Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014101705685Door Sill · corrodedMID CARGO DOOR OPENING LOWER SILL HAS CORROSION. REPAIRED IAW SRM 53-05, FIG 123 AND DWG SR09520008.SDR DALA2014101705607Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTS AT ROWS 21-30 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPS CHECKED GOOD.SDR DALA2014101505704Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THE OVERHEAD EMERGENCY LIGHTS AT ROWS 17-20 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE OPS CHECKED GOOD.SDR DALA2014102105686Unknown · odorDURING CLIMB, THE AFT RT LAVATORY SMOKE DETECTOR WENT OFF WITH A MILD ODOR AND HAZE. ALSO, HAD ODOR IN COCKPIT AT THE SAME TIME. MAINTENANCE PERFORMED PNEUMATIC SYSTEM DUCT BURNOUT.SDR DALA2014101605684Skin · crackedACFT SKIN HAS FOUR CRACKS, ONE IS FOUR INCHES LONG THRU ADJACENT FASTENER HOLES IN LONGERON 14R BS 1379-1383, ANOTHER IS .2500 INCHES LONG AT BS 1380 AT A FASTENER HOLE .7500" ABOVE L14RT, ANOTHER IS .6250 INCHES LONG AT BS 1380 AT A FASTENER HOLE 1.5 ABOVE LSDR DALA2015012607854Skin · damagedSCRATCHES ON LOWER CORNER WINDOW BELT BS 319 AND BETWEEN BS 374 - 378 AT LT FWD FUSELAGE. SCRATCHES WERE BLENDED OUT MEASURED AND TREATED IAW SRM 53-05, FIG 111 AND ER/A 529358-14, REV ORIGINAL. A PERMANENT REPAIR WAS ACCOMPLISHED.SDR DALA2014101505682Cargo Track · damagedENLOGATED HOLES ON LT CARGO TRACK BS 712 - 786. CARGO TRACK REPLACED IAW SRM 53-05, FIG 4G AND 51-30-2, 51-10-4, 51-10-3 PAR. 14 AND 21.SDR DALA2014101505681Access Panel · corrodedCORROSION ON COUNTERSINK HOLES AT ACCESS PANEL. CORROSION WAS REMOVED IAW SRM 51-22-2A, AND FOUND OUT OF LIMITS. THE ACCESS PANEL WAS REPLACED IAW SRM 51-22-2A CONDITION II.SDR DALA2014101505680Support · corrodedVENT SUPPORT PLATE HAS CORROSION AT BS 1287-1307. REPAIRED IAW PRI 529794-14, REV 0 AND ERA 529794-14, REV ORIG.SDR DALA2014101505679Angle · corrodedCORROSION ON CUSP WEB ANGLE BETWEEN X -60 TO X -54, BS 180 - 200. REMOVE CORROSION ON CUSP WEB ANGLE AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. ANGLE WAS REPAIRED IAW SRM 53-05, FIG 55 AND ETI-88-14-215.SDR DALA2014101505678Skin · damagedLIGHTNING STRIKE ON LOWER WINDOW BELT BETWEEN BS 522 - 541. DAMAGE BLENDED OUT IAW SRM 53-05, FIG 111, ER/A 529358-14, REV ORIGINAL AND ER/A 529360-14, REV ORIGINAL.SDR DALA2014101505677Skin · scratchedSCRATCHES ON RT WINDOW BELT BETWEEN BS 427-965. SCRATCHES BLENDED OUT IAW SRM 53-05, FIG 111, ER/A 529358-14 REVISION ORIGINAL.SDR DALA2014101505683Cusp Web · corrodedCORROSION ON CUSP WEB BELOW SEAT TRACK X- 54 BS 218 . CUSP WEB REPAIRED IAW SRM 53-05, FIG 131A-17, AND SRM 51-30-2.SDR DALA2014101405532Pan · crackedCRACKED PAN ON FWD UPPER CORNER OF LT FWD OVERWING EMERGENCY EXIT DOORS. CRACK ON PAN WAS STOPPED REPAIR DOUBLER WAS FABRICATED, PAINTED AND INSTALLED IAW SRM 52-05 A, FIG 51.SDR DALA2014101405544Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTING AT SEAT 11, 12, AND 14 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA2014101305530Beam · corrodedCORROSION ON MID CARGO DOOR FRAME UPPER BEAMBS 655 - 693. REMOVED AND REPLACED THE BEAM IAW 53-14-2, FIG 2, 51-30-2, SRM 51-30-5 AND SRM 53-14-2, FIG 2.SDR WX0A2014101572195Container · defectiveCOCKPIT O2 MASK BAG IS DEFECTIVE, CAPTAIN`S & FIRST OFFICER`S. R & R O2 MASK BAGS IAW 35-10-03 AMM.SDR DALA2014101405543Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS IN ROWS 16-20 IN THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPS CHECKED GOOD.SDR DALA2014101405542Wire · pulledDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHT AT SEAT 3D IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND A WIRE PULLED OUT OF THE CONNECTOR. THE WIRE WAS REINSTALLED AND THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2016111008614Door Frame · corrodedCORROSION ON AFT CARGO DOOR FRAME NUT STRIP BS 1171-1174. REMOVED, FABRICATED NEW STRIP, TREATED, PAINTED AND INSTALLED.SDR DALA2014101205529Cusp Web · corrodedCORROSION ON RT CUSP WEB BS 200, X 44-54. CUSP WEB WAS REMOVED AND REPLACED IAW 51-30-2, 51-30-5, SRM 51-10-3, PARA 26 AND 53-01, FIG 1, SRM 53-14-1 AND 51-10-4.SDR DALA2014101305508Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTS AT ROWS 23, 24, & 25 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPS CHECKED GOOD.SDR DALA2014101305507Wire · pulledDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT SEAT 23D IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND A WIRE PULLED OUT OF THE CONNECTOR. THE WIRE WAS REINSTALLED AND THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014101305506Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS IN THE TAIL WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA2016111008613Cargo Track · corrodedCORROSION ON LT CARGO TRACK BS 693 - 788 . CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED THE CARGO TRACK.SDR DALA2016111008612Seat Track · corrodedCORROSION ON RT SEAT TRACK BS 200, X -43 TO X -45. THE SEAT TRACK WAS REMOVED AND REPLACED.SDR DALA2014101005527Attach Fitting · missingMAINTENANCE FOUND A MISSING CLIP ON THE INTERNAL RELEASE HANDLE OF THE TAILCONE. MAINTENANCE INSTALLED A CLIP.SDR DALA2014101005528Door Frame · corrodedCORROSION ON AFT CARGO DOOR FRAME BEAM . REPAIRED IAW SRM 51-30-5, 53-05, FIG 123, 51-10-3, PAR 21 AND 14.SDR DALA2014101005526Intercostal · crackedCRACK ON INTERCOSTAL AT RT MLG INBD DOOR BETWEEN BS 953 - 958 . INTERCOSTAL WAS REMOVED AND REPLACED IAW SRM 51-30-2 AND 51-30-5.SDR DALA2014101005524Pan · crackedCRACKED PAN ON AFT UPPER INTERCOSTAL OF RT AFT OVERWING EMERGENCY EXIT DOOR. CRACK ON PAN WAS STOPPED AND REPAIR DOUBLER WAS FABRICATED PAINTED AND INSTALLED IAW SRM 52-05D, FIG 51.SDR DALA2014101505573Cargo Track · corrodedCORROSION ON LT CARGO TRACK, BS 1222-1289. REMOVED AND REPLACED THE CARGO TRACK IAW 51-10-3, PAR 14, 21, 26, 53-05, FIG 4C, 51-30-1, 51-30-2, 51-30-5, 51-10-4.SDR DALA2014101505572Cargo Track · corrodedCORROSION ON RT CARGO TRACK, BS 1212-1287. CARGO TRACK WAS REMOVED, AND CORROSION WAS REMOVED AND FOUND OUT OF LIMITS. THE CARGO TRACK WAS REPLACED IAW SRM 51-30-1 AND 51-30-2, SRM 51-10-3, PAR 26, 21 AND 14, SRM 53-05, FIG 4C, SRM 51-10-4.SDR DALA2014100905523Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THE ROW 10 IN SEAT EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE AND THE OPS CHECK WAS GOOD.SDR DALA2014101005525Frame · crackedCRACKED FRAME BS 984. REMOVED AND REPLACED IAW 51-30-1 AND 51-30-2,51-30-5SDR DALA2014100905520Skin · corrodedDAMAGED METALLIZED ON BOTH FACES OF RUDDER METALLIZED ON BOTH FACES OF RUDDER WERE REPAIRED IAW SRM 51-70-1A, PAR 23.SDR DALA2014101505571Cusp Web · crackedCRACKED RT CUSP WEB BS 845 BETWEEN X -52 TO X -60 . DAMAGE WAS REMOVED, REPAIR PARTS WERE FABRICATED TREATED AND PAINTED IAW SRM 53-05, FIG 131A-21, 51-10-3, PAGE 14, 21 AND REPAIR PARTS WERE INSTALLED IAW SRM 53-05, FIG 131A-21.SDR DALA2014100905487Sleeve · wornMAINTENANCE DISCOVERED THAT THE KEVLAR SLEEVE OVER THE RELEASE CABLE FOR THE TAILCONE WAS WORN OUT OF ALLOWABLE LIMITS. THE CABLE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR DALA2014101405534Cam · wornMAINTENANCE FOUND A WORN TAILCONE CAM BASE. MAINTENANCE REPLACED THE TAILCONE CAM BASE AND THE RII STEPS WERE COMPLETED.SDR DALA2014100905521Cusp Web · corrodedCORROSION ON REPAIR DOUBLER BS 560-579 AND X 54 - 60. CUSP WEB REMOVED AND REPLACED IAW SRM 51-10-3,51-30-2 , 51-30-5 AND 51-30-1.SDR DALA2014100805519Skin · corrodedCORROSION ON RT HORIZONTAL STABILIZER SKIN. REPAIRED IAW SRM 55-03D, PAR 30, FIG 32 AND EA/A 529348-14 REV ORIGINAL AND ETI-88-14-190, REV. 2.SDR DALA2014100805518Skin · corrodedCORROSION ON LT HORIZONTAL STABILIZER. REPAIRED IAW SRM 55-03, PAR 30 AND ER/A 529348-14, REV ORIGINAL FIG 32 AND ETI-88-14-192, REV 2.SDR DALA2014100805517Pan · crackedCRACKED PAN UNDER MID CARGO DOOR FWD ANGLE BETWEEN BEAMS 1 AND 2 IAW ORNRC 79 ACFT ZONE 100.SDR DALA2014101505574Angle · corrodedCORROSION ON AFT CARGO BAY AFT BULKHEAD LOWER ANGLE BS 1322 BETWEEN LONGERONS 24L-24R. CORROSION REMOVED, AND FOUND OUT OF LIMITS. THE ANGLE WAS REPAIRED IAW SRM 51-30-2, SRM 51-10-3, PAR 26, 21 AND 14, ER/A 511165-14 MA, REV B.SDR DALA2014100905486Release Cable · out of rigMAINTENANCE DISCOVERED THAT THE TAILCONE RELEASE CABLE WAS OUT OF ALLOWABLE RIG LIMITS AS IT DID NOT CLEAR THE CONDUIT BY THE SPECIFIED .2". THE CABLE CLAMPS WERE ADJUSTED AND THE SYS WAS RIGGED BACK INTO SPECIFICATIONS. THE RII STEPS WERE COMPLETED.SDR DALA2014100905485Cam · wornMAINTENANCE DISCOVERED THAT THE TAILCONE RELEASE MECHANISM CAM BASE WAS WORN OUT OF ALLOWABLE LIMITS. THE CAM BASE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS.SDR DALA2014100905484Conduit · wornMAINTENANCE DISCOVERED THAT THE LT AND RT SIDE CONDUIT FOR THE RELEASE CABLE OF THE TAILCONE WAS WORN OUT OF ALLOWABLE LIMITS. THE CONDUIT TUBE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR DALA2014100805482Service Panel · corrodedAFT LAVATORY SERVICE PANEL HAS BULGING CORROSION AT THE LOWER FWD CORNER. CUTOUT SKIN AND INTERNAL DOUBLER TO REMOVE AREAS OF CORROSION. REPAIRED IAW PRI 529587-14, REV 0, 1, AND 2. ALL STEPS ACCOMPLISHED. COMPLIED WITH ER/A 529587-14, REV ORIG.SDR DALA2014100805481Spar · crackedVERTICAL STABILIZER LT SIDE FRONT SPAR CRACKED BELOW ZFS 52.267. REPAIRED IAW ER/A 529591-14AD, REVISION ORIGINAL.SDR DALA2014100805480Angle · damagedDURING C-CHECK, ELONGATED HOLES WERE FOUND COMMON TO THE LT ANGLE OF THE VERTICAL STABILIZER FRONT SPAR. FOUR OF THE HOLES ARE THE FIRST, FOURTH, FIFTH, AND SIXTH ABOVE ZFS=52. ONE OF THE HOLES IS THE FOURTH HOLE BELOW ZFS=52. ER/A 529591-14AD SECT I WASDR DALA2014100805479Frame · crackedCANTED FRAME WEB AT BS 1485, HAS A .3750 INCH LONG CRACK AT RIVET, NEAR 8:00 O`CLOCK POSTION, WHERE TAIL INTERIOR TAIL CONE RELEASE HANDLE SUPPORT ANGLE ATTACHES. REPAIRED IAW SRM 51-70-05.
Back to Mcdonnell Douglas MD-88