Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019040202079Shutoff Valve · leakingSHIP 0981 -(HYD) ALT GEAR EXT - RIGHT HYDRAULIC PRESS WENT TO ZERO WITH QUANTITY AT 1. COMPLIED WITH QRH PROCEDURES. CREW USED ALTERNATE GEAR EXTEND. RUDDER HYDRAULIC SHUTOFF VALVE FOUND LEAKING. REPLACED VALVE PER MD88 AMM.SDR REPORTED DUE TO AN EMERGENCY BESDR DALA2019033102053Light · inoperative1ST EMERGENCY ESCAPE PATH LIGHT AFT OF AFT ENTRY DOOR DAMAGED INOP. REPL LIGHT ASSY PER AMM 33-53. OPS CHECK GOOD. (LP4882856)SDR DALA2019033102054Skin · damagedDAMAGE AFT OF NR 2 ENG PYLON AT UPPER LEFT CORNER OF EMEGENCY EXIT STENCIL. ACCOMPLISHED ERA 576838-14 REV ORIG. STOP DRILLED CRACKS. REMOVED DAMAGE, FABRICATED DOUBLER, AND BEGAN INSTALLATION PER SRM 53-04-3 FIG 2 SHT 3. CLASS 2 REPAIR. COMPLETED INSTALLATIONSDR DALA2019033002044Actuator · leakingSHIP 904 - (HYD) RIGHT HYDRAULIC QUANTITY WENT TO 0 IN CRUISE. PERFORMED QRH 3-13 AND 13-23. USED ALTERNATE GEAR EXTEND PER THE QRH. CORRECTIVE ACTION: FOUND RIGHT MAIN LANDING GEAR RETRACT ACTUATOR LEAKING. REPLACED ACTUATOR PER AMM. SDR REPORTED DUE TO EMERGSDR DALA2019033002043Skin · damagedINITIAL INSPECTION: CREASE ON FUSELAGE SKIN BTW STA Y=1265 AND Y =1277 BTW LONG 27L AND 28R. FUSELAGE SKIN BTW STA Y=1265 AND Y=1277 BTW LONG 27L AND 28R WAS REPAIRED PER ER/A 576844-14 REV.: ORIG. SEC.: I AND ETI-88-19-030 REV: ORIG. ACCOMPLISH SECTION II REPSDR DALA2019032901994Battery Pack · dischargedEMERGENCY LIGHTS INOP ROWS 1-12. REMOVED AND REPLACED BATTERY PACK AT LOCATION B5-211 AND PERFORMED OPS CHK OF EMERGENCY ESCAPE PATH LIGHTING AS PER AMM 33-53. CHECKS OK. (LP5759083)SDR DALA2019032901991Paint · damagedINITIAL INSPECTION: MISSING AND DAMGE PAINT ON RUDDER CONTROL TAB. TAB WAS REMOVED/INSTALLED PER AMM 27-20-02-401. PAINTED PER P.S. 900-3-6-NO36 AND BALANCED PER SRM 55-40-01. (LP1006583)SDR DALA2019033102056Skin · dentedFUSELAGE SKIN STA Y=1250-1287 & L27L TO L28R DENTS & SCRATCHES. ACCOMPLISH ER/A 576844-14 SECTION II INSPECTION WITHIN EVERY 8000 CYCLES AFTER ACCOMPLISHMENT OF THE SECTION I REPAIR. (LP1007252)SDR DALA2019032901995Cable · burnedDURING WAKE UP CHECK LIST AMP INDICATION NO SHOW. ELECTRICAL CABLE P44A24 AND C/B WERE FOUND BURNED, CABLE AND C/B B1-171 WERE REPLACED PER MD88 SWPM 20-10-06 AMD AMM 24-00-00. TEST WAS PERFORMED PER AMM 24-30-02 TEST OK. (LP4883756)SDR DALA2019032801990Fastener · looseAWR. IN REFERENCE AMDS 5530-01045-05 STEP 2 LOOSE FASTENERS WAS FOUND ON VERTICAL STABILIZER LEADING EDGE STA ZFS: 52.26. FASTENERS ON VERTICAL STABILIZER LEADING EDGE STA ZFS: 52.26 WERE REPLACED PER ETI-88-19-028 REV.2 AND ERA 576759-14AD REV. ORIGINAL. SECTSDR DALA2019032701929Spar · crackedVERTICAL STABILIZER LT SIDE LEADING EDGE SPAR CHORD CRACK REPAIR / AMOC 17-088ER/A 557950-14AD REV A SUPPLEMENTAL INSPECTION RESTRICTION: ACCOMPLISH SECTION II: SUPPLEMENTAL INSPECTIONS, AT ACCRUEMENT OF 63,615 TOTAL AIRCRAFT FLIGHT CYCLES, AND EVERY 4,500 FLISDR DALA2019033102055Skin · damagedFUSELAGE SKIN AFT LAV SERVICE DOOR CUTOUT STA Y=1307-1322, L-22L SKIN & INTERNAL DOUBLER/ CORROSION. ACCOMPLISH ER/A 576847-14 SECTION II INSPECTION WITHIN EVERY 3000 CYCLES UNTIL SECTION III IS ACCOMPLISHED WITHIN 8000, ALL AFTER ACCOMPLISHMENT OF SECTION I. SDR DALA2019032901993Skin · damagedSTABILIZERS VERTICAL FIXED LE SKIN, ZFS. ELONGATED HOLES. DTA MONITOR INSPECTION LOG REFERENCE ER/A 576759-14AD SECTION II REQUIRES DTA APPROVAL ON OR BEFORE THE NEXT 24 MONTHS. DISCONTINUE REVENUE SERVICE ON OR BEFORE THE NEXT 24 MONTHS PENDING A DAMAGE TOLERSDR DALA2019032601912Light · inoperativeEMERGENCY LIGHT AT 22ED INOP. REPLACED LIGHT AND HARNESS ASSY OPS NML REF AMM 33-53. (LP5058053)SDR DALA2019032601913Oven · malfunctionedSHIP 9008 - ATB - RETURNED TO ATL DUE TO SMOKE DETECTOR IN FORWARD LAVATORY ACTIVATED ALONG WITH STRONG SMELL ON TAKE-OFF AT 300FT. CORRECTIVE ACTION: WHILE WORKING NO GO ODI WORK CARD 2120-2367 FOUND OVEN PRODUCING ODOR DESCRIBED ON SMOKE AND FUMES QUESTIONNASDR DALA2019032601911Doubler · crackedINITIAL INSPECTION: CRACK ON DOUBLER REPAIR OF LEADING EDGE BTW XRS= 190 AND XRS= 210 LT WING. DOUBLER REPAIR OF LEADING EDGE BTW XRS= 190 AND XRS= 210 LT WING WAS REPLACED PER ETI-88-19-026 REV. ORIGINAL AND ER/A 532516-14 REV A SECTION III. (LP1001760)SDR DALA2019032501888Wire Harness · brokenEMERGENCY LIGHTS AT 35ED NOT WORKING. FOND HARNESS BROKEN. REPLACED OPS NML. REF AMM 3352. (LP5845514)SDR DALA2019032501889Unknown · odorDEPARTED AND SMELLED BAD ODOR DIVERTED TO MCI AFTER DELARING AN EMERGENCY NORMAL LANDING. OPENED BORESCOPE INSPECTION PORTS REF AMM 72-00-00-290-801C1. BORESCOPED 6TH STAGE 7TH STAGE 13TH STAGE ALSO INSPECTED INLET NO DAMAGE NOTED. CLOSED BORESCOPE INSPECTION SDR DALA2019032501887Spacer · corrodedINITIAL INSPECTION: CORROSION AT SPACER OF THE CENTER LOWER CARGO DOOR JAMB BEAM. (CORROSION LEVEL 2): SPACER WAS REPLACED PER SRM 53-05 FIG 123A (SHEET1). (LP1000032)SDR DALA2019032401884Light · inoperativeFA IN FWD GALLEY CALLED ON SHORT FINAL THAT THERE WAS AN ELECTRICAL BURNING SMELL THAT SHE NOTICED. ALSO, A PASSENGER IN ROW 3 GOT OUT OF HER SEAT TO ASK THE FA ABOUT THE SMELL THAT SMELLED BURNING. WE LANDED MOMENTS LATER AND THE FUMES WERE GONE. FA STATED THSDR DALA2019032301881Light · inoperativeEMERGENCY LIGHTS AT 14D & 36D INOP. RELAMPED BOTH LIGHTS OPS CKS PER AMM 33-50. (LP3412955)SDR DALA2019032301883Doubler · wornINITIAL INSPECTION : WEAR ON REPAIR DOUBLER AT EXT USELAGE SKIN FWD PASSENGER DOOR ( L1 ) PROJECTION LONG 16/ 15L AT FUSELAGE. REPAIR DOUBLER AT EXT FUSELAGE SKIN FWD PASSENGER DOOR, PROJECTION LONG 16/ 15L WAS REPLACED PER SRM 52-05 PAR. 17 FIG. 20A. (LP09970SDR DALA2019032301882Connector · damagedSEAT 13DE AND 21DE EMERGENCY PATH LIGHTS INOP. REPAIRED CONNECTORS, REF SWPM 20-90. NOW CHECKS GOOD. (LP5845377)SDR DALA2019032201843Skin · wornWEAR AT UPPER PREVIOUS REPAIR SKIN ON INTERNAL VANE GUIDE AT OUTBOARD FLAP RT WING. INTERNAL VANE GUIDE AT OUTBOARD FLAP RT WING WAS REPAIRED PER SRM 57-03D. (LP0995827)SDR DALA2019032101834Terminal Block · burnedBEFORE PUSHBACK EXT. PWR WAS PULLED. ALL ELECT POWER REMOVED FROM JET. RESTORED EXT PER. AFTER PUSH, BEGINNING TAXI, GALLEY PER SHREDDED. STRONG ELECTRICAL SMELL OBSERVED FROM CB PANEL BEHIND CAPTAINS SEAT. NO SMOKE OBSERVED. FOUND TERMINAL BLOCK S3-263 BURNEDSDR DALA2019032001827Power Supply · inoperativeEMERG. LIGHTS IN CEILING OUT STA 446-586. REPLACED PWR SUPPLY B5-101 IAW AMM 33-53. NOW CK GOOD. (LP5764876)SDR DALA2019032001828Slide · damagedL1 DOOR GIRT BAR HUNG ON DOOR FRAME. FOUND SLIDE PACK DAMAGED DID NOT DEPLOY. REPLACED L1 DOOR SLIDE PACK PER 2561-01358-01A. SLIDE, EVAC, FO OFF 97-2561-9-0003 02768 ON 88-2560-9-0003 03673. (LP5813124)SDR DALA2019032001826Lanyard · unsecureTAILCONE KEVLAR LANYARD LOOP NOT SECURED TO RELEASE CAM. REINSTALLED KEVLAR LANYARD LOOP TO RELEASE CAM PER AMM 53-53. VERIFIED LANYARD INSTALLED. (LP5741857)SDR DALA2019031801768Fire Warning · false activationAFT CARGO FIRE WARNING. VERIFIED NO SMOKE/FIRE AFT CARGO PER MCC R/R REF AMM 26-14. ALL OPS NML (LP5885780)SDR DALA2019031801766Battery Pack · dischargedAFT CAT WALK TAIL CONE EMERGENCY LIGHT INOP. REMOVED AND REPLACED AFT REAR BATTERY PACK. IAW AMM 35-33 OPS CHECK OK. PN AD4002P. (LP5765082)SDR DALA2019031801765Battery Pack · dischargedL & R AFT EMERGENCY UPPER EXIT LIGHTS INOP. REMOVED & REPLACED ASSOCIATED BATTERY PACK LTS PER AMM 33-53. OPS CHECK GOOD. (LP5516259)SDR DALA2019031801764Spacer · corrodedINITIAL INSPECTION: CORROSION AT SPACER OF THE AFT LOWER CARGO DOOR JAMB BEAM. (CORROSION LEVEL 2): SPACER OF THE AFT LOWER CARGO DOOR JAMB BEAM WAS REPLACED PER SRM 53-05 FIG. 123. (LP0990137)SDR DALA2019031701762Fuse · blownF/C EMERG LIGHTS INOP. REPLACED FUSES ON BATTERY PACK PER AMM 33-53. CKS GOOD. A/C OK FOR SVC. (LP5733058)SDR DALA2019031701761Skin · crackedON WALK AROUND FOUND 2 CRACKS LEFT SIDE STA 1265.603 6" ABOVE AFT AIRSTAIR DOOR CUTOUT. INSTALLED PERM REPAIR PER SRM 53-01 PAGE 12 FIG 2. (LP5835229)SDR DALA2019031701760Skin · delaminatedAWR IN REF, MON/916/012-MON, 88 REP, 2855432. DELAMINATED WAS FOUND ON RT OUTBOARD FLAP, MID FLAP VANE UPPER SKIN (AD). RT OUTBOARD FLAP, MID FLAP VANE UPPER SKIN WAS REPAIRED PER SRM 57-03D PAR.11 B (2) AND (UT) TAP-TEST INSPECTION WAS ACCOMPLISHED ON RT OUTBSDR DALA2019031701763Power Supply · inoperativeON WAKE UP CK FOUND ROW 31 AND AFT EMERGENCY LIGHTS INOP. REPLACED BATTERY, NO HELP PER AMM 33-53. REMOVED AND REPLACED POWER SUPPLY P/N RPS1B S/N 1093 OK:P/N 11-0049 S/N 8243 OFF. EMERGENCY LIGHTS CK GOOD. OK OFR SVC PER AMM 33-53. (LP5311048)SDR DALA2019120907158Skin · tornFUSELAGE/ SKIN/ C-3 DOOR CUTOUT/ AFT EDGE: REPAIR OF EDGE TEAR - PERMANENT REPAIR ACCOMPLISHMENT. ACCOMPLISHED SECTION III OF ERA 271005-14 REV E NO FURTHER DAMAGE NOTED. REF LOG PG 1386582 AS TRACKING SECTION IV PERMANENT REPAIR REQ PER ERA 2710050-14 REV E. SDR DALA2019031501702Bracket · brokenWHILE WORKING JOB CARD 0591-0301 FOUND AUX HYD PUMP WIRE HARNESS BRACKET BROKE. REF EA 09-457000-03AD FIG 2 ITEM 7. INSTALLED BRACKET TO WIRE HARNESS PER EA 09-457000-03AD FIG 2. A/C OK FOR SVC. BRACKET 9D0062-3S10-12. SDR REPORTED DUE TO BEING AD RELATED. (LPSDR DALA2019031501701Skin · crackedINITIAL INSPECTION: CRACK AND GOUGE ON FUSELAGE SKIN ON JACK POINT HOLE BETWEEN LONGERONS 30 AND 29R STA. 218. PERMANENT REPAIR SECTION I WAS PERFORMED ON FUSELAGE SKIN AT JACK POINT HOLE BETWEEN LONGERONS 30 AND 29R STA. 218. PER ER/A 576284-14 REV.ORIGINAL ASDR DALA2019031401673Skin · crackedAWR IN REF MON/916/096-MON, 88 L.P. 0582257: DURING INSPECTION WAS FOUND CRACK ON FUSELAGE SKIN STA Y=1437 BTW LONG 3R TO 4R NEAR TO PREVIOUS REPAIR. FUSELAGE SKIN WAS REPAIRED (PERMANET REPAIR) PER ER/A 576322-14 REV ORIGINAL AND ETI-88-19-024 REV 2. GENERAL SDR DALA2019031401672Skin · crackedCRACK ON FUSELAGE SKIN LONGERON 10 RH BETWEEN STA.207 AND 218. FUSELAGE SKIN WAS REPAIRED (PERMANET REPAIR) PER ER/A 576287-14 REV ORIGINAL AND ETI-88-19-022 REV. 2 GENERAL VISUAL INSPECTION ON REPAIR WILL BE MONITORING EVERY 8000 CYCLES UNDER L.P. 0981635 PERSDR DALA2019031301645Control Module · malfunctionedMID CARGO COMPARTMENT FIRE WARNING. LT ILLUM ON PANEL. EXTINGUISHED WITHIN 5 - 7 SECONDS WITH NO ACTIONS FROM CHECKLIST. GOOD SYSTEM AFTERWARD. COULD NOT DUPLICATE FAULT. REMOVED AND REPLACED CARGO DET-FIREX 3-BAY PANEL MODULE P/N ON/OFF 474007 S/N ON 0101 S/NSDR DALA2019031301644Battery Pack · dischargedVENTRAL STAIR CEILING EMERGENCY LIGHT NOT ILLUMINATING. REPLACED BATTERY PACK TO B5-28 CHARGER. (LP5724064)SDR DALA2019031201622Light · disconnectedEMERGENCY LIGHT OUT AT SEAT 33 E&D. FOUND LIGHT UNPLUGGED. CONNECTED SAME. CHECKS GOOD OK FOR SVC. (LP5765822)SDR DALA2019031201621Battery · dischargedEMERGENCY LIGHTS INOP IN OVERHEAD FROM SEAT 11-14. R/R BATTERIES FOR OVERHEAD LIGHTS 11-14. PER AMM 33-53. CHECKS NRML. OK FOR SVC. R/R BATTERIES FOR OVERHEAD LIGHTS 11-14. PER MD88 AMM 33-53. CHECKS NRML. OK FOR SVC. (LP5765823)SDR DALA2019031201623Wire · looseSEAT 4DC EMERGENCY LIGHT INOP. ATTACHED AND SECURED LOOSE WIRES AT SEAT 4DC PER STANDARD PRACTICE. OPS CK GOOD. (LP5529281)SDR DALA2019031101558Transducer · faultyLT OUTBD ANTI-SKID MESSAGE ON FINAL AFTER GEAR EXTENSION. RAN QRH, STAYED ON. FOUND LT OUTBD ANTI-SKID HAS FAULT. R/R NR 1 WHEEL SPEED TRANSDUCER REF AMM 32-43. PERFORMED WHEEL SPIN UP CHECK PER AMM 32-43 + SHOOK DOWN WIRING ON GEAR- ALL OPS OK- FAULTS CLEAREDSDR DALA2019031101557Battery · dischargedFWD GALLEY EMERG LIGHTS INOP. REPLACED BATTERIES. OPS CK GOOD. REF AMM 33-53. (LP5765059)SDR DALA2019031101556Battery · dischargedFOUND L & R FWD OVERWING EXIT LIGHTS INOP. FOUND BATTERY POWER SUPPLY UNIT FOR L & R OVERWING EXIT LIGHTS INOP. R+R BATTERY SUPPLY UNIT PER AMM 33-53. OPS CHECK GOOD. A/C OK FOR SVC. SN OFF 24552 SN ON 27370. (LP5826667)SDR DALA2019031101555Light · inoperative3C SEAT EMERGENCY LIGHT INOP. RELAMPED BULBS. LIGHTS CKS OK AT 3C. REF MM 33-53. (LP5832911)
Back to Mcdonnell Douglas MD-88