Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ANCF200200025Switch · malfunctionedWITH AUTO SPOILERS DISARM, AUTO BRAKES SELECTOR IN OFF AND AUTO BRAKES SWITCH IN DISARM, WHEN THROTTLES WERE ADVANCED FOR TAKE OFF, "AUTO BRAKES TAKE OFF WARNING" CONFIGURATION CAME ON. TAKE OFF WAS ABORTED. REJECTED TAKE OFF SWITCHES WERE ADJUSTED PROPERLY INov 13, 2002 · N190AN · Doug MD83 · Drag Control SystemSDR ASAA0280513Connector · disconnectedSEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED LOOSE CONNECTION. LIGHTS THEN OPERATED PROPERLY. (M)Nov 1, 2002 · N981AS · Doug MD83 · Emergency LightingSDR ZW0A0210901Module · inoperativeTHE EGRESS LIGHTS WERE INOPERATIVE FROM SEAT ROW 26 TO 28. REPLACED LAMP MODULE ASSEMBLY.Oct 28, 2002 · N9630A · Doug MD83 · Emergency LightingSDR GTIA021314Arm · bentFTW - COULD NOT GET GEAR LIGHT TO TURN FROM RED TO GREEN WHEN USING EMERGENCY GEAR EXTENSION BOTH PRESSURIZED AND UNPRESSURIZED HYDRAULICS. REMOVED SHAFT, SPRING, RETAINER BLOCK, SUPPORT AND ARM. UPON FURTHER INSPECTION FOUND ARM BENT, BEARINGS WORN IN SPRINOct 25, 2002 · N822NK · Doug MD83 · Landing Gear Retraction/Extension SystemSDR ZW0A0210801BatteryTHE EGRESS LIGHTS WERE INOPERATIVE FROM CABIN ROWS 20 TO 25. REPLACED THE BATTERIES IN THE BATTERY PACK. CHECK-C 8-23-02 STL. --CLOSED--Oct 24, 2002 · N9412W · Doug MD83 · Emergency LightingSDR ZW0A0210603Battery Pack · dischargedFOUND OVERWING EMERGENCY LIGHTS AND TWO EGRESS LIGHTS INOPERATIVE. REPLACED THE OVERWING LIGHT BATTERY PACK AND TWO EGRESS LAMPS.Oct 17, 2002 · N9420D · Doug MD83 · Emergency LightingSDR ANCF200200022Hose · looseRT AIRSPEED INDICATOR INOPERATIVE. IT WAS FOUND LOOSEN HOSE IN CADC. IT WAS ADJUSTED PROPERLY AND PERFORMED TEST IAW AMM.Oct 14, 2002 · N632CT · Doug MD83 · Airspeed/Mach IndicatorSDR ANCF200200021Acm · damagedFIVE MINUTES AFTER TAKE OFF IT WAS FELT SMOKE SMELL FROM AIR CONDITIONING TUBES. AIRCRAFT RETURNED BACK TO BOGOTA. FLIGHT PERFORMED ON EI-CCC. AIRCRAFT WAS LEFT ON GROUND FOR WORKING ON IT AT NIGHT. THE RIGHT PACK AIR CYCLE MACHINE WAS FOUND BINDING. THE AIOct 10, 2002 · N190AN · Doug MD83 · Cabin Cooling SystemSDR MEX2002311O-Ring · damagedFLT 509 - MEX-VSA - AIRCRAFT PERFORMED AN EMERGENCY DESCENT AND UNSCHEDULED LANDING AT MEX DUE TO LOSS OF HYDRAULIC FLUID INTO THE RIGHT SYSTEM. TECHNICAL PERSONNEL VERIFIED THE SYSTEMS, RIGHT SYSTEM WAS EMPTY. HYDRAULIC LIQUID WAS RECHARGED TO VERIFIED SYSTSep 27, 2002 · N861LF · Doug MD83 · Rudder Control SystemSDR CA021010005Wheel · cracked(CAN) DURING THE OVERHAUL OF THE MAIN WHEEL ASSEMBLY THE NDT INSPECTION WAS DETECTED A CRACK ON THE UPPER SPOKE AREA. THE CRACK WAS UNDETECTABLE WITH THE DYE PENETRANT, BUT DETECTABLE WITH EDDY CURRENT.- NOREPAIR POSSIBLE.Sep 27, 2002 · Doug MD83 · Wheel/Ski/FloatSDR GTIA021125Longeron · corrodedAFT PIT, CORROSION FS 1250-1271 LONG 28R, LWR SIDE CORRODED AT SPLICE. REMOVED DAMAGED SECTION, DRILLED NEW LONGERON, FABRICATED LONGERON SPLICE, INSTALLED SPLICE AND LONGERON SECTION.Sep 24, 2002 · N808NK · Doug MD83 · Fuselage Main, Longeron/StringerSDR ASAA0280289Light · inoperativeSEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY (INCLUDING BATTERY PACK). LIGHT THEN OPERATED NORMALLY. (M)Aug 31, 2002 · N982AS · Doug MD83 · Emergency LightingSDR ANCF200200018Duct · leakingDURING CLIMB AT FL180, THE FLOW LIGHT CAME ON AND THE CABIN ALTITUDE WAS INCREASING. IMMEDIATELY DESCENT WAS PERFORMED TO FL100, BUT THE FLOW LIGHT REMAINED ON UNTIL FL100 WAS REACHED. THE AIR LEAK FOUND IN LT DUCT THERMOSTAT WAS CORRECTED. SOME CLAMPS IN LAug 28, 2002 · N583AN · Doug MD83 · Air Distribution SystemSDR ASAA0280279Light · inoperativeSEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED PORTABLE LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)Aug 26, 2002 · N981AS · Doug MD83 · Emergency LightingSDR ASAA0280327Battery · failedLAX - JUST PRIOR TO PUSH BACK, SMOKE WAS NOTED DISCHARGING FROM VENT HOLES AFT OF THE NLG WHEEL WELL. THE SMOKE WAS DETERMINED TO BE STEAM DISCHARGING FROM THE MAIN BATTERY VENT HOLES. SUBSEQUENT SHOP INVESTIGATION REVEALED THAT BOTH MAIN BATTERIES S/N'S 930Aug 13, 2002 · N981AS · Doug MD83 · Battery/Charger SystemSDR ANCF200200016Pin · damagedDURING APPROACH LEFT INBOARD ANTISKID ANNUNCIATION CAME ON, ABNORMAL CHECK LIST WAS PERFORMED AND IT WAS UNSUCCESFULL.DUE TO SHORT RUNWAY IN PEREIRA CREW RETURNED TO BOGOTA. ANTI-SKID CCONTROL TEST AND ANTI-SKID CONTROL BOX BITE WERE PERFORMED IAW AMM 32-43-00Aug 1, 2002 · N632CT · Doug MD83 · Tire TubeSDR GTIA020862Generator · failedDTW - FLT 706 - AFTER TAKEOFF OVER MILE AREA, LEFT GEN FAULT FEEDER AND GEN BUS AND X-TIE LIGHT CAME ON, QRH FOLLOWED. FOUND LEFT GENERATOR BAD. ON GENERATOR T5 TO T6 READ .5 OHMS WHICH FAIL GENERATOR. REMOVED AND REPLACED LEFT POWER RELAY FOR PRECAUTIONARYJul 29, 2002 · N822NK · Doug MD83 · AC Generation SystemSDR GTIA020861Gcu · malfunctionedDTW - FLT 874 - AT CRUISE, RECEIVED THE AC CROSSTIE LOCKOUT LIGHT, LT FLIGHT FAULT AND LT GEN OFF LIGHT ON AFTER REINSTALLING POWER TO THE LT AC SYSTEM WITH THE APU PER OUR QRH. UNABLE TO RESTORE LEFT GENERATOR POWER. REMOVED AND REPLACED GENERATOR CONTROL UJul 18, 2002 · N822NK · Doug MD83 · AC Generation SystemSDR ANCF200200014Valve · failedAFTER T/O THE NLG DID NOT GO UP. PROCEDURES CHECKLIST WERE ACCOMPLISHED. AIRCRAFT WAS TURNED BACK TO BOGOTA. AIR VALVE WAS REPLACED. WAS ACCOMPLISHED SERVICE ON SHOCKSTRUT AND PERFORMED RETRACTION TEST IAW AMM 32-30-00 PAG 1. RESULTS SATISFACTORY.Jul 13, 2002 · N190AN · Doug MD83 · Landing Gear Retraction/Extension SystemSDR GTIA020785Cowling · peelingDTW - NR 2 ENGINE NOSE COWL, INLET LINER, METAL MESH PEELING AT 12 O'CLOCK POSITION. REPAIRED WIRE MESH ON NR 2 ENGINE, INLET COWL IAW MD80 SRM 54-04. (M)Jul 10, 2002 · N822NK · Doug MD83 · Nacelle/Pylon, Plate/SkinSDR MEX2002258Computer · failedAIRCRAFT RETURNED TO PLATFORM AS DUE TO AUTO SLAT FAIL LIGHT ON, BOTH STALL WARNING COMPUTERS WERE FOUND WITH FAILURES, PROXIMITY SWITCH AND "C" AND "D" SENSORS WERE TESTED AND FAIL CONTINUE. EXCESSIVE GREASE WAS DETECTED IN OUTBOARD SLATS ACTUATORS. ACTUATOJul 8, 2002 · N945AS · Doug MD83 · Stall Warning SystemSDR ANCF200200012Proximity Sensor · malfunctionedDURING TAKE OFF ROLL, GEAR DOOR OPEN ANNUNTIATION CAME ON. TAKE OFF WAS ABORTED. WAS ADJUSTED AND CLEANED DOOR PROXIMITY SENSOR IAW AMM 32-60-00. WAS PERFORMED BITE ON PSEU IAW AMM 32-60-04 PARAGRAPH 1C, PAGE 201. RESULTS SATISFACTORY.Jun 27, 2002 · N190AN · Doug MD83 · Landing Gear Position and WarningSDR GTIA020724Wire · chafedDTW - FOUND WIRES CHAFED IN AFT ACC COMPARTMENT AT TAILCONE JETTISON HANDLE LIGHT ASSEMBLY. SECURED CHAFING WIRES AFT ACC COMPARTMENT IAW MD80 MM 20-50-02 AND REPLACED CHAFFED WIRES. OPS CHECK GOOD. (M)Jun 25, 2002 · N822NK · Doug MD83 · Light System WiringSDR ZW0A0206402Acm · leakingA BURNING ODOR WAS IN CABIN AND COCKPIT ON DESCENT. NO SMOKE. FOUND RT ACM OIL PUDDLING IN ACM OUTLET. THE NEXT STATION REPLACED THE RT ACM.Jun 16, 2002 · N9413T · Doug MD83 · Cabin Cooling SystemSDR ASAA0280208Connector · looseLAS - DURING PREFLIGHT CHECK, EMERGENCY TRACK LIGHTING IN AFT CABIN WAS FOUND TO BE INOPERATIVE. RECONNECTED LOOSE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)Jun 15, 2002 · N981AS · Doug MD83 · Emergency LightingSDR ANCF200200011Coalescer Bag · dirtyAFTER TAKE OFF A STRONG SMOKE SMELL WAS PRESENTED IN THE COCKPIT, INMEDIATELY, THE CABIN SUPPERVISOR INFORMED THAT THERE WAS A STRONG SMOKE SMELL ALONG THE PASSENGER CABIN, SPECIALLY IN THE REAR SECTION. THERE WAS NOT FUMES NOR FIRE VISIBLE AT ANY MOMENT. WE RJun 9, 2002 · N632CT · Doug MD83 · Humidity Control SystemSDR MEX2002205Sensor · failedAIRCRAFT RETURN TO FLIGHT AS A CONSEQUENCE OF STABILIZERS MOVEMENT ALARM, STABILIZER MOVEMENT SENSOR WAS REPLACED, TESTS WERE PERFORMED IAW MM.Jun 3, 2002 · N946AS · Doug MD83 · Stabilizer Control SystemSDR ASAA0280190Door Frame · corrodedPAE - DURING C-CHECK, FOUND MID CARGO BAY LOWER DOOR BEAM TO BE CORRODED ON VERTICAL FACE AND LOWER HORIZONTAL LUG. REPAIRED PER EA 5310-02090. (M)May 24, 2002 · N982AS · Doug MD83 · Fuselage Main, StructureSDR ASAA0280188Skin · bentPAE - DURING C-CHECK, FOUND FORWARD PAX ENTRANCE DOOR SKIN BENT ALONG FORWARD BOTTOM EDGE. REPAIRED PER SRM 52-05, FIG 37. (M)May 23, 2002 · N982AS · Doug MD83 · Passenger/Crew DoorsSDR ASAA0280186Spacer · corrodedPAE - DURING C-CHECK, FOUND CORROSION ON AFT CARGO BAY THRESHOLD SPACER AT FS 1160-1207. REPAIRED PER EO 5300-0101. (M)May 20, 2002 · N982AS · Doug MD83 · Fuselage Miscellaneous StructureSDR GTIA020516Connector · looseFLL - FLT 1440 - AT 30,000 ON CLIMB-OUT, LT ENGINE GENERATOR DROPPED OFFLINE, CROSSTIE LOCKOUT LIGHT ON LT GEN FEEDER FAULT LIGHT ON LT GEN OFF LIGHT ON LOSS OF CONT LT AC BUS POWER OCCURRED. FOLLOWED QRH, DESCENDED TO 24,000, THE APU FINALLY STARTED. QRH CRMay 20, 2002 · N822NK · Doug MD83 · AC Generation SystemSDR GTIA020517Headset · overheatedDEN - FLT 970 - MIC ON CAPTAIN HEADSET OVERHEATED AND IS INOPERATIVE. SMELLS BURNED AT SWIVEL ATTACHMENT. REMOVED AND REPLACED MIC-HEAD SET. OPS CHECKS NORMAL. (M)May 18, 2002 · N822NK · Doug MD83 · Audio Integrating SystemSDR ASAA0280178Module · disconnectedPDX - DURING LINE CHECK, DISCOVERED EMERGENCY TRACK LIGHTS AT ROW 10-15 WERE INOPERATIVE. RECONNECTED LAMP HOLDER MODULE. LIGHTS THEN OPERATED PROPERLY. (M)May 16, 2002 · N981AS · Doug MD83 · Emergency LightingSDR ANCF200200010CsdDURING CLIMB RIGHT CSD OUTLET TEMP HIGH WAS PRESENTED, CHECK LIST WAS PERFORMED AND THE RIGHT CSD DOESN’T DISCONNECTED, ALSO THE A.P.U. DID NOT START AT THE AND ALTITUDE OF 20000. THE CREW DECIDED TO TURN BACK TO CTG THE RIGHT CSD OIL PRESS LOW ANN CAME ON TROMay 16, 2002 · N583AN · Doug MD83 · Alternator-Generator DriveSDR MEX2002121Computer · failedFLT 935 - MTY-MEX - BOTH FMA'S OUT OF SERVICE WITH THE DFGC SWITCH IN THE NR 2 POSITION. PERFORMED A RESET TO THE ELECTRIC BARS, DFGC 1 DID NOT PERFORM THE POWER UP UNTIL THE DFGC SWITCH WAS CHANGED. THE COPILOT ADI WAS CHANGED BUT DID NOT CORRECT THE PROBLEApr 23, 2002 · N861LF · Doug MD83 · Flight Management Computing Hardware SystemSDR ZW0A0204301Connector · looseTHE FIRST CLASS EGRESS LIGHTS WERE INOPERATIVE. RECONNECTED LOOSE CONNECTION.Apr 17, 2002 · N951TW · Doug MD83 · Emergency LightingSDR MEX2002101Control Valve · failedFLT 583 - MEX-CUN - WHEN THE AIRCRAFT GETS PLATFORM BY ITSELF THE RIGHT GYRO WAS EXCEEDED AND THE ACTUATORS WERE STUCK. AIRCRAFT WAS SENT TO THE HANGAR AND THE STEERING CONTROL VALVE WAS CHANGED IAW MM 32-52-01. (M)Apr 7, 2002 · N945AS · Doug MD83 · Landing Gear Steering SystemSDR ASAA0280139Lanyard · detachedPHX - DURING PREFLIGHT CHECK, L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)Apr 2, 2002 · N981AS · Doug MD83 · Escape SlideSDR ASAA0280119Light · out of positionSEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE AT ROWS 6 THROUGH 9. RECONNECTED (REPOSITIONED) LIGHT MODULES. LIGHTS THEN OPERATED PROPERLY. (M)Mar 30, 2002 · N982AS · Doug MD83 · Emergency LightingSDR GTIA020250Limiter · lack of lubeFLT 198 - ACY - RUDDER TRAVEL UNRESTRICTED LIGHT DID NOT COME ON DURING FINAL APPROACH UNTIL SLOWING TO BELOW 150 KIAS. CLEANED RUDDER PITOT DRAIN SUMP AND LUBRICATED RUDDER LIMITER SYSTEM IAW MD80 27-20-00. NO DEFECTS NOTED. CLEANED PROXIMITY SENSOR IAW 27Mar 27, 2002 · N822NK · Doug MD83 · Rudder Control SystemSDR ANCF200200005Csd · failedAFTER TAKE OFF ROLL DURING CLIMB. PRIOR TO CLIMB THRUST REDUCTION IN ANNUNCIATOR PANEL, RIGHT CSD OIL PRESSURE LOW AND RIGHT GENERATOR OFF APPEARS. WAS PERFORMED THE RESPECTED MALFUNCTIONS PROCEDURE AND CHECK LIST. THE CREW RETURNED TO EDR. THE RIGHT CSD WAS Mar 10, 2002 · N632CT · Doug MD83 · AC Generation SystemSDR ZW0A0202801Battery · dischargedDURING PREFLIGHT THE FIRST CLASS EGRESS LIGHTS FLASHED DURING TEST. THEY DID NOT REMAIN ON. REPLACED THE BATTERIES IN THE POWER SUPPLY.Mar 9, 2002 · N9630A · Doug MD83 · Emergency LightingSDR ASAA0280066Connector · disconnectedPDX - DURING LINE CHECK, FOUND 5 EMERGENCY TRACK LIGHTS INOPERATIVE, ROWS 6 TO 8. RESECURED ELECTRICAL CONNECTORS. LIGHTS THEN OPERATED PROPERLY. (M)Mar 8, 2002 · N982AS · Doug MD83 · Light System WiringSDR GTIA020214Linkage · lack of lubeRSW - FLT 1525A - FOUND RUDDER TRAVEL UNRESTRICTED LIGHT DID NOT COME ON UNTIL AIRCRAFT TOUCHED DOWN. SPEED ON FINAL WAS 104 K. LUBRICATED BEARINGS IN CONTROL LINKAGES AND ADJUSTED RIGGING ON RUDDER THROW LIMITER SYSTEM. ALL WORK IAW MD80 MM 27-20-00. (M)Mar 2, 2002 · N822NK · Doug MD83 · Rudder Control SystemSDR AALA20020204Charger · defectiveOKC - FLT 9680 - AFTER TAKEOFF OKC, SHIP BATTERY CHARGER CIRCUIT BREAKER POPPED. RETURNED OKC AND LANDED WITHOUT INCIDENT. REPLACED MAIN SHIP BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Feb 27, 2002 · N834RA · Doug MD83 · Battery/Charger SystemSDR ANCF200200004Line · brokenDURING CLIMB TO BOGOTA, THE CREW NOTICED THAT THE RT HYDRAULIC QUANTITY DROPPED TO 4 QTS, WITH PUMP IN LOW AND OFF OPERATION. THE SYSTEM WAS DEPRESSURIZED AND THE QUANTITY AUGMENTED TO 7 QTS. DURING CRUISE RH HYDRAULIC QUANTITY MAINTAINED IN 7 QTS, HOWEVER DURFeb 22, 2002 · N583AN · Doug MD83 · Hydraulic System, MainSDR ZW0A0202201ComputerTHE CAPTAIN'S IAS INDICATOR FROZE AT 180 KNOTS ON CLIMB OUT. CREW MADE AN UNSCHEDULED LANDING AT MCI. REPLACED THE CAPTAIN'S AIR SPEED INDICATOR, PN 4057800-906, AND THE NUMBER 1 CADC. CHECK-C 7-29-01 STL. --CLOSED--Feb 21, 2002 · N9413T · Doug MD83 · Airspeed/Mach IndicatorSDR MEX2002044Hydraulic Line · leakingFLT 448 - BJX-LAX - DURING RAMP INSPECTION IT WAS DETECTED AN HYDRAULIC LEAK IN THE RIGHT MLG COMPARTMENT. A PRESSURE LINE OF THE BRAKE MANIFOLD AND MANIFOLD SEAL CAP WAS REPLACED IAW MM 32-42-03, IPC ITEM 102, TEST OK. 5 QUARTS OF HYDRAULIC FLUID WERE NEEDEFeb 16, 2002 · N945AS · Doug MD83 · Hydraulic System, MainSDR MEX2002037Gyro · failedFLT 443 - HMO-MZT - AIRCRAFT RETURNED TO PLATFORM AS CONSEQUENCE OF ANTI-SKID LIGHTS AND FLAG ON ATT IN ADI RIGHT. SWITCH S1-130 WAS CLEANED AND VERTICAL GYRO WAS REPLACED, FAIL WAS CORRECTED, TESTS OK. THE S1-130 SWITCH WAS REPLACED AND ANTI-SKID SYSTEM WASFeb 12, 2002 · N946AS · Doug MD83 · Attitude Gyro and Indicating SystemSDR MEX2002030Blade · damagedFLT 227 - CJS-MEX - DURING TRANSIT CHECK, DETECTED DAMAGES TO 28 BLADES OF THE NR 1 ENGINE. C1 DISK WAS REPLACED IAW MM 72-20-33 AND TESTS WERE PERFORMED IAW MM 71-00-00. (M)Feb 6, 2002 · N831LF · Doug MD83 · Turbine Engine Compressor Section
Back to Mcdonnell Douglas MD 83