Mcdonnell Douglas MD-11

Service difficulty reports · 7,956

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD11'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WRLA95044Tr · failedDURING INITIAL TAKEOFF ROLL, FLIGHT CREW NOTED NR 1 ENGINE NOT REACHING TARGETED EPR. TAKEOFF TERMINATED. ACFT RETURNED TO GATE. DURING MAINTENANCE T/S, MAINTENANCE CONFIRMED NR 1 ENGINE WOULD NOT ACCELERATE PAST GROUND IDLE POWER. CFDS FAULT REVIEW INDICAOct 23, 1995 · N271WA · Doug MD11 · Engine Thrust ReverserSDR WRLA95043Fmu · failedDURING INITIAL CRUISE, FLIGHT CREW NOTED NR 1 ENGINE EPR INDICATED 10 PERCENT LESS THAN NR 2 AND NR 3 ENGINE WITH ALL N2 MATCHED. FLIGHT CREW CONTACTED MAINTENANCE CONTROL VIA HF RADIO TO DISCUSS THE SITUATION. MAINTENANCE CONTROL REQUESTED THE AIRCRAFT RETOct 22, 1995 · N271WA · Doug MD11 · Fuel Controlling SystemSDR DLM11954076Eel Lamp · brokenDURING MAINT TESTING OF EMERGENCY FLOOR TRACK LIGHTING, FOUND LAMP MODULE AT 2L DOOR DEFECTIVE. REPLACED FLOOR TRACK LAMP MODULE DAL (P/N 330201571), OPERATIONAL TEST NOW OK.Oct 21, 1995 · N803DE · Doug MD11 · Emergency LightingSDR DLM11954073Eel Lamp · failedEMERGENCY PATH LIGHT SYSTEM LIGHT BULBS DAL (P/N 349201652), AT LOCATIONS 1E, 35G, 36G, 39C, LAV-E AND LAV-F INOP. REPLACED BULBS, OPERATION NORMAL.Oct 21, 1995 · N801DE · Doug MD11 · Emergency LightingSDR AALA951826Eel Connector · brokenJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROWS 7 AND 8 AT LT AISLE FOUND INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR BY PASSENGER SEAT ROW 7. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Oct 17, 1995 · N1751A · Doug MD11 · Emergency LightingSDR WRLA95042Temp Sensor · failedOMDB - ON TAXI TO RUNWAY, AIRCRAFT EXPERIENCED A FAILIURE OF THE NR 7 BRAKE TEMPERATURE SENSOR. THE CAPTAIN ELECTED TO RETURN TO THE GATE FOR MAINTENANCE REVIEW OF THE MALFUNCTION. MAINTENANCE REPS INSPECTED THE NR 7 BRAKE TEMP INDICATOR CANNON PLUGS, SECUREOct 8, 1995 · N276WA · Doug MD11 · Landing Gear Brake SystemSDR DLM11954180Doubler · damagedTHE LT LOWER WING SPLICE DOUBLER WAS FOUND WITH A GROOVE IN THE TYPICAL LOCATION WITH THE MAX DEPTH BEYOND CONDITION 2 LIMITS STATED IN THE SERVICE BULLETIN MD11-53-048. ACCOMPLISHED REPAIRS PER DL ERA 271998-14.Oct 3, 1995 · N802DE · Doug MD11 · Wing Miscellaneous StructureSDR AALA951740Eel Connector · brokenJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT LEFT AISLE OF FIRST CLASS CABIN INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR BY FIRST ROW OF PASSENGER SEATS AT LEFT AISLE OF FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. Oct 1, 1995 · N1755 · Doug MD11 · Emergency LightingSDR DLM11953869Eel Bulb · failedSEVERAL EMERGENCY FLOOR TRACK LIGHTS ARE NOT LIGHTING UP. RELAMPED LIGHTS, CKS GOOD.Sep 30, 1995 · N803DE · Doug MD11 · Emergency LightingSDR AALA951738Eel Assy · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT EXIT LAMP AT L4 DOOR INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT EXIT LAMP AT L4 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 27, 1995 · N1753 · Doug MD11 · Emergency LightingSDR WRLA95041Hyd Pump · inoperativeAS AIRCRAFT TAXIED TO THE RUNWAY AT LAX, THE FLIGHT CREW EXPERIENCED A FAILURE OF THE NR 3 HYDRAULIC SYSTEM. THE CAPTAIN ELECTED TO RETURN TO THE GATE. MAINTENANCE PERSONNEL FOUND THE NR 3 ENGINE DRIVEN LEFT HYDRAULIC PUMP INOP. THE PUMP WAS REMOVED AND REPLSep 25, 1995 · N280WA · Doug MD11 · Hydraulic Pump (Electric/Engine), MainSDR AALA951720Control Cable · brokenDFW - DURING B-CHECK, LEFT AILERON TRIM LEFT WING DOWN CABLE FOUND BROKEN AND LEFT AILERON TRIM RIGHT WING DOWN CABLE WAS FOUND BIRD CAGED. REPLACED LEFT AILERON TRIM LEFT WING DOWN AND LEFT AILERON TRIM RIGHT WING DOWN CABLES. ACCOMPLISHED RIGGING AND SYSTESep 24, 1995 · N1759 · Doug MD11 · Aileron Control SystemSDR AALA951704Eel Strip · defectiveJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY PASSENGER SEAT ROW 2D INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP BY PASSENGER SEAT 2D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 20, 1995 · N1759 · Doug MD11 · Emergency LightingSDR AALA951679Eel Conductor · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT RIGHT AISLE BUSINESS CLASS CABIN FORWARD OF CLOSET INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT FLAT CONDUCTOR WIRE AT RIGHT AISLE BUSINESS CLASS CABIN FORWARD OF CLOSET. SYSTEM GROUND CHECKED NORMAL OPESep 18, 1995 · N1755 · Doug MD11 · Emergency LightingSDR DLM11953608Eel Bulb · failedDURING LAYOVER, EMERGENCY FLOOR TRACK LIGTHS AT 40AB TO 47AB OUT. RETERMINATED BROKEN WIRE, RELAMPED AND OPERATION NOW NORMAL.Sep 5, 1995 · N805DE · Doug MD11 · Emergency LightingSDR DLM11953505Eel Bulb · failedFLOOR TRACK LIGHTS INOP AT SEAT 1E AND FWD LEFT GALLEY. RELAMPED.Aug 25, 1995 · N805DE · Doug MD11 · Emergency LightingSDR AALA951530Eel Module · defectiveDFW - DURING CRUISE, THE EMERGENCY EXIT FLOOR PATH LIGHTS ILLUMINATED. CYCLED SWITCH, NO HELP. LANDED DFW WITHOUT INCIDENT. REPLACED FIRST CLASS RIGHT SIDE LIGHT MODULE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Aug 23, 1995 · N1767A · Doug MD11 · Emergency LightingSDR DLM11953373Eel Battery Pack · dischargedEMERGENCY LIGHTS AFT OF SEAT 46 ARE STROBING. REPLACED AFT EMERGENCY BATTERY PACK. EMERGENCY LIGHTS AT 2AB, 3AB, 14G, 49AB, AFT 2 IN FWD GALLEY, RT SIDE ARE INOP. RELAMPED.Aug 8, 1995 · N803DE · Doug MD11 · Emergency LightingSDR WRLA95039Exciter Unit · failedDURNG TAXI, CREW EXPERIENCED A NR 1 ENGINE 'A' IGNITION FAILURE. CAPTAIN ELECTED TO RETURN TO GATE. MAINTENANCE PERSONNEL REMOVED AND REPLACED ENGINE NR 1 IGNITION 'A' EXCITER UNIT. RTS CHECK PERFORMED, NO DISCREPANCIES NOTED. AIRCRAFT RETURNED TO SERVICE.Aug 2, 1995 · N275WA · Doug MD11 · ExciterSDR WRLA95038Rccb · trippedDURING TAXI-OUT, CAPTAIN NOTED REMOTE CONTROL CIRCUIT BREAKER ALERT. AIRCRAFT RETURNED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL SHUT DOWN ENGINE AND PERFORMED RETURN TO SERVICE TEST. OPS CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE. (X)Jul 26, 1995 · N273WA · Doug MD11 · DC Generating SystemSDR AALA951335Eel Wire · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING AFT OF R2 DOOR INOPERATIVE. INSTALLED NEW WIRING BETWEEN R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 25, 1995 · N1758B · Doug MD11 · Emergency LightingSDR WRLA95034Door · bindingDURING TAXI, CAPTAIN NOTED APU INLET DOOR WOULD NOT CLOSE. CAPTAIN ELECTED TO RETURN TO GATE FOR MAINTENANCE TROUBLE-SHOOTING. AIRCRAFT TAXIED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL TROUBLE-SHOOTING DETERMINED THAT APU INLET DOOR LINKAGE BIJul 17, 1995 · N275WA · Doug MD11 · Airborne Auxiliary Power Unit (APU) SystemSDR DLM11953085Fire Loop · faultyAFTER TAKOFF, HAD FIRE BELL AND LIGHTS FOR NR 2 ENGINE. WARNING CEASED, WHEN POWER WAS REDUCED, RETURNED ATL. REPLACED PYLON LOOP A-HARNESS AND LT AND RT REVERSER LOOP AND B-ASSEMBLIES. ALSO, REPLACED UPPER PYLON FIRE LOOP A AND B. OPERATAION NORMAL.Jul 14, 1995 · N810DE · Doug MD11 · Fire DetectionSDR DLM11953084Coffee Maker · smokingDURING CRUISE, BUSINESS CLASS GALLEY AFT COFFEE MAKER BEGAN TO SMOKE AND POP, THEN WATER STARTED TO LEAK. SHUT OFF POWER AND WATER TO MAKER. DISPENSER WAS INITIALY DEFERRED, THEN REPLACED AT PDX.Jul 14, 1995 · N803DE · Doug MD11 · Buffet/GalleysSDR 95ZZZX3581Solenoid Valve · corrodedCORROSION OF PINS IN SOLENOID CONNECTOR CAUSING ARCING AND BURNING OFF PINS RESULTING IN LOSS OF AUTOMATIC CONTROL OF ELEVATOR SURFACE, PCU IS LOCATED IN A RECESS OF THE FUEL TANK IN THE TAIL SECTION. A SAFETY CONCERN SINCE ARCING IS OCCURRING IN THE PROXIMITJul 7, 1995 · Doug MD11 · Elevator Control SystemSDR WRLA95033Shut-Off Valve · failedDURING TAXI, CREW RECEIVED 2/3 HYDRAULIC REVERSIBLE MOTOR PUMP DISAGREE ALERT. FLIGHT CREW ELECTED TO RETURN TO GATE. AIRCRAFT RETURNED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOOTING IDENTIFIED 2/3 HYDRAULIC REVERSIBLE MOTOR PUMP SHUT-OFF VALVE INOPERATIVE. Jul 2, 1995 · N280WA · Doug MD11 · Hydraulic System, MainSDR AALA951109Eel Conductor · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN R2 DOOR AND PASSENGER SEAT ROW 7H INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT FLAT CONDUCTOR WIRE BY R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 16, 1995 · N1758B · Doug MD11 · Emergency LightingSDR AALA951091Eel Wire · brokenDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROW 8D AND L2 DOOR INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY L2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)Jun 15, 1995 · N1767A · Doug MD11 · Emergency LightingSDR WRLA95031Interlock Cyl · failedAFTER TAKEOFF, CAPTAIN OBSERVED LANDING GEAR WOULD NOT RETRACT. CAPTAIN ELECTED TO RETURN TO AIRPORT OF DEPARTURE. AIRCRAFT RETURNED TO BLOCKS WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL FOUND TRIM INTERLOCK CYLINDER WOULD NOT EXTEND AND ALLOW GEAR HANDJun 14, 1995 · N280WA · Doug MD11 · Landing Gear Retraction/Extension SystemSDR AALA951081Eel Connector · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY PASSENGER SEAT ROW 7D INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 8, 1995 · N1751A · Doug MD11 · Emergency LightingSDR DLM11952467Winglet · lightning strikeLIGHTNING STRIKE, RIGHT WING LWR WINGLET T/E BURNED NEAR WING TIP. REPAIRED PER SRM 57-90-00.Jun 5, 1995 · N810DE · Doug MD11 · Wing Miscellaneous StructureSDR DLM11952505Swivel · leakingDURING CRUISE, HAD HYDRAULILC 3 ELEVATOR OFF ALERT ILLUMINATED WITH 4.4 GAL. HYD FLUID. AFTER GEAR LOWERED, HYD QTY DROPPED TO 3.1 AND FALLING. DIVERTED NRT. FOUND GLAND HYDRAULIC SWIVEL LEAKING ON CENTER GEAR. REPLACED GLAND, LEAK CHECK OK.Jun 2, 1995 · N811DE · Doug MD11 · Hydraulic System, MainSDR AALA950972Eel Connector · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS FOUND INOPERATIVE ON RIGHT SIDE OF FIRST CLASS SECTION. REPLACED CONNECTOR AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)May 28, 1995 · N1763 · Doug MD11 · Emergency LightingSDR AALA950948Eel Connector · defectiveJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROWS 21G THROUGH 38G INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT CONNECTOR BY PASSENGER SEAT ROW 21G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 19, 1995 · N1768D · Doug MD11 · Emergency LightingSDR AALA950947Eel Connector · brokenJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 7D AND 15C INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTORS AT PAX SEAT ROWS 7D AND 15C. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 19, 1995 · N1768D · Doug MD11 · Emergency LightingSDR WRLA95028Adc · inoperativeON CLIMB-OUT OF LSZH, FLIGHT CREW EXPERIENCED AN AIRSPEED MISMATCH BETWEEN FLIGHT OFFICERS AND CAPTAINS AIRSPEED INDICATORS. CAPTAINS AIRSPEED WAS IN AGREEMENT WITH THE STANDBY AIRSPEED INDICATOR. CAPTAIN ELECTED TO RETURN TO LSZH. AIRCRAFT RETURNED TO GATEMay 15, 1995 · N275WA · Doug MD11 · Air Data ComputerSDR WRLA95026Detector · brokenDURING INITIAL CRUISE, APPROXIMATELY 2 HOURS AFTER TAKEOFF, NR 1 ENGINE 'FIRE DETECTION' FAIL ANNUNCIATED. FLIGHT CREW ELECTED TO DIVERT TO ALTERNATE AIRPORT. ABNORMAL PROCEDURES WERE FOLLOWED IN DUMPING FUEL TO BRING AIRCRAFT TO BELOW MLW. AIRCRAFT LANDED May 1, 1995 · N280WA · Doug MD11 · Detection SystemSDR WRLA95025Fire Loop · looseDURING INITIAL CRUISE, APPROXIMATELY 1.5 HOURS AFTER TAKEOFF, NR 1 ENGINE 'FIRE DETECTION' FAIL ANNUNCIATED. FLIGHT CREW ELECTED TO RETURN TO DEPARTURE AIRPORT. ABNORMAL PROCEDURES WERE FOLLOWED IN DUMPING FUEL TO BRING AIRCRAFT TO BELOW MLW. AIRCRAFT LANDEMay 1, 1995 · N280WA · Doug MD11 · Fire DetectionSDR WRLA95023Cable · lack of lubeDURING TAXI, CREW NOTED APU DOOR OPEN LIGHT ON. CREW ELECTED TO RETURN TO GATE FOR MAINTENANCE TROUBLESHOOTING. AIRCRAFT TAXIED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE TROUBLESHOOT DETERMINED THAT APU DOOR CABLE WAS BINDING. CABLE WAS CLEANED AND RELApr 29, 1995 · N275WA · Doug MD11 · Auxiliary Power Unit (APU) DoorsSDR WRLA95022Wire · shortedDURING TAXI, CREW NOTED NR 1 AC BUS TIE LOCKED OUT. CREW ELECTED TO RETURN TO GATE FOR MAINTENANCE TROUBLESHOOTING. AIRCRAFT TAXIED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE TROUBLESHOOTING DETERMINED THAT WIRE NR 3-16BL WAS SHORTED TO GROUND, BETWEEN GApr 29, 1995 · N271WA · Doug MD11 · AC Generation SystemSDR WRLA95014Connector · looseON TAXI OUT, FLIGHT CREW NOTED HYDRAULIC SYSTEM TEST FAILED. MANUAL TEST PERFORMED BY FLIGHT CREW. NR 1 HYDRAULIC SYSTEM RIGHT PUMP WOULD NOT TURN OFF WHEN COMMANDED OFF. CAPTAIN ELECTED TO RETURN TO GATE. MAINTENANCE PERSONNEL INSPECTED AND FOUND NR 1 ENGApr 4, 1995 · N271WA · Doug MD11 · Hydraulic System, MainSDR WRLA95013Door Warning · illuminatedON TAXI OUT, 'APU DOOR OPEN' LIGHT ILLUMINATED WHEN FLIGHT CREW ATTEMPTED APU SHUT DOWN. CAPTAIN ELECTED TO RETURN TO GATE. AFTER RETURN TO GATE AND SHUT DOWN OF NR 1 AND NR 3 ENGINE, APU DOOR CLOSED AND LIGHT EXTINGUISHED. MAINTENANCE PERSONNEL RECYCLED APApr 3, 1995 · N275WA · Doug MD11 · Door Warning SystemSDR WRLA95010Ignition · fail lightAFTER PUSHBACK, NR 3 ENGINE 'A' IGNITION FAIL ILLUMINATED. CREW ELECTED TO RETURN TO GATE. GROUND CREW ASSIGNED DMI M74MR19-15 TO NR 3 ENGINE 'A' IGNITION. AIRCRAFT RETURNED TO SERVICE. (X)Mar 19, 1995 · N275WA · Doug MD11 · Ignition SystemSDR DLM11951178Flap · req repairDURING LETTER CHECK, THE RIGHT WING INBOARD TRAILING EDGE WEDGE WAS FOUND WITH TIME LIMITED REPAIR FOR DELAMINATION DAMAGE. INSTALLED PERMANENT REPAIRS PER DALA ERA 270180-14.Mar 18, 1995 · N809DE · Doug MD11 · Trailing Edge FlapsSDR 95FDEA00212Air Bleed Valve · malfunctionedSIN: LOST NR 3 HYD SYSTEM FLUID QTY. THE SYSTEM WENT DOWN TO EMPTY AFTER GEAR RETRACTION. SERVICED NR 3 HYD SYSTEM TO 8.5 GAL, TROUBLESHOT AND RAN HYD SYSTEM AND LEAK CHECKED, NO LEAKS NOTED (SUSPECT AIR BLEED VALVE PLUNGER MAY HAVE STUCK DOWN), ALSO, RAN NRMar 10, 1995 · N605FE · Doug MD11 · Hydraulic System, MainSDR WRLA95008Engine · lpc damageDURING T/O, AT APPROX 80 KTS, CREW HEARD A LOUD 'BANG' FROM NR 3 ENG. A/C BEGAN VEERING TO RT. CREW CORRECTED DIRECTIONAL PATH AND ABORTED T/O. OBSERVED FLAME AND SMOKE FROM NR 3 ENG. CREW SHUTDOWN NR 3 ENG, AND AS A PRECAUTION DISCHARGED THE NR 1 FIRE EXTMar 5, 1995 · N273WA · Doug MD11 · Engine (Turbine/Turboprop)SDR 95FDEA00205Door Frame · crackedTHE LEFT HAND CENTERLINE LANDING GEAR DOOR FRAME IS CRACKED ALONG THE FWD, INBOARD CORNER, CRACK IS APPOX 3.5 INCHES LONG C-CK N/R 7004. REMOVED LT FWD CENTERLINE DOOR AND INSTALLED NEW FRAME. P/N ANB 7387-1 PER SRM 53-00-01.Feb 28, 1995 · N601FE · Doug MD11 · Fuselage Miscellaneous StructureSDR DLM11950830Skin · wornDURING INSPECTION, FOUND WEAR DAMAGE TO WING LEADING EDGE AT THE INTERSECTION OF NR 1 AND NR 2 LEADING EDGE SLATS. REPAIRED PER SRM 57-10-00 PG 63.Feb 26, 1995 · N808DE · Doug MD11 · Wing, Plate/SkinSDR AALA950305Eel Strip · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT RT AISLE OF FIRST CLASS CABIN INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHTS STRIP AT RT AISLE OF FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)Feb 21, 1995 · N1755 · Doug MD11 · Emergency LightingSDR WRLA95004Connector · looseWHILE ON TAXI, FLIGHT CREW OBSERVED NR 1 ENGINE PUMP HYDRAULIC OFF LIGHT WOULD NOT EXTINGUISH. CREW SWITCHED HYD SYSTEM CONTROLLER FROM 'AUTO' TO 'MANUAL' AND THEN BACK TO 'AUTO'. HOWEVER, NR 1 ENGINE LT HYD PUMP WOULD NOT TURN OFF. CREW ELECTED TO RETURN TFeb 20, 1995 · N271WA · Doug MD11 · Hydraulic System, Main
Back to Mcdonnell Douglas MD-11