Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2010F00246Pa System · intermittentCOCKPIT PA CUTS OUT WHEN IN USE.Nov 26, 2010 · N836NK · Doug MD83 · Interphone/Passenger Announcement (PA) SystemSDR WX0A070694Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 25, 2010 · N409NV · Doug MD83 · Emergency LightingSDR WX0A070693Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 25, 2010 · N409NV · Doug MD83 · Emergency LightingSDR WX0A070691Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ANov 25, 2010 · N405NV · Doug MD83 · Emergency LightingSDR WX0A070698Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 21, 2010 · N872GA · Doug MD83 · Emergency LightingSDR WX0A070683Skin · corrodedLEFT AFT LAVATORY SERVICE CUT OUT FWD LOWER EDGE OF FUSELAGE SKIN CORRODED. CUT OUT DAMAGED AREA, FABRICATED REPAIR DOUBLER, LOCATED, DRILLED AND INSTALLED REPAIR PARTS IAW MD80 SRM 53-01 AND 53-04 FIG 12B AND AAR EA 14207.Nov 21, 2010 · N869GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A070682Tee Fitting · corrodedFWD STAIRWAY CUT OUT TEE FITTING CORRODED STA 200, LONGERON 20L. REMOVED DAMAGED TEE FITTING, LOCATED, DRILLED AND INSTALLED A REPLACEMENT FITTING IAW MD80 SRM 51-30.Nov 21, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070681Cargo Track · corrodedAFT CARGO PIT LT CARGO TRACK CORRODED STA 1231 TO STA 1287. REMOVED DAMAGED CARGO TRACK, LOCATED, DRILLED AND INSTALLED A REPLACEMENT TRACK IAW MD80 SRM 51-10-4 AND 51-30-1 AND 53-01 FIG 1.Nov 21, 2010 · N869GA · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR 2ARF201011003Skin · dented(2ARF) DURING OVERNIGHT CHECK WAS DETECTED A DENT OF 1.0 X 0.750 INCHES AT LOW FWD OF THE AIRPLANE FRONT LT DOOR. MX EVALUATED THE DENT IAW SRM 53-04, FIG 38, SHEET 18 DETECTING DENT DIMENSIONS IN PERMISSIBLE LIMITS; SO PRESSURIZATION CHECK WAS PERFORMED IAW Nov 21, 2010 · N848SH · Doug MD83 · Passenger/Crew DoorsSDR WX0A070695Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 18, 2010 · N416NV · Doug MD83 · Emergency LightingSDR WX0A070680Seat Track · corrodedCABIN SEAT TRACK CORRODED STA 196 TO STA 313, LBL 22. REMOVED DAMAGED SEAT TRACK, FABRICATED, LOCATED DRILLED AND INSTALLED A REPLACEMENT TRACK IAW MD80 SRM 51-10-4 AND 51-30-01.Nov 18, 2010 · N869GA · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A070697Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 17, 2010 · N419NV · Doug MD83 · Emergency LightingSDR 2WAA20111810Wire · brokenAFTER TAKEOFF, LANDING GEAR DID NOT RETRACT, ACFT WOULD NOT PRESSURIZE.Nov 17, 2010 · N802WA · Doug MD83 · Landing Gear System WiringSDR 2WAA20101110Wire · brokenAFTER TAKE OFF, LANDING GEAR DID NOT RETRACT, A/C WOULD NOT PRESURIZE.Nov 17, 2010 · N802WA · Doug MD83 · Landing Gear System WiringSDR WX0A070679Seat Track · corrodedFWD CABIN FLOOR TRACK CORRODED AT STA 148.5 TO STA 200, LBL 6. REMOVED AND REPLACED FALSE TRACK, FABRICATED, LOCATED DRILLED AND INSTALLED A REPLACEMENT TRACK IAW MD80 53-01 AND 51-10-1 AND 51-30-2 FIG 1 OF THE SRM.Nov 16, 2010 · N869GA · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A070672Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 15, 2010 · N875GA · Doug MD83 · Emergency LightingSDR WX0A070671Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 15, 2010 · N875G · Doug MD83 · Emergency LightingSDR WX0A070670Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 15, 2010 · N875GA · Doug MD83 · Emergency LightingSDR 2ARF201011002Fuel Cell · crackedDURING FUELING, TECH DETECTED A FUEL LEAK IN AFT AUXILIARY TANK DUE TO CRACK IN AFT FUSELAGE BOOT FUEL TANK AROUND INTERCONNECTION TUBE AT STA 2. ACFT WAS SENT TO THE HANGAR AND MX DEACTIVATED THE AFT AUXILIARY FUEL TANK IAW MM 28-20-25, ALL CORRECT.Nov 14, 2010 · N838AM · Doug MD83 · Aircraft Fuel Distribution SystemSDR 2ARF201011001Warning Light · illuminatedACFT RETURNED, DURING CLIMB AT 14,000 FEET, THE FLOW LIGHT TURNED ON AND MESSAGE CABIN ALT WAS SHOWN. MX PERFORMED BOTH A/C PACKS AND PRESSURIZATION VALVES CHECKS IAW MM 21-30-00, NO LEAKS WERE FOUND, RETURN TO SERVICE. THE OVERWEIGHT INSP WAS NOT NECESSARY, ANov 12, 2010 · N838AM · Doug MD83 · Cabin Pressure Control SystemSDR WX0A070661Floor Panel · crackedCABIN FLOOR PANEL EDGES CRACKED OUT STA 313 TO STA 389, LBL 23 TO LBL 44. FABRICATED A REPLACEMENT FLOOR PANEL IAW MD80 SRM 53-05.Nov 11, 2010 · N869GA · Doug MD83 · Fuselage Floor PanelSDR WX0A070660Floor Panel · crackedCABIN FLOOR PANEL B5 CORNERS CRACKED OUT STA 617 TO STA 639, LBL 23 TO LBL 44. FABRICATED A REPLACEMENT PANEL IAW MD80 SRM 53-05.Nov 10, 2010 · N869GA · Doug MD83 · Fuselage Floor PanelSDR WX0A070659Floor Panel · crackedCABIN FLOOR PANEL CORNERS CRACKED PUT PANEL B11 STA 927 TO STA 1003 LBL 23 TO LBL 44. FABRICATED A REPLACEMENT PANEL IAW MD80 SRM 53-05.Nov 10, 2010 · N869GA · Doug MD83 · Fuselage Floor PanelSDR FOTR2016911104Floor Support · corrodedAFT CARGO LEFT FLOOR SUPPORT AT LBL 18 FROM BS. 1174- 1231. REPAIRED NR11104 FASI W/O 20169.Nov 10, 2010 · N831US · Doug MD83 · Fuselage Miscellaneous StructureSDR FOTR2016911107Floorbeam · corrodedAFT CARGO BAY FLOORBEAM BS 1183 IS CORRODED AT LBL 16- RBL 3. REPAIRED ON NR 11107 FASI W/O 20169.Nov 10, 2010 · N831US · Doug MD83 · Fuselage Main, Floor BeamSDR FOTR2016910975Door Frame · corrodedAFT LOWER CARGO COMPARTMENT DOOR JAMB HAS CORROSION. REPAIRED ON NR 10975 FASI W/O 20169.Nov 10, 2010 · N831US · Doug MD83 · Fuselage Main, StructureSDR WX0A070668Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 9, 2010 · N415NV · Doug MD83 · Emergency LightingSDR WX0A070666Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 9, 2010 · N411NV · Doug MD83 · Emergency LightingSDR WX0A070627Apu · malfunctionedFLIGHT CREW PERSONNEL REPORTED DURING TAXI FROM GA RAMP TO THE D GATES IN LAS VEGAS THE LAV SMOKE ALARM WENT OFF AND THE FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE APU IAWNov 5, 2010 · N872GA · Doug MD83 · APU Core EngineSDR WX0A070669Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 4, 2010 · N416NV · Doug MD83 · Emergency LightingSDR WX0A070678Floor Support · corrodedFWD CABIN CENTER FLOOR SUPPORT EXFOLIATED AT FS 198, RBL 10 TO RBL 44. REMOVED AND REPLACED SUPPORT IAW MD80 SRM 53-01 AND 51-10-3 AND 51-30-2.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070677Floor Support · corrodedFWD CABIN FLOOR SUPPORT IS EXFOLIATED AT FS 198, BL 0. REMOVED AND REPLACED SUPPORT IAW MD80 SRM 51-10-3 AND 51-30-5 AND 53-01.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070676Floor Support · corrodedFORWARD CABIN FLOOR SUPPORT IS EXFOLIATED BETWEEN FS 220 AND FS 258 AT LBL 14. REMOVED AND REPLACED FLOOR SUPPORT IAW MD80 SRM 51-30-2.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070675Floor Support · corrodedFWD CABIN FLOOR SUPPORT IS CORRODED AT FS 200 BETWEEN LBL 22 AND LBL 44. REMOVED AND REPLACED SUPPORT IAW MD80 SRM 51-10-3 AND 53-01.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070674Floor Support · corrodedFWD CABIN FLOOR SUPPORT IS CORRODED AT FS 198, LBL 12. REMOVED AND REPLACED SUPPORT IAW MD80 SRM 51-10-3 AND 51-30-2.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A070673Track · corrodedFWD CABIN CENTER FLOOR FALSE TRACK IS EXFOLIATED AT FS 198, RBL 7. REMOVED AND REPLACED TRACK IAW MD80 SRM 53-01 AND 51-30-2.Nov 3, 2010 · N869GA · Doug MD83 · Fuselage Miscellaneous StructureSDR FOTR2016911083Door Frame · corrodedCENTER CARGO DOOR LOWER FRAMES AT STA. 621- 658. REPAIRED ON NR# 11083 FASI W/O# 20169.Nov 3, 2010 · N831US · Doug MD83 · Fuselage Main, StructureSDR FOTR2016911134Floorbeam · corrodedAFT CARGO CABIN FLOORBEAM AT STA. 1309 IS CORRODED AT RBL 20. REPAIRED ON NR 11134 FASI WO 20169.Nov 3, 2010 · N831US · Doug MD83 · Fuselage Main, Floor BeamSDR FOTR2016911132Floorbeam · corrodedAFT CARGO COMPARTMENT, BS. 1309 CABIN FLOORBEAM IS CORRODED ON BOTTOM SURFACE LBL.16 TO RBL.16. REPAIRED ON NR 11132 FASI W/O 20169.Nov 3, 2010 · N831US · Doug MD83 · Fuselage Main, Floor BeamSDR FOTR2016910976Door Frame · corrodedFWD LOWER CARGO DOOR JAMB HAS CORROSION, STA. 408- 427. REPAIRED ON NR 10976 FASI W/O 20169.Nov 3, 2010 · N831US · Doug MD83 · Fuselage Main, StructureSDR WX0A070665Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ANov 1, 2010 · N409NV · Doug MD83 · Emergency LightingSDR WX0A070664Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 1, 2010 · N409NV · Doug MD83 · Emergency LightingSDR WX0A070663Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYNov 1, 2010 · N407NV · Doug MD83 · Emergency LightingSDR WX0A070640Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 30, 2010 · N860GA · Doug MD83 · Emergency LightingSDR WX0A070639ALight · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE AOct 29, 2010 · N874GA · Doug MD83 · Emergency LightingSDR FOTR2016911059Floorbeam · corrodedFLOORBEAM SUPPORT ANGLES CORRODED STA 148- 200 BETWEEN LBL 60 AND RBL 60. REPAIRED ON NR 11059 FASI W/O 20169.Oct 29, 2010 · N831US · Doug MD83 · Fuselage Main, Floor BeamSDR FOTR2016911140Seat Track · corrodedSEAT TRACK STA 1098 LBL 45 CORRODED. REPAIRED ON NR 11140 FASI W/O 20169.Oct 29, 2010 · N831US · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A070626Engine · malfunctionedFLIGHT CREW REPORTED SMOKE IN THE CABIN AND IMMEDIATELY RETURNED TO LAS VEGAS. MAINTENANCE PERSONNEL INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE LEFT ENGINE IAW TASK CARD R804101, OPS AND LEAK CHECK GOOD, AIRCRAFT RETURNED TO SERVICE.Oct 28, 2010 · N872GA · Doug MD83 · Engine (Turbine/Turboprop)SDR WX0A070648Vane · gougedRIGHT WING OUTBOARD FLAP INBOARD VANE LEADING EDGE IS GOUGED IN 2 PLACES. REPAIRED RIGHT WING O/B FLAP I/B VANE IAW MD80 SRM 57-03 PG 27.Oct 27, 2010 · N865GA · Doug MD83 · Trailing Edge FlapsSDR WX0A070638Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND BATTEROct 27, 2010 · N886GA · Doug MD83 · Emergency Lighting
Back to Mcdonnell Douglas MD 83