Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014080304444Doubler · wornFWD REPAIR DOUBLER ON FWD CARGO DOOR WORN. DAMAGE DOUBLERS REMOVED AND REPLACED IAW SRM 51-30-2, SRM 52-05D FIG 806D, SRM 51-10-3 PAR 14 AND 21, AND INSTALLED IAW 51-30-2.SDR DALA2014073104287Pushrod · disconnectedDURING TAKEOFF ROLL, F/O COULD NOT STEER THE ACFT WITH RUDDER PEDALS. TAKEOFF ABORTED AND EXITED THE RUNWAY USING THE TILLER. MAINTENANCE FOUND THE RUDDER PEDAL STUCK AND BRAKE PUSH ROD ON THE F/O SIDE DISCONNECTED. SECURED THE ROD AND OPS CHECKED GOOD.SDR DALA2014080104329Cusp Web · corrodedCORROSION ON LT CUSP WEB AND REPAIR DOUBLER BS 826-845 X=54-60. CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 131A-6.SDR DALA2014073104328Longeron · crackedCRACK ON LONGERON 16L, BS 1437 IN AFT ACCESSORY BAY. LONGERON REPLACED IAW SRM 53-14-4 AND 51-30-2, 51-10-3 PAR 21, 24.SDR DALA2014073104325Cusp Web · corrodedCORROSION ON CUSP WEB BS 237-256 BETWEEN X=54 AND X=60. CUSP WEB REPAIRED AND INSTALLED, IAW SRM 53-05 FIG 161, A-14, AND SRM 51-10-3 PAR 14 AND 21 AND SRM 51-30-2 AND 51-30-5.SDR DALA2014073104324Bushing · corrodedCORROSION ON BUSHING ON AFT EDGE OF RT WING HEATER BLANKET. BUSHING REPLACED IAW SRM 51-30-10.SDR DALA2014073004312Cusp Web · corrodedCORROSION ON CUSP WEB X=-54 TO -60 BS 1184-1233 RT SIDE. FASTENERS AND CORROSION WERE REMOVED IAW SRM 51-30-2 AND 51-30-3, PAR-26.SDR DALA2014073004311Access Panel · corrodedCORROSION ON LT MAIN FUEL TANK ACCESS PANEL 1365C, COUNTERSINK HOLES. ACCESS PANEL WAS REPLACED.SDR DALA2014073004310Access Panel · corrodedCORROSION ON SETTLEMENT AREA OF ACCESS PANELS 1414C, 1409C, 1436C, 1410 ON RT WING UPPER SURFACE. CORROSION REMOVED IAW SRM 51-22-2A. ACCESS PANELS REPLACED.SDR DALA2014073004309Access Panel · corrodedCORROSION ON LEFT MAIN FUEL TANK ACCESS PLATE 1371C COUNTERSINK HOLES. ACCESS PANEL WAS REPLACED.SDR DALA2014073004308Access Panel · corrodedCORROSION ON LT MAIN FUEL TANK ACCESS PANEL 1373C COUNTERSINK HOLES. ACCESS PANEL WAS REPLACED.SDR DALA2014073004305Cusp Web · corrodedCORROSION ON RT CUSP WEB, X=-54 TO X=-58 FROM BS 561 - 712. CORROSION REMOVED IAW SRM 51-10-3 PAR 21, 14 AND 26 IAW ER/A 508307-14, A REV A.SDR DALA2014073004304Pan · crackedCRACK ON PAN AT FWD UPPER CORNER OF RT FWD EMERGENCY EXIT DOOR. FWD UPPER CORNER PAN WAS REPAIRED IAW SRM 52-05D, FIG 51.SDR DALA2014073004303Longeron · crackedCRACK ON LONGERON 3L BS 160. LONGERON REPAIRED IAW SRM 53-02, FIG 18, 51-30-2 AND 51-30-5.SDR DALA2014081504614Pan · crackedCRACK ON PAN AT FWD UPPER CORNER OF LT FWD EMERGENCY EXIT DOOR. PAN WAS REPAIRED IAW SRM 52-05D, FIG 51.SDR DALA2014080304446Skin · damagedLIGHTNING STRIKE ON FUSELAGE SKIN BETWEEN LONGERONS 4-5R, BS 617-693. REPAIRED IAW SRM 53-04-1, PAR 6C, 2, COND 2 AND 53-04-1 PAR 6D, 1 COND 1 ALSO SRM 51-30-2.SDR DALA2014080204330Seat Track · wornLT SEAT TRACK X=54 BETWEEN BS 797-1006 WORN. WEAR REMOVED IAW SRM 51-10-3, PAR 26. FOUND OUT OF LIMITS IAW SRM 53-05, FIG 4B. SEAT TRACK REPLACED IAW SRM 53-05, FIG 4F.SDR DALA2014073004307Cusp Web · corrodedCORROSION ON REPAIR DOUBLER X=-55 TO X=-60, BS 523 - 530 ON RT CUSP WEB. REPAIR DOUBLER REPLACED IAW SRM 53-05, FIG 131A.SDR DALA2014072804248Access Panel · corrodedCORROSION ON LT MAIN FUEL TANK ACCESS PANEL 1355C. ACCESS PANEL REPLACED.SDR DALA2014072804247Access Panel · corrodedCORROSION ON LT MAIN FUEL TANK ACCESS PANEL 1307C. ACCESS PANEL REPLACED.SDR DALA2014072804246Access Panel · corrodedCORROSION ON RT MAIN FUEL TANK ACCESS PANEL 1464C. FUEL TANK ACCESS PANEL REPLACED.SDR DALA2014072804245Access Panel · corrodedCORROSION ON RT MAIN FUEL TANK ACCESS PANEL 1454C. ACCESS PANEL REPLACED.SDR DALA2014072804244Access Panel · corrodedCORROSION ON RT MAIN FUEL TANK ACCESS PANEL 1456C. ACCESS PANEL REPLACED.SDR DALA2014072804243Access Panel · corrodedCORROSION ON RT MAIN FUEL TANK ACCESS PLATE 1478C. ACCESS PANEL REPLACED.SDR DALA2014072804242Access Panel · corrodedCORROSION ON LT MAIN FUEL TANK ACCESS PANEL 1357C. ACCESS PANEL REPLACED.SDR DALA2014072804241Cusp Web · corrodedCORROSION ON LT CUSP WEB REPAIR DOUBLER BS 644-655 X=54-60. REPAIR REPLACED IAW SRM 53-05, FIG 131A-14 AND 51-30-2, 51-10-3 PAR 14-21.SDR DALA2014073004306Frame · crackedCRACK ON FRAME, BS 1451 LONGERON 1, AFT ACCESSORY BAY, FRAME REPLACED IAW SRM 51-30-2 AND 51-30-5, 51-10-3, PAR 21 AND 14 DWG 99118060-3, REV= L.SDR DALA2014072804251Receptacle · wornMAINTENANCE DISCOVERED THAT SEVERAL OF THE TAILCONE RELEASE SYSTEM GUIDE PIN RECEPTACLES WERE WORN BEYOND ALLOWABLE LIMITS. THE RECEPTACLES WERE REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR DALA2014072804250Door Frame · corrodedCENTER CARGO DOOR CUTOUT LOWER DOOR FRAME SURFACE HAS CORROSION , BS 636 - 693. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FABRICATED AND INSTALLED PERMANENT REPAIR IAW SRM 53-05, FIG 123, OPTION 1.SDR DALA2014082604733Cusp Web · corrodedCORROSION ON LT CUSP WEB UPPER/LOWER SURFACE, STA Y=465-484 AND Y=541-557 X=54-60 AT CABIN FLOOR STRUCTURE, MRB 53- 037-01, SM, CARD 53, ZONE 201. CORROSION WAS ATTENDED IAW SRM 51-10-3, PAR 26, 21, 14 AND 38 CORROSION ON STA Y=545 WAS FOUND AOUT LIMITS THERESDR DALA2014080904490Longeron · crackedCRACK ON LONGERON 12L, BS 1437. REMOVED AND REPLACED THE LONGERON AND SPLICE IAW SRM 51-30-2, 51-30-5, 53-02 PAR 12, 51-10-4, 51-10-3 PAR 14 AND 21.SDR DALA2014072804249Floor Support · crackedCRACKED FLOOR SUPPORT BS 984 - 965 X=-34 . FLOOR SUPPORT REMOVED, NEW FLOOR SUPPORT DRILLED, ADJUSTED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-5 51-10-4, 51-10-3, PAR 21 AND 14.SDR DALA2014072804240Floor Panel · debondedDISBONDED HONEYCOMB IN AFT CABIN FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR DALA2014072904255Annunciator · failedDIVERTED DUE TO SMOKE IN THE COCKPIT. THE CREW REPORTED THE CAPTAIN`S FLIGHT MODE ANNUNCIATOR SMOKING AND ARCING. MAINTENANCE REPLACED THE CAPTAIN`S FMA ALL RTS WERE GOOD.SDR DALA2014072804254Pin · unsecureDURING INSPECTION OF THE L1 DOOR SLIDE, MAINTENANCE FOUND THE SLIDE PIN NOT ENGAGED AND SLIDE PARTIALLY INFLATED. MAINTENANCE R & R THE SLIDE PACK.SDR DALA2014072804253Battery Pack · inoperativeDURING CHECK, MAINTENANCE FOUND THE 2 EMERGENCY LIGHTS IN THE CEILING ABOVE THE VENTRAL EGRESS RAMP WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AT B5-27 AND THE LIGHT WERE OPERATIONAL.SDR DALA2014072804238Floor Panel · delaminatedDELAMINATED FLOOR PANEL. NEW FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR DALA2014072804252Lamp · inoperativeDURING CHECK, MAINTENANCE FOUND SEVERAL LIGHTS INOPERATIVE ON THE VENTRAL EGRESS RAMP. MAINTENANCE REPLACED THE LAMPS THE AREA AND THE LIGHTS RETURNED TO AN OPERATIONAL STATE.SDR DALA2014072704234Cusp Web · crackedCRACKED CUSP WEB BETWEEN BS 256-275, X=54-60. CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 131 A -6.SDR DALA2014072604229Cusp Web · corrodedCORROSION ON RT CUSP WEB X=-48 TO X=-60, BS 826 - 845. CUSP WEB WAS REPAIRED IAW SRM 53-05 FIG 131A-2, 51-60-0, 51-10-3 PARA 14, 21, PSG00-5-1-04.SDR DALA2016110908558Retainer · crackedCORROSION AND A CRACK ON LOWER SECTION OF PRESSURE SEAL RETAINER OF RT FWD OVER WING EMERGENCY EXIT DOOR. THE SEAL RETAINER WAS REMOVED DRILLED AND INSTALLED IAW SRM 57-30-2 AND 57-10-4.SDR DALA2014080904489Angle · crackedCRACK ON ANGLE BETWEEN BS 101 - 110 X=44. ANGLE REMOVED AND REPLACED IAW SRM 51-30-2, 51-30-5, DWG 9957820-85, REV GR.SDR DALA2014072504211Cusp Web · corrodedCORROSION ON LT CUSP WEB REPAIR DOUBLER X=54 TO X=60 BETWEEN BS 930 - 936. NEW REPAIR INSTALLED IAW SRM 53-05 FIG 131A-1.SDR DALA2014072404207Frame · crackedCANTED FRAME BS 1485 HAS A 3 INCH LONG CRACK IN WEB. COMPLIED WITH ER/A 527673-14, REV O.SDR DALA2014072504214Indicator · malfunctionedAFTER GEAR EXTENSION, LT & RT BRAKE PRESSURE DROPPED TO 800PSI. HYDRAULIC QUANTITY AND PRESSURE WERE NORMAL. CREW DECLARED EMERGENCY. BRAKES OPERATED NORMALLY DURING LANDING ROLLOUT. MAINTENANCE R & R THE BRAKE PRESSURE INDICATOR.SDR DALA2014072504212Battery Pack · inoperativeDURING CHECK, MAINTENANCE FOUND MULTIPLE OVERHEAD EMERGENCY LIGHTS INOPERATIVE AT ROW 27, 28 LT AND 30B. MAINTENANCE R & R THE BATTERY PACK LOCATED AT 29DE AND THE LIGHTS RETURNED TO AN OPERATIONAL STATE.SDR DALA2014072704235Longeron · crackedCRACKED LONGERON 4 LT BS 160 AT CABIN FUSELAGE STRUCTURE. LONGERON REPLACED IAW SRM 53-02, 51-30-5 AND 51-30-2.SDR DALA2014072704232Rib · corrodedCORROSION ON SLAT TRACK SUPPORT RIB ON XOS=286, XOS=240, XOS=198 OF SLAT TRACK 2 RT. CORROSION ON SLAT TRACK SUPPORT RIB HOLES ON STA XOS= 286, XOS=240, XOS=198 OF SLAT TRACK 2 RT WERE REMOVED. BUSHINGS WERE FABRICATED AND INSTALLED IAW SRM 57-02, PAR. 9.SDR WX0A2014072972043Light · inoperativeFOUND ON WAKE UP. FLIGHT DECK EMER LIGHTS INOPERATIVE. RELAMPED FLIGHT DECK EMER LIGHTS. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A072042Light · inoperativeFOUND ON WAKE UP. TAIL CONE EMER LIGHTS INOPERATIVE & TWO AFT DROP PANEL LIGHTS BETWEEN THE LAVATORIES. RELAMPED CTR TAIL CONE LIGHT. REPLACED BATTERIES FOR THE LOWER TAIL CONE LIGHT & THE TWO DROP PANEL LIGHTS. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
Back to Mcdonnell Douglas MD-88