SDR WX0A070856Apu · faultyAFTER LANDING AND STARTING APU, CABIN AND COCKPIT HAD STRONG OILY ODOR WHEN RIGHT PACK WAS PLACED ON APU AIR. INSTALLED SERVICEABLE APU SEE TASK CARD R0594902 FOR WORK ACCOMPLISHED. AIRCRAFT RETURNED TO SERVICE.SDR WX0A070855Floor Panel · crackedCABIN O/B LT FLOOR PANEL CHANNEL CRACKED STA 925.5 TO 923 AREA. STOP DRILLED CRACK, VERIFIED CONTAINMENT, FABRICATED DOUBLER, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 53-05 PARA 145.SDR WX0A070854Tab · dentedRT ELEVATOR CONTROL TAB LOWER SURFACE DENTED 6.375 INCHES FROM I/B END AND 3 INCHES FROM T/E DENT MEASURES .013 DEEP. PREPARED DAMAGED AREA FOR BOND REPAIR, FABRICATED DOUBLER AND BONDED IAW MD80 SRM 51-70-02.SDR WX0A070871Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070866Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070853Apu · leakingHOT FUME SMELL IN CABIN & COCKPIT. COMPLETED SMOKE/FUMES REMOVAL CHECKLIST AND FUME SMELL DISSIPATED. PERFORMED TROUBLESHOOTING PER 21-20-00 AND FOUND APU OIL LEAK BEING INGESTED. PERFORMED BURNOUT OF HIGH PRESSURE PNEUMATIC DUCTING PER AMM 21-20-02 NO HOT SDR WX0A070849Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR YYFAN120MNFlight Dir · failedBOTH FLIGHT DIRECTORS FAILED IN FLIGHT.SDR WX0A070847Cargo Track · damagedAFT CARGO COMPARTMENT RT CARGO TRACK HAS DOUBLE DRILL HOLE IN FLANGE STA 1007. REMOVED AND REPLACED RT CARGO TRACK STA 1007-1155 AND SPLICE IAW MD-80 SRM 51-30-02.SDR WX0A070846Cargo Track · corrodedAFT CARGO COMPARTMENT L&R CARGO TRACK CORRODED AT NUMEROUS ATTACH FASTENER HOLES FROM STA 1007 TO 1320 (CENTER ATTACH FASTENERS). REMOVED AND REPLACED LT CARGO TRACK STA 1007-1155 AND SPLICE IAW MD-80 SRM 51-30-02.SDR WX0A070845Skin Panel · chafedVERT STAB CHAFE ON LT LOWER BANANA PANEL AREA AFT END. VERT STAB LT SIDE LOWER SKIN PANEL REPAIRED IAW EA 14379 REV I/R.SDR WX0A070844Cargo Track · corrodedAFT CARGO COMPARTMENT LT CARGO TRACK CORRODED ON OUTBOARD SUPPORT FLANGE IN NUMEROUS AREA FROM F/STA 1079-1320. REMOVED AND REPLACED CARGO TRACK ON LT SIDE OF AFT CARGO COMPT FROM STA 1155-1320 IAW MD-80 SRM 53-05 FIG 4G.SDR WX0A070843Skin · chafedVERTICAL STAB TIP FAIRING CHAFED ON RT AFT SIDE OUT OF LIMITS. REMOVED & REPLACED FAIRING SKIN IAW EA 14380 REV I/R DATED 06/MAY/2011.SDR WX0A070842Intercostal · corrodedAFT PIT INTERCOSTAL CORRODED STA 1309 TO STA 1320 LBL 16.5. REMOVED DAMAGE INTERCOSTAL, LOCATED, DRILLED, AND INSTALLED A NEW INTERCOSTAL IAW MD80 SRM 51-30-2 FIG 3 AND FIG 19.SDR WX0A070851ABattery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070850Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A07840Longeron Splice · corrodedMID CARGO PIT LONGERON 30 SPLICE CORRODED STA 590 TO STA 605 AREA. REMOVED DAMAGED SPLICE, LOCATED, DRILLED, AND INSTALLED A NEW SPLICE IAW MD80 SRM 51-30-1.SDR 2011FA0000294Seal · failedCABIN FAILED TO PRESSURIZE ON CLIMB OUT-UNABLE TO MAINTAIN CABIN IN MANUAL MODE-F/A REQ MX DUE MASSIVE LEAK L-2 DOOR-MX REPORTED MASSIVE LEAK AND DAY LIGHT AROUND L-2 DOOR. ACFT RETURNED TO DEPARTURE WHERE FLIGHT WAS TERMINATED. MX ON THE GROUND INSPECTED ACSDR WX0A070839Coalescer Bag · dirtyWHILE DEPLANING, CABIN FILLED WITH SMOKE, ALL PASSENGERS AND CREW TAKEN OFF PLANE. SHUT OFF ELECTRICAL ON PLANE. DURING WALK AROUND FOUND PUDDLE OF HYDRAULIC FLUID FROM REVERSER ACCESS PANEL. FOUND RETURN LINE LEAKING AT THRUST REVERSER LEFT CONTROL VALVE. TSDR WX0A070852Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070848Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070837Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A20110418001Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR EE4Y1104016Support · crackedLOWER FUSELAGE FWD CARGO COMPARTMENT AT STA 465,-X30 CAB FLOORBEAM AREA WATER HOSE SUPPORT CRACKED.SDR EE4Y1104015Skin · dentedLOWER FUSELAGE FROM YSTA 1330 TO 1338 BETWEEN LONGERON 20LT AND 21 LT SKIN DENTED.SDR EE4Y1104014Skin · dentedLOWER FUSELAGE AT Y STA 383.5 BETWEEN LONG 19R AND 20R SKIN WITH A DENT.SDR EE4Y1104013Skin · dentedUPPER FUSELAGE, AT 1187 AND 1174 BTWEEN LONG 17 LT AND 18 LT, SKIN WITH DENTS. REPAIRED WITH A FAA DER APPROVAL.SDR EE4Y1104012Skin · dentedLOWER FUSELAGE AT 226.5 AND 258.5 BETWEEN LONG 19 LT AND 19 LT SKIN WITH DENTS.SDR EE4Y1104011Skin · dentedLOWER FUSELAGE EXTERNAL FUSELAGE AT STA 250.5 BETWEEN LONGERONS 18L AND 19L SKIN DENTED. REPAIRED WITH A FAA DER.SDR 2011F00091Instrument Panel · multiple failDURING CRUISE FLT, CREW REPORTED, LOST BOTH NR1 AND NR2 DFGC. NO AUTO PILOT, NO AUTO THROTTLES, NO FLIGHT DIRECTORS. DISPATCH WAS ADVISED, ADVISED AND REROUTED ACFT FOR REPAIRS.SDR WX0A070838Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070831Seat Track · corrodedMAIN CABIN SEAT TRACK HAS CORROSION AND SCRATCHED AT RBL 22 STA 200 TO 446 MKD. REMOVED CORROSION AND SCRATCHES STA 266 TO 446, RBL 22 IAW MD80 SRM 51-10-3. TREATED, PRIMED AND TOPCOATED. REMOVED AND REPLACED SEAT TRACK SECTION STA 200 TO 266 PER MD80 SRM 5SDR WX0A070828Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070826Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070825Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070830Seat Track · corrodedMAIN CABIN SEAT TRACK HAS CORROSION AT RBL STA 200-237 MKD. REMOVED CORROSION AT MAIN CABIN SEAT TRACK STA 200-237 RBL 44 IAW MD80 SRM 51-10-3. ORGINIAL MATERIAL 115 MATERIAL LOSS .053 FOUND OUT OF LIMITS IAW MD80 SRM 53-05 FIG 4-8-1. REMOVED AND REPLACED SSDR WX0A070829Seat Track · corrodedSEAT TRACK AT STA 226 CORRODED. REMOVED AND REPLACED NEW SEAT TRACK SECTION AT MAIN CABIN LBL 22 FROM STA 200 TO STA 304.5 IAW EA 05-2011-136 AND MD80 SRM 51-30-1 AND 53-05.SDR EE4Y1104010Longeron · corrodedLOWER FUSELAGE AFT CARGO COMPARTMENT AT STA 1201.5, LONG 28L CORRODED.SDR EE4Y1104009Fitting · corrodedLOWER FUSELAGE AFT CARGO COMPARTMENT AT STA 1155 BETWEEN LONG 29R AND 30 CLIP CORRODED.SDR EE4Y1104008Plate · crackedRT WING T/E AT XCW 47.45 DEBRIS DEFLECTOR PLATE CRACKED. REPLACED THE PART.SDR EE4Y1104007Floor Support · damagedLOWER FUSELAGE, FWD CARGO COMPARTMENT FROM Y STA 370 T Y STA 427 AT LONG 29R FLOOR SUPPORT WITH ELONGATED HOLES. REPLACED PART DAMAGE.SDR EE4Y1104006Skin · dentedUPPER FUSELAGE FROM Y STA 200 T Y STA 217 BETWEEN LONG 13 AND 16 LT SKIN WITH DENTS IN SEVERAL PLACES.SDR EE4Y1104005Rib · crackedLT WING LEADING EDGE CAVITY NR 4 SLAT, I/B RIB CRACKED AT XRS 100. ACTION CORRECTIVE, FAA DER REPAIR APPROVAL.SDR EE4Y1104003Attach Angle · corrodedCOO REPORTS LOWER FUSELAGE AFT CARGO COMPARTMENT AT Y STA 1098 AT LONGERON 30 ATTACHMENTS ANGLE WITH CORROSION.SDR EE4Y1104002Floor Support · corrodedCOO REPORTS LOWER FUSELAGE FWD CARGO COMPARTMENT AT Y STA 427, BETWEEN LONG 28L AND 29R FLOOR SUPPORT WITH CORROSION IN SEVERAL PLACES.SDR EE4Y1104001Support Angle · crackedCOO REPORTS LOWER FUSELAGE MID CARGO COMPARTMENT AT Y STA 788 BETWEEN LONG 27L AND 28L SUPPORT ANGLE WITH CRACK.SDR WX0A070821Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070827Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070824Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070823Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
Back to Mcdonnell Douglas MD 83