SDR WX0A2014080572073Circuit Breaker · faultyR CSD GAUGE RISE FUNCTION INOPERATIVE. REF LOG PG 507302 REPLACED CSD OIL TEMP B1-179. OPERATIONS CHECKED GOOD IAW MM 24-10-01. 7/29/14 R & R RELAY R2-80, NO HELP. R & R CB B1-179 & FIXED PROBLEM. NO REPEATS OR HISTORY. 8/5/14 NO REPEATS AFTER CB REPLACESDR DALA2014072404208Cusp Web · corrodedCORROSION ON REPAIR OF RT CUSP WEB X= -54 TO X=60 BETWEEN BS 731 - 750. REPAIR WAS REPLACED IAW SRM 53-05, FIG 131A-14, 51-30-2, 51-10-3, PAR 14, 21 51-10-3, PAR 38.SDR DALA2014080304443Longeron · crackedCRACK ON LONGERON 2L BS 1418. LONGERON REPLACED IAW SRM 53-14-4.SDR DALA2014080304435Structure · wornREPAIR DOUBLER OF AFT HINGE AT AFT CARGO DOOR WORN. AFT CARGO DOOR HINGE WAS REMOVED IAW AMM 52-31-02, DOUBLER REMOVED IAW SRM 51-30-2, DOUBLER FABRICATED IAW SRM 52-05, FIG 35A. NEW DOUBLER TREATED AND PAINTED IAW SRM 51-10-3, PAR 14/21 AND INSTALLED IAW SDR DALA2014072304202Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE SEAT MOUNTED EMERGENCY EXIT LIGHT AT THE OVERWING EXIT ROW WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.SDR DALA2014072304199Release Mech · wornMAINTENANCE DISCOVERED THAT THE TAILCONE RELEASE MECHANISM CAM BASE WAS WORN OUT OF ALLOWABLE LIMITS. THE CAM BASE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE RII WAS SATISFACTORY.SDR DALA2014072304198Release Cable · wornMAINTENANCE DISCOVERED THAT THE TAILCONE EMERGENCY RELEASE CABLE WAS TORN AT CAM LOOP. THE CABLE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS.SDR DALA2014072704231Structure · corrodedCORROSION ON HORIZONTAL STABILIZER LT/RT HINGES PLATES INNER SURFACES AT VERTICAL STABILIZER. CORROSION WAS REMOVED IAW SRM 51-10-3, SRM 55-02, FIG 28, SRM 51-10-3, PAR. 14.SDR DALA2014072304195Rib · corrodedCORROSION ON LT SLAT PANEL NR 2 RIB FITTING FWD LUG HOLE STA XOS=285, CARD 14, ZONE 11 CORROSION ON LT SLAT PANEL NR 2 RIB FITTING FWD LUG HOLE STA XOS 285 WAS REMOVED WITH A ID 01.1225" AND WAS INSTALLED A BUSHING WITH AN OD 0 1.123" IAW SRM 57-02.SDR DALA2014072304194Cusp Web · corrodedCORROSION ON LT CUSP WEB REPAIR DOUBLER BS 682-688, X =54-60. CORROSION REMOVED IAW SRM 51-30-2, 55- 05, FIG 131A-13, 51-10-3, PAR 14 AND 21 AND 51-10-3, PAR 38.SDR DALA2014072204201Bushing · wornMAINTENANCE DISCOVERED THAT THE TEE PIN AND THE TEE PIN BUSHING WERE WORN BEYOND ALLOWABLE LIMITS AND REPLACED.SDR DALA2014072204193Fastener · looseMAINTENANCE DISCOVERED THAT THE FASTENERS FOR THE SPADE RECEPTACLE FOR THE TAILCONE WERE WORN OUT OF ALLOWABLE LIMITS. THE RIVETS WERE REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR DALA2014072704230Cusp Web · corrodedCORROSION ON LT CUSP WEB REPAIR DOUBLER BS 452-568 X=60 - 54. REPAIR DOUBLER WAS REPLACED IAW SRM 53-05, FIG 131A-2.SDR DALA2014072304196Cusp Web · corrodedCORROSION ON PREVIOUS REPAIR OF RT CUSP WEB X=-54 TO X=60, BETWEEN BS 769 - 788. CORROSION WAS REMOVED IAW SRM 51-30-2, 55-05, FIG 13 1A-13, 51-10-3 PAR 14 AND 21, AND 51-10-3, PAR 38 AND PS 900-5-1 N 04.SDR DALA2014072204190Door Frame · crackedCRACKED OVERWING FRAME, BS 886 LT. FRAME REPLACED IAW EM 5310-01414, SEC.0301.SDR DALA2014072104186Skin · corrodedEXTERIOR SKIN PILLOWED WITH STRESSED BS 206, L21R. SKIN REPAIRED IAW SRM 53-04-3, FIG 2.SDR DALA2014072104185Longeron · corrodedLONGERON 21R CORRODED FULL THRU AT BS 206 . REPAIRED IAW SRM 53-02-FIG 18.SDR DALA2014072104200Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT ROWS 22-30 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA2014072704233Rib · corrodedCORROSION ON LT SLAT PANEL NR 3, RIB FITTING FWD LUG HOLE STA XOS=285. CORROSION ON LT SLAT PANEL NR3 RIB FITTING FWD LUG HOLE STA XOS =285 WAS REPAIRED IAW SRM 57-02, PAR 9 WITH A BUSHING ON THE HOLE.SDR DALA2014072804239Floor Panel · damagedDAMAGED FERRULE IN AFT CABIN FLOOR PANEL. FLOOR PANEL FABRICATED AND REPLACED FERRULE IAW AMM 53-20-01-201.SDR DALA2014072804237Floor Panel · delaminatedDELAMINATED FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR DALA2014072204189Web · puncturedPUNCTURE ON LT WEB BS 200, BETWEEN X=22 TO X=26 AT PAX CABIN FLOOR STRUCTURE. DAMAGE WERE REMOVED IAW SRM 51-10-4 AND 53-01 HOLES WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21 PLUGS WERE INSTALLED IAW SRM 51-10-3 AND 51-10-4.SDR DALA2014072004183Cusp Web · corrodedCORROSION ON REPAIR OF RT CUSP WEB X=-54 TO X=60 BETWEEN BS 750 - 769. REPAIR REPLACED IAW SRM 53-05, FIG 131A-13.SDR DALA2014072104188Release Cable · out of rigMAINTENANCE DISCOVERED THAT THE TAILCONE RELEASE CABLE WAS OUT OF ALLOWABLE RIG LIMITS. THE CABLE WAS ADJUSTED AND THE SYSTEM WAS RIGGED BACK INTO SPECIFICATIONS. THE RII STEPS WERE COMPLETED.SDR DALA2014071904182Angle · corrodedACFT FAILED FUNCTIONAL CHECK OF TAILCONE RELEASE SYS DUE TO THE TEE PIN ANGLES CORRODED AND TIGHT. THE ANGLES WERE REPLACED AND THE FUNCTIONAL CHECK WAS GOOD.SDR DALA2014071904181Skin · damagedFUSELAGE SKIN DENTED AND SCRATCHED BS 1304 ABOVE L19R. ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-04-2 PARA 3C, FIG 2, PAGE 27.SDR DALA2014071904180Frame · crackedTAIL INTERIOR CRACKED BS 1485 CANTED FRAME WEB. CONFIRMED WITH HFEC. TREATED, PRIMED AND INSTALLED REPAIR IAW SRM 53-03D, FIG 48.SDR DALA2014072304179Engine · failedTHE NR 1 ENGINE FAILED DURING TAKEOFF. FLIGHT RETURNED TO DEPARTURE. PILOTS HEARD A THUD, NOTICED LT ENGINE ROLLED BACK AND SHUTDOWN, AND THE EGT INCREASED. THE QRH WAS COMPLIED WITH AND THE FUEL WAS SHUTOFF. MAINTENANCE FOUND METAL IN TAIL PIPE AND TURBINESDR WX0A2014072272039Battery · dischargedFORWARD DEFRIB BATTERY DEAD & PAD INTERMITTENTLY INOPERATIVE. R & R FWD DEFRIB AT BATTERY IAW MM25-60-01.SDR DALA2014071804160Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 27D WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND THE SYS RETURNED TO NORMAL OPERATION.SDR DALA2014071804156Bushing · wornMAINTENANCE DISCOVERED THAT THE TEE PIN BUSHING WAS WORN BEYOND ALLOWABLE LIMITS AND REQUIRED REPLACEMENT.SDR DALA2014072704236Cusp Web · corrodedCORROSION ON RT CUSP WEB BETWEEN X=-44, BS 958 - 973. CUSP WEB REPAIRED IAW SRM 53-05, FIG 131A-15, 51-10-3 PAR 14 AND 21.SDR DALA2014072404204Channel · brokenMAINTENANCE DISCOVERED THAT THE TAILCONE CATWALK OVER THE VENTRAL STAIRWAY HAD GOTTEN STUCK HALF WAY THROUGH TRANSITION WHEN LOWERING THE STAIRS. CAUSE OF BINDING WAS BROKEN CHANNEL EXTRUSION ON THE STAIR AREA SIDEWALL. THIS IS CONSIDERED A DEFECT IN THE EMESDR DALA2014071804159Skin · gougedFOUND TWO GOUGES ON RT WING INBD FLAP LOWER SKIN. REPAIRED GOUGES IAW SRM 57-01, FIG 1 AND 57-03D, FIG 8.SDR DALA2014071804158Floor Support · corrodedCORROSION ON FLOOR STRUCTURE LT AND RT OF FLOOR PANEL 160C AFT OF COCKPIT DOOR. REPAIRED IAW ER/A 527590-14.SDR DALA2014071804157Cam · wornMAINTENANCE DISCOVERED THAT THE TAILCONE RELEASE MECHANISM CAM BASE WAS WORN OUT OF ALLOWABLE LIMITS. THE CAM BASE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS.SDR DALA2014071704154Release Cable · frayedMAINTENANCE DISCOVERED THAT THE TAILCONE EMERGENCY RELEASE CABLE WAS FRAYED BEYOND ALLOWABLE LIMITS. CABLE REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS.SDR DALA2014071704153Pin · wornMAINTENANCE DISCOVERED THAT THE RELEASE LATCH TEE PIN FOR THE TAILCONE WAS WORN OUT OF ALLOWABLE LIMITS. TEE PINS WERE REPLACED AND THE SYS WAS RIGGED TO SPECIFICATIONS. FUNCTIONAL CHECKED SATISFACTORILY.SDR WX0A2014071872034Flashlight · inoperativeFWD EMER FLASH LIGHT INOPERATIVE. R & R EMER FLASHLIGHT IAW AMM 25-60-00.SDR DALA2014071704152Skin · crackedACFT SKIN HAS A ONE INCH LONG CRACK AT BS 1380, ONE INCH ABOVE LONGERON 14L. REPAIR INSTALLED IAW PRI 527562-14, REV 0.SDR DALA2014072104187Skin · crackedCRACK ON FUSELAGE SKIN BS 1380 BETWEEN LONGERONS 13 - 14R. REPAIRED IAW SRM 53-04, FIG 18, SRM 51-10-3, PAR 21-14, SRM 51-30-2, SRM 51-30-5.SDR DALA2014071504114Cable · brokenFOUND L1 DOOR SLIDE GIRT BAR CABLE TO BE BROKEN. R & R GIRT BAR LANYARD IAW AMM 25-60.SDR DALA2014071504113Seat Track · corrodedCORROSION ON RT SEAT TRACK PLUGS, BS 412-432 X=-54. DAMAGE PLUGS WERE REMOVED AND NEW PLUGS WERE REWORKED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-1, 53-05 AND 51-10-3, PAR 21 AND 14.SDR DALA2014071504112Seat Track · corrodedCORROSION ON RT SEAT TRACK PLUGS X=-54, BS 661 - 681. DAMAGED PLUGS WERE REMOVED AND NEW PLUGS WERE REWORKED TREATED, PAINTED AND INSTALLED IAW SRM 51-30-1, 53-05 AND 51-10-3, PAR 21 AND 14.SDR DALA2014071504111Seat Track · corrodedCORROSION ON LT SEAT TRACK BETWEEN BS 610-613. , DAMAGE REMOVED AND REWORKED AND INSTALLED IAW SRM 51-30-1,53-05 AND 51-10-3,SDR DALA2014071504110Skin · crackedAFT FUSELAGE SKIN CRACKED AT BS 1380, 10 INCHES ABOVE RT PYLON. COMPLIED WITH PRI 527352-14, REV O AND REPAIRED IAW ERA 527352-14, REV ORIGINAL.SDR DALA2014071404109Receptacle · wornMAINTENANCE DISCOVERED THAT ONE OF THE TAILCONE RELEASE SYSTEM LATCH PIN RECEPTACLES WAS WORN BEYOND ALLOWABLE LIMITS. THE RECEPTACLE WAS REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR DALA2014071404108Pin · damagedMAINTENANCE DISCOVERED THE L1 DOOR SLIDE CABLE PINS WERE MISSING THE SECURITY STRING. MAINTENANCE R & R THE L1 SLIDE.SDR DALA2014071404107Connector · disconnectedDURING CHECK, MAINTENANCE FOUND THE EMERGENCY PATH IN SEAT LIGHTS WERE INOPERATIVE AT ROWS 11 AND 16. MAINTENANCE FOUND THE CONNECTORS DISCONNECTED AND THEY RECONNECTED THEM. LIGHTS RETURNED TO AN OPS STATE.SDR DALA2014071404095Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY LIGHTING FROM THE L2 DOOR TO ROW 27 WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS FOR THE NOTED LIGHTED AREAS AND THE OPS CHECKED GOOD.
Back to Mcdonnell Douglas MD-88