SDR WRLA99014

Service difficulty report · Valve · Doug MD11

Difficulty date
March 18, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N275WA
Make and model
Doug MD11
Aircraft serial
48631
Part
Valve
Part number
1489951
Condition
Leaking
Location
Nr 3 Hyd System
Stage of operation
CL
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING INITIAL CLIMB-OUT ON FLT NR MH6203, FLIGHT CREW NOTED NR 3 HYD 'OFF' LIGHT ILLUMINATED, AND LOSS OF HYDRAULIC FLUID IN NR 3 SYSTEM TO 4.8 GAL. NR 3 SYSTEM WAS SHUT DOWN. FLIGHT CREW CONTACTED MAINTENANCE CONTROL, AND BASED UPONITS RECOMMENDATION, FLIGHT CREW ELECTED TO RETURN TO POINT OF DEPARTURE FOR MAINTENANCE ACTION. AIRCRAFT RETURNED TO AIRPORT OF DEPARTURE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL FOUND NR 3 HYD SYSTEM REVERSIBLE MOTOR PUMP SHUTOFF VALVE LEAKING. SHUTOFF VALVE WAS REPLACED. SYSTEM WAS RESERVICED. OPERATIONAL CHECK COMPLETED WITHOUT MALFUNCTION. AIRCRAFT WAS RETURNED TO SERVICE. AIRCRAFT WAS OUT OF SERVICE FOR 5 HOURS 30 MINUTES. (M)