT DIVERTED TO BRU WHERE ANTENNA WAS REPLACED. OPERATIONAL TEST OK AFTER ANTENNA CHANGE. (X)SDR DLM11001500Skin · puncturedTHE FUSELAGE SKIN WAS PUNCTURED BY GROUND EQUIPMENT BETWEEN FS 640 & 650 AT STRINGER 38R. THE DAMAGED SECTION OF SKIN WAS REMOVED WITH A 6.5 X 7.5 INCH CUTOUT AND THE DAMAGED SECTION OF STRINGER REMOVED. THE STRINGER WAS REPAIRED PER THE MD-11 SRM AND THE SKSDR DLM11001465Battery · failedEMERGENCY LIGHT BATTERY 5 LOW ALERT ON EAD DURING EMERGENCY LIGHT TEST. REPLACED NR 5 POWER SUPPLY AND NR 4.SDR DLM11001461Battery · failedEMERGENCY LIGHTS STUCK ON ROWS 43 THRU 49. INSTALLED NEW BATTERY PACK. EMERGENCY LIGHT OPERATION NOW NORMAL.SDR DLM11001451Seal · leakingLAST 10 MIN OF FLT, OIL QTY WENT TO 0 OIL PRESS, REMAINED ABOVE MINIMUM. FOUND 2 ENG FWD HYD PUMP GARLOCK SEAL LEAKING. REPLACED SEAL AND REMOVED PUMP PER MEL 29-11-01A. RAN ENGINE, LEAK CHECKS GOOD.SDR DLM11001433Wire · chafedEMERGENCY LIGHTS FROM ROW 30 TO 41 INOP. REPAIRED CHAFED WIRE AT TERMINAL STRIP IN OVERHEAD LIGHTS, TEST OK.SDR DLM11001431Arm · looseHYD 3 FAIL ON FINAL WHEN GEAR EXTENDED. ALL NR 3 SYSTEM LOST. FOUND QTY TRANSMITTER ARM LOOSE. REPAIRED SAME.
Back to Mcdonnell Douglas MD-11