SDR WX0A071418Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 14, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071417Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ANov 14, 2012 · N410NV · Doug MD83 · Emergency LightingSDR WX0A071391Skin · corrodedFOUND CORROSION ON INNER SKIN UNDER BELLY DRAIN RIGHT SIDE OF LONG 30 APPROX STA 731. REMOVED AND REPAIRED FUSELAGE SKIN.Nov 10, 2012 · N883GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071413Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ANov 9, 2012 · N881GA · Doug MD83 · Emergency LightingSDR WX0A071407Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 8, 2012 · N425NV · Doug MD83 · Emergency LightingSDR WX0A071405Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 3, 2012 · N405NV · Doug MD83 · Emergency LightingSDR WX0A071404Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 3, 2012 · N405NV · Doug MD83 · Emergency LightingSDR WX0A071373Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 31, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071372Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 30, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071369Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 28, 2012 · N405NV · Doug MD83 · Emergency LightingSDR WX0A071383Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 27, 2012 · N862NV · Doug MD83 · Emergency LightingSDR WX0A071382Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 27, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071378Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 27, 2012 · N881GA · Doug MD83 · Emergency LightingSDR WX0A071376Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 27, 2012 · N874GA · Doug MD83 · Emergency LightingSDR WX0A071375Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 24, 2012 · N872GA · Doug MD83 · Emergency LightingSDR WX0A071366Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 23, 2012 · N425NV · Doug MD83 · Emergency LightingSDR WX0A071365Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 23, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071364Membrane · corrodedCABIN FLOOR MEMBRANE CORRODED AT STATION 156 TO 160 LBL 15 TO 18. CUT OUT DAMAGED AREA, FABRICATED REPAIR DOUBLER, DRILLED AND INSTALLED IAL MD80 SRM 51-70-4 FIG 2.Oct 23, 2012 · N873GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071357Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 12, 2012 · N863GA · Doug MD83 · Emergency LightingSDR WX0A071362Pan · gougedFORWARD ACCESSORY COMPT DOOR PAN HAS GOUGES AT 11 O'CLOCK. CUT OUT DAMAGED AREA, FABRICATED REPAIR DOUBLER & FILLER AND INSTALLED REPAIR PARTS IAW MD-80 SRM 51-70-5 FIG 1.Oct 11, 2012 · N863GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071361Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 11, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A071360Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 11, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A071359Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYOct 11, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A071358Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 11, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A071356Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 11, 2012 · N49555 · Doug MD83 · Emergency LightingSDR WX0A071355Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 11, 2012 · N411NV · Doug MD83 · Emergency LightingSDR WX0A071354Pan · gougedFORWARD ACCESSORY DOOR PAN HAS A GOUGE AT 1 O'CLOCK POSITION. CUT OUT DAMAGED AREA, FABRICATED REPAIR DOUBLER FILLER AND INSTALLED REPAIR PARTS IAW MD-80 SRM 51-70-5 FIG 1.Oct 10, 2012 · N863GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071351Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 10, 2012 · N875GA · Doug MD83 · Emergency LightingSDR WX0A2012101171345Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 9, 2012 · N420NV · Doug MD83 · Emergency LightingSDR WX0A071344Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATOct 7, 2012 · N416NV · Doug MD83 · Emergency LightingSDR WX0A071352Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 6, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071343Skin · corrodedEXFOLIATION CORROSION AT THE LOWER CORNERS OF THE AFT WASTE SERVICE PANEL. REPAIR FROM FS 1287 TO FS 1338 BETWEEN LONGERON L-18L TO L-23L PER MD80 SRM 51-10-38 PG 1. CUT OUT AND REMOVED CORROSION FROM OUTER SKIN AND DOUBLER AT THE FWD LOWER CORNER OF THE AFTOct 5, 2012 · N865GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071347Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS AOct 5, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071346Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATOct 5, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071345Skin · corrodedEXFOLIATION CORROSION AT THE LOWER CORNERS OF THE AFT WASTE SERVICE PANEL. REPAIR FROM FS 1287-1338 BETWEEN L18L TO L23L PER MD80 SRM 51-10-38 PG 1. REMOVED CORROSION FROM OUTER SKIN AT THE FWD LOWER CORNER OF THE AFT LAV SERVICE DOOR CUTOUT. REMOVED CORROSOct 5, 2012 · N865GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071353Skin · corrodedANTENNA CUTOUT BETWEEN STA 229 TO STA 237 DOUBLER/TRIPLER CORRODED, CUTOUT DAMAGED AREA. REMOVED AND REPLACED LOWER SKIN STATION 229 TO STATION 275 LONGERON 26R TO LONGERON 27L IAW MD80 SRM 53-04 FIGURE 12C.Oct 3, 2012 · N860GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071350Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 2, 2012 · N875GA · Doug MD83 · Emergency LightingSDR WX0A071349Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 1, 2012 · N863GA · Doug MD83 · Emergency LightingSDR WX0A071348Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 1, 2012 · N425NV · Doug MD83 · Emergency LightingSDR WX0A071335Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 30, 2012 · N863GA · Doug MD83 · Emergency LightingSDR WX0A071334Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 30, 2012 · N863GA · Doug MD83 · Emergency LightingSDR WX0A071328Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 30, 2012 · N416NV · Doug MD83 · Emergency LightingSDR WX0A071326Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATSep 29, 2012 · N408NV · Doug MD83 · Emergency LightingSDR WX0A071339Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 28, 2012 · N884GA · Doug MD83 · Emergency LightingSDR WX0A071338Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 28, 2012 · N884GA · Doug MD83 · Emergency LightingSDR WX0A071327Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASep 28, 2012 · N416NV · Doug MD83 · Emergency LightingSDR WX0A071342Light · shortedPILOT: SMELL OF ELECTRICAL SMOKE REPORTED BY F/A'S BEFORE LANDING BUT NO VISIBLE SMOKE SEEN, REPORTED FROM FRONT TO BACK OF CABIN. FOUND LIGHT BULB ON OVERHEAD SIDE WALL ROW 28DEF SHORTING OUT. RELAMPED OVERHEAD SIDE WALL LIGHT IAW MM 33-21-03. OP'S CHECK NSep 27, 2012 · N419NV · Doug MD83 · Passenger Compartment LightingSDR WX0A071329Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASep 26, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071325Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASep 26, 2012 · N407NV · Doug MD83 · Emergency LightingSDR WX0A071337Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 25, 2012 · N877GA · Doug MD83 · Emergency Lighting
Back to Mcdonnell Douglas MD 83