What was found
SHIP 0956 - WHILE ON APPROACH INTO ATL, THE COCKPIT NOTICED AN ELECTRICAL SMELL AND THIN SMOKE FROM THE LEFT WINDSHIELD HEAT TERMINAL. THE WINDSHIELD ANTI-ICE WAS TURNED OFF AND THE ODOR AND LIGHT SMOKE IMMEDIATELY DISSIPATED. CORRECTIVE ACTION: MAINTENANCE REPLACED THE CAPTAINS WINDSHIELD, HEAT CONTROLLER, AND TERMINAL HARDWARE PER THE MAINTENANCE MANUAL. (LP 5352102)