SDR DALA2014092205188Angle · crackedCRACKED ANGLE ON BS 1485 FRAME AT 11 O`CLOCK POSITION. ANGLE WAS FABRICATED IAW DWG 9911842-111, REV DH, SRM 51-30-5, 51-10-2, 51-10-3 PAR 14 AND 21.SDR DALA2014092205187Intercostal · crackedCRACKED INTERCOSTAL, BS 1022 - 1041 BETWEEN X=22 AND X=-22 . INTERCOSTAL REMOVED AND REPLACED IAW SRM 51-30-5, PAR 8 AND 51-30-2.SDR DALA2014092205154Charger · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTING IN THE VENTRAL STAIRWAY WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER AND THE BATTERIES. OPS CHECKED GOOD.SDR DALA2014100705427Cam · wornWORN TAILCONE RELEASE CAM BS 1510 AT 10 O'CLOCK POSITION. TAIL ONE RELEASE CAM REPLACED IAW AMM 53-53-02.SDR DALA2014092505237Access Panel · corrodedCORROSION ON COUNTERSINK ON FUEL ACCESS PANEL NR 1361C AT LT WING,. CORROSION ON COUNTERSINK HOLES WAS REMOVED AND WAS FOUND TO BE OUT OF LIMITS AND WAS REPLACED IAW 51-22-2A .SDR DALA2014092405232Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA ON FUEL ACCESS PANEL NR 1367C AT LT WING. CORROSION ON SETLEMENT AREA WAS REMOVED, COUNTERSINK HOLES WERE MEASURED AND FOUND OUT OF LIMITS. THE ACCESS PANEL WAS REPLACED IAW SRM 51-22-2A.SDR DALA2014092405231Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA ON FUEL ACCESS PANEL NR 1454C AT RT WING. CORROSION ON SETLEMENT AREA AND COUNTERSINK WAS REMOVED, AND FOUND TO BE OUT OF LIMITS. REPLACED IAW SRM 51-22-2A .SDR DALA2014092205208Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY OVERHEAD LIGHTING AT THE OVERWING EXIT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK B5-104 AND THE LIGHTS RETURNED TO AN OPERATIONAL STATE.SDR DALA2014092205207Release Cable · frayedMAINTENANCE DISCOVERED THAT THE TAILCONE EMERGENCY RELEASE CABLE WAS FRAYED BEYOND ALLOWABLE LIMITS. THE CABLE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE RII STEPS WERE COMPLETED.SDR DALA2014092105186Strip · corrodedCORROSION ON STRIP BELOW LONGERON 26 LT BS 1188-1200 IN CARGO BAY. STRIP REPAIRED IAW SRM 51-30-2;51-10-3 P 26,21,14, 51-30-5; 53-04 FIG 12D, 12F, AND ER/A 511165-14MA, REV B.SDR DALA2014092105176Door · crackedWEAR AND CRACK ON RT SLAT TRACK DOOR NR 11. SLAT TRACK DOOR WAS FABRICATED IAW ERA 512356-14 MA REV ORIGINAL.SDR DALA2014092105175Door · crackedCRACK ON LEFT SLAT TRACK DOOR NR 3. SLAT TRACK DOOR WAS FABRICATED IAW ERA 512356-14, MA REV ORIGINAL.SDR DALA2014092005174Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA ON FUEL ACCESS PANEL NR 1464C AT RT WING. CORROSION ON COUNTERSINK AND SETTLEMENT AREA WAS REMOVED IAE SRM 51-22-2A AND FOUND OUT LIMITS IAW SRM 51-22-2A AND WAS REPLACED.SDR DALA2014092005172Access Panel · corrodedCORROSION ON SETTLEMENT AREA AND COUNTERSINK ON FUEL ACCESS PANEL NR 1462C AT RT WING. CORROSION ON COUNTERSINK AND SETTLEMENT AREA WAS REMOVED IAW SRM 51-22-2A AND FOUND OUT OF LIMITS IAW SRM 51-22-2A.SDR DALA2014092005171Access Panel · corrodedCORROSION ON CONUNTERSINK AND SETTLEMENT AREA ON FUEL ACCESS PANEL NR 1456C AT RT WING. CORROSION ON COUNTERSINK AND SETTLEMENT AREA WAS REMOVED IAW SRM 51-22-2A AND FOUND OUT OF LIMITS.SDR DALA2014092005170Access Panel · corrodedCORROSION ON COUNTERSINK ON FUEL ACCESS PANEL NR 1357C AT LT WING,. CORROSION ON COUNTERSINK AND SETTLEMENT AREA WAS REMOVED IAW SRM 51-22-2A AND FOUND OUT OF LIMITS IAW SRM 51-22-2A.SDR DALA2014092005169Door Frame · crackedCRACKED LT MLG DOOR FRAME BS 984. FRAME REMOVED IAW SRM 51-30-2 AND A NEW FRAME WAS DRILLED IAW SRM 50-10-4 AREA, TREATED AND PAINTED IAW SRM 51-10-3 AND INSTALLED IAW SRM 51-30-1 AND 51-30-2.SDR DALA2014092005168Support · crackedCRACKED SUPPORT BS 1485 LONGERON 24 LT. SUPPORT REPLACED IAW DWG 9911946, 3 REV R, SRM 51-30-2, 51-20-4, M51-20-3 PAR 14 AND 21 AND 51-30-5.SDR DALA2014092105210Doubler · corrodedCORROSION ON INNER DOUBLER OF AFT LAVATORY SERVICE PANEL. INNER DOUBLER WAS REPAIRED IAW ERA 397822-14, MA REV A.SDR DALA2014092205153Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 23D IN THE CABIN WAS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND PERFORMED A SATISFACTORY FUNCTIONAL CHECK OF IT.SDR DALA2014092305194Floor Support · damagedELONGATED HOLES ON FLOOR SUPPORT BS 1079 - 1117, BETWEEN LONGERONS 28LT AND 28RT IN AFT CARGO BAY. FLOOR SUPPORT REPLACED IAW SRM 51-30-5 AND 51-10-4.SDR DALA2014092005167Hinge Fitting · corrodedCORROSION ON HINGE FITTING OF R1 SLIDE DOOR. FITTINGS WERE REPLACED IAW SRM 51-10-3 AND 51-10-4, DWG 3936190.SDR DALA2014091905165Cusp Web · crackedNDT FOUND A CRACK OF 0.625 ON LT CUSP WEB BETWEEN X=54 AND X=60 BS 825-826. LT CUSP WEB BETWEEN X=54 AND X=60 AND Y=825-826 WAS REPAIRED IAW SRM 53-05, FIG 131A-1.SDR DALA2014091905164Intercostal · crackedCRACK ON INTERCOSTAL BS 210, LONGERON 15 L . INTERCOSTAL REPLACED IAW SRM 51-30-2 AND DWG 9957884, REV H.SDR DALA2014091805163Spacer · corrodedCORROSION ON AFT CARGO DOOR LOWER FRAME BEAM REPAIR SPACER BETWEEN BS 1155-1212. SPACER WAS REPLACED IAW SRM 53-05, FIG 123.SDR DALA2014091805162Door Frame · corrodedCORROSION ON AFT CARGO LOWER DOOR JAMB BEAM HORIZONTAL L/E BELOW PREVIOUS REPAIR DOUBLER BETWEEN BS 1158-1205. REPAIR DOUBLER WAS REPLACED IAW SRM 53-05, FIG 123.SDR DALA2014091805161Floor Support · corrodedCORROSION AND ELONGATED HOLES ON FLOOR SUPPORT AT BS 1155. CORROSION REMOVED IAW SRM 51-10-3 PAR26. FOUND TO BE OUT OF LIMITS IAW SRM 53-01-FIG1 AND WAS REPLACED IAW SRM 51-10-04 AND DWG 5936660, REV BZ.SDR DALA2014092105152Spar Cap · crackedRT HORIZONTAL STABILIZER REAR SPAR UPPER CAP INBD END, 1EA CRITICAL FASTENER HOLE, UPPER-OTBD, HAS A CRACK APPROXIMATELY .2500" LONG. REMOVED REAR, UPPER & LOWER SPAR ASSY AT RT HORIZONTAL STABILIZER CUT REAR UPPER SPAR SECTION, 34". MATCH DRILLED, TRIMMED SDR DALA2014092105151Spar · crackedHORIZONTAL STABILIZER REAR SPAR FOUND CRACKED. HFEC AREA ONE CRACK, NOTED, REMOVED UPPER & LOWER REAR SPAR ASSY, CUT DAMAGED AREA DIM: 34", MATCH DRILL & TRIMMED NEW UPPER CHORD SECTION -13, REPLACEMENT. LOCATED, DRILLED, DEBURRED, TREATED, PRIMED & INSTALLESDR DALA2014091905150Spar · crackedRT WING REAR SPAR CRACKED, XRS 164, EMITTING APPROX 0.375 FROM INBD FLAP HINGE. CONFIRMED WITH EDDY CURRENT. INSTALLED REPAIR ON STA 164 RT LOWER SPAR CAP IAW AMDS 5710-01110-06, JO 060271-510, AND ER/A 529017-14AD.SDR DALA2014091805145Doubler · wornWEAR ON INNER DOUBLER OF TITANIUM AT AFT LAVATORY SERVICE PANEL TRAY. DOUBLER WAS REPLACED IAW DWG 5911423, REV CD AND SRM 51-30-2, SRM 51-30-5, SRM 51-10-3, PAR 14.SDR DALA2014091805144Fitting · crackedCRACKED FITTING BS 1350 AND X-5. FITTING WAS R & R IAW SRM 51-30-2 AND DWG 5917579, REV EE.SDR DALA2014091905117Lamp · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT SEVERAL OF THE OVERHEAD EMERGENCY LIGHTS WERE INOPERATIVE. REPLACED LAMP EACH LIGHT, BUT THE LIGHT ASSEMBLY AT THE RT FORWARD OVERWING EXIT REQUIRED REPLACEMENT. A SATISFACTORY FUNCTIONAL CHECK WAS PERFORMED FOLLOWINSDR DALA2014091805160Structure · damagedDURING CHECK, CRACK AND GOUGES IN SKIN WAS FOUND BS 1418 STRINGER 2.SDR DALA2014091805143Cusp Web · corrodedCORROSION ON RT CUSP WEB BS 834 - 838 BETWEEN X-54 TO X-60 . CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 131A-14, SRM 51-10-3, PAR 14 21.SDR DALA2014091905118Linkage · damagedTHE TAILCONE CATWALK OVER THE VENTRAL STAIRWAY, RT SIDE LINKAGE WAS FOUND DAMAGED. THIS IS CONSIDERED A DEFECT IN THE EMERGENCY ESCAPE SYS AND COULD HAVE AN ADVERSE AFFECT ON THE EVACUATION ROUTE. THE LINK AT THE RT SIDE TORSION BAR WAS REPLACED, THE MOVEABLSDR DALA2014091805116Terminal · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING FOR THE MIDDLE OF THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE FOUND A BROKEN TERMINAL END, RETERMINATED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.SDR DALA2014091805114Seat Track · corrodedCORROSION ON SEAT TRACK X - 44, BS 213-216. DAMAGED AREA WAS REPAIRED IAW SRM 53-05, FIG 4A.SDR DALA2014101405533Frame · corrodedCORROSION ON FRAME ANGLE BS 1193 BETWEEN LONGERONS 29 - 30L . FRAME ANGLE WAS REPLACED IAW SRM 51-10-3, PAR 14, 21, 53-01, FOG 1, 53-03.SDR DALA2014091605063Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHT IN THE FIRST CLASS SECTION WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS FOR THE NOTED LIGHTED AREAS AND OPS CHECKED GOOD.SDR DALA2014091805112Skin · corrodedCORROSION FOUND ON INBD AND OTBD FACE OF VERTICAL STABILIZER PLATES, ZRS= 178. CORROSION WAS REMOVED IAW SRM 55-02, PAR 24 AND 51-10-3, PAR 26, 21, 14.SDR DALA2014091605062Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTS IN FIRST CLASS SECTION WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS AND THE OPS CHECKED GOOD.SDR DALA2014092005166Stop Fitting · crackedCRACK ON FWD STOPS NR 2 AND 4 AT FWD CARGO BAY DOOR. CRACK STOP FITTING WERE REMOVED IAW SRM 51-30-1 AND 51-30-5. NEW STOPS WERE DRILLED IAW SRM 51-10-4. NEW STOP FITTINGS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21 NEW STOP FITTING NR 2 AND 4 WSDR DALA2014091805111Shear Tie · crackedCRACKED SHEAR TIE BS 1380 BETWEEN LONGERONS 13 - 14R. NEW SHEAR TIE WAS FABRICATED AND PAINTED TREATED IAW SRM 53-14-4 AND 51-10-3 PAR 14,21.SDR DALA2014091505087Cusp Web · corrodedCORROSION ON RT CUSP WEB BETWEEN BS 674 - 693 AND X-54 TO X 60 . RT CUSP WEB REPAIRED IAW SRM 53-05, FIG 131A-5.SDR DALA2014091505086Attach Angle · crackedCRACKED RT ATTACH ANGLE FUSELAGE AT LONGERON 20R BS 1003. REPAIRED IAW SRM 53-02, FIG 22.SDR DALA2014091505085Channel · crackedCRACKED CHANNEL N2 FROM ROOT TO TIP ON REAR SPAR OF HORIZONTAL STABILIZER RT SIDE. . CHANNEL WAS FABRICATED IAW SRM 55-12-0, FIG 4, 51-10-3, PAR 21 AND 14.SDR DALA2014091505084Floorbeam · crackedCRACK FLOORBEAM ANGLE BS 120 X -54 Z 0. R & R FLOORBEAM ANGLE IAW DWG 9911559-8, SRM 51-10-3, PARA 21 & 14, SRM 51-30-5.SDR DALA2014091505083Floorbeam · crackedCRACKED FLOORBEAM ANGLE BS 120, X 54 Z 0. R & R FLOORBEAM ANGLE IAW DWG 9911559-7, SRM 51-10-3, PARA 21 & 14, SRM 51-30-5.SDR DALA2014091605079Battery Pack · inoperativeDURING CHECK, MAINTENANCE FOUND THE OVERHEAD EMERGENCY LIGHTS WERE INOPERATIVE IN THE FWD GALLEY AND ENTRYWAY. MAINTENANCE REPLACED THE BATTERIES IN THE FORWARD EMERGENCY LIGHT POWER SUPPLY AND THE LIGHTS CHECKED GOOD.
Back to Mcdonnell Douglas MD-88