Service difficulty report · Air Bleed Valve · Doug MD11

Difficulty date
March 10, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N605FE
Make and model
Doug MD11
Aircraft serial
48514
Part
Air Bleed Valve
Condition
Malfunctioned
Location
Nr 3 Hyd Syst
Stage of operation
CL
Nature of condition
F, J, K
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SIN: LOST NR 3 HYD SYSTEM FLUID QTY. THE SYSTEM WENT DOWN TO EMPTY AFTER GEAR RETRACTION. SERVICED NR 3 HYD SYSTEM TO 8.5 GAL, TROUBLESHOT AND RAN HYD SYSTEM AND LEAK CHECKED, NO LEAKS NOTED (SUSPECT AIR BLEED VALVE PLUNGER MAY HAVE STUCK DOWN), ALSO, RAN NR 3 ENGINE TO CHECK FOR LEAKS NOTED. EXCERISED PLUNGER AND OPS CHECKS GOOD. OK FOR SERVICE.