What was found
CABIN O/B LT FLOOR PANEL CHANNEL CRACKED STA 925.5 TO 923 AREA. STOP DRILLED CRACK, VERIFIED CONTAINMENT, FABRICATED DOUBLER, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 53-05 PARA 145.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN O/B LT FLOOR PANEL CHANNEL CRACKED STA 925.5 TO 923 AREA. STOP DRILLED CRACK, VERIFIED CONTAINMENT, FABRICATED DOUBLER, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 53-05 PARA 145.