Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018072304601Battery · dischargedEMERERGENCY CELLING LIGHTS ARE INOPERATIVE ROW 31 TO THE TAIL. B5-107 BATTERIES DEAD. THE BATTERIES WERE REPLACED PER AMM 33-53. OPERATIONAL CHECK WAS GOOD.SDR DALA2018071904560Battery · dischargedTHE AFT CABIN EMERGENCY LIGHTS ON THE CEILING ARE INOPERATIVE. MAINTENANCE FOUND THE BATTERY AT ROW 33E,D TO BE BAD. THE BATTERY WAS REPLACED PER AMM 33-53. ALL CEILING EMERGENCY LIGHTS NOW WORK PROPERLY.SDR DALA2018071904559Battery · dischargedTHE COCKPIT & FWD GALLEY CEILING EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE EMERGENCY BATTERY PACK B5-23 PER AMM 33-53. OPERATIONAL CHECK WAS GOOD AND THE AIRCRAFT RETURNED TO SERVICE.SDR DALA2018072404641Skin · corrodedREPAIR OF CORROSION LOCATED AT THE AFT LAV SERVICE PANEL CUTOUT. FS 1307 TO FS 1322, L-21L AND L-22L.SDR DALA2018071604491Turbine · damagedTHE CREW RETURNED THE AIRCRAFT TO ATL AFTER EXPERIENCING A COMPRESSOR STALL IN THE NR 1 ENGINE DURING CLIMB. THE ENGINE WAS KEPT RUNNING AT IDLE AND THE QRH WAS COMPLIED WITH. STATION CFR SAW FLAMES (IN THE ENGINE ONLY) SO THE FLIGHT CREW PULLED THE FIRE HANDLSDR DALA2018071604489Cover · missingTHE RIGHT AFT OVERWING EXIT LIGHT COVER IS MISSING. CONTRACT MAINTENANCE INSTALLED A NEW LIGHT COVER. OPERATIONAL CHECK WAS GOOD REF AMM 33-53. AIRCRAFT OK FOR SERVICE.SDR DALA2018071204452Battery · dischargedAFT UPPER OVERWING LT AND RT EMERGENCY LIGHT INOP. R&R BATTERY FOR AFT LT AND RT EMERGENCY LIGHT PER AMM 33-53. OPS CHECK GOOD.SDR DALA2018071204451Wire · brokenEMERGENCY LIGHT ON SEAT 34D INOP. REPAIRED BROKEN WIRING IAW AMM 20-50. OPS CHECK GOOD.SDR DALA2018071204450Battery Pack · dischargedFOUND EMERGENCY EXIT LIGHT SIGN INOP DURING LIGHT CKS AT ROW 24 BOTH SIDES. R&R BATTERY PACK AT ROW 24 IAW MM 33-53. EXIT SIGNS LIGHT CKS NORM. OK FOR SVC.SDR DALA2018071104448Vane · gougedLT WING LE OF FLAP VANE GOUGED AFT OF CENTER HINGE POINT OB FLAP- REF NRC 189. FLAP VANE REPLACED ON NRC 189.SDR DALA2018071004436Light · inoperativeENTRY LIGHT FWD INOP. F/A REPORT ENTRY L1 DOOR LT BULB INOP. RE-LAMPED ENTRY WAY BULB AT L1 DOOR. OPS GOOD OK FOR SVC.SDR DALA2018070904426Smoke Detector · inoperativeAFT LT LAV SMOKE DET INOP. REPLACED AFT LEFT SMOKE DETECTOR, OPS CHECK GOOD PER AMM 26-10 MEL REMOVED.SDR DALA2018070904425Pin · pulledL1 DOOR SLIDE PINS PULLED. REPLACED L1 DOOR SLIDE PER JIC 2561-4964 A/C OK FOR SERVICE.SDR DALA2018070704418Battery · dischargedCEILING EMER LIGHTS INOP. R&R BATTERIES IN B5-106. OPS CK SAT.SDR DALA2018070704417Skin · crackedMAIN ENTRY DOOR UPPER AFT CORNER INTERNAL SURFACE IS CRACKED. REMOVED AND REPLACED MAIN ENTRY DOOR IAW AMM 52-11-00.SDR DALA2018070604389Power Supply · inoperativeON SVC CK, FOUND SEATS 31-36 EMERGENCY LIGHT AND AFT STAIRS EMERGENCY LIGHTS INOP. T/S PER AMM 33-50-00-001. FOUND EMERGENCY LIGHT BATTERY PACK B5-212 POWER SUPPLY INOP. REPLACED POWER SUPPLY ASSY IAW AMM 33-53. OPS CK NML. OK FOR SVC.SDR DALA2018070604391Fitting · crackedFOUND CRACKS ON TOP OF MOUNTING POINT OF RT GROUND SPOILER. REMOVED RT GROUND SPOILER. REMOVED CRACKED FITTING REF DWG 5936824. DRILLED NEW SPOILER FITTING REF DWG 5936824. INSTALLED NEW SPOILER FITTING REF DWG 5936824.SDR DALA2018070504362Wire · brokenSEAT ROWS 35DE AND 36 DE EMERGENCY LIGHTS OUT. FOUND BROKEN WIRE AT AMPHENOL CONNECTOR UNDER SEAT TRACK. RETERMINATED AND INSTALLED CONTACT INTO CONNECTOR PER SWPM 20-31 OPS NML.SDR DALA2018070604390Pump · cloggedALTERNATE GEAR EXTENSION, CREW REPORTS THAT WHILE ENROUTE THE RIGHT HYDRAULIC SYSTEM BECAME INOPERATIVE WITH ZERO PRESSURE INDICATION. CREW USED ALTERNATE GEAR EXTENSION TO LOWER THE LANDING GEAR. MAINTENANCE FOUND RIGHT ENGINE DRIVEN PUMP AND CASE DRAIN FILTESDR DALA2018070504365Power Supply · inoperativeAFT OVERWING EMERGENCY EXIT LIGHTS INOP. R & R POWER SUPPLY EMERGENCY EXIT OVERWING PER WDM 33-51-12. OPS CK GOOD.SDR DALA2018070504364Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACKS B5-104 ANDB5-105 BAD. R&R BATTERY PACKS B5-104 AND B5-105 PER WD 33-51-12. CKS NORMAL.SDR DALA2018070504363Engine · failedLEFT ENGINE FAILED ON T/O MAX EGT BEFORE FAILURE 625C - MAX EGT AFTER EF 800C ENGINE ROLLED BACK, POWER LOSS. REPLACED NR 1 ENGINE ON SPC 88-7110-9-0010.SDR DALA2018070504361Pin · dislodgedL1 DOOR SLIDE TOP PARACHUTE PIN DISLODGED. INSPECTED L1 DOOR SLIDE ALL LACING OK, BOTTLE PRESSURE OK, SLIDE STILL PACKED. REENGAGED TOP PARACHUTE PIN REF AMM 25-62 OK FOR SVC SLIDE PIN NEVER INSTALLED.SDR DALA2018070404358Skin · gougedRT WING ON NR 3 FLAP VANE IB SIDE UPPER SURFACE GOUGED. REMOVED DAMAGED SKIN (7" X 7") AND ACCOMPLISHED PERMANENT REPAIR ON NR 3 FLAP VANE LEADING EDGE (16.5" X 12.1" DOUBLER) IAW SRM 57-03D PAR 11 AND FIGURE 11.SDR DALA2018071804541Lens · damagedTHE EMERGENCY EXIT COVER DIFFUSER LENS DAMAGED OR MISSING. MAINTENANCE REPLACED THE EMERGENCY EXIT COVER DIFFUSER LENS. OPERATIONAL CHECK IS NORMAL AND THE AIRCRAFT WAS RETURNED TO SERVICE.SDR DALA2018070304353Door · missingON POST FLIGHT IN CAK FOUND RT ENGINE MANUAL START VALVE DOOR MISSING. INSTALLED PANEL 7808C ON NR 2 ENGINE LOWER COWL IAW DAC DWG 5938090 AND AMM 20-30.SDR DALA2018070304351Spar · crackedWHILE COMPLETING WC 5510-01106-01A FOUND CRACK IN LT STABILIZER UPPER SPAR CHORD AT UPPER INBOARD CRITICAL FASTENER LOCATION. MARKED END OF CRACK. HORIZONTAL STABILIZER REPLACED ON JOB CARD 20 OPN 5510-4135.SDR DALA2018070304350Longeron Splice · corrodedAFT CARGO COMPT LONGERON 28L SPLICE IS CORRODED AT FS 1202. CORROSION DAMAGE ON AFT CARGO LONGERON 28LT STA 1202 SPLICE FOUND OUT OF LIMITS DUE TO 100% MAT LOSS, ORIG THICKNESS .062" IAW SRM 53-01 FIG 1 AND DRAWING 3914677 REV L. REMOVED AND REPLACED SPLICE IASDR DALA2018070304349Longeron Splice · corrodedAFT CARGO COMPT LONGERON 29L SPLICE IS CORRODED AT FS STA 1202. AFT CARGO LONGERON 29LT SPLICE STA 1202 CORROSION DAMAGE FOUND OUT OF LIMITS DUE TO 100% MAT LOSS, ORIG THICKNESS .062" IAW SRM 53-01 FIG 1 AND DRAWING 3914677 REV L. REMOVED AND REPLACED SPLICE ISDR DALA2018070304348Intercostal · corrodedAFT CARGO AT STR 29L BTW STA 1212 AND 1231 INTERCOSTAL O/B SIDE HAS CORROSION. CORROSION DAMAGE ON AFT CARGO INTERCOSTAL AT LONGERON 29LT BETWEEN STA 1212 AND 1231 FOUND OUT OF LIMITS DUE TO 100% MAT LOSS, ORIG THICKNESS .050" IAW SRM 53-01 FIG 1 AND DRAWING 5SDR DALA2018070204337Battery · dischargedDOOR 2 LEFT OVER HEAD LIGHTS INOP. CHANGED BATTERIES PACK TWO 'D' CELL P/N AD4002P UNIT 107 DOOR 2 LEFT EMERGENCY OVERHEAD LIGHT OPS CHECK GOOD IAW AMM 33-50.SDR DALA2018070204335Connector · looseEMERGENCY LIGHT ON SEAT 29D INOP. SECURED LOOSE WIRING CONNECTOR AND REPLACED MISSING LENS IAW AMM 33-53-01.SDR DALA2018070104336Unknown · odorAFT LEFT LAV SMOKE DETECTOR SOUNDED ON APPROACH AND LASTED FOR ABOUT 30 SECONDS. FLIGHT ATTENDENT REPORTED AN ELECTICAL SMELL THAT LASTED ABOUT TWO MINUTES (1 MINUTE BEFORE ALARM THROUGH ABOUT 30 SECONDS AFTER). C/W NO GO ODI PREVENTION PROGRAM ATA 2172 REF LSDR DALA2018070304332Bulkhead · corrodedCORROSION FOUND AT AFT PRESSURE BULKHEAD BL0. CORROSION DAMAGE ON AFT PRESSURE BULKHEAD OEM BL0 DOUBLER FOUND OUT OF LIMITS, ORIG THICKNESS .080", MAT LOSS .040", MAT REMAINING .040" IAW DRAWING 5910130 REV ET AND SRM 53-01. REMOVED, FABRICATED NEW, AND INSTALSDR DALA2018070304328Nose Cowl · delaminatedNR 2 ENG NOSE COWL HAS DELAMINATED AT 12 O'CLOCK POSITION, CARBON FIBER PEELING AWAY. REMOVED AND REPLACED NR 2 ENG NOSE COWL PER AMM 71-10-01.SDR DALA2018070304334Engine · malfunctionedDUE TO I/B W/U OF RT ENG OIL STAINER CLOG MSG. REPLACING ENG ON SPC NUM 2 88-7110-9-0010 REF LOG 3714976. PER MCC NOTIFICATION, AN EMERGENCY WAS DECLARED.SDR DALA2018080304839Skin · corrodedREPAIR OF CORROSION AT AFT LAV SERVICE PANEL CUTOUT, STA 1322 BETWEEN L-21L AND L-22L. REPAIRED AFT LAV SERVICE PANEL CUTOUT PER ER/A 569781-14.SDR DALA2018070304327Skin · crackedFOUND SKIN CRACK AT LWR FWD CORNER OF AFT LAV PAN. REPAIRED PER ERA 569781-14 REV ORIGINAL.SDR DALA2018063004333Skin · debondedLT ELEVATOR CONTROL TAB DISBONDED ON LOWER SURFACE. REPLACED LEFT CONTROL TAB (S/N 53163) ON JOB 000-005:2730-4634-LT.SDR DALA2018070304331Doubler · corrodedAFT CARGO JACK PAD DOUBLER IS CORRODED. FOUND AREA CORRODED ON AFT CARGO JACK PAD DOUBLER WITH ORIGINAL THICKNESS .100 MATT LOSS .060 MATT REMAINING .040 TO BE OUT OF LIMITS IAW SRM 53-01 AFTER CORROSION WAS REMOVED IAW SRM 51-10-3. REMOVED AND INSTALLED NEW DSDR DALA2018070304330Structure · crackedLEADING EDGE ATTACH FASTENERS INDICATE CRACKS, RIGHT HAND SIDE, 1ST HOLE BELOW SPLIT LINE IN LE AND 2ND, 5TH, 6TH AND 7TH ABOVE. C/W ERA 525281-14AD REV A.SDR DALA2018070304329Wire · brokenSEAT MOUNTED EMERGENCY LIGHT INOP FROM ROW 31 TO 36. FOUND BAD FUSE ON BATTERY PACK, REMOVED AND REPLACED- NO HELP, AFTER INSPECTION OF WIRES FOUND BROKEN WIRE TO BATTERY PACK. REPAIRED WIRE/SPLICE IAW SPM 20-50 AND WDM 33-21. OPS CHECK GOOD.SDR DALA2018070304352Repair · departedRT HAND ELEVATOR GEAR TAB (CENTER) HAD BONDED REPAIR THAT HAS DEPARTED AIRCRAFT. REMOVED AND REPLACED RT ELEVATOR GEAR TAB IAW AMM 27-30-04. PERFORMED SATISFACTORY OPS CHECK IAW AMM-27-30-04.SDR DALA2018062904296Floor Panel · damagedAISLE FLOOR PANEL SPONGY APPROX STA 285. RMVD DAMAGE FLOOR PANEL PER AMM 53-20. INSTALLED NEW DMFG PART ON WO 10981 PER AMM 53-20. CKS GOOD. A/C OK FOR SVC.SDR DALA2018111206583Spar Cap · crackedDURING INSPECTION 5510-01074-21 OF HORIZONTAL STABILIZER A CRACK WAS FOUND ON LT REAR SPAR CAP. SPLICED IN NEW SPAR CAP PER ER/A 570530-14AD REV ORIGINAL.SDR DALA2018063004298Light · inoperativeSEAT ROW 21 EMERGENCY LIGHT INOP. RELAMPED SEAT 21 EMER BULBS PER AMM 33-53-01. CHECKS GOOD.SDR DALA2018062804249Apu · failedDURING BOARDING, THE APU HAD AN AUTO SHUTDOWN, AN ODOR BEGAN TO FILL CABIN. PASSENGERS DEPLANED. MAINTENANCE DETERMINED APU HAD AN INTERNAL FAILURE WITH SMOKE COMING OUT OF THE INLET. MAINTENANCE PERFORMED FULL DUCT BURNOUT, REPLACED THE COALESER BAGS AND THSDR DALA2018062804248Attach Fitting · corrodedHORIZONTAL STABILIZER ATTACH LUG ON THE VERTICAL STAB WAS PITTED, RT OTBD LUG, OTBD FACE. REPAIRED IAW SRM 55-02.SDR DALA2018062804247Smoke Detector · malfunctionedFIRST CLASS LAVATORY SMOKE DETECTOR ACTIVATED AT THE GATE. NO SMOKE OR ODORS NOTED. R & R THE SMOKE DETECTOR. OPS NORMAL.SDR DALA2018062804246Attach Fitting · corrodedHORIZONTAL STABILIZER ATTACH LUG ON THE VERTICAL STAB WAS PITTED, LT OTBD LUG, OTBD FACE. REPAIRED IAW SRM 55-02.
Back to Mcdonnell Douglas MD-88