Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2013F00085Pa System · inoperativeP/A ADDRESS SYSTEM OVER CABIN SPEAKERS INOP.Mar 13, 2013 · N836NK · Doug MD83 · Interphone/Passenger Announcement (PA) SystemSDR 2013F00084Pa System · inoperativeP/A SYSTEM AT RC INOP IN FLIGHT.Mar 13, 2013 · N120MN · Doug MD83 · Interphone/Passenger Announcement (PA) SystemSDR WX0A2013032171539Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMar 12, 2013 · N422NV · Doug MD83 · Emergency LightingSDR WX0A2013030471523Door Frame · corrodedAFT CARGO DOOR CUTOUT FRAME AT FS 1155 IS CORRODED AT FWD FACE OF FRAME. FABRICATED CHANNEL, FILLER, INTERCOSTAL AND CLIPS AND INSTALLED REPAIR PARTS.Feb 24, 2013 · N874GA · Doug MD83 · Fuselage Main, StructureSDR WX0A2013030471520Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERFeb 21, 2013 · N410NV · Doug MD83 · Emergency LightingSDR WX0A071517Doubler · missingMODE'S ANTENNA INNER ATTACH DOUBLER AT FS 1212 TO FS 1231 IS MISSING FINGER DOUBLER AND DOES NOT GROUND LT AND RT LONGERON. REMOVED EXISTING DOUBLER, FABRICATED NEW DOUBLER AND INSTALLED.Feb 17, 2013 · N874GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071510Frame · gougedLIP UNDER LT AND RT LOWER SIDEWALL PANEL MOUNT SCREWS AT FRAME 522 HAVE SCREW GOUGES. REPLACED FUSELAGE FRAME AT STATION 522.Feb 1, 2013 · N893GA · Doug MD83 · Fuselage Main, FrameSDR WX0A2013020471504Skin · gougedFUSELAGE SKIN BS 1485, GOUGED AT L3L. FABRICATED INTERNAL DOUBLER AND INSTALLED.Jan 30, 2013 · N893GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071503Pan · crackedAFT CARGO DOOR INNER AND OUTER PAN IS CRACKED. REMOVED DAMAGED AREA, FABRICATED REAIR PANS AND INSTALLED.Jan 30, 2013 · N893GA · Doug MD83 · Cargo/Baggage DoorsSDR WX0A071500Skin · gougedFORWARD CARGO PIT DOOR OUTER LOWER SKIN EDGE GOUGED. REMOVED DAMAGED AREA. HFEL - NO DEFECTS NOTED. FABRICATED REPAIR PARTS AND INSTALLED.Jan 25, 2013 · N893GA · Doug MD83 · Cargo/Baggage DoorsSDR WX0A071499Frame · gougedRIGHT STATION 1510 CANT FRAME GOUGED AT LONGERON 9L. REMOVED DAMAGED AREA, HFEL. HFEL - NO DEFECTS NOTED. FABRICATED REPAIR ANGLE AND INSTALLED.Jan 25, 2013 · N893GA · Doug MD83 · Fuselage Main, FrameSDR WX0A071498Web · corrodedAFT CARGO PIT LOWER DOOR SURROUND WEB IS CORRODED BETWEEN STATION 1155 TO 1173. BLEND AREA, HFEL. NO DEFECTS NOTED. FABRICATED REPAIR DOUBLER AND INSTALLED.Jan 25, 2013 · N893GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A201301291496Skin · corrodedFUSELAGE SKIN DOUBLER AT E & E BAY DOOR CUTOUT FS 134.299 BETWEEN LONGERON 28L AND 28R CORRODED. BLENDED THE DAMAGED AREA HFEL AREA. NO DEFECTS NOTED. FABRICATED REPAIR PARTS AND INSTALLED.Jan 24, 2013 · N893GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071508Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 21, 2013 · N427NV · Doug MD83 · Emergency LightingSDR WX0A071490Vane · chafedLEFT WING O/B FLAP I/B VANE L/E CHAFED. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED.Jan 21, 2013 · N893GA · Doug MD83 · Trailing Edge FlapsSDR WX0A071509Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 20, 2013 · N873GA · Doug MD83 · Emergency LightingSDR WX0A071489Frame · damagedAFT CARGO COMPARTMENT FRAME STATION 1136 UPPER LIP DAMAGED AT LONGERON 29L. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED.Jan 19, 2013 · N893GA · Doug MD83 · Fuselage Main, FrameSDR WX0A071507Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071506Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071505Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071484Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071483Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071482Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071486Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 14, 2013 · N892GA · Doug MD83 · Emergency LightingSDR WX0A201301140085Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY LIGHTS WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED BATTERY PACK IN POWER SUPPLY. OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPS CHECKED NORMALJan 14, 2013 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071474Bulkhead · crackedRIGHT CANTED BULKHEAD 1463 AS 2 EACH CRACKS AT LONGERON 17R AND 18R. STOP DRILLED CRACKS, FABRICATED REPAIR DOUBLERS AND SHIMS.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Main, BulkheadSDR WX0A071472Drag Angle · crackedLEFT CANTED BULKHEAD 1463 DRAG ANGLE CRACKED IN EXISTING DOUBLER. REMOVED AND REPLACED DRAG ANGLE AT 181.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071471Drag Angle · crackedRIGHT CANTED BULKHEAD 1463 DRAG ANGLE CRACKED. REMOVED DAMAGED ANGLE. FABRICATED NEW ANGLE AND INSTALLED.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071476Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 7, 2013 · N410NV · Doug MD83 · Emergency LightingSDR WX0A071462Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 30, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071456Ballast · burnedSMOKE IN THE CABIN REPORTED. DISCOVERED SIDEWALL LIGHT HAD BURNT BALLAST. DISCONNECTED BALLAST.Dec 29, 2012 · N409NV · Doug MD83 · Lighting SystemSDR WX0A071464Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 27, 2012 · N883GA · Doug MD83 · Emergency LightingSDR WX0A071443Skin · damagedMID PIT - DRILL START AT WATER DRAIN HOLE FWD OF STA 655. FABRICATED REPAIR STRAP AND INSTALLED.Dec 16, 2012 · N881GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071442Skin · corrodedMID PIT CORROSION FWD OF STA 617 BETWEEN L-30, L-29 R BY WATER DRAIN HOLE. REMOVED CORROSION, FABRICATED REPAIR STRAPS AND INSTALLED.Dec 16, 2012 · N881GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071453Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 13, 2012 · N881GA · Doug MD83 · Emergency LightingSDR WX0A071451Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 12, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071450Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 12, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071440Cargo Track · corrodedAFT CARGO TRACK RIGHT FWD CORRODED FROM FS 1079 TO 1155 MARKED 193A. REMOVED CORRODED SECTION, FABRICATED NEW SECTION AND REPAIR SPLICES.Dec 12, 2012 · N881GA · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A071431Skin · chafedFWD CARGO DOOR LOWER EXTERNAL SKIN CHAFED AT STA 380 AND STA 415. CUT OUT DAMAGED AREAS, HFEC INSPECTED - NO DEFECTS NOTED. FABRICATED, LOCATED, DRILLED FILLER, DOUBLER AND INSTALLED.Dec 9, 2012 · N881GA · Doug MD83 · Cargo/Baggage DoorsSDR WX0A071438Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 5, 2012 · N425NV · Doug MD83 · Emergency LightingSDR WX0A071437Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 3, 2012 · N425NV · Doug MD83 · Emergency LightingSDR WX0A071436Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 2, 2012 · N422NV · Doug MD83 · Emergency LightingSDR WX0A071423Skin · chafedRIGHT O/B FLAP I/B VANE LEADING EDGE IS CHAFED AT I/B CORNER, 193A029 MARKED. REMOVED RIGHT WING O/B FLAP I/B FLAP VANE AND REPAIRED AREA, RE-INSTALLED AND C/W CLEARENCE CHECKS.Dec 1, 2012 · N872GA · Doug MD83 · Trailing Edge FlapsSDR WX0A071429Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 26, 2012 · N881GA · Doug MD83 · Emergency LightingSDR WX0A071402Cusp Web · corrodedAFT CARGO COMPARTMENT CUSP WEB CORRODED BETWEEN FLOORBEAMS AT STATION 1174 TO 1193 RBL 52. REMOVED DAMAGED AREA AND INSTALLED FILLER AND DOUBLER REPAIR.Nov 18, 2012 · N883GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071390Cusp Web · corrodedAFT CARGO COMPARTMENT TO CABIN CSP WEB CORRODED BETWEEN STATION 1193 TO 1211 AT RBL 52. REMOVED DAMAGE AREA AND INSTALLED FILLER AND DOUBLER.Nov 18, 2012 · N883GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071389Door Frame · crackedAFT ENTRY DOOR FRAME CRACKED AT LEFT UPPER CORNER.Nov 17, 2012 · N883GA · Doug MD83 · Fuselage Main, StructureSDR WX0A071420Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 15, 2012 · N883GA · Doug MD83 · Emergency LightingSDR WX0A071388Web · crackedLEFT ENGINE INLET COWL AFT WEB CRACKED AT ACCESS PANEL FASTENER AT 4:30 O'CLOCK POSITION.Nov 15, 2012 · N883GA · Doug MD83 · Nacelle/Pylon Miscellaneous StructureSDR WX0A071387Pan · chafedFWD ACCESSORY DOOR JAMB PAN CHAFED AT FWD END IN LOWER RADIUS.Nov 15, 2012 · N883GA · Doug MD83 · Fuselage Miscellaneous Structure
Back to Mcdonnell Douglas MD 83