Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014102905902Pan · crackedCRACKED LT AFT OVERWING EMERGENCY EXIT DOOR PAN AT STOP NR 1. PAN WAS REPAIRED IAW SRM 52-05D, FIG 51.SDR DALA2014102905901Pan · crackedCRACKED LT FWD OVERWING EMERGENCY EXIT DOOR PAN AT STOP NR 12. PAN WAS REPAIRED IAW SRM 52-05D, FIG-51SDR DALA2014102905900Pan · crackedCRACKED RT AFT OVERWING EMERGENCY EXIT DOOR PAN AT STOP NR 12, PAN WAS REPAIRED IAW SRM 52-05D.SDR DALA2014102805815Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHT AT SEAT 24D WAS DAMAGED. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND PERFORMED A SATISFACTORY FUNCTIONAL CHECK.SDR DALA2014102905880Wire · damagedMAINTENANCE FOUND THE EMERGENCY LIGHT AT SEAT 21D WAS INOPERATIVE. MAINTENANCE REPLACED THE PIG TAIL AT SEAT 21D AND THE OPS CHECK WAS GOOD.SDR DALA2014102905878Charger · inoperativeDURING CHECK, MAINTENANCE FOUND THE EMERGENCY LIGHTS INOPERATIVE AT ROWS 1-4. MAINTENANCE REMOVED AND REPLACED THE BATTERY CHARGER AND BATTERIES AT ROW 4 AND THE OPERATIONAL CHECK WAS GOOD. (LP 6171988)SDR DALA2014103005926Longeron · damagedWEAR ON AFT ACCESSORY COMPARTMENT LONGERON 8R PREVIOUS REPAIR SECTION BETWEEN Y= 1401-1418. LONGERON WAS REMOVED FROM STA Y=1392 TO STA Y=1430 IAW SRM 51-30-1 AND 51-30-2, NEW SECTION LONG WAS ADJUSTED AND DRILLED IAW SRM 51-10-4, LONG WAS TREATED AND PAINT ISDR DALA2014103005925Longeron · crackedCRACKED AFT ACC COMP LONGERON NR 13R AT INTERSECTION WITH FRAME 1380. SM, CARD 16, ZONE 61. LONGERON NR 13RT AT INTERSECTION WITH FRAME 1380 WAS REMOVED IAW SRM 51-30-2 AND 51-30-5; NEW LONGERON WAS DRILLED AND ADJUSTED IAW SRM 51-10-4, NEW LONGERON WAS TREASDR DALA2014102905871Cusp Web · corrodedCORROSION ON REPAIR DOUBLER FOR LT CUSP WEB BS 560-574 BETWEEN X=54 AND X=60. REPAIR REPLACED IAW SRM 53-05, FIG 13 1A-7 AND 51-30-5, 51-30-2, 51-10-3 PAR 14 AND 21.SDR DALA2014102905870Cusp Web · corrodedCORROSION FOUND ON REPAIR DOUBLER FOR THE LT CUSP WEB BS 1166, X=54. DOUBLER AND FILLER REPLACED IAW SRM 51-30-5, 53-05, FIG 131A-3, 51-10-3 PAR 14,21.SDR DALA2014102705753Skin · crackedCRACK IN FUSELAGE SKIN AND ATTACH ANGLE, FWD SIDE OF BS 1463 AT L-31. TAIL INTERIOR. REPAIRED IAW PRI530096-14, REV 1.SDR DALA2014102805817Wire · brokenDURING A LINE CHECK, MAINTENANCE FOUND THAT THE CENTER EMERGENCY LIGHT FOR THE CATWALK IN THE TAIL WAS INOPERATIVE. MAINTENANCE FOUND A WIRE BROKEN AT THE TERMINAL END. THE WIRE WAS REPAIRED AND THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014102805816Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT SEATS 15D & 20D WERE INOPERATIVE. MAINTENANCE REPLACED THE CONNECTOR IN THE WIRE HARNESS AT EACH SEAT AND THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA2014102605752Frame · crackedRIGHT VENT BOX FRAME BS 1463, AFT SIDE WEB CRACKED AT FASTENER AT 0200 POSITION. FRAME REPAIRED ON PRI/ERA 530243-14, REV ORIGINAL.SDR DALA2014111306107Angle · damagedELONGATED DRILL HOLE ON FRAME ANGLE BS 294 BETWEEN LONGERONS 19 - 22L. A NEW FRAME ANGLE AND SPLICE WERE FABRICATED, TREATED AND PAINTED AND INSTALLED IAW SRM 53-14-2, FIG 2, 51-10-2, 51-10-3 PAR 14/21, & 51-30-2.SDR DALA2014102805869Cusp Web · corrodedCORROSION FOUND ON REPAIR DOUBLER OF LT CUSP WEB BS 712, BETWEEN X=54 AND X=60. DOUBLER REPLACED IAW SRM 53-05, FIS IBIA-13, SRM 51-10-3, PAR 14, 21 SRM 51-30-5.SDR DALA2014102805868Cusp Web · corrodedCORROSION FOUND ON REPAIR DOUBLER OF LT CUSP WEB BS 430 BETWEEN X=54 AND X=60. DOUBLER REPLACED IAW 51-30-5, 51-30-1, 51-30-2, 53-05, FIG 131A-13 AND 51-10-3 PAR 14 AND 21.SDR DALA2014102805867Floor Panel · corrodedCORROSION ON FLOOR PANEL 256E. FLOOR PANEL REPAIRED IAW SRM 51-10-3, PAR 14, 21, 26 AND SRM 53-01, FIG 2.SDR DALA2014102805866Seat Track · corrodedCORROSION ON SEAT TRACK, RT X=-22, FROM BS 855 TO 858 AT PAX CABIN. REPAIRED IAW SRM 53-05, FIG 4A.SDR DALA2014102505750Frame · crackedCRACKED FRAME WEB AND INNER FRAME FLANGE, AFT SIDE OF BS 1485 . TAIL INTERIOR. REPAIRED IAW PRI 530093-14, REV 0 AND COMPLY WITH ERA 530093-14, REV ORIG.SDR DALA2014102705759Inlet · dirtyCREW REPORTED LIGHT HAZE AND BURNING ODOR IN FORWARD CABIN WITH FIRST CLASS LAVATORY SMOKE DETECTOR SOUNDING DURING CLIMBOUT. CREW REDUCED POWER AND HAZE/ODOR DISSIPATED. PROBLEM RETURNED WITH POWER RE-APPLIED. THE ACFT WAS RETURNED TO DEPARTURE. MAINTENANCSDR DALA2014102605751Longeron · crackedCRACKED LONGERON 9R BS 1413. LONGERON TRIMMED IAW SRM 53-02, FIG 18, NEW LONGERON SECTION DRILLEAD IAW SRM 51-10-4, SPLICE DRILLED AND ADJUSTED IAW SRM 51-10-4, AND 53-02, FIG 18, SHEET 1, NEW LONGERON INSTALLED IAW SRM 51- 30-2 AND 51-30-5.SDR WX0A2014102672226Light · wornFOUND ON WAKE UP, AFT TAIL CONE UPPER TWO LIGHTS FOR EMER LIGHTS INOPERATIVE. FOUND BOTH BULBS POSITIVE CONTACTS WORN OUT. RELAMPED, OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A2014102672225Battery · dischargedFOUND ON WAKE UP, EMER LIGHTS AT ROWS 21 & 22 INOPERATIVE. REPLACED BATTERIES, OPERATIONS CHECKED GOOD IAW AMM 33-51-01.SDR WX0A2014102672224Battery Pack · dischargedFOUND ON WAKE UP PORTABLE EMER BATTERY LIGHT INOPERATIVE & WILL NOT REMOVE. R & R PORTABLE EMER BATTERY PACK IAW AMM 33-53-00. LIGHTS OPERATE NORMAL.SDR DALA2014102305755Battery Pack · inoperativeCOCKPIT EMERGENCY LIGHT DOES NOT ILLUMINATE. REPLACED FORWARD BATTERY POWER PACK AND THE LIGHTS WERE OPERATIONAL.SDR DALA2014102305749Skin · debondedDEBONDED SKIN FWD OTBD EDGE OF 2.500" X 0.500" AND OUTBD EDGE OF 2500" X 0.500" AT LT HEATER BLANKET, SM, REPAIR WAS PERFORMED IAW AMM 30-80-02-801, PARA 2A, 9, 1674412.SDR DALA2014102305748Hinge · crackedCRACKS FOUND ON FWD AND AFT HINGE SECTION OF MID CARGO DOOR BARRIER, HINGE REMOVED IAW SRM 51-30-2, AND A NEW SECTION OF HINGE DRILLED IAW SRM 51-10-4.SDR DALA2014102305747Beam · crackedCRACKED BEAM FWD END NR 4 AT FWD SERVICE DOOR, R1, SM, CARD 7, ZONE 58. NEW BEAM WAS INSTALLED IAW SRM 51-30-1,51-30-2 AND 51-30-5.SDR DALA2014102305746Bulkhead · crackedCRACK ON FWD BULKHEAD PANEL BEAM STA Y=1003 X=22 AND Z=-1 AT AFT CARGO COMPARTMENT SUMMARY ANGLE WAS REMOVED CRACK STOPPED, REPAIR DOUBLER WAS TRIMMED AND DRILLED REPAIR DOUBLER WAS TREATED PAINTED AND INSTALLED ANGLE WAS INSTALLED REPAIR WAS IDENTIFIED IASDR DALA2014102305745Angle · crackedCRACKED ANGLE FWD AND AFT AT UPPER SUPPORTS MID CARGO DOOR (C2) (SH-CP-SM. ANGLE REMOVED IAW SRM 51-30-2 AND A NEW ANGLE FABRICATED IAW SRM 51-10-2. ANGLE TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14, AND WERE INSTALLED IAW SRM 51-30-2.SDR DALA2014102305719Barrier · damagedSEVERAL CRACKS BEYOND PREVIOUS STOP DRILLS ALSO ON PREVIOUS MID SCREW HOLES OF MID CARGO COMPARTMENT DOOR BARRIER. ANGLE WAS REMOVED IAW SRM 51-30-2 THEN ANGLE WAS FABRICATED IAW DWG 9935747, REV J THEN ANGLE WAS TREAT/PAINT IAW SRM 51-10-3, PAR 21 AND 14. TSDR DALA2014102305718Barrier · crackedSEVERAL CRACKS BEYOND PREVIOUS STOP DRILLS ALSO ON PREVIOUS MID SCREW HOLES OF MID CARGO COMPARTMENT DOOR BARRIER. DOUBLERS WERE REMOVED IAW SRM 51-30-2 DAMAGE WAS REMOVED IAW SRM 53-01, FIG 4, SHEET 4 DOUBLERS AND SPLICES WERE FABRICATE IAW SRM 53-01. DOSDR DALA2014102305717Floor Support · corrodedCORROSION ON UPPER FLOOR SUPPORT BS 1212 BETWEEN LONGERONS 28-29R. FOUND OUT LIMITS AND WAS REPLACED IAW SRM 51-30-5, 51-10-3 P. 14-21-26, 51-10-4.SDR WX0A2014102272218Battery · dischargedR1 & L1 EMER LIGHTS INOPERATIVE. REPLACED BATTERIES IN THE EXIT IDENT PACK IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.SDR DALA2014102005716Light · inoperativeDURING CHECK, MAINTENANCE FOUND THAT THE ROW 21 SEAT EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND OPS CHECKED GOOD.SDR DALA2014102005703Lamp · inoperativeDURING CHECK, MAINTENANCE FOUND THE SEAT EMERGENCY LIGHT AT SEAT 11D WAS INOPERATIVE. MAINTENANCE REPLACED THE LAMPS FOR BOTH SEAT EMERGENCY LIGHTS AND OPS CHECKED GOOD.SDR DALA2014102005702Battery Pack · inoperativeDURING CHECK, MAINTENANCE FOUND THE FIRST 3 ROWS OF CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN CHARGER B5-100 AND OPS CHECKED GOOD.SDR DALA1516840992Fitting · not reportedSLAT DRIVE FITTING REPAIRED IAW AA 2700-01074.SDR DALA2016111008615Bar · corrodedCORROSION ON FLEX JOINT LOWER BAR AT RT FLAP WAS REPAIRED IAW ER/A.SDR DALA1517100992Doubler · corrodedFUSELAGE AFT LAV SERVICE DOOR SURROUND DOUBLER CORRODED, BS 1307 REPAIRED IAW ERA 529789-14.SDR DALA2014102005715Slide Block · wornDURING CHECK, MAINTENANCE FOUND THE UPPER LT SLIDING BLOCK FOR THE TAIL CONE RELEASE CABLE WAS WORN. MAINTENANCE REPLACED BOTH THE UPPER LT AND RT CABLE BLOCKS AND A FUNCTIONAL TEST WAS PERFORMED.SDR DALA2014102005714Release Cable · corrodedDURING CHECK, MAINTENANCE FOUND THE TAIL CONE RELEASE CABLE CORRODED AND DAMAGED. MAINTENANCE REPLACED THE CABLE AND A FUNCTIONAL CHECK WAS PERFORMED.SDR DALA2014101805713Stringer · damagedSTRINGER DAMAGED. FABRICATED A REPAIR HAT CHANNEL AND REPAIR STRAP IAW PRI 529775-14.SDR DALA2014101805712Skin · corrodedCORROSION AROUND AND IN AFT LAVATORY SERVICE PANEL. REPAIRED IAW PRI 529789-14, REV 0 AND ERA 529789-14, REV ORIGINAL AND PRI 529923-14, REV "0" AND ER/A 529923-14, REV ORIGINAL.SDR DALA2014102705757Pan · corrodedAFT LAV SERVICE PAN CORRODED. REPLACED THE PAN.SDR DALA2014110705985Skin · corrodedCORROSION ON HORIZONTAL STABILIZER UPPER SKIN. CORROSION WAS REMOVED AND FOUND WITHIN LIMITS IAW SRM 55-03D, PAR 30. REPAIR BUSHINGS WERE FABRICATED AND INSTALLED IAW SRM 55-3. REPAIRED IAW ETI-88-14-219 REV ORIG AND ER/A 52935214, REV ORIG.SDR DALA2014110705984Skin · corrodedCORROSION ON HORIZONTAL STABILIZER UPPER SKIN. CORROSION REMOVED AND FOUND WITHIN LIMITS IAW SRM 55-03D, PAR 30. REPAIR BUSHINGS WERE FABRICATED AND INSTALLED IAW SRM 55.03.SDR DALA2014101705706Skin · corrodedCORROSION AROUND OUTFLOW VALVE SCOOP. BS 1285. REMOVED SKIN CORROSION AND CHECKED LIMITS TO BE WITHIN IAW SRM 53-01, PG 5. R & R VENT SUPPORT PLATE IAW DWG 5936021.SDR DALA2014101705705Door Frame · corrodedCORROSION ON MID CARGO BAY LOWER DOOR FRAME BEAM REPAIRED IAW ER/A 529350-14 MA, REV ORIGINAL AND SRM 53-05, FIG 123A.
Back to Mcdonnell Douglas MD-88