Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014120606462Frame · crackedAFT ACCESSORY BAY CANTED FRAME BS 1485, LT SIDE LOWER WEB CRACKED. CUT OUT CRACKED SECTION OF WEB,. FABRICATED AND INSTALLED DOUBLER AND TRIPLER IAW SRM 53-03, FIG 48.SDR DALA2014120606461Door Frame · corrodedAFT CARGO DOOR FRAME, FWD FACE AND LOWER FLANGE HAS CORROSION BETWEEN BS 1174-1211. REMOVED CORROSION IAW SRM 51-10-3 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-05, FIG 123, SHT 2. LOCATED, DRILLED AND INSTALLED DOUBLER AND SPACER REPAIR PARTS IAW SRM 53-05, FISDR DALA2014120806450Structure · crackedCORROSION AND CRACK AROUND OF SETTLEMENT AREA OF LT APU DOOR. CORROSION WAS REMOVED IAW SRM 51-10-3, PAR 26. FASTENERS WERE REMOVED IAW SRM 51-30-2, NEW REPAIR DOUBLERS WERE FABRICATED IAW SRM 52-05D, FIG 9 NEW REPAIR DOUBLERS WERE TREATED AND PAINTED IAW SDR DALA2014120606448Frame · crackedCANTED FRAME BS 1485 CRACKED AT LT AFT SIDE OTBD OF LIGHT ASSY. DAMAGE WAS REMOVED IAW SRM 53-030, FIG 48. REPAIR FABRICATED IAW SRM 53-030, FIG 8 AND INSTALLED IAW SRM 53-030, FIG 48.SDR DALA2016111008680Frame · corrodedCORROSION ON FRAME BS 1287, BETWEEN LONGERONS 29 TO 30L. THE FRAME WAS REPAIRED IAW SRM 53-03 D FIG 2A,SDR DALA2014120406440Release Cable · misroutedDURING CHECK, MAINTENANCE FOUND THE FORCE REQUIRED TO RELEASE THE TAILCONE EXCEEDED THE LIMITS. MAINTENANCE FOUND THE RELEASE CABLE ROUTED IMPROPERLY AND ROUTED THE CABLE TO THE PROPER POSITION AND PERFORMED A TAILCONE FUNCTIONAL TEST.SDR DALA2014120406421Line · leakingDURING INITIAL CLIMBOUT, CREW REPORTED A HOT HYDRAULIC ODOR BEING EMITTED FROM THE AIR CONDITIONING SYSTEM. BOTH THE FORWARD AND THE REAR LAVATORY SMOKE DETECTORS SOUNDED. ODOR DISSIPATED AND ALARMS SILENCED QUICKLY BUT THEN IT ALL REPEATED DURING APPROACH FSDR DALA2014120506419Skin · damagedCRACKED REPAIR DOUBLER AND ELONGATED HOLES ON INTERNAL STRUCTURE AT LT WING INBD BUTE DOOR AFT EDGE. REPAIR WAS REMOVED, AND A NEW DOUBLER WAS FABRICATED, TREATED, PAINTED, AND INSTALLED IAW SRM 51-30-2 AND 51-30-5, 57-01, FIG 3 AND 51-10-3, PAR 14 AND 21. SDR DALA2014120906445Unknown · smokeDURING A HOLDING PATTERN, THE F/A REQUESTED MORE HEAT FOR A COLD CABIN. AFTER THE COCKPIT CREW ADJUSTED THE TEMPERATURE UP, THE F/A REPORTED SMOKE AND HAZE FILLING CABIN. COCKPIT CREW DONNED O2 MASKS AND ADJUSTED THE TEMP BACK DOWN AND HAZE DISSIPATED. MAINSDR DALA2014120506418Structure · corrodedCORROSION IN AFT CARGO BILGE AREA, BS 1231 L29R-28R, FWD AND AFT OF FORMER. REMOVED THE CORROSION AND EVALUATED MAT AT STA 1231, FROM L-29R-28R ON FORMER. ORIG MATERIAL .080, REMAINING MATERIAL .050, MAT LOSS .030 AND FOUND TO BE OUT OF LIMIT IAW SRM 53-01, SDR DALA2014120406416Unknown · crackedLT AFT FUSELAGE BS 1380 IS CRACKED AT FASTENER APPROXIMATELY 12" ABOVE PYLON. ACCOMPLISHED WORK STEPS OF PRI 531053-14, REV 0 AND COMPLIED WITH ER/A 531053-14, REV ENTERED AND DEFERED FOR SDR REPORTING.SDR DALA2014120406415Pan · crackedOVERWING EMERGENCY DOOR RT AFT PAN STRUCTURE CRACKED AT UPPER FWD BRACKET. ACCOMPLISHED REPAIR IAW INSTRUCTION OF PRI 531058-14, REV 0. COMPLIED WITH ER/A 531058-14, REV ORIGINAL SCEPTRE LOG PAGE ENTERED AND DEFERED FOR SDR REPORTING.SDR DALA2016111008677Floorbeam · corrodedFLOORBEAM CORRODED BS 1307, X 22. REPAIRED THE FLOORBEAM.SDR DALA2014120306439Pin · wornDURING CHECK, MAINTENANCE FOUND THE TAILCONE LOWER LEFT RELEASE LATCH PIN WORN. MAINTENANCE REPLACED THE LATCH PIN.SDR DALA2014120506420Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT SEAT 3D WERE INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND PERFORMED A SATISFACTORY FUNCTIONAL CHECK OF IT.SDR DALA2014120306414Skin · damagedDAMAGE ON FUSELAGE SKIN BELOW RUB STRIPS AREA FROM BS 1117 - 1079 BETWEEN LONGERONS 25-30. . CORROSION WAS REMOVED IAW SRM 51-10-3, PAR 26. AREAS WITHIN LIMITS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 14-21.SDR DALA2014120306413Pan · crackedCRACK BEYOND PREVIOUS STOP DRILL ON FWD UPPER CORNER AT DOOR PAN OF FWD PASSENGER DOOR. DOOR PAN WAS REPLACED IAW SRM 52-05D, 51-30-1, 51-30-2, 51-30-4.SDR DALA2014120306411Intercostal · corrodedINTERCOSTAL CORRODED BETWEEN BS 1271-1287 BL 0. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-10-3, PAR 21,14, 26, 38; 51-30-2, 51-30-5, ER/A 511165-14, REV B, AMM 20-30-01-201, DWG 9936580.SDR DALA2014120206380Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT ROWS 30-36 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA2016111008682Skin · corrodedGENERAL SURFACE CORROSION ON FWD CABIN PRESSURE SAFETY VALVE FUSELAGE SKIN. PRESSURE VALVE COLLAR WAS REPLACED IAW DWG 591657555-5 REV.E. AND SRM 51-30-1 & 51-30-2 FWD CABIN PRESSURE SAFETY VALVE WAS REMOVED, INSTALLED, AND TESTED IAW AMM 21-32-07. (UT) WAS ASDR DALA2014121206517Frame · crackedCANT FRAME BS 1485 CRACKED AT LT AFT SIDE OF OTBD LIGHT ASSY. DAMAGE WAS REMOVED IAW SRM 53-03, FIG 48. REPAIR FABRICATED IAW SRM 53-03, PAR 48. REPAIR DRILLED AND TRIMED IAW SRM 53-03, FIG 48. REPAIR TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14. RESDR DALA2014120406417Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS IN THE VENTRAL STAIRWAY WERE INOPERATIVE. MAINTENANCE FOUND BROKEN TERMINALS AT THE AFT STAIRWAY EMERGENCY LIGHT L2646 AND REPAIRED THEM. THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014120206364Longeron · damagedFOUND A DENTED AND BENT LONGERON AT BS 305, LONGERON 30L. REPAIRED IAW SRM 51-10-2. HFEC AREA IAW NDTSPM PT6 06-10-01, NO CRACKS NOTED, FABRICATED AND INSTALLED A REPAIR ANGLE IAW SRM 53-02, FIG 19.SDR DALA2014120206363Longeron · damagedFOUND A DENTED AND BENT LONGERON AT FORWARD CARGO BAY BS 305, LONGERON L29R. REPAIRED THE LONGERON FLANGE IAW SRM 51-10-2. HFEC AREA IAW NDT SPM, PT 6 06-10-01. NO CRACKS NOTED, FABRICATED AND INSTALLED A REPAIR ANGLE IAW SRM 53-02, FIG 19.SDR DALA2014120106351Attach Bracket · wornDURING CHECK, MAINTENANCE FOUND THE TAILCONE SPRING ATTACH BRACKET WORN. MAINTENANCE REPLACED THE WORN BRACKET.SDR DALA2014120106350Cable · frayedDURING CHECK, MAINTENANCE FOUND THE TAILCONE KEVLAR CABLE TO BE FRAYED. MAINTENANCE REPLACED THE KEVLAR CABLE.SDR DALA2014120106337Frame · corrodedCORROSION ON FRAME, BS 1287 BETWEEN LONGERONS 29 - 30L. FRAME REPAIRED IAW SRM 53-03 D, FIG 2A.SDR DALA2014120106336Cargo Track · corrodedCORROSION ON RT CARGO TRACK BS 1212-1322. THE CARGO TRACK WAS REMOVED, AND CORROSION WAS REMOVED. A NEW CARGO TRACK WAS DRILLED, TREATED, PAINTED, AND INSTALLED IAW SRM 51-30-1, 51-10-3, PAR 26,14,21 AND 38, SRM 53-05, FIG 4C, SRM 51-10-4, 51-30-1 AND NDT SDR DALA2014120106335Frame · corrodedCORROSION ON FRAME BS 1380 BETWEEN LONGERONS 26 - 30R. FRAME REPLACED IAW SRM 51-30-2 AND 51-30-5 AND DWG 9912246-REV DE.SDR DALA2014120106334Intercostal · corrodedCORROSION ON INTERCOSTAL BETWEEN BS 1145-1155 AND L28-29R. THE INTERCOSTAL WAS R&R IAW SRM 51-30-2, 51-30- 5, 51-10-3 PAR 14, 21, 26, 38 ER/A 511165-14 MA, REV B, 51-10-4.SDR DALA2014120306412Frame · crackedFRAME BS 1287 LONGERON 23L CRACKED AND CORRODED. A CUT OUT DAMAGED SECTION OF FRAME. FABRICATED REPAIR AND INSTALLED IAW SRM 53-03, FIG, 2 A.SDR DALA2014120106352Receptacle · wornDURING CHECK, MAINTENANCE FOUND THE TAILCONE UPPER LT LATCH PIN RECEPTACLE HAS A WORN EAR. MAINTENANCE REPLACED THE RECEPTACLE.SDR DALA2014120206381Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT SEATS 12DE AND 20DE WERE INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AT 12DE AND REPLACED THE PIGTAIL ASSEMBLY AT 20DE. THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014112906353Battery Pack · inoperativeMAINTENCE FOUND THE CEILING EMERGENCY LIGHTS AT ROW 16 WERE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY PACK AND THE LIGHTS TESTED GOOD.SDR DALA2014112906332Access Panel · corrodedCORROSION ON RT FUEL TANK ACCESS PANEL COUNTERSINK AND SETTLEMENT AREAS. THE CORROSION WAS REMOVED, AND AREAS FOUND WITHIN LIMITS WERE TREATED AND PAINTED IAW SRM 51-22-2A. AREAS OUT OF LIMITS WERE REPLACED IAW SRM 51-22-2A, CONDITION II FIG 8.SDR DALA2014120206438Bushing · wornDURING CHECK, MAINTENANCE FOUND THE TAILCONE TEE PIN BUSHING WORN. MAINTENANCE REPLACED THE BUSHING.SDR DALA2014112906333Floorbeam · corrodedCORROSION ON LT FLOORBEAM BS 1322, X 18, X 26. DAMAGE AREA WAS REPAIRED IAW SRM 53-05, FIG 79A, SH 1.SDR DALA2014112806331Cargo Track · corrodedCORROSION FOUND ON CARGO TRACK BS 1222-1322. THE CARGO TRACK WAS REPLACED IAW SRM 51-10-3, PAR 14, 21, 38 AND 51-30-1.SDR DALA2014112806330Cargo Track · corrodedCORROSION FOUND ON OF THE CARGO TRACK BETWEEN BS 1003-1222. THE CARGO TRACK WAS REMOVED AND REPLACED IAW SRM 51-30-1, 51-30-2, 51-10-3, 51-10-4, SRM 51-10-3, AND INSTALLED IAW SRM 51-30-1 AND 51-30-2.SDR DALA2014112806329Cargo Track · corrodedCORROSION ON CARGO TRACK BETWEEN BS 1003-1155. THE CARGO TRACK WAS REMOVED IAW SRM 51-30-1, 51-30-2, AND A NEW CARGO TRACK WAS DRILLED IAW SRM 51-10-4, SRM 51-10-3, PAR 14, 21, AND INSTALLED IAW SRM 51- 30-2, 51-30-1.SDR DALA2014112806328Cusp Web · corrodedCORROSION FOUND ON RT CUSP WEB AND REPAIRS DOUBLES BS 465 - 484. THE CORROSION WAS REMOVED IAW SRM 51-10-3, PAR 26 AND FOUND OUT OF LIMITS. DAMAGE WAS REMOVED, REPAIR FABRICATED, TREATED AND PAINTED, AND INSTALLED IAW SRM 51-10-3, 53-05 FIG 131 AG, 51-30-2 SDR DALA2014112806327Spacer · corrodedCORROSION ON LOWER CARGO DOOR FRAME BS 636-693 LONGERON 28R. SPACER WAS REMOVED IAW SRM 51-30-2, 51-30- 4, A NEW SPACER WAS FABRICATED IAW SRM 53-05, FIG 123, OPT 1, TREATED AND PAINTED IAW SRM 51-10-3, PAR 14, 21, AND INSTALLED IAW SRM 53-05, FIG 123, 51-20SDR DALA2014120206379Structure · corrodedFWD CARGO BAY BS 408-427, STR 29-30L HAS AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-10-3 AND FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1, PAGE 3. CUT OUT DAMAGE AREA, FABRICATED AND INSTALLED REPAIR IAW SRM 53-02, FIG 18.SDR DALA2014112706362Longeron Splice · corrodedAFT ACCESSORY BAY LONGERON SPLICE 17R AT BS 1420 WAS CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01 AND 51-10-03, PARA 26. REMOVED AND INSTALLED A NEW LONGEORN SPLICE IAW SRM 51-30-05 AND 51-10-4, PARA 2.SDR WX0A2014120172281Transducer · inoperativeREJECTED TAKEOFF AT 120 KTS FOR A STALL WARNING. R & R LT AOA TRANSDUCER IAW MM 34-19-01. PERFORMED STALL WARNING TEST IAW 34-19-00 & RTS IAW 22-01-05. OPERATIONS CHECKED GOOD. PERFORMED HIGH ENERGY STOP INSPECTION IAW MM 05-57-00. NO FAULTS FOUND.SDR DALA2014112706326Frame · corrodedCORROSION ON FRAME BS 1307 BETWEEN LONGERONS 29L & 29R. SECTION OF FRAME WAS REMOVED, A NEW SECTION OF FRAME AND REPAIR WERE FABRICATED, DRILLED, TREATED PAINTED AND INSTALLED IAW SRM 53-03D, FIG 2-A.SDR DALA2014112606269Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGNS AT BOTH OF THE OVERWING HATCHES WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA2014112606268Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT ROWS 11 AND 17 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE HARNESS AT 11 AND RE-PINNED THE CONNECTOR AT 17. THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014112706325Access Panel · corrodedCORROSION FOUND ON RT FUEL TANK ACCESS PANEL. CORROSION WAS REMOVED IAW SRM 51-22-2A, REPLACED IAW SRM 51-22-2A COND II.SDR DALA2014112706323Skin · corrodedCORROSION ON FUSELAGE SKIN BS 1096 - 1100 BETWEEN LONGERONS 25 - 30L. REPAIRED IAW SRM 53-04, FIG 57.
Back to Mcdonnell Douglas MD-88