Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018103106351Unknown · hazeRIGHT AFTER GEAR RETRACTION BOTH AFT LABS SMOKE ALARMS STARTED BEEPING. NO SMOKES, LIGHT HAZE AND BURNING SMELL-LIGHT TO MEDIUM. WE COULD SMELL IN THE COCKPIT. AFTER 2 MINUTES THE ALARMS STOPPED & SMELL ,HAZE DISSIPATED. AT LANDING AFTER STARTING APE SMELL CAMSDR DALA2018103006338Battery Pack · dischargedCABIN EMERGENCY LIGHT AT ROW 13 TO 23 INOP AND FROM 31 TO AFT EMERG EXIT DOOR ALSO INOP. FOUND CEILING EMERGENCY LIGHT IN FWD AND MID CABIN INOP ALSO. R/R BATTERY AT SEATS 2C, 4DC 25DE, AND 35ED. ALL EMERGENCY LIGHT OPS CK NORMAL REF AMM 33-51 A/C OK FOR SVC. SDR DALA2018102906330Hydraulic Line · leakingFUME EVENT ON CLIMBOUT AND DESCENT AT 12K ALTITUDE BOTH TIMES WITH ENG A/I USAGE. AFT LAV, CAPT SIDE, FIRE ALARM ACTIVATED. WENT OUT AFTER 5 MINS. NO SMOKE OF FIEW REPORTED. FOUND APU AIR INLET CONTAMINATED WITH HYD FLUID. LEFT THRUST REVERSER CNTL VALVE UPPERSDR DALA2018102906329Battery · dischargedCEILING EMERGENCY LIGHTS OUT ROWS 17-19 AND 27-29. REPLACED BATTERIES FOR EMERG LIGHTS AT ROWS 17-19 AND 27-29 IAW AMM 33-53. ALL EMERGENCY LIGHTS NOW CK GOOD. (LP5002976)SDR DALA2018102906328Support Bracket · crackedFOUND CRACK IN RIGHT HYDRAULIC SERVICING HAND PUMP SUPPORT BRACKET. REPLACED CRACKED INTERCOSTAL PER DRAWING 5930584. (LP4756337)SDR DALA2018102906327Floor Panel · damagedCENTER AISLE FLOOR PANEL EXCESSIVE SPONGY AT ROW 24 WITH EDGE COVER FRACTURED. FOUND HARDWARE LOOSE RT SIDE FILLER PANEL. RESECURED. REPAIRED FILLER PANEL PER SRM 53-22. (LP5159970)SDR DALA2018102606304Slat · crackedRIGHT WING SLAT 0 "ZERO" HAS 2, 4 INCH GOUGES AND 1 INCH CRACK. REMOVED AND REPLACED RT WING SLAT ZERO PER WORK CARD 2700-4224-RH-0. (LP5351990)SDR DALA2018102606303Wire Harness · damagedSEAT 3CD EMERGENCY LIGHTS INOP. REPAIRED WIRE HARNESS AS REQUIRED, REF. SWPM 20-93. CHECKS GOOD. (LP4756331)SDR DALA2018102606302Cowling · dentedLEFT ENG, SMALL DEN ON COWLING. REMOVED AND REPLACED NR 1 ENG NOSE COWL PER AMM 71-11, ERA 572607-14 ORIG. (LP3762710)SDR DALA2018102606301Skin · crackedAWR- MTC REQUEST IN REFERENCE LOG 0249740 FUSELAGE - SKIN - STA 1380 - L13R-L14R - CRACK AND EXISTING REPAIR JOB NOR 44 PERFORM ER/A 551385-14 REV.A SECTION II. PERMANENT REPAIR WAS PERFORMED AT FUSELAGE SKIN BETWEEN STA 1380 AND L13R-L14R PER ETI-88-18-069 RESDR DALA2018102606300Skin · corrodedEVIDENCE OF CORROSION FOUND ON REPAIR EDGE AT AFT LAVATORY SERVICE PANEL- MARKED. SKIN/REPAIR BULGING OUT AT LOWER END OF CUTOUT. REPAIRED PER PRI 485410-14 REV A REV 0-3 MATCH ERA 485410-14 REV A. (LP0800060)SDR DALA2018102606299Channel · damagedAIRCRAFT DAMAGE: LT IB FLIGHT SPOILER HAT CHANNEL DAMAGED FROM SPOILER TORSION BAR REACTION BOLT. REPAIRED PER PRI 572530-14 REV O MATCHES ERA 572530-14 REV O. (LP0799992)SDR DALA2018102506275Connector · not seatedEMERGENCY LIGHT AT 20 ED NOT ILLUMINATING. RESEATED CONNECTOR.SDR DALA2018102506274Battery · dischargedAFT WINDOW EXIT SIGN LIGHT INOP BOTH SIDES. R&R AFT WINDOW EXIT SIGN BATTERY PER AMM 33-53. OPS CHECK GOOD.SDR DALA2018102506273Battery · dischargedROW 10-15 OVERHEAD EMER LIGHT OUT. R&R ROW 10-15 EMER LIGHT BATTERIES PER AMM 33-53. OPS CHECK GOOD.SDR DALA2018102506270Battery · dischargedEMERGENCY LIGHT IN AFT VENTRAL STARS OVERHEAD PANEL NOT ILLUMINATING. REPLACED BATTERIES IN EMERGENCY LIGHT POWER SUPPLY B5-28 IAW AMM 33-53.SDR DALA2018102506298Frame · crackedINITIAL INSPECTION: CRACK ON FRAME STA 1510 AT 4 AND 5 OCLOCK POSITION. FRAME STA 1510 AT 4 AND 5 OCLOCK POSITION WAS REPAIRED PER ETI-88-18-070 REV. 2 AND ER/A: 572579-14 REV. ORIGINAL. (LP0799059)SDR DALA2018102506272Battery · dischargedAFT OVERWING EMERGENCY DOOR EXIT LIGHTS INOP. T-S AND REPLACED CABIN OVERWING EMERGENCY DOOR LIGHTS BATTERY POWER SUPPLY PER MM 33-53. MPN - 803900-1, SN OFF - 25854, SN ON - 98354. OPS CHK GOOD. OK FOR SVC.SDR DALA2018102506271Battery Pack · dischargedFIRST CLASS EMERGENCY CEILING LIGHTS INOP. R&R BATTERY IN THE EMERGENCY BATTERY PACK B5-100 PER MM 33-53. OPS CHK - GOOD. OK FOR SVC.SDR DALA2018102506268Doubler · wornWEAR ON UPPER DOUBLER OF RT WING OUTBOARD FLAP INBOARD VANE. RT WING OUTBD FLAP INBD VANE WAS REPAIRED PER SRM 57-03D. PAR 11.SDR DALA2018102406267Fuse · blownALL EMERGENCY EXIT LIGHT IN F/C AND FWD ENTRY INOP. TROUBLESHOT FWD SECTION EMERGENCY LIGHTS FOUND B5-211 BATTERY PACK OVER ROW 3 CD FUSE BAD REPLACED PER WIRING DIAGRAM MAN 33-51-14. CKS GOOD PER AMM 33-53-01.SDR DALA2018102406266Skin · damagedDAMAGE TO FUSELAGE SKIN BETWEEN FS 370 AND 400 BELOW L-23L. PERMANENT REPAIR WAS PERFORMED AT FS 370- FS 400, BELOW L-23L PER ETI-88-18-071 REV ORIG AND ER-A NR 557644-14 REV A SECTION V.SDR DALA2018102406265Frame · crackedSTA 886 RT MAIN FRAME FOUND TO BE CRACKED THROUGH HFEC INSPECTION PERFORMED ON ROUTINE CARD 5310-01415-04D. REPLACED MAIN FRAME AT STA 886 RT PER 5310-01415-0302.SDR DALA2018102306241Tail Cone · unwanted deployWHILE PERFORMING MEET & GREET WALK AROUND AFT TAIL CONE DEPLOYED. TAIL CONE DROPPED DUE TO AFT ENTRY DOOR ACTIVATON PLACARD PUNCTURED, ARM OVER AFT DOOR DEPLOYED. SLIDE DID NOT DEPLOY DUE TO IT BEING PINED. INSTALLED TAIL CONE PER CARD 5350-9645 JOB #000-001: SDR DALA2018102306242Pin · missingCANT. FRAME FOR TAILCONE ALL ALIGNMENT PINS FOR TAILCONE HAVE WASHERS ON AFT SIDE OF FRAME. ALIGNMT PIN MISSING AT 3:00 POSITION. FOUND SHIM WASHER ARRANGEMENT ON ALIGNMENT PINS TO BE DEPENDENT ON TAILCONE CLEARANCE CHECK AT EACH ALIGNMENT PIN LOCATION PER AMMSDR DALA2018102306240Light · inoperativeOVHD EMERGENCY LIGHT INOP 18E 32E 36B. RELAMP PER AMM 33-50 OPS CHK GOOD. (LP4991033)SDR DALA2018102206193Controller · faultySHIP 0956 - WHILE ON APPROACH INTO ATL, THE COCKPIT NOTICED AN ELECTRICAL SMELL AND THIN SMOKE FROM THE LEFT WINDSHIELD HEAT TERMINAL. THE WINDSHIELD ANTI-ICE WAS TURNED OFF AND THE ODOR AND LIGHT SMOKE IMMEDIATELY DISSIPATED. CORRECTIVE ACTION: MAINTENANCE RESDR DALA2018102206187Battery Pack · failedDURING SERVICE CHECK, MAINTENANCE FOUND THE LEFT AND RIGHT AFT EMERGENCY EXIT SIGNS NOT ILLUMINATING. TROUBLE SHOOTING PER WDM 33-51-12 AND 33-51-14 ALLOWED DISCOVERY THAT THE EMERGENCY LIGHT BATTERY PACKS B5-105 AND B5-212 HAD FAILED. BOTH BATTERY PACKS WERE SDR DALA2018102206185Beam · crackedCRACK ON BEAM BELOW TORQUE TUBE STA 1485 AT AFT ACCESSORIES COMPARTMENT. NRC 00275: BEAM BELOW TORQUE TUBE STA 1485 AT AFT ACCESSORIES COMPARTMENT WAS REPLACED AND INSTALLED PER SRM 51-30-1, 51-30-2 AND 51-30-5. (LP #0794790)SDR DALA2018102206186Power Supply · inoperativeDURING SERVICE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHT PATHING IN THE BUSINESS CLASS AND ROWS 10-13 WERE INOPERATIVE. TROUBLE SHOOTING PER WDM 33-51-14 LEAD TO AN INOPERATIVE POWER SUPPLY CIN B5-211. THE POWER SUPPLY WAS REPALCED PER WDM 33-51-14. OPSDR DALA2018103106352Tray · stuckIN ARM REST TRY TABLE AT 10C STUCK IN DOWN POSITION PASSENGER MANAGED TO OPEN 1 TIME AND WHILE ATTEMPTING TO CLOSE/STORE HE CUT HIS FINGER. OPS CHECK NORMAL. TRAY TABLE STOWS AND COMES OUT NORMALLY AT LOC. 10C. SDR REPORTED DUE TO PASSENGER GETTING INJURED. (LSDR DALA2018101806183Fuse · blownEMERGENCY LIGHTS AT ROWS 24-30 ARE INOPERATIVE. MAINTENANCE FOUND A FUSE ON BATTERY PACK B5-212 TO BE BAD. THE BAD FUSE WAS REPLACED AND THE LIGHTS NOW OPERATE NORMALLY REF AMM 33-50.SDR DALA2018102206184Skin · crackedCRACKED FUSELAGE SKIN STA Y 1309 BTW LONGS 6R-7R (FUS). NRC 00016: AREA WAS REPAIRED PER SRM 53-04-2 FIG. 2 SHEET 15. PERFORM A GENERAL VISUAL INSPECTION OF THE REPAIR INITIAL AT 8,000 CYCLES AND REPETITIVE EVERY 8,000 CYCLES PER SRM 53-04-2 PARAGRAPH 3D. MAINSDR DALA2018101706133Battery · dischargedROW 16-20 ABC OVERHEAD E-LIGHTS INOP. R+R BATTERIES IN B5-102. OPS CK SAT. PER AMM 33-50. (LP4414850)SDR DALA2018101706132Threshold · crackedBEND AND CRACK ON THRESHOLD OF L1 ENTRACE. BEND AND CRACK ON THRESHOLD OF L1 WERE REPAIRED PER ER/A 552864-14MA REV. A AND SRM 51-10-2. (LP0787158)SDR DALA2018101706131Splice · crackedINITIAL INSPECTION: CRACKED SPLICE AND ANGLE STA XRS=164 AT RT WING FRONT SPAR. SPLICE AND ANGLE AT STA XRS=164 ON RT WING FRONT SPAR WERE REPLACED PER PER SRM 51-30-5, ER/A378293-14 REV. ORIG. AND DWG 9937517 REV J. (LP0785943)SDR DALA2018101506039Battery · dischargedMULTIPLE EMERGENCY LIGHTS INOP IN CEILING. R/R EMERGENCY BATTERIES IN OVERHEAD BIN AT SEATS 4DC, 17ED, AND 24ED PER AMM 33-53 OPS CK NORMAL OK FOR SVC. (LP5351209)SDR DALA2018101506038Battery Pack · dischargedFWD EMER. LIGHT PACK INOP. REMOVED AND REPLACED FWD EMER BATTERY PACK IAW AMM 33-53 OPS CHECKED GOOD. (LP5000750)SDR DALA2018101506037Doubler · wornINITIAL INSPECTION: WEAR ON LOWER CORNERS DOUBLERS AT FWD CARGO COMPARMENT DOOR. CORNERS DOUBLERS AT FWD CARGO COMPARMENT DOOR WERE REPLACED PER ER/A NR 486624-14MA REV. ORIGINAL. (LP0783466)SDR DALA2018101506041Sliding Window · obstructedSHIP 9000 - (ATB) AIR TURN BACK TO ICT DUE TO PRESSURIZATION ISSUES AND REPORT OF FO'S WINDOW LEAKING AIR. O2 MASKS DID NOT DEPLOY. CORRECTIVE ACTION: MAINTENANCE FOUND NO FAULTS ON CPC'S 1 OR 2. DEBRIS WAS FOUND AND REMOVED FROM FO'S SLIDING WINDOW. BOTH CPC'SDR DALA2018101506040Smoke Detector · defectiveAFT LAV SMOKE DETECTER RT GOING OFF. AFT RT LAV SMOKE DETECTOR NOT TESTING REPLACED SAME OPS NORMAL. (LP4822100)SDR DALA2018101506035Skin · crackedAFT CARGO DOOR SKIN, CREASED AND VISUAL INDICATION OF CRACK AT LOWER SURFACE, JUST AFT OF CENTER. REPLACED AFT CARGO DOOR REF AMM 52-31-00. (LP0779958)SDR DALA2018101005979Battery Pack · dischargedEMERGENCY LIGHTS FOR OVERWING W/N ILLUMINATE FOR ROW 25. REMOVED BATTERY PACK AND REPLACED BATTERIES, OP'S CK'S GOOD PER AMM 33-53.SDR DALA2018101005978Wire Harness · disconnectedSEAT 33ED EMERGENCY PATH LIGHT INOP. RECONNECTED UNDER SEAT HARNESS. CKS GOOD PER AMM 33-50.SDR DALA2018101005980Light · missingLOWER ANTI-COLLISION LIGHT MISSING. C/W ERA 572237-14 SECTION 1 TIME LIMITED REPAIR. SDR REPORTED DUE TO FACT THAT PART MAY HAVE DEPARTED FROM THE AIRCRAFT DURING FLIGHT.SDR DALA2018101005976Rudder · damagedCOMPOSITES SHOWING ON MULTIPLE AREAS ON RUDDER. REMOVED RUDDER ON WORKCARD 2720-4187. INSTALLED NEW RUDDER ON WORKCARD 2720-4421. RIGGED RUDDER ON WORKCARD 2720-7454.SDR DALA2018100905939Warning System · false activationT/O CONFIG WARNING ABOVE 80KTS-SLATS-AURAL WARNING WITH SLAT DISAGREE. INITIATED RTO AROUND 90-100KTS. MAX BRAKE TEMP 250. C/W NO GO ODI PREVENTION SECTION ATA 2700 TAKE-OFF WARNING SYSTEM DISCREPANCIES. T/O WARNING CKS GOOD. ALSO VISUALLY INSPECTED SLAT POSITSDR DALA2018100805914Connector · out of adjustEMERGENCY LIGHT SEAT 15ED INOP. ADJUSTED WIRE CONNECTION. OK FOR SVC. (LP5351383)SDR DALA2018100805915Schrader Valve · leakingA/C RETURNED BACK TO SAV FOR NOSE GEAR UNABLE TO RETRACT. PILOTS FOLLOWED QRH PROCEDURES. FOUND SHRADER VALVE LEAKING, REPLACED SAME PER M/M 32-20. SERVICED NOSE STRUT PER W/C 3221-644 OK FOR SERVICE. REPORTED DUE TO DECLARED EMERGENCY. (LP4188484)SDR DALA2018100805912Fitting · crackedLATE FINDING (IN REF 5700-2246): RT CRACK ON OUTBD FITTING TO ATTACH SLAT TRACK NR 10 AT SLAT PANEL NR 3 RT WING. SLAT PANEL ASSY 3 RT PART NUMBER OFF : 5922533-504 SERIAL NUMBER OFF: DL27 WAS REMOVED PER WORK CARD 2700-4224-RH-03 AND SERVICEABLE SLAT PANEL AS
Back to Mcdonnell Douglas MD-88