Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA961761Support · corrodedTUL - FLOOR BOARD SUPPORT INBOARD OF NR 2 GALLEY SUPPORT HAS CORRODED. INSTALLED A NEWLY MANUFACTURED FLOOR BOARD SUPPORT JUST INBOARD OF THE NR 2 GALLEY SUPPORT. DATE, 12-4-96, PER SRM 53-00-01-0, VOL I. TST: 16,385 HOURS. CYCLES, 2,173. (X)SDR AALA961754Seat Track · corrodedTUL - NR 8 SEAT TRACK CORRODED AT STA 1315. REMOVED CORROSION, INSTALLED SEAT TRACK PLUG PER SRM 53-70-00, VOL I. TST: 16,385. CYCLES, 2,173. (X)SDR AALA961753Seat Track · corrodedTUL - NR 7 SEAT TRACK CORRODED AT STA 1351. REMOVED CORROSION, INSTALLED SEAT TRACK PLUG PER SRM 53-70-00. TST: 16,385. CYCLES, 2,173. (X)SDR WRLA96052Bolt · leakingDURING TAXI-OUT, PASSENGER REPORTED FUEL SEEPING FROM TOP OF RIGHT WING. FLIGHT CREW ELECTED TO RETURN TO GATE FOR MAINTENANCE. AIRCRAFT RETURNED TO GATE WITHOUT INCIDENT. MAINTENANCE PERSONNEL FOUND BOLT TO NR 3 FUEL TANK MULTI-JUNCTION PROBE WAS SEEPING. SDR DLM11962583Engine · malfunctionedNR 3 ENGINE SURGED ON T/O AND EGT WENT TO 710 DEGREES. ENG PARAMETERS RETURNED TO NORMAL AFTER POWER REDUCTION. AIRCRAFT FERRIED TO ATL FOR ENGINE CHANGE.SDR DLM11962581Battery · dischargedEMERGENCY LIGHT SYSTEM FAULTED BATTERY PACK NR 3 AND NR 6.SDR DLM11962580Battery · dischargedEMERGENCY LIGHT SYSTEM FAULTS BATTERY PACK NR 3 AND NR 6.SDR DLM11962541Wire · brokenA/C LOST ELECTRICAL POWER AT GATE WITH PASSENGERS ON BOARD. RIGHT SIDE EMERGENCY LIGHTS AT ROW 30 TO 36 FLOOR LIGHTS INOPERATIVE. REPAIRED BROKEN WIRE FOUND IN FLOOR TRACK WIRING.SDR AALA961699Seat Track · corrodedTUL - DURING C-CHECK, FOUND CORROSION ON NR 1 SEAT TRACK UNDER LAVATORY 'H' IN AFT CABIN BETWEEN STA 1961 AND STA 1964. CUT OUT CORROSION AND INSTALLED SEAT TRACK REPAIR PER SRM 53-70-00, PAGES 8 AND 9, AND ESO 41000 DATED 11-18-96. TST: 16,324.30 HOURS. CSDR AALA961698Tie Down · corrodedTUL - NR 2 GALLEY CENTER SUPPORT TIE DOWN HAD CORROSION AROUND AFT END. INSTALLED A NEW NR 2 GALLEY CENTER SUPPORT TIE DOWN PER SRM 53-00-01. TST: 16,324.30 HOURS. CYCLES, 2,103. (X)SDR AALA961697Support · corrodedTUL - NR 2 GALLEY INBOARD SUPPORT HAS CORROSION AROUND AFT INBOARD EDGES. INSTALLED NEW NR 2 GALLEY FLOOR SUPPORT PER SRM 53-00-01. TST: 16,324.30 HOURS. CYCLES, 2,103. 9X)SDR AALA961690Seat Track · corrodedTUL - CORROSION ON NR 8 SEAT TRACK ON FLOOR, RT SIDE OF A-ZONE. PERFORMED STANDARD SEAT TRACK REPAIR. PLUG INSTALLATION IAW SRM 53-70-00-0, VOL I, PAGES 8 AND 9, FIG 4, SHEETS 1 AND 2. TST: 16,324.30 HOURS. CYCLES, 2,103. (X)SDR AALA961689Support · corrodedTUL - FLOOR BOARD SUPPORT BETWEEN SEAT TRACKS 5 AN 6 HAS CORROSION AROUND SCREW HOLES. INSTALLED A NEW FLOOR BOARD SUPPORT PER SRM 53-00-01, PAGE 1, VOL I AND PAINTED. TST: 16,324.30 HOURS. CYCLES, 2,103. (X)SDR AALA961688Support · corrodedTUL - FLOOR BOARD SUPPORT AT STA 467 BETWEEN SEAT TRACKS 3 AND 4 HAS CORROSION AROUND ALL SCREW HOLES. INSTALLED A NEW FLOOR BOARD SUPPORT PER SRM 53-00-01, PAGE 1, VOL I. TST: 16,324 HOURS. CYCLES, 2,103. (X)SDR AALA961687Support · corrodedTUL - FLOOR BOARD SUPPORT HAS CORROSION AROUND ALL SCREW HOLES. INSTALLED A NEW FLOORBOARD SUPPORT PER SRM 53-00-01 PAGE 2 VOL I AND PAINTED. (M)SDR AALA961686Support · corrodedTUL - FLOOR BOARD SUPPORT IS CORRODED AT BS 392. FABRICATED NEW FLOOR BOARD SUPPORT PER SRM 53-0, VOL I, PAGE 1 AT STA 392 TO STA 467. PRIMED AND PAINTED. TST: 16,324.30 HOURS. CYCLES, 2,103. (X)SDR AALA961685Support · corrodedTUL - FLOOR BOARD SUPPORT BETWEEN INBOARD AND OUTBOARD NR 2 GALLEY TIE DOWNS HAS CORROSION ON THE AFT END OUTBOARD SIDE. FABRICATE NEW SUPPORT PER SRM VOL I, 53-00-01, PAGE 1. PAINTED AND PRIMED. TST: 16,324.30 HOURS. CYCLES, 2,103. (X)SDR AALA961684Seat Track · corrodedTUL - DURING C-CHECK, FOUND CORROSION ON NR 2 SEAT TRACK UNDER LAVATORY 'L' IN MID-CABIN BETWEEN STA 1312 AND STA 1315. CUT OUT CORROSION AND INSTALLED SEAT TRACK PLUG REPAIR PER SRM 53-70-00, VOL I, PAGES 8-9, FIGURE 4. TST: 16,324.30 HOURS. CYCLES, 2,103SDR AALA961683Seat Track · corrodedTUL - CORROSION ON NR 2 SEAT TRACK ON FLOOR, LT SIDE OF A-ZONE. INSTALLED FLOOR SEAT TRACK REPAIR PLUG IAW SRM CH 53-70-00-0, VOL 1, PAGE 8, FIGURE 4, SHEETS 1 AND 2. TST: 16,324. CYCLES, 2,103. (X)SDR AALA961682Seat Track · corrodedTUL - CORROSION ON NR 1 SEAT TRACK ON FLOOR, LT SIDE, OF A-ZONE. INSTALLED FLOOR SEAT TRACK REPAIR PLUG PER SRM 53-70-00-0, VOL I, PAGE 8, FIGURE 4, SHEETS 1 AND 2. TST: 16,324 HOURS. CYCLES, 2,103. (X)SDR AALA961679Seat Track · corrodedTUL - DURING C-CHECK, FOUND CORROSION ON NR 2 SEAT TRACK UNDER LAVATORY 'L' BETWEEN STA 1346 AND STA 1348 IN MID-CABIN. CUT OUT CORROSION AND INSTALLED SEAT TRACK PLUG REPAIR PER SRM 53-70-00, VOL I, PAGES 8-9, FIG 4. TST: 16,324.30 HOURS. CYCLES, 2,103. SDR DLM11962514Ram Air Inlet · wornTHE RAM AIR INLET DOOR AT ALL THREE POSITIONS WAS FOUND TO BE SEVERELY WORN IN SEVERAL PLACES. THESE INCLUDE THE MOUNT POINTS (P/N ABM7060-503) (DP/N 210701279.SDR DLM11962505Light · inoperativeNUMEROUS EMERGENCY FLOOR TRACK LIGHT OUT. REPLACED ALL EMERGENCY FLOOR TRACK LIGHTS THAT WERE OUT.SDR AALA961630Bulkhead Angle · corrodedTUL - FOUND CORROSION ON PRESSURE BULKHEAD T-ANGLE AT GALLEY SUPPORT NR 4. REPAIRED PER ESO NR 41000, DATED 11/07/96. INSTALLED ANGLE REPAIR OVER DAMAGED AREA 2 FASTENERS BEYOND. (M)SDR AALA961628Bulkhead Angle · corrodedTUL - FOUND CORROSION ON PRESSURE BULKHEAD T-ANGLE AT GALLEY NR 1 SUPPORT. REPAIRED PER ESO 41000 DATED 11/07/96. INSTALLED ANGLE REPAIR OVER DAMAGE 2 FASTENERS BEYOND. (M)SDR AALA961626Bulkhead Angle · corrodedTUL - FOUND CORROSION ON PRESSURE BULKHEAD T-ANGLE AT NR 3 GALLEY SUPPORT. REPAIRED ANGLE PER ESO 41000 DATED 11-27-96. INSTALLED ANGLE REPAIR 2 FASTENERS BEYOND DAMAGE. (M)SDR DLM11962491Gearbox · malfunctionWHEN SLATS EXTENDED ON DESCENT, UNABLE TO CHANGE STABILIZER TRIM, ELECTRICAL OR MANUALLY. CHANGED A/P NO HELP. WHEN A/P ENGAGED, A STAB OUT OF TRIM DEU WARNING WAS DISPLAYED. CONFIG PAGE SHOWED 1.0 ANU AND AFT PRESSURE NEEDED TO CONTROL ALTITUDE. LANDING ATSDR WRLA96049Adc · malfunctionedDURING APPROACH AT SAEZ, FLT CREW ENCOUNTERED MULTIPLE FAULTS (ENGINES NR 1, 2, AND 3 SELECT FADEC ALTERNATE LEVEL 2, SELECT ELEVATOR FEEL MAN, SELECT FLAP LIMIT OVERRIDE, WINDSHEAR DETECTION FAIL). A/C WAS ENCOUNTERING HEAVY TURBULENCE WITH HEAVY PRECIPITATISDR WRLA96048Cowl · damagedDURING LANDING AT SAEZ A/C WAS UNABLE TO STOP ON THE RUNWAY. A/C CONTINUED OFF THE RUNWAY SURFACE AND STOPPED APPROXIMATELY 450 FT PAST THE END OF RUNWAY. NO INJURIES WERE SUSTAINED. GRD PERSONNEL WERE UNABLE TO POSITION MOBILE STAIRWAYS TO AIRCRAFT, HEAVY SDR AALA961615Connector · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT LEFT AISLE BETWEEN L3 AND L4 DOORS INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTOR AT LEFT AISLE BETWEEN L3 AND L4 DOORS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961590Seat Track · corrodedTUL - CORROSION AT LAVATORY 'M' FORWARD INBOARD TIE DOWN LUG. INSTALLED PLUG REPAIR PER SRM 53-70-00. TST 16,115.02 HOURS. CYCLES, 2,121. (X)SDR AALA961589Seat Track · corrodedTUL - FOUND CORROSION AT LAV 'M' AFT INBOARD TIE DOWN LUG. INSTALLED PLUG REPAIR PER SRM 53-70-00. (M)SDR AALA961608Seat Track · corrodedTUL - FOUND CORROSION AT NR 8 RIGHT FLOOR SEAT TRACK FORWARD OUTBOARD CORNER ANCHOR POINT FOR LAV B. INSTALLED CHANNEL PLUG PER SRM 53-70-00-0 VOL 1 FIG 4. (M)SDR AALA961606Seat Track · corrodedTUL - FOUND CORROSION AT NR 1 LEFT FLOOR SEAT TRACK FORWARD OUTBOARD CORNER ANCHOR POINT FOR LAV A. REPLACED CORRODED SECTION WITH SEAT TRACK PLUG AS PER SRM 53-70-00 VOL I FIG 102. (M)SDR AALA961605Seat Track · corrodedTUL - CORROSION AT NR 7 RT FLOOR SEAT TRACK, AFT, INBOARD ANCHOR POINT FOR LAVATORY 'B'. INSTALLED CHANNEL PLUG PER SRM 53-70-00-0, VOL 1, FIG 4. TST: 16,115.02 HOURS. CYCLES, 2,121. (X)SDR DLM11962406Lights · inoperativeEMERGENCY TRACK LIGHTS INOP ON LEFT SIDE AT SEAT ROWS 2 TO 37, 38 TO 40, 41 TO 44, 45 TO 52, 53. RIGHT SIDE AT SEAT ROWS 1 TO 3, 43, 44 TO 46, 47 TO 51.SDR DLM11962409Bulb · failedEMERGENCY TRACK LIGHTS ON LT SIDE AT ROWS 2, 37, 38, 40, 41, 44, 45, 52, 53 AND RT SIDE AT ROWS 1, 3, 43, 44, 46, 47, 51 OUT. RELAMPED TRACK LIGHTS, OPN CK GOOD ON TEST.SDR WRLA96046Tailcone · damagedDURING C-CHECK, (UPON COMPLETION OF UNRELATED REPAIRS), TAILCONE WAS BEING RAISED TO 'STOWED' POSITION WHEN A LOUD 'BANG' WAS HEARD. MAINTENANCE PERSONNEL LOWERED TAIL CONE TO INVESTIGATE. INVESTIGATION FOUND FAILURE OF TAILCONE ACTUATOR ATTACH SUPPORT TO ATSDR AALA961538Seat Track · corrodedTUL - FOUND SEAT TRACK NR 8 HAS CORROSION BETWEEN STATION 899 AND 919. PERFORMED SEAT TRACK PLUG REPAIR PER SRM 53-70-00 VOL I, PAGE 8-9, FIG 4 SHEETS 1 AND 2 ALODINED, TREATED, PRIMED AND PAINTED PER SRM 51-21-01. (M)SDR AALA961537Seat Track · corrodedTUL - FOUND SEAT TRACK NR 5 HAS CORROSION JUST FORWARD OF STATION 919. PERFORMED SEAT TRACK PLUG REPAIR PER SRM 53-70-00 VOL 1 PAGE 8-9 FIG 4 SHEETS 1 AND 2. ALODINED, TREATED, PRIMED AND PAINTED BORE AREAS PER SRM 51-21-01 VOL 2. (M)SDR AALA961536Seat Track · corrodedTUL - FOUND SEAT TRACK NR 6 HAS CORROSION JUST FORWARD OF STATION 919. PERFORMED SEAT TRACK PLUG REPAIR PER SRM 53-70-00 VOL 1, PAGE 8-9, FIG 4 SHEETS 1 AND 2. ALODINED, TREATED, PRIMED AND PAINTED PER SRM 51-21-01, VOL 2. (M)SDR DLM11962557Fire Bottle · low chargeHALON FIRE BOTTLE AT 4L IS LOW.SDR WRLA96043Fmc · malfunctionedDURING INITIAL CLIMB-OUT, FLIGHT CREW EXPERIENCED A DUAL FLIGHT MANAGEMENT COMPUTER FAILURE. PIC ELECTED TO DIVERT TO POINT OF DEPARTURE. AIRCRAFT RETURNED TO AIRPORT OF DEPARTURE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL WERE UNABLE TO DUPSDR DLM11962343Solenoid · malfunctionedAFTER T/O, PILOT NOTICED SLIGHTLY MORE THAN NORMAL AIRFRAME VIBRATION AND NOISE. DURING CLIMB F/A AT DOOR 3L COMPLAINED OF VIBS IN FLOOR. FOUND NR 1 ENGINE LEFT HALF THRUST REVERSER DAMAGED DUE TO UNSCHEDULED OPENING OF 2.9 STABILITY BLEED VALVE. REPLACED 2SDR DLM11962317Light · inoperativeFIRST CLASS EMERGENCY LIGHTS INOP. REPLACED FLOOR TRACK LIGHT SOCKET AT SEAT 1E. CLEANED AND RESEATED CONNECTORS ON FIRST CLASS CONTROLLER AND POWER SUPPLY U1756, OPS CHECKS OK.SDR WRLA96042Boost Pump · failedDURING TAXIING OUT, FLIGHT CREW NOTED UPPER AUXILIARY BOOST PUMP FAILED. FLIGHT CREW ELECTED TO RETURN TO GATE. AIRCRAFT RETURNED TO GATE WITHOUT INCIDENT. MAINTENANCE PERSONNEL REPLACED RIGHT UPPER AUXILIARY BOOST PUMP. RESET RCCB. OPS CHECKED NORMAL. ASDR AALA961516Angle · corrodedTUL - FOUND CORROSION AT STATION 2007 NR 3 GALLEY SUPPORT CONNECTION TO T-ANGLE. INSTALLED REPAIR DOUBLER PER ESO 4100 DATED 10-10-96. (M)SDR AALA961512Angle · corrodedTUL - FOUND CORROSION AT STATION 2007 NR 1 GALLEY SUPPORT CONNECTION TO T-ANGLE. FABRICATED T-ANGLE REPAIR INSTALLED FASTENERS PER ESO 4100, DATED 10-10-96. (M)SDR DLM11962283Oxy Regulator · leakingCREW O2 LOW, FOUND REGULATOR LEAKING AT BOTTLE CONNECTION. REPLACED REGULATOR, SERVICED O2 BOTTLE AND LEAK CK OK.SDR AALA961514Angle · corrodedTUL - FOUND CORROSION AT STATION 2007 NR 8 SEAT TRACK CONNECTION TO T-ANGLE. INSTALLED REPAIR PER ESO 4100, DATED 10-10-96. (M)
Back to Mcdonnell Douglas MD-11