Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018062804245Attach Fitting · corrodedHORIZ STABILIZER ATTACH LUG ON THE VERTICAL STAB CORRODED, RT INBD LUG OTBD FACE. REPAIRED IAW SRM 55-02.SDR DALA2018062804244Floor Panel · damagedFLOOR PANEL WAS WEAK AND CONCAVED BETWEEN SEATS 1B AND 1C. REMOVED AND REPLACED THE FLOOR PANEL IAW AMM 53-20-01/201.SDR DALA2018062804243Attach Fitting · corrodedHORIZONTAL STABILIZER ATTACH LUG ON THE VERTICAL STAB WAS PITTED, LT INBD LUG OTBD FACE. REPAIRED IAW SRM 55-02.SDR DALA2018062704238Light · inoperativeEMERGENCY LIGHT IN TAIL CONE AREA INOP. RELAMPED PER 33-50. CKS OK.SDR DALA2018062704237Battery Pack · dischargedFOUND AFT OVERWING EXIT LIGHTS INOP. R&R BATTERY PACK B5-105 PER AMM 33--53, CHK OK.SDR DALA2018062704233Light · inoperativeSEAT ROW 16 EMERGENCY LIGHT INOP. REPLACED LIGHT ASSY PER AMM 33-50.SDR DALA2018062604239Engine · making metalIN-FLIGHT SHUTDOWN AND DIVERSION TO GSP. THE FLIGHT CREW REPORTED THAT AT FL320 A SLIGHT ODOR AND VIBRATION OCCURRED; BOTH WENT AWAY THEN THE LEFT ENGINE OIL FILTER CLOG INDICATION ILLUMINATED AND THE VIBRATION RETURNED. THE ENGINE SHUT DOWN WHILE THE FLIGHT CSDR DALA2018062704236Attach Angle · brokenON ARRIVAL ATL RAMP REPORTED INSULATION STICKING OUT OF UPPER SIDE OF AFT CARGO DOOR. ON FURTHER INSPECTION FOUND DOOR FRAME TO SKIN ATTACH ANGLE BROKEN WILL NEED REPAIR. REMOVED AFT CARGO DOOR AND BEGAN INST OF NEW DOOR PER AMM 52-31. COMPLETED INSTALLATION OSDR DALA2018063004299Skin · debondedLT ELEVATOR CONTROL TAB DISBONDED ON LOWER SURFACE. REMOVED/REPLACED LEFT ELEVATOR CONTROL TAB PER WORK CARD 2730-4634-LH.SDR DALA2018062504173Battery · dischargedTAIL CAT WALK CEILING LIGHTS INOP. REMOVED AND REPLACED 'D' CELL BATTERIES TWO IN AFT LAV RIGHT. OPERATIONAL CHECK OK IAW AMM 33-50.SDR DALA2018062504201Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK B5-27 IS INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK B5-27 IAW AMM 33-53-00. OPS CHECK GOOD.SDR DALA2018062304164Lanyard · brokenFOUND 1L DOOR SLIDE GIRT BAR LANYARD BROKEN. REPLACED 1L DOOR LANYARD.SDR DALA2018063004297Fitting · crackedNR 2 NOSE COWL- 2EA ADJACENT INTERNAL CLIPS CRACKED AT 5:00 AND 7: 00 POSITIONS. NOSE COWL NEEDS REPLACED PER 7110-2001-02 STEP 2A. NOSE COWL REINSTALLED AFTER SHOP VISIT ON NRC 101- REF S/O OJ9217.SDR DALA2018062704235Wire · unsecureSEAT MOUNTED EMERG. LIGHT AT 32D IS INOP. SECURED WIRE TO EMER LIGHT AT SEAT 32D REF SPWM CH 20 OPS CKS GOOD.SDR DALA2018062304167Smoke Detector · malfunctionedLAVATORY (AFT RT) SMOKE DETECTOR WILL NOT SHUT OFF. R&R AFT RT LAV SMOKE DETECTOR AND BATT, CKS OK. REF AMM 26- 7.SDR DALA2018062204163Connector · loose18DE EMERGENCY EXIT LIGHT INOP. RELAMP NO HELP(440303) FOUND CONNECTOR LOOSE AT ROW 18DE. SECURED CONNECTOR. CHECKS GOOD.SDR DALA2018062204170Turbine · damagedDIVERTED TO TLH DUE TO LEFT ENGINE COMPRESSOR STALL. THE ENGINE WAS SHUTDOWN. MAINTENANCE FOUND TURBINE DAMAGE AND THE LEFT ENGINE WAS REPLACED.SDR DALA2018062304168Engine · smokeFUMES IN COCKPIT AND CABIN WHILE SMOKE REPORTED BY OTHER AIRCRAFT FROM ENG NR 1 ON GROUND AFTER 2.5 HOUR TAXI GATE RETURN. REMOVED AND REPLACED LT AND RT WATER SEPARATOR/COALESCER BAGS REFERENCE AMM 21-20. REPLACED NR 1 ENGINE. PERFORMED NO GO ODI PREVENTION SDR DALA2018062304166Linkage · obstructedRT THROTTLE IS JAMMED AND STUCK AT IDLE POSITION. T/S REF AMM 76-11 THROTTLE OPERATION NML AFTER CARGO COMP 3 BAGS REMOVED FROM CEILING AREA INSP LINKAGE NO DISCREPANCIES NOTED NO 30 DAY HISTORY.SDR DALA2018062304165Support Fitting · crackedRT WW TRAPEZOIDAL AND FLAP ACTUATOR SUPPORT FITTING MID-SECTION CRACKED. REMOVED AND REPLACED RT MLG W/W FLAP ACTUATOR SUPPORT FITTING IAW DRAWING 9910155 REV ED, REV DY, 5936030 REV AV, AND SRM 51-30-5. CRACK DIM 2.0".SDR DALA2018062304169Csd · damagedLT CSD OIL PRES LOW AND LT GEN OFF LIGHTS ILLUMINATED - FOLLOWED QRH - DISCONNECTED CSD. ACCORDING TO MCC NOTIFICATION, AN EMERGENCY WAS DECLARED. REMOVED CSD & GEN. FOUND CSD SHAFT TO THE GEAR BOX SHEERED. REPLACED CSD & REINSTALLED GEN IAW AMM 24-10. SYSTESDR DALA2018061904117Door · unsecureCONDITIONED AIR GROUND CONNECT DOOR, FORWARD CONDITIONED AIR DOOR FELL OFF. DEFER FWD AC DOOR PER CDL 53-30-04A. DISP GRANTED. PLAC INSTALLED. (IN FWD CLOSET).SDR DALA2018062004116Skin · dentedLT WING NR 1 FLAP VANE LWR SURFACE HAS DENTS. ACCOMPLISHED PERMANENT REPAIR ON LT WING NR 1 FLAP VANE LWR SURFACE IAW SRM 57-03 AND SRM 51-70-2 PAR 18 B.SDR DALA2018110106390Floorbeam · corrodedCORRODED CEILING ANGLE IN E&E STA 160 APPROX RBL 30. CORROSION DAMAGE ON MAIN CABIN FLOORBEAM STA 160 RBL 30 FOUND OUT OF LIMITS DUE TO 100% MAT LOSS, ORIG THICKNESS .078" IAW SRM 53-01. ACCOMPLISHED A PERMANENT REPAIR TO AREA IAW ER/A 569009-14 REV ORIGINAL.SDR DALA2018061804118Battery · dischargedEMERGENCY CEILING LIGHTS INOP ROWS 15-20. REMOVED AND REPLACED BATTERIES AT B5-102 PER AMM 33-53. LIGHTS CK NML.SDR DALA2018062004115Battery · dischargedEMERGENCY LIGHTS AT ROWS 11, 13, AND 15 INOP. REMOVED AND REPLACED BATTERIES OF BATTERY PACK B5-101 IN REF TO AMM 33-53. CHECKS GOOD.SDR DALA2018061804113Battery · dischargedEMERGENCY LIGHTS AT L1 DOOR, COCKPIT, AND R1 DOOR INOP. REMOVED AND REPLACED BATTERIES OF BATTERY PACK B5-23 IN REF TO AMM 33-53. CHECKS GOOD.SDR DALA2018061804043Spar · crackedRT HOR STAB AFT SPAR UPR CHORD- INBD FASTENER HAS A 3/16 INCH CRACK AT 12:00 EXTENDING PAST HEAD. MK'D VERIFIED WITH HFEC PER NDT SPM 06-10-01.001. RT HORIZONTAL STAB SPAR CAP SPLICE REPAIR COMPLETED ON 5510-01074-16 STEP 7, ACCESS GAINED FOR REPAIR RESTORED.SDR DALA2018061804042Light · inoperativeEMERGENCY LIGHT AT PASSENGER SEAT 19D IS INOP. R&R EMERGENCY LIGHT ASSY REF AMM 33-50. OPS CHECKS GOOD.SDR DALA2018061804041Slide · defectiveAFT SLIDE P/N D29985-103 S/N 0980 DEFECTIVE UPPER RELEASE PIN / TIE OFF. REMOVED AND REPLACE SLIDE PER 2561-4002.SDR DALA2018061804040Flap · damagedRT FLAP TRAILING EDGE DAMAGED. REMOVED AND REPLACED RT IB TRAILING EDGE FLAP PER W/C 2751-5324.SDR DALA2018062704234Closeout Panel · missingON WALKAROUND, FOUND SMALL CLOSEOUT PANEL MISSING FROM LEFT HORIZONTAL STAB NEAR FRONT SPAR INBD BOTTOM AT BARREL NUTS. ASSOCIATED ER/A 14-569512 ADDED FOR AC 9009 PER ERA 569512-14 REV ORIGINAL, SECT II, PERMANENT REPAIR, FABRICATED NEW FILLER PER DWG 5930603SDR DALA2018061604037Control Cable · severedTAKING THE RUNWAY LOST ALL STEERING TO THE RIGHT VIA THE TILLER. FOUND NOSE WHEEL STEERING CONTROL CABLE 123A SEVERED. REMOVED AND REPLACED 123A REF AMM 32-51. PERFORMED STEERING TEST REF AMM 32-52. CKS NML.SDR DALA2018061604036Battery · dischargedBOTH AFT OVERWING UPPER EXIT LIGHTS INOP. REPLACED BATTERIES AT B5105 REF AMM 33-53. OPS CHECK GOOD.SDR DALA2018061604035Doubler · crackedINITIAL INSPECTION, CRACKED PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL. PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL WAS REPAIRED PER ER/A 569279-14 REV ORIGINAL SEC I AND ETI-88-18-060 REV 4.SDR DALA2018061504023Doubler · corrodedAWR, INITIAL INSPECTION: CORROSION ON PREVIOUS REPAIR DOUBLERS AND FILLER AT AFT LAVATORY SERVICE PANEL SUMMARY OF NRC 00108, CORROSION LEVEL II, TEMPORARY REPAIR ON AFT LAVATORY SERVICE PANEL WAS ACCOMPLISHED PER ER/A 508310-14 REV A SEC III AND ETI-88-18-061SDR DALA2018061604034Battery · dischargedCATWALK EMERGENCY LIGHT INOP. REPLACED BATTERIES AT B5-28. CHECKS GOOD. REF AMM 33-53.SDR DALA2018061504022Skin · gougedLT WING OB TE FLAP HAS GOUGE IN UPPER SURFACE APPROX 43 IN FROM IB EDGE. REPAIRED PER PRI 569265-14 REV 0 AND 1. COMPLIED WITH ER/A 569265-14 REV ORIGINAL.SDR DALA2018061504021Skin · corrodedLT AFT FUSELAGE LAV SERVICE ACCESS DOOR LOWER CUTOUT IS CORRODED AT APPROX STA 1312. IN WORK REPAIR.SDR DALA2018061504020Floorbeam · corrodedDURING FORWARD GALLEY NTF REPLACEMENT, FOUND CORROSION ON FLOOR BEAM BETWEEN FLOOR PANEL 160B & 160C. REPLACED FLOOR SUPPORT REF SRM 51-01, PAGE 1 AND DWG 9936534. THIS IS CONSIDERED LEVEL 2 CORROSION.SDR DALA2018061403998Spar · crackedCRACK INDICATION RT SIDE OF VERTICAL L/E RT HAND FRONT SPAR ZFS 52.267 11TH HOLE ABOVE SPICE MKTG. LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 172-0001:5530-01045-0602/001 00206 PRI 569170-14AD REV O-1 MATCHES ERA 569170-14ADSDR DALA2018061403997Frame · damagedUPPER FRAME DAMAGED AT LATCH STRIKE AREA FOR CONDITIONED AIR SERVICE DOOR. LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0349:5300-2960/006 00017. REPAIRED PER PRI 569302-14 REV O MATCHES ERA 569302-14 REV O.SDR DALA2018061403996Doubler · corrodedAFT FRAME 1338 LOWER CHORD AFT SIDE TO APB STA 1361 HAS CORROSION IN BILGE APPROX LBL 10 - RBL 10. CORROSION DAMAGE ON AFT JACK PAD DOUBLER STA 1338 BL0 FOUND TO BE OUT OF LIMITS DUE TO 100% MAT LOSS, ORIG THICKNESS .100" IAW SRM 53-01 AND DRAWING 9915561 REV SDR DALA2018061403995Charger · inoperativeFIRST CLASS AND FWD GALLEY EMERGENCY LIGHTS INOP. R&R FWD BATTERY CHARGER PER AMM 33-50. OPS CHK GOOD.SDR DALA2018061203953Smoke Warning · false activationCAPT'S SIDE AFT LAV ALARM SOUNDING W/NO SMOKE INDICATIONS. COULD NOT DUPLICATE. A/C OK FOR SVC.SDR DALA2018061203952Battery Pack · dischargedFIRST CLASS UPPER EMERGENCY LIGHT INOP. REMOVED AND INSTALLED NEW EMERGENCY BATTERY PACK IAW AMM 33-53-00, OPS CHECK GOOD.SDR DALA2018061203950Cable · frayedTAILCONE KEVLAR CABLE FRAYED. REPLACED TAILCONE KEVLAR CABLE REF ROUTINE CARD 5350-01077-0101.SDR DALA2018061203949Skin · crackedINITIAL INSPECTION, CRACK ON FUSELAGE SKIN STA Y 69 REF LONG 21L. CRACK ON FUSELAGE SKIN STA Y 69 REF LONG 21L WAS REPAIRED PER SRM 53-04-3 FIG 8.SDR DALA2018061103936Connector · damagedSEAT 3D EMERGENCY LIGHTS INOPERATIVE. REPAIRED THE CONNECTOR IAW STANDARD WIRING PRACTICE MANUAL. CHECKED GOOD. OK FOR SERVICE.SDR DALA2018061103935Structure · dentedDURING A PREFLIGHT, FOUND SIGNIFICANT NOSE COWL DENTS AT 11:45 POSITION. REMOVED THE 1 ENGINE INLET COWL IAW PPBM 71-00 AND ERA 569353-14 AND INSTALLED SERVICEABLE INLET NOSE COWL.
Back to Mcdonnell Douglas MD-88