Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WRLA99014Valve · leakingDURING INITIAL CLIMB-OUT ON FLT NR MH6203, FLIGHT CREW NOTED NR 3 HYD 'OFF' LIGHT ILLUMINATED, AND LOSS OF HYDRAULIC FLUID IN NR 3 SYSTEM TO 4.8 GAL. NR 3 SYSTEM WAS SHUT DOWN. FLIGHT CREW CONTACTED MAINTENANCE CONTROL, AND BASED UPONITS RECOMMENDATION, FLIGSDR AALA990405Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT ROW 15G WERE INOPERATIVE. REPLACED EMERGENCY FLOOR PATH LIGHT STRIP AT SEAT ROW 15G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990404Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT ROW 20G WERE INOPERATIVE. REPLACED EMERGENCY FLOOR PATH LIGHT STRIP AT SEAT ROW 20G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990403Wire · looseDFW - DURING OVERNIGHT MAINTENANCE, DOOR MOUNTED EMERGENCY EXIT IDENTIFIER AT R2 DOOR IS INOPERATIVE. RESEATED DOOR MOUNTED EMERGENCY EXIT IDENTIFIER TERMINAL WIRE AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11990556Projector · failedMIDWAY DURING FLT STRONG ELEC FUMES WERE DETECTED FROM THE FWD Y CLASS CABIN, PROJECTOR APPEARS TO HAVE OVERHEATED. PULLED C/BS FOR VIDEO SYSTEM AND FUMES APPEARED TO DISSIPATE AFTER VIDEO PROJECTOR WAS SHUTDOWN. REMOVED CEILING PANELS THROUGHT CABIN, INSPECSDR 99ZZZX1373T/R Unit · brokenPILOT ABORTED TAKEOFF DUE TO HEARING THE WARNING AND 'STABILIZER' MESSAGE APPEARED DURING TAKEOFF IN ANC. CAUSED THE RT T/R COWLING TO BREAK. ZVA SENT ONE SERVICEABLE RT T/R COWLING TO ANC FOR REPLACING ON 3-12-99.SDR AALA990303Wire · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT AT 2R DOOR HAS ONE BULB INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH FLAT WIRE AT 2R DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR WRLA99013Dme · overheatedFLT 5129 - DURING CRUISE, FLIGHT CREW NOTED LIGHT SMOKE AND BURNING ELECTRICAL SMELL IN COCKPIT. ADDITIONALLY, NR 2 DME CIRCUIT BREAKER POPPED. SMOKE APPEARED IN VICINITY OF CAPTAIN'S OVERHEAD MAP LIGHT. NON-ESSENTIAL OVERHEAD LIGHTING WAS SWITCHED OFF. DMSDR DLM11990377Seal · failedLOUD VIBRATION UNDER COCKPIT AFTER T/O. FOUND SEAL ON FWD WHEEL WELL TO E/E ACCESS DOOR OUT OF RETAINER AT LT UPPER CORNER AND RT LWR CORNER. REPLACED SAME.SDR AALA990276Wire · chafedORD - FLT 0154 - DURING OVERNIGHT MAINTENANCE, AIRCRAFT WOULD NOT ACCEPT ELECTRICAL POWER OF ANY KIND. FOUND WIRE BURNED AND SHORTED IN THE FORWARD CARGO BAY LEFT SIDE JUST AFT OF DOOR OPENING. MAINTENANCE REPLACED AND REPAIRED WIRING ACCORDING TO ESTABLISHESDR AALA990265Fan · defectiveANC - FLT 157 - EN ROUTE DFW-KIX - CREW NOTED AN ELECTRICAL SMELL IN CABIN CABIN. CREW DECLARED AN EMERGENCY AND AIR INTERRUPTED. LANDED ANC WITHOUT INCIDENT. REPLACED NR 2 RECIRCULATING FAN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11990342Bulb · failedEMERGENCY LIGHTS AT 10 JH WILL NOT ILLUMINATE. REPLACED BULBS, OPS CK NORMAL.SDR DLM11990297Wire · shortedON GROUND IN LGW, ELECTRICAL SMELL PRESENT AT ROW 13 OF PASSENGER CABIN. FOUND SEAT 13A VIDEO MONITOR HARNESS SHORTED OUT IN SEAT 13A. FLT CREW VERBAL REPORT. DEACTIVATED SEAT 13A AT LGW. REPLACED HARNESS ASSY AND VIDEO MONITOR AT 13A AND INSPECTED HARNESSSDR AALA990135Control Unit · defectiveSEA - FLT 27 - DURING CRUISE A LOUD BUSS HEAD OVER COCKPIT SPEAKER AND WAS SILENCED BY PUSHING THE PA SELECTOR. NR 1 FLT ATTENDANT REPORTED SMOKE FROM THE VIDEO SYSTEM. 1ST OFFICER INVESTIGATED AND DISHARGED THE HALON FIRE EXTINGUISHER INTO THE AREA. C/B'S SDR WRLA99010Engine · malfunctionedDURING INITIAL CLIMB AFTER TAKEOFF ON FLIGHT NR WOA972, FLIGHT CREW RECEIVED NOTIFICATION FROM AIRPORT TOWER THAT 'TWO FIREBALLS' WERE NOTED EXITING FROM THE NR 1 ENGINE DURING DEPARTURE. FLIGHT CREW NOTED THAT ALL ENGINES PARAMETERS WERE NORMAL. FLIGHT CREWSDR 99ZZZX545Channel · brokenCENTER CARGO COMPARTMENT, FS 1701 - FS 1802, BL 30 - BL 36, RT CHANNEL ASSY, BROKEN. REMOVED AND REPLACED CHANNEL IAW MD 11 SRM'S 51-31-01, 51-21-02, 51-41-01, 50-90-02.SDR AALA990014Wire · chafedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING WAS INOPERATIVE BETWEEN 3R AND 4R DOORS. FOUND EMERGENCY EXIT FLOOR PATH LIGHT WIRE SHORTED. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT WIRE AT SIDEWALL AFT OF R-3 LAVATORY. SYSTEM GROUND SDR AALA990018Wire · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT ROW 21C INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH FLAT JUMPER WIRE AT SEAT ROW 21C. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990017Wire · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT ROW 20C INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH FLAT JUMPER WIRE AT SEAT ROW 20C. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 98FDEA00767Coalescer Bag · contaminatedAFT T/O AC FILLED WITH SMOKE. EMER DECLARED. REMOVED AND REPLACED COALESCER BAGS IN ALL THREE AIR COND PACK SYS PER MM 21-54-05 LEAK CKD GOOD. RAN PACKS USING APU AND ENG AIR PER MD11 JRD, NO SMOKE PRESENT. A/C OK FOR SERVICE.SDR DLM11982631Battery · dischargedFWD CABIN EMERGENCY LIGHT INOP. REMOVED AND REPLACED N01 BATTERY PACK IN THE NR 1 BATTERY POWER SUPPLY, GRD OPS CK OK.SDR DLM11982624Air Dist · odorELEC SMOKE SMELL IN COCKPIT. VERIFIED BY FLIGHT ATTENDANTS AS THEY WALKED UP TO COCKPIT. RAN ENGINES AT POWER FOR 30 MIN. PRESSURIZED AIRCRAFT OPERATED ALL GALLEY EQUIPMENT, CKD AFT GALLEY FEEDER CABLES AND GALLEY GCU'S FOR SECURITY. REPLACED OVEN 108 AND SDR AALA982221Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AT SEAT ROWS 13G AND 14G INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT SEAT ROW 13G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 99ZZZX257Mfdu · failedALERT MESSAGE 'NR 2 AIR MANIFOLD FAIL' DURING IN-FLIGHT AND DIVERTED TO CTS. PER MEL 32-23-1 RELEASE A/C. REPLACED MANIFOLD FAULT DETENTION CONTROLLER (NFDC) AND GROUND CHECK NORMAL.SDR AALA982154Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING FORWARD OF R2 DOOR HAS 3 LIGHT SEGMENTS INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIPS AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA982142Bulkhead Angle · corrodedTUL - FOUND CORROSION ON LOWER PRESSURE BULKHEAD TEE ANGLE ON BOTH SIDES OF SEAT TRACK NR 8. REMOVED OUT OF LIMITS SECTION AT TEE ANGLE FABRICATED NEW SECTION. INSTALLED WET WITH PR1436 SEALANT WITH RIVETS, HI-LOCKS, AND SPLICE 53-40-00-0. (M)SDR 99ZZZX246Air Distribution · smokePILOT REPORTED AT LIFT-OFF SMOKE WAS NOTICED FROM THE GALLEY AREA, CAUSED AIR-TURNBACK. MAINTENANCE RAN ALL THREE ENGINES AT HIGH POWER WITH GALLEY POWER OFF, THEN ON BLEED CHECK. NO INDICATION OF SMOKE, FOG. CHECKED GALLEY AREA, NO SMOKE FOUND. AIRCRAFT RSDR DLM11982443Battery Pack · dischargedEMERG PATH LIGHTS OUT ROW 30 TO 38 LT AND RT SIDE. REPLACED BATTERY CHARGER AND BATTERY PACK, CKS OK.SDR DLM11982418Skin · puncturedTHE FUSELAGE SKIN WAS PUNCTURED AND GOUGED BETWEEN FS 1850 AND 1960, BETWEEN STRINGERS 48L AND 48R DUE TO A TAIL STRIKE. THE DAMAGED SECTION OF SKIN WAS REMOVED BETWEEN THE EXISTING SKIN SPLICES AT 48L AND 48R AND A NEW SECTION OF SKIN WAS SPLICED IN WITH A NSDR AALA982117Terminal · defectiveDFW - FLT 60 - EN ROUTE NRT-DFW, DURING CRUISE EMERGENCY LIGHTS E8 CIRCUIT BREAKER ON OVERHEAD PANEL POPPED. RESET OF CIRCUIT BREAKER FAILED. LANDED DFW WITHOUT INCIDENT. REPLACED 3-707 TERMINAL AND BURNDY BLOCKS 2 AND 3. SYSTEM GROUND CHECKED NORMAL OPERASDR DLM11982381Chiller · failedAFT GALLEY CHILLER OVERHEATED CAUSING STRONG ELECTRICAL SMELL. CHILLERS SHUTOFF AND SMELL WENT AWAY. C/B FOR CHILLER PULLED AND COLLARD, REPLACED G8 GALLEY CHILLER.SDR DLM11982294Control Unit · failedDURING TRIP CHECK, SMOKE AND FUMES SMELLED BY MTC AT SEAT 12A. FOUND SHORTED WIRE TO CARGO ROLLER IN FWD CARGO CAUSED FIRE IN CONTROLLER UNIT WHICH IGNITED MYLAR INSULATION BLANKET. REPLACED CONTROLLER UNIT, WIRING AND INSULATION BLANKET.SDR AALA982033Wire · brokenORD - DURING OVERNIGHT MAINTENANCE, R1 DOOR EMERGENCY EXIT SPOT/SIGN WOULD NOT ILLUMINATE. REPAIRED BROKEN WIRE R1 DOOR EMERGENCY EXIT SPOT/SIGN LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR WRLA98096Hubcap · damagedDURING TAKEOFF ROLL OF FLIGHT NR WO-826, FLIGHT CREW RECEIVED A 'TIRE FAILURE' INDICATION ON SYSTEMS DISPLAY. FLIGHT CREW ELECTED TO DISCONTINUE TAKEOFF (MAX SPEED ATTAINED 90 KNOTS). TAKEOFF WAS DISCONTINUED, AND AIRCRAFT RETURNED TO GATE WITHOUT FURTHER INSDR WRLA98097Fcu · inoperativeDURING INITIAL TAKEOFF ROLL, FLIGHT CREW RECEIVED TANK 2 PUMPS 'OFF' ALERT. FLIGHT CREW ELECTED TO RETURN TO GATE. AIRCRAFT RETURNED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL INOP FUEL SYSTEM CONTROL AUTO MODE. DEFERRED PER MEL 28-01-1. AIRCSDR AALA981997Angle · corrodedTUL - T-ANGLE CORRODED UNDER NR 2 GALLEY MOUNT AT STATION 2007. REMOVED AND REPLACED T-ANGLE PER AARD 51-10-00-00-1. (M)SDR AALA982007Seat Track · corrodedTUL - NR 2 SEAT TRACK CORRODED AT STATION 1385. REPAIRED PER SRM 53-70-00-0 VOL 1. (M)SDR AALA981930Transmitter · failedDFW - FLT 2248 - DURING CLIMB-OUT, FLAPS WERE FULLY RETRACTED AND THE RIGHT OUTBOARD FLAP INDICATED 6 DEGREES EXTENSION. AIRCRAFT AIR INTERRUPTED AND LANDED DFW WITHOUT FURTHER INCIDENT. FOUND RIGHT OUTBOARD FLAP TRANSMITTER FAULTY. REPLACED RIGHT OUTBOARD SDR AALA981919Support · corrodedTUL - FOUND CORROSION ON GALLEY SUPPORT AND LUGS. REPLACED AFT GALLEY SUPPORT PER AARD 53-00-10 AND SRM 53-70-00. (M)SDR AALA981918Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK NR 8 AT STATION 1964. CUT OUT CORRODED SECTION OF SEAT TRACK AND SPLICED IN NEW SECTION IAW SRM 53-70-00-0. (M)SDR AALA981899Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK UNDER LAVATORY. REPLACED SECTION OF SEAT TRACK PER AARD 51-10-00-01 AND 53-70-00 OF THE SRM VOL 1. (M)SDR AALA981902Stringer · crackedTUL - RIGHT WING STRINGER NR 10 IS CRACKED AT THE OUTBOARD END. REMOVED CRACKED STRINGERS END AND SPLICED IN NEW SECTION PER SRM 57-20-00-0 VOL 1. (M)SDR 98FDEA00648Seal · out of positionAFTER T/O, HIGH PITCH NOISE FROM UNDER COCKPIT. THE CABIN OUTFLOW WAS CLOSED AND AVIONIC FAN OVERRIDE CAME ON. A/C WOULDN'T PRESS AND CLIMB STOP AT 10,000 FT, DUMP FUEL AND RETURNED. T/S FOUND WINDSHIELD WIPER MTR ASSY PANEL SEAL OUT OF POSITION. REPOSITIOSDR AALA981901unknownTUL - FOUND CORROSION ON TOE OR 'T' ANGLE AROUND MOUNTING BOLT HOLES FOR LT AFT GALLEY SUPPORT. REMOVED AND REPLACED T-ANGLE PER 51-10-00-1 AARD. (M)SDR AALA981900Angle · corrodedTUL - FOUND CORROSION ON FLOOR ANGLE INBOARD OF NR 6 SEAT TRACK. REMOVED AND REPLACED T-ANGLE PER AARD 51-10-00-1. (M)SDR DLM11982096Compressor · seizedAIRCRAFT DIVERTED INTO SNN WITH SMELL OF BURNING IN CABIN. IRISH AUTHORITIES REMOVED FDR AND CVR FOR ELAVUATION. AIRCRAF STILL IN SNN 100998 UNDER INVESTIGATION. NR 1 WATER SYS AIR COMP FAILED, BURNED WIRING TO COMPRESSOR.SDR DLM11982042Smoke Alert · activatedLAV SMOKE ALERT APPEARED FOR 10 MINS, RT SIDE BUSINESS CLASS LAV AND LT SIDE BUSINESS CLASS LAV. RED ANNUN LIGHTS CAME ON FOR BOTH LAVS. LAV SMOKE DETECTORS CHECKED, NO FAULTS FOUND.SDR WRLA98094Stanchion · crackedDURING C-CHECK, FORWARD BAGGAGE COMPARTMENT AFT BULKHEAD CENTER PANEL, LOWER ATTACH ANGLE WAS CRACKED/BROKEN. MAINTENANCE PERSONNEL REPLACED T-EXTRUSION (STANCHION) PER SRM 53-40-0, PAGE 4, FIG 6. (X)SDR WRLA98093Panel · chafedDURING C-CHECK, LOWER VERTICAL STABILIZER FIRE SEAL PANEL WAS FOUND CHAFED AND WORN THOUGH THE OUTER EDGE. MAINTENANCE PERSONNEL REPAIRED VIA WELDING PER DOUGLAS PROCESS SPECIFICATION. (X)SDR WRLA98092Balance Weight · corrodedDURING C-CHECK, RIGHT-HAND, OUTBOARD AILERON WAS IDENTIFIED AS HAVING CORROSION ON BALANCE WEIGHTS. MAINTENANCE PERSONNEL REMOVED CORROSION ON NR 3 AND NR 4 WEIGHTS PER SRM 51-82-00. NR 2 WEIGHT BEYOND SRM LIMITS. REPLACED WEIGHT WITH NEW PART. (X)
Back to Mcdonnell Douglas MD-11