Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR EE4Y1101025Doubler · crackedLT WING UPPER SKIN REAR SPAR MAIN LANDING GEAR SUPPORT FITTING DOUBLER WITH CRACK. REPAIRED MAIN LANDING GEAR SUPPORT UPPER DOUBLER IN ACCORDANCE WITH MD-80 SRM 57-03 FIGURE 34.Jan 4, 2011 · N786TW · Doug MD83 · Wing Miscellaneous StructureSDR EE4Y1101024Shear Tie · corrodedLOWER FUSELAGE AFT CARGO COMPARTMENT FORMER (SHEAR TIE) WITH CORROSION AT STA Y 1193 BETWEEN LONGERON 29L AND LONGERON 29R. DAMAGED PART WAS REPAIRED PER MD-80 SRM 53-03 FIGURE 3.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Internal Mounting StructureSDR EE4Y1101023Frame · corrodedLOWER FUSELAGE AFT CARGO COMPARTMENT STA 1219 BETWEEN LONGERONS 29R AND 29L FRAME WITH CORROSION. DAMAGED FRAME WAS REPAIRED PER MD-80 SRM 53-03 FIGURE 3.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Main, FrameSDR EE4Y1101022Skin · dentedLOWER EXTERNAL FUSELAGE AT STA 536.25 BETWEEN LONGERONS 24L AND 25L SKIN WITH DENT. DAMAGED SKIN WAS REPAIRED PER MD-80 DWG SG0953002 VIEW C1 SHEET 1 AND 4.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1101021Skin · dentedLOWER EXTERNAL FUSELAGE AT STA 536.25 BETWEEN LONGERONS 24L AND 25L SKIN WITH DENT. DAMAGED SKIN WAS REPAIRED PER MD-80 DWG SG0953002 VIEW C1 SHEET 1 AND 4.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1012014Floorbeam · corrodedUPPER FUSELAGE PAX CABIN, FLOORBEAM UPPER CHORD LOWER SURFACE WITH CORROSION AT Y STA 1322 AND +X23. DAMAGED AREA WAS REPAIRED PER MD-80 SRM 53-05 FIGURE 79A.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Main, Floor BeamSDR EE4Y1012013Frame · crackedLOWER FUSELAGE AFT ACCESSORY COMPARTMENT AT CANT STA 1485 RT SIDE STAIR ACTUATOR SUPPORT FRAME WITH CRACK. THE DAMAGED PART WAS REPAIRED AS PER MD-80 SRM 53-03 FIGURE 43 VIEW C.Jan 4, 2011 · N786TW · Doug MD83 · Fuselage Main, FrameSDR WX0A070736Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 1, 2011 · N871GA · Doug MD83 · Emergency LightingSDR WX0A070735Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 1, 2011 · N871GA · Doug MD83 · Emergency LightingSDR WX0A070729Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 31, 2010 · N871GA · Doug MD83 · Emergency LightingSDR WX0A070728Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 31, 2010 · N871GA · Doug MD83 · Emergency LightingSDR EE4Y1012020Skin · damagedLOWER FUSELAGE SKIN DAMAGED LOCATED AT STA Y429, BETWEEN LONG 28R AND LONG 29R. PERMANENT REPAIR APPROVED BY LOCAL DER.Dec 31, 2010 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1012019Skin · damagedLOWER FUSELAGE SKIN DAMAGED LOCATED AT STA Y429, BETWEEN LONG 28R AND LONG 29R. PERMANENT REPAIR APPROVED BY LOCAL DER.Dec 31, 2010 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1012018Skin · dentedLOWER EXTERNAL FUSELAGE SKIN DENTED AT STA Y363.5 BETWEEN LONG 28R AND LONG 29R. PERMANENT REPAIR APPROVED BY LOCAL DER.Dec 30, 2010 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1012017Skin · corrodedDURING STRUCTURAL INSPECTION COOPESA REPORTED AT LOWER FUSELAGE FWD CARGO COMPARMENT LT FWD LAVATORY SERVICE PANEL INTERNAL SKIN WITH CORROSION.Dec 30, 2010 · N786TW · Doug MD83 · Fuselage Main, Plate/SkinSDR EE4Y1012016Angle · crackedEMPENNAGE VERTICAL STABILIZER DORSAL FIN JOINT ANGLE RT SIDE AT CANT STATION WITH CRACK. THE PART WAS REPAIRED FOLLOWING MD-80 SRM 53-05 FIGURE 23 REV 106.Dec 30, 2010 · N786TW · Doug MD83 · Fuselage, Stabilizer Attach FittingsSDR EE4Y1012012Longeron · corrodedAFT CARGO COMPT STA Y1203 LONGERON 30 DAMAGED.Dec 30, 2010 · N786TW · Doug MD83 · Fuselage Main, Longeron/StringerSDR EE4Y1012011Fitting · corrodedAFT CARGO COMPT STA 1211 WITH CLIP DAMAGED, BETWEEN LONG 26L AND LONG 29R.Dec 30, 2010 · N786TW · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070727Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 29, 2010 · N416NV · Doug MD83 · Emergency LightingSDR WX0A070725Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 26, 2010 · N883GA · Doug MD83 · Emergency LightingSDR WX0A070724Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 26, 2010 · N883GA · Doug MD83 · Emergency LightingSDR WX0A070723Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 26, 2010 · N881GA · Doug MD83 · Emergency LightingSDR WX0A070720Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 24, 2010 · N417NV · Doug MD83 · Emergency LightingSDR RYNA2010122100039Power Supply · inoperativeCABIN EMERGENCY LIGHTS JUST FORWARD OF AFT GALLEY COMES ON WHEN BATTERY SWITCH IS TURNED OFF. REMOVED AND REPLACED BATTERY POWER SUPPLY IAW AMM 33-53-00. OPERATIONAL CHECKED GOOD.Dec 21, 2010 · N976AS · Doug MD83 · Emergency LightingSDR 2WAA20101227Hydraulic System · leakingAFTER SLAT EXT DURING THE APP, LT HYD SYS PRESSURE CYCLES TO ZERO PRESS, QTY NORMAL.Dec 21, 2010 · N802WA · Doug MD83 · Hydraulic System, MainSDR WX0A070719Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 20, 2010 · N405NV · Doug MD83 · Emergency LightingSDR WX0A070722Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 19, 2010 · N878GA · Doug MD83 · Emergency LightingSDR WX0A070709AVane · gougedLT WING OUTBOARD FLAP CENTER VANE LEADING EDGE GOUGED IN CENTER AREA STA XTE250 AT PREVIOUS REPAIR AREA. REMOVED PREVIOUSLY INSTALLED DOUBLER, FABRICATED REPAIR DOUBLER AND BONDED IAW 51-70-2 REPAIR 18.Dec 17, 2010 · N891GA · Doug MD83 · Trailing Edge FlapsSDR WX0A070721Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALDec 17, 2010 · N875GA · Doug MD83 · Emergency LightingSDR WX0A070710Vane · dentedRT WING OUTBOARD FLAP CENTER VANE DENTED ON INBOARD SIDE STA XTE 215 AREA. PREPARED DAMAGED AREA, FABRICATED REPAIR DOUBLER AND BONDED IAW MD80 SRM 57-03 FIG 11.Dec 17, 2010 · N891GA · Doug MD83 · Trailing Edge FlapsSDR WX0A070708Vane · gougedLT WING OUTBOARD FLAP CENTER VANE L/E GOUGED IN CENTER AREA STA XTE 250 AT PREVIOUS REPAIR AREA. REMOVED PREVOUSLY INSTALLED DOUBLER, FABRICATED REPAIR DOUBLER AND BONDED IAW 51-70-2 REPAIR 18.Dec 17, 2010 · N891GA · Doug MD83 · Trailing Edge FlapsSDR WX0A20101216001Skin · dentedACCOMPLISHED PERMANENT REPAIR ON DENT LOCATED ON RT FUSELAGE STA 229 BETWEEN LONGERONS 17R AND 18R. CUT OUT DAMAGED AREA, FABRICATED, LOCATED, DRILLED AND INSTALLED REPAIR PARTS AND DOUBLER IAW MD80 SRM 53-04 FIG 12C.Dec 16, 2010 · N891GA · Doug MD83 · Fuselage Main, Plate/SkinSDR 2ARF201012003Motor · damagedACFT PERFORMED AN UNSCHEDULED LANDING; DURING LANDING THE STAB OUT OF TRIM LIGHT TUNED ON. MX REPLACED THE STABILIZER TRIM MOTOR IAW MM 27-41-71, TESTED CORRECT.Dec 13, 2010 · N583MD · Doug MD83 · Stabilizer Position IndicatingSDR WX0A070711Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ADec 10, 2010 · N418NV · Doug MD83 · Emergency LightingSDR WX0A070707Sill · crackedAFT ENTRY DOOR CRACK AFT FLIGHT ATTENDANT UPPER DOOR SILL LT SIDE FACING AFT HAS 0.25 INCH CRACK AT 1:00 O`CLOCK POSITION. INSTALLED REPAIR DOUBLER IAW MD80 SRM 53-05 FIG 29.Dec 9, 2010 · N879GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070706Longeron · crackedLONGERON 24 LEFT IS CRACKED AT FS 200 IN AVIONICS BAY. REPAIRED CRACKED LONGERON 24L IAW MD80 ARM 53-02 FIG 18.Dec 8, 2010 · N401NV · Doug MD83 · Fuselage Main, Longeron/StringerSDR WX0A070704Pan · corrodedLEFT AFR SERVICE DOOR PAN FWD LOWER CORNER HAS CORROSION BETWEEN SKIN AND INTERNAL STRUCTURE. REPAIRED CORRODED AREA IAW AAR EA 14223 REV 1/R DATED 06 DEC 2010.Dec 7, 2010 · N401NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070703Door Frame · gougedDOOR JAMB PAN FOR THE FWD ACCESSORY COMPARTMENT GOUGED OUT OF SRM LIMITS IN MULTIPLE PLACES. ACCOMPLISHED PERMANENT REPAIR IAW EA 14227 DATED 07 DEC 2010 REV IR. REPETITIVE INSPECTION PER FAA FORM 8110-32 REF NO 10648 THE SUBJECT REPAIR AS INSTALLED ON THE LDec 7, 2010 · N401NV · Doug MD83 · Fuselage Main, StructureSDR WX0A20101207001Pan · corrodedFWD CARGO DOOR CUTOUT LOWER PAN CORRODED ALONG ENTIRE LENGTH. REPAIRED FWD CARGO DOOR PAN IAW AAR EA 14225 FOR CRACKED AREA AND REMOVED CORROSION FROM PAN AND FOUND TO BE IN LIMITS IAW MD80 SRM 53-01 FIG 01.Dec 7, 2010 · N401NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070701Pan · corrodedLEFT AFT LAV SERVICE DOOR PAN FWD LOWER CORNER HAS CORROSION BETWEEN SKIN AND INTERNAL STRUCTURE. REPAIRED CORRODED AREA IAW AAR EA 14223 REV 1/R DATED 06 DEC 2010.Dec 7, 2010 · N401NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070712Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 6, 2010 · N872GA · Doug MD83 · Emergency LightingSDR 2ARF201012001Engine · making metalACFT RETURNED TO DEPARTURE, DURING CLIMB THE OIL STRAINER CLOGGING LIGHT TURNED ON IN THE LT ENGINE. THE FLIGHT CREW PERFORMED THE OIL STRAINER CLOGGING PROCEDURE, CONFIRMING THE FAILURE AND SHUTDOWN THE ENGINE. DURING MX REVISION, IT WAS DETECTED METAL CHIPSDec 6, 2010 · N848SH · Doug MD83 · Engine (Turbine/Turboprop)SDR 2ARF201012002Drive Unit · damagedCAPTAIN REPORTED THAT DURING CLIMB THE RT UVC AND GENERATOR WERE DISCONNECTED BY HIGH TEMPERATURE; SO THE FLIGHT CREW PERFORMED THE DRIVE GENERATOR MALFUNCTION PROCEDURE, CONFIRMING THE FAILURE AND SHUT DOWN THE UVC AND GENERATOR, CONTINUING TO DESTINATION. DUDec 5, 2010 · N583MD · Doug MD83 · AC Generator-AlternatorSDR WX0A070715Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 3, 2010 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070714Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 3, 2010 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070713Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 3, 2010 · N876GA · Doug MD83 · Emergency LightingSDR 2010F00249Smoke Detector · false activationSMOKE ALARM WENT OFF IN AFT LT LAV LAST 15 MIN OF FLIGHT, NO VISIBLE SMOKE OBSERVED.Dec 3, 2010 · N120MN · Doug MD83 · Smoke DetectionSDR WX0A070690Ballast · failedFLIGHT CREW PERSONNEL REPORTED ON THE GROUND AT STATION TOL, SMOKE AND FUMES COMING OUT OF OVERHEAD SEAT ROW 31 AND 30 A AND C. CONTRACT MAINTENANCE PERSONNEL ACCESSED CEILING LIGHT BALLAST IAW 33-21-03 AND DISCONNECTED CONNECTOR. CONFIRMED BAD BALLAST. DEFNov 28, 2010 · N871GA · Doug MD83 · Passenger Compartment LightingSDR WX0A070692Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 27, 2010 · N407NV · Doug MD83 · Emergency LightingSDR WX0A070696Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 26, 2010 · N416NV · Doug MD83 · Emergency Lighting
Back to Mcdonnell Douglas MD 83